Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Preliminary Photon Pressure Measurements Using a Solar Simulator

Initial proof of concept photon momentum measurements reported verifying photon pressure on a simulated sail material can be measured under high vacuum conditions using a full spectrum solar simulator and a vacuum compatible force measurement system. Second order effects such as sample reflectivity, beam uniformity, radiometric flux measurement accuracy, and the optical system have been accounted for in evaluating these measurements.

Gray, Perry A.↗

Visible spectroscopy diagnostics for tungsten source assessment in the WEST tokamak: First measurements

The present work concerns the measurements obtained with the Tungsten (W) Environment in Steady-state Tokamak (WEST) visible spectroscopy system during the first experimental campaign. This system has been developed in the framework of the WEST project that equipped the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFC) in view of preparing for ITER operation. The goal of this diagnostic is to measure the PFC sources and the deuterium recycling with spectral, spatial, and temporal resolution adapted to the predicted power deposition profiles on the objects observed. Three kinds of PFCs are monitored: the Ion Cyclotron Resonance Heating (ICRH) antenna and Low Hybrid Current Drive (LHCD) launcher W limiters; one of the 6 W inner bumpers; and the upper and lower W divertors. Large-aperture in-vessel actively cooled optical systems (f-number ~ 3) were installed for each view and connected to optical fibres. A total of 240 optical fibers can be distributed on various detection systems including a fast response-time, multi-channel, filtered photodetector-based “Filterscope” system, developed by Oak Ridge National Laboratory (USA) as well as grating spectrometers optimized for multi-sightline analysis. The first WEST experimental campaign conducted in 2017 has been dedicated to plasma start-up development during which the visible spectroscopy system has provided crucial information related to the impurity content first and then impurity sources. The diagnostic setup for that first experimental campaign was limited to the inner bumper and outer limiters but was sufficient to demonstrate that the optical setup was in accordance with the specifications. The radiance calibration procedure allowed us to estimate fluxes from the main limiter of about 8 × 10 18 atoms/(s m 2 ) and to show a first W source radial profile along the outboard limiter.

Meyer, O.↗

Optical correlators for automated rendezvous and capture

Two dimensional image correlation is a robust technique for recognizing known objects and determining their position with respect to the sensing platform. This capability is of paramount importance to vehicles which must rendezvous and capture using only on-board sensors and processors. Standard digital processors can provide the necessary correlations, but their speed, weight, size and power consumption make them undesirable components of an on-board tracking system. Optical correlators provide correlation results comparable to digital systems, but with a fraction of the size, weight and power and often many times faster. This presentation discusses the application of optical correlators to Automated Rendezvous & Capture (AR&C), and the specific work being done at the Johnson Space Center and DARPA in developing optical correlator technology.

Juday, Richard↗

Vacuum-Compatible Wideband White Light and Laser Combiner Source System

For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.

Azizi, Alineza↗

PRE-DISCOVERY 2007 IMAGE OF THE HR 8799 PLANETARY SYSTEM

We present a pre-discovery H-band image of the HR 8799 planetary system that reveals all three planets in 2007 August. The data were obtained with the Keck adaptive optics system, using angular differential imaging and a coronagraph. We confirm the physical association of all three planets, including HR 8799d, which had only been detected in 2008 images taken two months apart, and whose association with HR 8799 was least secure until now. We confirm that the planets are 2-3 mag fainter than field brown dwarfs of comparable near-infrared colors. We note that similar underluminosity is characteristic of young substellar objects at the L/T spectral type transition, and is likely due to enhanced dust content and non-equilibrium CO/CH{sub 4} chemistry in their atmospheres. Finally, we place an upper limit of approx>18 mag arcsec{sup -2} on the >120 AU H-band dust-scattered light from the HR 8799 debris disk. The corresponding integrated scattered light flux is <10{sup -4} times the photospheric level, 24 times fainter than for the debris ring around HR 4796A.

79 ASTRONOMY AND ASTROPHYSICS↗

Light field X-ray optics

Devices, systems and methods for performing X-ray scans with a single line of sight using a lens array for capturing the light field of the X-rays are described. In one example aspect, an X-ray optical system includes a primary optics subsection positioned to receive incoming X-rays after traversal through an object and to redirect the received incoming X-rays onto an intermediate image plane. The system also includes a microlens array positioned at or close to the intermediate image plane to receive at least some of the received incoming X-rays after redirection by the primary optics subsection to diffract the X-rays that are incident thereupon.

Kozioziemski, Bernard J.↗

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-D-213-03: Towards An Optimized 3D Scintillation Dosimetry Tool for Quality Assurance of Dynamic Radiotherapy Techniques

Purpose: The purpose of this work is to simulate a multi-focus plenoptic camera used as the measuring device in a real-time three-dimensional scintillation dosimeter. Simulating and optimizing this realistic optical system will bridge the technological gap between concept validation and a clinically viable tool that can provide highly efficient, accurate and precise measurements for dynamic radiotherapy techniques. Methods: The experimental prototype, previously developed for proof of concept purposes, uses an off-the-shelf multi-focus plenoptic camera. With an array of interleaved microlenses of different focal lengths, this camera records spatial and angular information of light emitted by a plastic scintillator volume. The three distinct microlens focal lengths were determined experimentally for use as baseline parameters by measuring image-to-object magnification for different distances in object space. A simulated plenoptic system was implemented using the non-sequential ray tracing software Zemax: this tool allows complete simulation of multiple optical paths by modeling interactions at interfaces such as scatter, diffraction, reflection and refraction. The active sensor was modeled based on the camera manufacturer specifications by a 2048×2048, 5 µm-pixel pitch sensor. Planar light sources, simulating the plastic scintillator volume, were employed for ray tracing simulations. Results: The microlens focal lengths were determined to be 384, 327 and 290 µm. A realistic multi-focus plenoptic system, with independently defined and optimizable specifications, was fully simulated. A f/2.9 and 54 mm-focal length Double Gauss objective was modeled as the system’s main lens. A three-focal length hexagonal microlens array of 250-µm thickness was designed, acting as an image-relay system between the main lens and sensor. Conclusion: Simulation of a fully modeled multi-focus plenoptic camera enables the decoupled optimization of the main lens and microlens specifications. This work leads the way to improving the 3D dosimeter’s achievable resolution, efficiency and build for providing a quality assurance tool fully meeting clinical needs. M.R. is financially supported by a Master’s Canada Graduate Scholarship from the NSERC. This research is also supported by the NSERC Industrial Research Chair in Optical Design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Control of Space Structures (ACOSS) model 2

A complete description of the active control of space structures model #2 which is a simple but realistic evaluation model is given. The design of this system was driven by the desire to incorporate certain attributes into the overall system characteristics. The desired features were structural design based on realistic sizes and weights; a simple unclassified optical system with associated performance measures and tolerance; and a set of disturbances typical of equipment vibration and attitude control (slew). The resulting model is described in detail along with the resulting mode shapes and natural frequencies of the system. A description of the line-of-sight performance measure including theory and implementation is given.

Henderson, T. C.↗

Recent flight-test results of optical airdata techniques

Optical techniques for measuring airdata parameters were demonstrated with promising results on high performance fighter aircraft. These systems can measure the airspeed vector, and some are not as dependent on special in-flight calibration processes as current systems. Optical concepts for measuring freestream static temperature and density are feasible for in-flight applications. The best feature of these concepts is that the air data measurements are obtained nonintrusively, and for the most part well into the freestream region of the flow field about the aircraft. Current requirements for measuring air data at high angle of attack, and future need to measure the same information at hypersonic flight conditions place strains on existing techniques. Optical technology advances show outstanding potential for application in future programs and promise to make common use of optical concepts a reality. Results from several flight-test programs are summarized, and the technology advances required to make optical airdata techniques practical are identified.

Bogue, Rodney K.↗

Digital optical recorder-reproducer system

A mass archival optical recording and reproduction system includes a recording light source such as a laser beam focussed and directed upon an acousto-optic linear modulator array (or page composer) that receives parallel blocks of data converted from a serial stream of digital data to be stored. The page composer imparts to the laser beam modulation representative of a plurality of parallel channels of data and through focussing optics downstream of the page composer parallel arrays of optical spots are recorded upon a suitable recording medium such as a photographic film floppy disc. The recording medium may be substantially frictionlessly and stably positioned for recording at a record/read station by an air-bearing platen arrangement which is preferably thermodynamically non-throttling so that the recording film may be positioned in the path of the information-carrying light beam in a static or dynamic mode. During readout, the page composer is bypassed and a readout light beam is focussed directly upon the recording medium containing an array of previously recorded digital spots, a sync bit, data positioning bits, and a tracking band. The readout beam which has been directed through the recording medium is then imaged upon a photodetector array, the output of which may be coupled to suitable electronic processing circuitry, such as a digital multiplexer, whereby the parallel spot array is converted back into the original serial data stream.

Reddersen, Brad R.↗

Degradation of MODIS Optics and its Reflective Solar Bands Calibration

The MODerate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with wavelength ranging from 0.41 micron to 14.5 micron and spatial resolution between 0.25, 0.5, and 1.0 km at Nadir. Its ProtoFlight Model (PFM) on the NASA EOS Terra spacecraft has been providing global coverage of the Land, Ocean, and Atmosphere for the science community since the instrument opened its Nadir door on 24 February 2000. The MODIS optical system consists of a 2-sided paddle wheel scan mirror, a fold mirror, a primary mirror, and other aft optics. The sensor's 20 reflective solar bands from 0.41 to 2.1 micron are calibrated on-orbit by a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). In addition to SD, degradation of the MODIS optics in the reflective solar bands has been observed, including variations in degradation between the two sides of the MODIS scan mirror. During MODIS first year of on-orbit operation, the overall degradations at the shortest wavelength (0.41 micron) are about 3% for SD, and in excess of 10% for the MODIS system. In this paper, we will present our degradation analysis results and discuss their impact on the reflective solar bands' on-orbit calibration.

Xiong, X.↗

Pixelized Device Control Actuators for Large Adaptive Optics

A fully integrated, compact, adaptive space optic mirror assembly has been developed, incorporating new advances in ultralight, high-performance composite mirrors. The composite mirrors use Q-switch matrix architecture-based pixelized control (PMN-PT) actuators, which achieve high-performance, large adaptive optic capability, while reducing the weight of present adaptive optic systems. The self-contained, fully assembled, 11x11x4-in. (approx.= 28x28x10-cm) unit integrates a very-high-performance 8-in. (approx.=20-cm) optic, and has 8-kHz true bandwidth. The assembled unit weighs less than 15 pounds (=6.8 kg), including all mechanical assemblies, power electronics, control electronics, drive electronics, face sheet, wiring, and cabling. It requires just three wires to be attached (power, ground, and signal) for full-function systems integration, and uses a steel-frame and epoxied electronics. The three main innovations are: 1. Ultralightweight composite optics: A new replication method for fabrication of very thin composite 20-cm-diameter laminate face sheets with good as-fabricated optical figure was developed. The approach is a new mandrel resin surface deposition onto previously fabricated thin composite laminates. 2. Matrix (regenerative) power topology: Waveform correction can be achieved across an entire face sheet at 6 kHz, even for large actuator counts. In practice, it was found to be better to develop a quadrant drive, that is, four quadrants of 169 actuators behind the face sheet. Each quadrant has a single, small, regenerative power supply driving all 169 actuators at 8 kHz in effective parallel. 3. Q-switch drive architecture: The Q-switch innovation is at the heart of the matrix architecture, and allows for a very fast current draw into a desired actuator element in 120 counts of a MHz clock without any actuator coupling.

Knowles, Gareth J.↗

Optical infrared sky survey instrumentation

An unusual, highly modified, Baker reflector-corrector class telescope has been adapted for wide field survey photography in the near infrared. This optical system uses a full field corrector plate and a field flattening lens to provide a flat field subtending about 4.5 deg on the sky. The small aperture telescope (20 inch primary) has been modified for use in the Newtonian focus configuration while preserving the optical elements of the Prime focus configuration. The telescope has been further modified to accept a very large format (146mm diameter photocathode) image intensifier camera to serve as a detector. The camera output is recorded photographically on film rather than glass plates. This unique instrument system is used in a program of sky survey photography in the optical infrared (8000-9000A bandpass) supplemented by visual bandpass photography. The photographs obtained with this system are of value not only for the extreme redness of the band but also because of their high resolution and their freedom from hydrogen emission.

Craine, E. R.↗

Intelligent systems technology infrastructure for integrated systems

A system infrastructure must be properly designed and integrated from the conceptual development phase to accommodate evolutionary intelligent technologies. Several technology development activities were identified that may have application to rendezvous and capture systems. Optical correlators in conjunction with fuzzy logic control might be used for the identification, tracking, and capture of either cooperative or non-cooperative targets without the intensive computational requirements associated with vision processing. A hybrid digital/analog system was developed and tested with a robotic arm. An aircraft refueling application demonstration is planned within two years. Initially this demonstration will be ground based with a follow-on air based demonstration. System dependability measurement and modeling techniques are being developed for fault management applications. This involves usage of incremental solution/evaluation techniques and modularized systems to facilitate reuse and to take advantage of natural partitions in system models. Though not yet commercially available and currently subject to accuracy limitations, technology is being developed to perform optical matrix operations to enhance computational speed. Optical terrain recognition using camera image sequencing processed with optical correlators is being developed to determine position and velocity in support of lander guidance. The system is planned for testing in conjunction with Dryden Flight Research Facility. Advanced architecture technology is defining open architecture design constraints, test bed concepts (processors, multiple hardware/software and multi-dimensional user support, knowledge/tool sharing infrastructure), and software engineering interface issues.

Lum, Henry↗

Optical neural engine for solving scientific partial differential equations

Abstract Solving partial differential equations (PDEs) is the cornerstone of scientific research and development. Data-driven machine learning (ML) approaches are emerging to accelerate time-consuming and computation-intensive numerical simulations of PDEs. Although optical systems offer high-throughput and energy-efficient ML hardware, their demonstration for solving PDEs is limited. Here, we present an optical neural engine (ONE) architecture combining diffractive optical neural networks for Fourier space processing and optical crossbar structures for real space processing to solve time-dependent and time-independent PDEs in diverse disciplines, including Darcy flow equation, the magnetostatic Poisson’s equation in demagnetization, the Navier-Stokes equation in incompressible fluid, Maxwell’s equations in nanophotonic metasurfaces, and coupled PDEs in a multiphysics system. We numerically and experimentally demonstrate the capability of the ONE architecture, which not only leverages the advantages of high-performance dual-space processing for outperforming traditional PDE solvers and being comparable with state-of-the-art ML models but also can be implemented using optical computing hardware with unique features of low-energy and highly parallel constant-time processing irrespective of model scales and real-time reconfigurability for tackling multiple tasks with the same architecture. The demonstrated architecture offers a versatile and powerful platform for large-scale scientific and engineering computations.

Tang, Yingheng (ORCID:0009000153622546)↗

On a two-pass scheme without a faraday mirror for free-space relativistic quantum cryptography

The stability of destructive interference independent of the input polarization and the state of a quantum communication channel in fiber optic systems used in quantum cryptography plays a principal role in providing the security of communicated keys. A novel optical scheme is proposed that can be used both in relativistic quantum cryptography for communicating keys in open space and for communicating them over fiber optic lines. The scheme ensures stability of destructive interference and admits simple automatic balancing of a fiber interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗