SEARCH · Search NASA
Results for “Neutron Source”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
In situ neutron diffraction measurements of FeCrNi0.06 model alloy and DSS2507 heated to 700 and 850 °C to study sigma phase formation kinetics
This dataset contains neutron diffraction data of a ferritic single phase model alloy (FeCrNi) and a commercial grade duplex stainless steel (DSS2507) collected during in situ heating and holding at 700 and 850 °C at BL1B-NOMAD at the Spallation Neutron Source.
Data Correction of Intensity Modulated Small Angle Scattering
Abstract To investigate long length scale structures using neutron scattering, real space techniques have shown certain advantages over the conventional methods working in reciprocal space. As one of the real space measurement techniques, spin echo modulated small angle neutron scattering (SEMSANS) has attracted attention, due to its relaxed constraints on sample environment and the possibility to combine SEMSANS and a conventional small angle neutron scattering instrument. In this report, we present the first implementation of SEMSANS at a pulsed neutron source and discuss important corrections to the data due to the sample absorption. These corrections allow measurements made with different neutron wavelengths and SEMSANS configurations to be overlaid and give confidence that the measurements provide an accurate representation of the density correlations in the sample.
Implementation of a laser–neutron pump–probe capability for inelastic neutron scattering
Knowledge about nonequilibrium dynamics in spin systems is of great importance to both fundamental science and technological applications. Inelastic neutron scattering (INS) is an indispensable tool to study spin excitations in complex magnetic materials. However, conventional INS spectrometers currently only perform steady-state measurements and probe averaged properties over many collision events between spin excitations in thermodynamic equilibrium, while the exact picture of re-equilibration of these excitations remains unknown. In this paper, we report on the design and implementation of a time-resolved laser–neutron pump–probe capability at hybrid spectrometer (beamline 14-B) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. This capability allows us to excite out-of-equilibrium magnons with a nanosecond pulsed laser source and probe the resulting dynamics using INS. Here, we discussed technical aspects to implement such a capability in a neutron beamline, including choices of suitable neutron instrumentation and material systems, laser excitation scheme, experimental configurations, and relevant firmware and software development to allow for time-synchronized pump–probe measurements. We demonstrated that the laser-induced nonequilibrium structure factor is able to be resolved by INS in a quantum magnet. In conclusion, the method developed in this work will provide SNS with advanced capabilities for performing out-of-equilibrium measurements, opening up an entirely new research direction to study out-of-equilibrium phenomena using neutrons.
New precision measurements of free neutron beta decay with cold neutrons
Precision measurements in free neutron beta decay serve to determine the coupling constants of beta decay, and offer several stringent tests of the standard model. This study describes the free neutron beta decay program planned for the Fundamental Physics Beamline at the Spallation Neutron Source at Oak Ridge National Laboratory, and finally puts it into the context of other recent and planned measurements of neutron beta decay observables.
Distribution of Neutrons in a Cold Lucite Moderator
A series of experiments was performed in 2010 to study the behavior of neutrons in a cold Lucite moderator. The diffusion of neutrons in a cold moderator is described as a two-step process. In the first step, the fast neutrons produced by a neutron source collide with the nuclei of Lucite, losing energy until they reach thermal energies. In the second step, the thermal neutrons continue to diffuse without any significant loss of energy until they are absorbed or leak out of the system. However, because the Lucite moderator is at low temperature, there is less up scattering in the neutron energy compared to a Lucite moderator at room temperature. Experiments were performed to study the behavior of neutrons and their distribution in a cold Lucite moderator and their results compared to simulations. Based on these measurements, an estimation of the absorption cross section at -78.5 °C yielded a value of 0.54 barns ± 0.02 barns.
High-Resolution X-Ray and Neutron Computed Tomography of an Engine Combustion Network Spray G Gasoline Injector
Given the importance of the fuel-injection process on the combustion and emissions performance of gasoline direct injected engines, there has been significant recent interest in understanding the fluid dynamics within the injector, particularly around the needle and through the nozzles. Furthermore, the pressure losses and transients that occur in the flow passages above the needle are also of interest. Simulations of these injectors typically use the nominal design geometry, which does not always match the production geometry. Computed tomography (CT) using x-ray and neutron sources can be used to obtain the real geometry from production injectors, but there are trade-offs in using these techniques. X-ray CT provides high resolution, but cannot penetrate through the thicker parts of the injector. Neutron CT has excellent penetrating power but lower resolution. Here, we present results from a joint effort to characterize a gasoline direct injector representative of the Spray G injector as defined by the Engine Combustion Network. High-resolution (1.2 to 3 µm) x-ray CT measurements from the Advanced Photon Source at Argonne National Laboratory were combined with moderate-resolution (40 µm) neutron CT measurements from the High Flux Isotope Reactor at Oak Ridge National Laboratory to generate a complete internal geometry for the injector. This effort combined the strengths of both facilities’ capabilities, with extremely fine spatially resolved features in the nozzles and injector tips and fine resolution of internal features of the needle along the length of injector. Analysis of the resulting surface model of the internal fluid flow volumes of the injector reveals how the internal cross-sectional area and nozzle hole geometry differs slightly from the design dimensions. A simplified numerical simulation of the internal flow shows how deviations from the design geometry can alter the flow inside the sac and holes. Our results of this study will provide computational modelers with very accurate solid and surface models for use in computational fluid dynamics studies and experimentalists with increased insight into the operating characteristics of their injectors.
SU-E-J-104: Single Photon Image From PET with Insertable SPECT Collimator for Boron Neutron Capture Therapy: A Feasibility Study
Purpose: The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the BNCT. Methods: Data from the PET module, neutron source, and collimator was entered in the Monte Carlo n-particle extended (MCNPX) source code. The coincidence events were first compiled on the PET detector, and then, the events of the prompt gamma ray were collected after neutron emission by using a single photon emission computed tomography (SPECT) collimator on the PET. The obtaining of full width at half maximum (FWHM) values from the energy spectrum was performed to collect effective events for reconstructed image. In order to evaluate the images easily, five boron regions in a brain phantom were used. The image profiles were extracted from the region of interest (ROI) of a phantom. The image was reconstructed using the ordered subsets expectation maximization (OSEM) reconstruction algorithm. The image profiles and the receiver operating characteristic (ROC) curve were compiled for quantitative analysis from the two kinds of reconstructed image. Results: The prompt gamma ray energy peak of 478 keV appeared in the energy spectrum with a FWHM of 41 keV (6.4%). On the basis of the ROC curve in Region A to Region E, the differences in the area under the curve (AUC) of the PET and SPECT images were found to be 10.2%, 11.7%, 8.2% (center, Region C), 12.6%, and 10.5%, respectively. Conclusion: We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.2009 00420) and the Radiation Technology R and D program (Grant No.2013M2A2A7043498), Republic of Korea.
The JSNS 2 detector
The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.
Novel diamond cells for neutron diffraction using multi-carat CVD anvils
Traditionally, neutron diffraction at high pressure has been severely limited in pressure because low neutron flux required large sample volumes and therefore large volume presses. At the high-flux Spallation Neutron Source at the Oak Ridge National Laboratory, we have developed in this paper new, large-volume diamond anvil cells for neutron diffraction. The main features of these cells are multi-carat, single crystal chemical vapor deposition diamonds, very large diffraction apertures, and gas membranes to accommodate pressure stability, especially upon cooling. A new cell has been tested for diffraction up to 40 GPa with an unprecedented sample volume of ~0.15 mm 3 . High quality spectra were obtained in 1 h for crystalline Ni and in ~8 h for disordered glassy carbon. Finally, these new techniques will open the way for routine megabar neutron diffraction experiments.
Calculation of the performance of {sup 3}He alternative detectors with MCNPX
This paper describes the techniques that are available to calculate the performance of {sup 3}He alternative detectors using MCNPX. Calculations of the performance of safeguards detectors that use {sup 3}He have been successfully carried out for many years. In the case of coincidence or multiplicity counting, specific tallies have been implemented to calculate the Singles, Doubles and Triples counting rates. The implementation of the method was done in such a way that it equates every capture in some nuclide in the detection zone with the production of an electronic pulse from the detector. This is a very good approximation for {sup 3}He detectors and BF{sub 3} detectors. However it is not appropriate for detectors such as boron-lined proportional counters, in which the fraction of capture events leading to an electronic pulse above threshold is very dependent on the geometric arrangement, in particular the thickness and composition of the boron-containing layer. This paper gives calculations of the ideal pulse height distributions to be expected from different detector types and gives values for the probability, as a function of detector energy threshold, that a neutron capture reaction will cause an electronic pulse from the detector. This is termed the electronic efficiency. This electronic detection efficiency depends very little on the energy of the captured neutron, which in most practical cases are heavily weighted towards thermal energies. It does not depend on the position of the source neutron or moderation in the sample. For cases of interest to nuclear safeguards, measurement of uranium and plutonium in specially designed detectors, the spectrum of detected neutrons is fairly constant and thus the electronic detection efficiency becomes a detector constant. The paper discusses how the electronic detection efficiency needs to be included in the calculation of Singles, Doubles and Triples, and describes proposals to improve the tallying capability of MCNPX for such cases. (authors)
In situ neutron and synchrotron diffraction of La0.9Sr0.1Co1-yFeyO3 (y=0, 0.25, 0.75, 1)
Powder La0.9Sr0.1Co1-yFeyO3 (y=0, 0.25, 0.75, 1) samples were probed via in situ neutron (POWGEN, Spallation Neutron Source, Oak Ridge National Laboratory) and synchrotron (11-BM, Advanced Photon Source, Argonne National Lab) diffraction cycling between methane and air at temperatures ranging from room temperature to 850 C. Mail in neutron data (POWGEN) was collected on the samples at room temperature and 10 K. Additionally, gas production under similar reaction conditions as the in situ diffraction as monitored by Gasboard 3100 (California State University, Fullerton) is also included.
Benchmarking a Defeatured Geant4 NIF Model with HTOAD and HNED Neutron Data
This study benchmarks a simplified Geant4 NIF Target Chamber (TC) model against foil measurements in two instruments: the HTOAD and HNED Snout. The number of product atoms per source neutron per gram ( N 0 /n/g ) is compared across multiple locations and material configurations. The model reproduces high energy threshold reactions dominated by 14 MeV neutrons to within a few percent, depending on location. Discrepancies occur where scattering and moderation are significant for low energy threshold reactions. The defeatured Geant4 model achieves comparable statistical precision with ∼400 times less CPU time than a full fidelity TC model in MCNP. The results can be produced locally on a laptop without the need for high performance computing. Low energy biasing can be improved by preserving room return pathways and implementing IRDFF cross section evaluations.
A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction
Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.
Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly
The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.
Thermodynamic properties of a high pressure subcritical UF6/He gas volume (irradiated by an external source)
A computer simulation study concerning a compressed fissioning UF6 gas is presented. The compression is to be achieved by a ballistic piston compressor. Data on UF6 obtained with this compressor were incorporated in the simulation study. As a neutron source to create the fission events in the compressed gas, a fast burst reactor was considered. The conclusion is that it takes a neutron flux in excess of 10 to the 15th power n/sec sq cm to produce measurable increases in pressure and temperature, while a flux in excess of 10 to 19th power n/sq cm sec would probably damage the compressor.
Novel imaging technique for thermal neutrons using a fast optical camera
A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.