Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The first Fermi -LAT catalog of sources above 10 GeV

Here, we present a catalog of γ-ray sources at energies above 10 GeV based on data from the Large Area Telescope (LAT) accumulated during the first 3 yr of the Fermi Gamma-ray Space Telescope mission. The first Fermi -LAT catalog of >10 GeV sources (1FHL) has 514 sources. For each source we present location, spectrum, a measure of variability, and associations with cataloged sources at other wavelengths. We found that 449 (87%) could be associated with known sources, of which 393 (76% of the 1FHL sources) are active galactic nuclei. Of the 27 sources associated with known pulsars, we find 20 (12) to have significant pulsations in the range >10 GeV (>25 GeV). In this work we also report that, at energies above 10 GeV, unresolved sources account for 27% ± 8% of the isotropic γ-ray background, while the unresolved Galactic population contributes only at the few percent level to the Galactic diffuse background. We also highlight the subset of the 1FHL sources that are best candidates for detection at energies above 50-100 GeV with current and future ground-based γ-ray observatories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of a surrogate for plutonium electrorefining

Conducting research experiments on plutonium electrorefining is difficult due to the significant hazards and regulations associated with nuclear materials. Finding a surrogate for plutonium electrorefining studies would enable more fundamental research to be conducted. Potential surrogates were first identified by determining the physical properties required to conduct electrorefining at the same conditions commonly used in plutonium electrorefining, a molten metal and molten CaCl 2 at 1123 K. Ce-CeCl 3 , In-InCl 3 , and Pb-PbCl 2 were the only potential surrogates identified using these constraints. Sn-SnCl 2 was also tested at these same conditions. More potential surrogates were identified by changing the matrix salt and operating temperature. This expanded the potential surrogate list to also include Zn-ZnCl 2 , Sn-SnCl 2 , and Bi-BiCl 3 . Zn-ZnCl 2 was used with the LiCl-CaCl 2 (65:35 mol%) eutectic at 773 K. Sn-SnCl2 and Bi-BiCl 3 were used with the LiCl-KCl-CaCl 2 (50.5:44.2:5.3 mol%) eutectic at 673–773 K. Ce electrorefining in molten CaCl 2 resulted in a difficult to separate colloid mixture of Ce, Ca and Cl. Electrorefining rates for In in molten CaCl 2 were too slow due to InCl 3 volatilizing out of the molten salt. Only trace amounts of SnCl 2 was retained in the CaCl 2 at 1123 K resulting in impractical electrorefining rates. Zn metal product was successfully collected in the LiCl-CaCl 2 eutectic molten salt, but the metal obtained did not coalesce into one piece. Sn and Bi were successfully electrorefined in the LiCl-KCl-CaCl 2 eutectic molten salt and coalesced into product rings with high yields and coulombic efficiencies. Finally, while a surrogate could not be identified using the same conditions as plutonium electrorefining, two possible surrogates, Sn-SnCl 2 and Bi-BiCl 3 , were found that could imitate the physical configuration (i.e., molten salt on top of molten metal) of plutonium electrorefining at a reduced temperature using the eutectic LiCl-KCl-CaCl 2 salt at 673–773 K in place of CaCl 2 at 1123 K.

36 MATERIALS SCIENCE↗

Energy calibration of the NEXT-White detector with 1% resolution near Q ββ of 136 Xe

Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($\beta\beta0\nu$) require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for $\beta\beta0\nu$ searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLAS12 RICH: New Hybrid Geometry for Strangeness Studies

The Jefferson Lab (JLab) CLAS12 detector will provide a world- leading facility for the study of electron-nucleon scattering. The CLAS12 physics program is very broad and includes studies on quarks dynamics as well as studies on the meson and baryon spectroscopy with quasi-real photoproduction in a large variety of nal states. The particle identification will be complemented by a Ring Imaging Cherenkov Detector (RICH), that will provide separation of kaons from protons and pions in the momentum range between 3-8 GeV/c allowing the study of pion and kaon electroproduction in semi-inclusive deep inelastic scattering as well as studying double and triple strange baryons. In this work, we will focus on the new technologies developed for the RICH, especially on the complex optical system, that allows to reduce the photo-detection area. Particular attention is given to the characterization of the surface in relationship with the simulation capability of GEANT4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dedicated Co-deposition System for Metallic Paramagnetic Films

Here, we describe a dedicated co-sputtering/ion-mill system developed to study metallic paramagnetic films for use in magnetic microcalorimetry. Small-diameter sputtering guns allow study of several precious-metal-based paramagnetic alloy systems within a reasonable budget. We demonstrated safe operation of a 1" sputtering gun at >5x the rated maximum power, achieving deposition rates up to ~900 Å/min/gun (Cu) in our co-sputtering geometry. Demonstrated co-sputtering deposition ratios up to 100:1 allow accurate tuning of magnetic dopant concentration and eliminate the difficulty of preparing homogeneous alloy targets of extreme dilution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Magnetic Microcalorimeters for Gamma-Ray Spectroscopy

We present that integrating the SQUIDs and sensing coils of magnetic microcalorimeters onto the same die is a promising approach for maximizing flux coupling and signal/noise. However, new challenges in microfabrication must be overcome, because the underlying SQUID devices are sensitive to chemical attack and elevated processing temperatures. In this paper, we describe development and details of a microfabrication process for integrated SQUID/sensor gamma-ray magnetic microcalorimeters with electroformed gold absorbers, starting from a modified version of the STAR Cryoelectronics “Delta 1000” Josephson Junction process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Tantalum STJ X-ray Detectors at Elevated Count Rates

Here, we have developed an X-ray detector system based on Ta superconducting tunnel junctions (STJs) with an energy resolution below 10 eV under 1 keV. A principal advantage of STJs over other low-temperature detectors is their high count rate capability. In this work, we have optimized the operating conditions and digital pulse processing parameters for input count rates up to 25 kcps/pixel. Resolution below 10 eV is maintained up to 2.5 kcps/pixel, and at input rates of 25 kcps per pixel the resolution is 26 eV FWHM at 525 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a phoswich detector system for radioxenon monitoring

Abstract Measurement of radioactive xenon in the atmosphere is one of several techniques to detect nuclear weapons testing. For high sensitivity, some existing systems use beta/gamma coincidence detection to suppress background, which is very effective, but increases complexity due to separate beta and gamma detectors that require careful calibration and gain matching. In this paper, we will describe the development and evaluation of a simpler detector system, named PhosWatch, consisting of a CsI(Tl)/ BC-404 phoswich well detector, digital readout electronics, and pulse shape analysis algorithms implemented in a digital signal processor on the electronics, and compare its performance to existing multi-detector systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Ultra-Sensitive Measurements of 233U by Accelerator Mass Spectrometry for National Security Applications.

By making modifications to our previously established measurement setup, we increased our abundance sensitivity for {sup 233}U by three orders of magnitude and can now measure {sup 233}U/{sup 238}U ratios as low as 10{sup -13}. Because {sup 233}U has separate production pathways than {sup 236}U, it can provide valuable information on the particular source of anthropogenic uranium in a sample. We demonstrated the utility of our improved capability by using {sup 233}U to distinguish separate sources of anthropogenic uranium in a set of samples collected from a contaminated site. In the future, we plan to apply our new capability to characterizing {sup 233}U in a wide range of uranium materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry

Cryogenic decay energy spectrometry provides high energy resolution and enables absolute decay counting, offering an alternative measurement technique for radiochronometry. A cryogenic decay energy spectrometry experiment was conducted using a magnetic microcalorimeter to determine the age of a plutonium sample. The energy resolution was measured at 0.05% from 5 to 6 MeV. The time since sample purification was determined using the measured concentration ratio of the 241 Am/ 241 Pu radiochronometer. Sample age estimates based on 241 Pu alpha-decay and beta-decay counts, along with 241 Am decay counts, align with the expected sample age within expanded uncertainty (k = 2), supporting the accuracy of cryogenic decay energy spectrometry as a radiochronometric method.

and nuclear chemistry↗

Leveraging latest computer science tools to advance nuclear cardiology

Nuclear cardiology has unique advantages compared to other modalities, since the image analysis is already much more automated compared to what is currently clinically performed for CT, MR, or echocardiography imaging. The diverse image and clinical data available to assess coronary disease function, perfusion, flow, and associated CT data provide new opportunities, but logistically these additional assessments increase the overall complexity of SPECT/PET reporting, necessitating additional expertise and time. The advances in artificial intelligence software can be leveraged to obtain comprehensive risk predictions and diagnoses from all available data. They will allow nuclear cardiology to retain competitive edge compared to other modalities and improve its overall clinical utility. These tools will enhance diagnosis and risk prediction beyond what is possible by subjective visual analysis and mental integration of data by physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cryogenic Vibrational Spectroscopy Provides Unique Fingerprints for Glycan Identification

The structural characterization of glycans by mass spectrometry is particularly challenging. This is because of the high degree of isomerism in which glycans of the same mass can differ in their stereochemistry, attachment points, and degree of branching. Here we show that the addition of cryogenic vibrational spectroscopy to mass and mobility measurements allows one to uniquely identify and characterize these complex biopolymers. We investigate six disaccharide isomers that differ in their stereochemistry, attachment point of the glycosidic bond, and monosaccharide content, and demonstrate that we can identify each one unambiguously. Even disaccharides that differ by a single stereogenic center or in the monosaccharide sequence order show distinct vibrational fingerprints that would clearly allow their identification in a mixture, which is not possible by ion mobility spectrometry/mass spectrometry alone. Moreover, this technique can be applied to larger glycans, which we demonstrate by distinguishing isomeric branched and linear pentasaccharides. The creation of a database containing mass, collision cross section, and vibrational fingerprint measurements for glycan standards should allow unambiguous identification and characterization of these biopolymers in mixtures, providing an enabling technology for all fields of glycoscience. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma/neutron time-correlation for special nuclear material detection – Active stimulation of highly enriched uranium

A series of simulations and experiments were undertaken to explore and evaluate the potential for a novel new technique for fissile material detection and characterization, the timecorrelated pulse-height (TCPH) method, to be used concurrent with active stimulation of potential nuclear materials. In previous work TCPH has been established as a highly sensitive method for the detection and characterization of configurations of fissile material containing Plutonium in passive measurements. By actively stimulating fission with the introduction of an external radiation source, we have shown that TCPH is also an effective method of detecting and characterizing configurations of fissile material containing Highly Enriched Uranium (HEU). The TCPH method is shown to be robust in the presence of the proper choice of external radiation source. An evaluation of potential interrogation sources is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black Hills State University Underground Campus

The Black Hills State University Underground Campus (BHUC) houses a low background counting facility on the 4850' level of the Sanford Underground Research Facility. As of the date of this paper, there are currently four ultra-low background, high-purity germanium detectors installed in the BHUC and it is anticipated four more detectors will be installed within a year. In total, the BHUC will be able to accommodate up to twelve detectors with space inside a class 1000 cleanroom, an automated liquid nitrogen fill system, on-site personnel assistance and other required utilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and synthesis of astatinated benzothiazole compounds for their potential use in Targeted Alpha Therapy (TAT) strategies to treat Alzheimer's disease-associated amyloid plaques

Alzheimer's disease (AD) is a terminal neurodegenerative disease characterized by the buildup of amyloid fibrils, amorphous aggregates and tauopathies. Several treatment modalities, which rely on various biological processes to reduce disease burden, have been largely ineffective at treating Alzheimer's disease. Targeted alpha therapy (TAT) has demonstrated positive results in the treatment of cancer. Benzothiazole derivatives have been successfully shown to target these plaques and are used in several imaging applications. One such derivative, Flutemetamol (Vizamyl TM ) is an FDA approved diagnostic tool for PET imaging of AD-associated plaques. We report the radiolabeling of benzothiazole derivatives with 211 At, a 7.2 h alpha emitting radionuclide, using a copper catalyzed reaction with a boronic acid precursor molecule. In conclusion, our final compound [ 211 At]3'-At-PIB-OMe had a radiochemical yield of 55% and was found to be stable for at least 3 h in phosphate buffered saline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗