Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

In situ monitoring of hydrogen loss during pyrolysis of wood by neutron imaging

Hydrogen is an element of fundamental importance for energy but hard to quantify in bulk materials. Neutron radiography was used to map in situ loss of elemental hydrogen from beech tree wood samples during pyrolysis. The samples consisted of three wood cylinders (finished dowel or cut branch) of approximately 1 cm in length. The samples were pyrolyzed under vacuum in a furnace vessel that was placed inside a cold neutron imaging beamline using a temperature ramp of 5 °C/min from ambient up to 400 °C. Neutron radiographs with exposures of 30 s were sequentially recorded with a charge-coupled device over the course of the experiment. Relative absorbance/scattering of the neutron beam by each sample was based on intensity (or brightness) values as a function of pixel position. The much larger neutron cross section for hydrogen compared to carbon and oxygen enables almost direct conversion of neutron attenuation into sample hydrogen content for each time step during the pyrolysis experiment. Target and vessel temperatures were recorded concurrently with collection of the radiographs so that changes could be directly correlated to different states of pyrolysis. The most visible change appeared at the initial phase of the 400 °C plateau as evidenced by strong hydrogen loss and primarily diametric shrinking of the samples. In conclusion, the loss of elemental hydrogen between initial and final states of pyrolysis was estimated to be about 70%.

08 HYDROGEN↗

Applications of neutron-absorbing structural amorphous metal (SAM) coatings for criticality safety controls of used fuel storage, transportation, and disposal - 14534

Used nuclear fuel contains fissionable materials ({sup 235}U, {sup 239}Pu, {sup 241}Pu, etc.). To prevent nuclear criticality in used fuel storage, transportation, and disposal, neutron-absorbing materials (or neutron poisons, such as borated stainless steel, Boral{sup TM}, Metamic{sup TM}, Ni-Gd, etc.) would have to be applied. Corrosion-resistant, iron-based structural-amorphous metals (SAMs) have been tested to determine their relative corrosion resistance. Many of these materials can be applied as coatings with advanced High Velocity Oxy-Fuel (HVOF) thermal-spray technology. SAM2X5, SAM1651, and other SAMs are amorphous-metal composite alloys that have been identified as having outstanding corrosion resistance. Because of its high boron content, SAM2X5 can be applied as the neutron-absorbing coatings to the metallic support structure for criticality-safety controls of used fuel in racks in wet storage pool and baskets inside the storage containers, the transportation cask, and eventually the disposal containers in repository disposal. Research and experiment conducted at Lawrence Livermore National Laboratory indicated that the high boron-containing SAM2X5 coating could be an effective criticality control material for used fuel management. The neutron irradiation experiments and the neutron transmission measurements conducted at McClellan Nuclear Radiation Center indicated that extensive fast neutron irradiation did not change the structure of the amorphous SAM2X5 melt-spun ribbons, and SAM2X5 exhibited effective neutron absorbing capability, similar to Boral{sup TM} and Metamic{sup TM}. (authors)

36 MATERIALS SCIENCE↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

Studying Short-Range Correlations with the 12 C(e,e'pn) Reaction

We investigated electron-induced two-nucleon emission from carbon with the goal of being sensitive to and studying short-range correlations using the 12 C(e,e'pN) reaction in a triple-coincidence measurement. Two existing high-resolution spectrometers in Hall A at Jefferson Laboratory were used to detect coincident scattered electrons and struck nucleons. A large neutron detector designed and constructed specially for this experiment was used to detect the recoiling neutrons. We performed analysis of the 12 C(e,e'pn) reaction, and made direct observation of short-range correlated n-p pairs. From our analysis we conclude that there are 17.9±4.5 times more n-p short-range correlated pairs than p-p short-range correlated pairs.

43 PARTICLE ACCELERATORS↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Vortices in low-density neutron matter and cold Fermi gases

Cold gas experiments can be tuned to achieve strongly-interacting regimes such as that of low-density neutron matter found in neutron-stars' crusts. We report T=0 diffusion Monte Carlo results (i) for the ground state of both spin-1/2 fermions with short-range interactions and low-density neutron matter in a cylindrical container, and (ii) properties of these systems with a vortex line excitation. We calculate the equation of state for cold atoms and low-density neutron matter in the bulk systems, and we contrast it to our results in the cylindrical container. We compute the vortex line excitation energy for different interaction strengths, and we find agreement between cold gases and neutron matter for very low densities. We also calculate density profiles, which allow us to determine the density depletion at the vortex core, which depends strongly on the short-ranged interaction in cold atomic gases, but it is of ≈25% for neutron matter in the density regimes studied in this work. Our results can be used to constrain neutron matter properties by using measurements from cold Fermi gases experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MNSR flux performance and core lifetime analysis with HEU and LEU fuels

This paper discusses the results of flux performance and the core lifetime analyses for conversion of an MNSR core using LEU-UO{sub 2} fuel containing uranium with 12.5% enrichment. Detailed MCNP5 models were used to evaluate the flux performance. Diffusion theory REBUS-3 models were used to estimate fuel depletion rates under various operational schemes and to simulate the long-term fuel depletion history. Core lifetimes were estimated under realistic operational constraints. This study found a reduction of 7-10% in thermal neutron flux in the irradiation channels for the LEU-UO{sub 2} fuel in comparison with the HEU fuel. Therefore, for an LEU fueled core, the reactor power would have to be increased by {approx}10% from the current level of 30 kW in order to match the nominal flux level. MNSRs have a very small window of excess reactivity for operation and are designed for a very short operational cycle to avoid excessive xenon buildup. Consequently, fuel depletion calculations need to be performed using realistic operational constraints. As fuel depletes, top Be shim plates are added periodically to restore the excess reactivity for continuing operation. The maximum allowed excess reactivity at the beginning of each operating cycle is 4 mk. This study concludes that an MNSR core with LEU UO{sub 2}-12.5% fuel and a power level of 33 kW can be operated {approx}25% longer than the current HEU core operated at 30 kW. Both cores will have the same thermal neutron flux in the experiment positions. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quasiparticle random-phase approximation calculations for M 1 transitions with the noniterative finite-amplitude method and application to neutron radiative capture cross sections

Here, we derive the equations of quasiparticle random-phase approximation (QRPA) based on the finite amplitude method with the Hartree-Fock+Bardeen–Cooper–Schrieffer (HF+BCS) single-particle states, and calculate the magnetic dipole (M⁢1) transition for deformed gadolinium isotopes. Our QRPA calculation shows both large spin-flip transitions in the 5 to 10 MeV excitation energy and the low energy orbital transition that would correspond to the M⁢1 scissors mode observed in nuclear experiments. Then, we calculate neutron capture reactions based on the statistical Hauser-Feshbach theory with the photoabsorption cross sections of even-even nuclei given by QRPA. We find that the capture cross section is enhanced due to the contribution from the low energy M⁢1 transition although the calculated capture cross section still underestimates the experimental data. This issue in the calculated capture cross section could be improved by uncertainties of the low energy E⁢1 transition neglected in our QRPA calculation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

End of Year Report for ICF Related Activities on J14C

There were two main activities related to Radchem at NIF for FY ’18: Reaction-In-Flight (RIF) neutron measurements and a Bromine-doped Capsule dedicated experiment. The RIF measurements were performed by neutron activation of Thulium and Bismuth foils, held at 50 cm from Target Chamber Center (TCC), in the Neutron Activation Detectors (NADs) attached to one or more Diagnostic Instrument Man ipulators (DIMs). The Bromine-doped capsule experiment, which was to be a follow-on shot to one performed in Q4 of FY ’17, was not shot during this FY.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Applications of C 7 LYC scintillators in fast neutron spectroscopy

Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the new Ultracold Neutron beamline at the LANL UCN facility

The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey’s method of separated oscillatory fields to search for a nEDM. Here, in this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate a sufficient number of stored polarized UCN to achieve a statistical uncertainty of δd n = 2 x 10 -27 e cm in 5 calendar years of running. We also present an analytical model describing data that provides a simple parameterization of the input UCN energy spectrum on the new beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using a cylindrical-harmonics expansion

Inertial confinement fusion capsule implosions produce neutron, gamma-ray, and x-ray emission, which are recorded by a variety of detectors, both time integrated and time resolved, to determine the performance of the implosion. Further, two-dimensional emission images from multiple directions can now be combined to infer three-dimensional structures in the implosion, such as the distribution of thermonuclear fuel density, carbon ablator, and impurities. Because of the cost and complexity of the imaging systems, however, only a few measurements can be made, so reconstructions of the source must be made from a limited number of views. Here, a cylindrical-harmonics decomposition technique to reconstruct the three-dimensional object from two views in the same symmetry plane is presented. In the limit of zero order, this method recovers the Abel inversion method. The detailed algorithms used for this characterization and the resulting reconstructed neutron source from an experiment collected at the National Ignition Facility are presented.

47 OTHER INSTRUMENTATION↗

YAHFC: A Code Framework to Model Nuclear Reactions and Estimate Correlated Uncertainties

Reaction modeling is a key ingredient in designing experiments and interpreting their results, and is an essential component in the process of evaluating nuclear data and assembling nuclear data libraries used in nuclear technology applications. Typically, experimental data are available only for a handful of reaction channels and theory models are used to fill in the gaps. In addition, theory is often called upon as the arbitrator between discrepant data. Most importantly, theory and modeling are required for an accurate determination of uncertainties in the evaluated data and the correlations between the multiple channels. A fast, accurate, and flexible modeling capability has been developed at LLNL with the code system YAHFC (Yet Another Hauser-Feshbach Code). YAHFC is a Monte Carlo, Hauser-Feshbach code framework, making full use of dynamic memory allocation, derived types, and parallel computing. YAHFC can generate events to simulate experiments and is guiding experiments designed to measure inelastic neutron scattering from actinide targets. YAHFC is also being used to analyze decays from surrogate experiments, thereby enabling the inference of reaction cross sections inaccessible by direct measurement. Finally, by modeling nuclear reactions with constraints from experimental data, YAHFC can deliver complete nuclear data libraries, with evaluated uncertainties, using the modernized Generalized Nuclear Data Structure (GNDS).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Trace element geochemistry and the early lunar differentiation

The results are considered of experiments in which thermal neutron activation analysis was used to measure the halogens, U, Te, Ru, Os, and Hg in lunar samples. A calorimetric method was used for P2O5. Three Apollo 17 basalts, one Apollo 11 basalt, and one Apollo 15 basalt were used for the Ru-Os study. Os and Ru were measured in seven samples of breccia 14305 in a series of experiments to check an apparent anomaly in the isotopic composition of the Hg which it contains. A lunar model for Ru-Os partition is discussed. It is suggested that Ru and Os were partitioned and fractionated in the original differentiation of the lunar surface ocean. Fractionation among near-surface materials was less than a factor of 2 according to the lithic breccia data. Fractionations among basaltic sources were very large, exceeding 100, and primarily due to Ru. A clue to Ru and Os distributions at the depths from which mare basalts were derived may be provided by the relative ages of the basalts. These are interpreted as being related to partial melting in response to temperature increases at depth with time.

Jovanovic, S.↗

A method to measure neutron polarization using P-even asymmetry of {gamma}-quantum emission in the neutron-nuclear interaction

A new method to measure polarization of cold/thermal neutrons using P-even asymmetry in nuclear reactions induced by polarized neutrons is proposed. A scheme profiting from a large correlation of the neutron spin and the circular {gamma}-quantum polarization in the reaction (n, {gamma}) of polarized neutrons with nuclei is analyzed. This method could be used, for instance, to measure the neutron-beam polarization in experiments with frequently varying configuration. We show that high accuracy and reliability of measurements could be expected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low Activation Materials for Holders and Containments in Test Reactor Experiments

For fueled experiments or experiments with highly activated specimens there is no benefit to selecting low activation materials for holders or containments. However, some experiments, such as those with graphite or SiC specimens, or most medical isotopes, can be benefitted by selecting low activation materials for holders and containments. For many experiments the bulk of the cost and time is in the post irradiation phase. For some of these, shipping and examination costs can be dramatically reduced by careful selection of materials. This presentation will discuss low activation material candidates, the effects of impurities in these materials, and other practical issues associated with these materials. Examples of Advanced Test Reactor experiments utilizing low activation materials will also be provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved Quasi-Static Method with Step Doubling Time Adaptation

The imminent restart of the Transient Reactor Testing Facility (TREAT) at Idaho National Laboratory (INL) has brought significant attention to the development of transient reactor modeling. TREAT was designed to subject fuels and other reactor components to various degrees of neutron pulses, from minor transients to accident scenario. Inherently, this task requires predicting pulse responses due to various control rod movements; which is a complicated endeavor. Originally, this was done using an iterative process of rod movements and measuring the resulting response. With the advances in computer modeling, the current goal, preceding the restart, is to use simulation to characterize responses before experiments take place. However, neutron transient modeling is extremely computationally expensive due to the required implicit time-stepping. Therefore, methods that mitigate computation time, with minimal detriment to accuracy, are highly desired. This paper will describe the improved quasi-static method (IQS), which hopes to decrease computation time significantly from traditional 'brute force' transient methods. IQS is a spatial kinetics method that involves factorizing the flux solution into time-dependent amplitude and space- and time-dependent shape. The impetus of the method is the assumption that shape is weakly time-dependent, so expensive space-dependent evaluations are only required on large time steps. While inexpensive amplitude evaluations are performed on much smaller time steps to retain accuracy. IQS has been tested extensively on kinetics benchmarks with constant time steps. However, to test it's viability for TREAT simulations, evaluating IQS's performance with time adaptation is required. The rest of this paper will briefly describe the derivation of IQS, the time adaptation technique used, and results from a kinetic benchmarks. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Delayed Critical ORNL Unreflected HEU Metal Sphere (ORSphere)

In 1971 and 1972 experimenters at the Oak Ridge Critical Experiment Facility performed critical experiments using an unreflected metal sphere of highly enriched uranium (HEU). The sphere used for the criticality experiments, originally used for neutron leakage spectrum measurements by General Atomic Company, consisted of three main parts and were assembled with a vertical assembly machine. Two configurations were tested. The first was nearly spherical with a nominal radius of 3.467 inches and had a reactivity of 68.1 ± 2.0 cents. The sphere parts were then re-machined as a sphere with a nominal radius of 3.4425 inches. This assembly had a reactivity of -23 cents. The method, dimensions, and uncertainty of the critical experiment were extensively recorded and documented. The original purpose of the experiments was for comparison to GODIVA I experiments. The ORNL unreflected HEU Metal Spheres have been evaluated for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (scheduled for inclusion in the September 2013 edition).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗