Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Photon Reconstruction and Identification with the ATLAS detector

The understanding of the photons reconstruction will be one of the key issues at the start-up of data-taking with the ATLAS experiment at the LHC. Large statistics samples of photons produced in association with jets are expected over a wide range of E{sub T}.The photon reconstruction is based on an electromagnetic-cluster-seeded algorithm which classifies as photons those clusters which have no matching prompt track. These are then subdivided into converted or non-converted photon candidates depending on the presence of one or more tracker-reconstructed electron-positron pairs pointing to it. The precise knowledge of the material upstream the calorimeter and a correct treatment of the converted photons are critical for a correct photon reconstruction and identification.The photon identification is based almost entirely on the analysis of the shower shapes in the calorimeter. The goal is to achieve an efficient photon selection in the range from 20 GeV to several hundreds GeV with a rejection of 10{sup 3}-10{sup 4} against QCD jets in the moderate transverse momentum region of 20 to 100 GeV, which is the relevant one for H->gammagamma searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R-axion detection at LHC

Supersymmetric models with spontaneously broken approximate R-symmetry contains a light spin 0 particle, the R-axion. The properties of the particle can be a powerful probe of the structure of the new physics. In this paper, we discuss the possibilities of the R-axion detection at the LHC experiments. It is challenge to observe this light particle in the LHC environment. However, for typical values in which the mass of the R-axion is a few hundred MeV, we show that those particles can be detected by searching for displaced vertices from R-axion decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Virus‐Based Pyroelectricity

Abstract The first observation of heat‐induced electrical potential generation on a virus and its detection through pyroelectricity are presented. Specifically, the authors investigate the pyroelectric properties of the M13 phage, which possesses inherent dipole structures derived from the noncentrosymmetric arrangement of the major coat protein (pVIII) with an α‐helical conformation. Unidirectional polarization of the phage is achieved through genetic engineering of the tail protein (pIII) and template‐assisted self‐assembly techniques. By modifying the pVIII proteins with varying numbers of glutamate residues, the structure‐dependent tunable pyroelectric properties of the phage are explored. The most polarized phage exhibits a pyroelectric coefficient of 0.13 µC m −2 °C −1 . Computational modeling and circular dichroism (CD) spectroscopy analysis confirm that the unfolding of α‐helices within the pVIII proteins leads to changes in phage polarization upon heating. Moreover, the phage is genetically modified to enable its pyroelectric function in diverse chemical environments. This phage‐based approach not only provides valuable insights into bio‐pyroelectricity but also opens up new opportunities for the detection of various viral particles. Furthermore, it holds great potential for the development of novel biomaterials for future applications in biosensors and bioelectric materials.

Kim, Han↗

Pressure-based process monitoring of direct-ink write material extrusion additive manufacturing

As additive manufacturing (AM) has become a reliable method for creating complex and unique hardware rapidly, the quality assurance of printed parts remains a priority. In situ process monitoring offers an approach for performing quality control while simultaneously minimizing post-production inspection. For extrusion printing processes, direct linkages between extrusion pressure fluctuations and print defects can be established by integrating pressure sensors onto the print head. In this work, the sensitivity of process monitoring is tested using engineered spherical defects. Pressure and force sensors located near an ink reservoir and just before the nozzle are shown to assist in identification of air bubbles, changes in height between the print head and build surface, clogs, and particle aggregates with a detection threshold of 60–70% of the nozzle diameter. Visual evidence of printed bead distortion is quantified using optical image analysis and correlated to pressure measurements. Importantly, this methodology provides an ability to monitor the quality of AM parts produced by extrusion printing methods and can be accomplished using commonly available pressure-sensing equipment.

36 MATERIALS SCIENCE↗

Closed hierarchies and non-equilibrium steady states of driven systems

We present a class of tractable non-equilibrium dynamical quantum systems which includes combinations of injection, detection and extraction of particles interspersed by unitary evolution. We show how such operations generate a hierarchy of equations tying lower correlation functions with higher order ones. The hierarchy closes for particular choices of measurements and leads to a rich class of evolutions whose long time behavior can be simulated efficiently. In particular, we use the method to describe the dynamics of current generation through a generalized quantum exclusion process, and exhibit an explicit formula for the long time energy distribution in the limit of weak driving.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of the GAPS experiment to low-energy cosmic-ray antiprotons

The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07–0.21 GeV/n at the top of the atmosphere. With these high statistics extending to lower energies than any previous experiment, and with complementary sources of experimental uncertainty compared to traditional magnetic spectrometers, the GAPS antiproton measurement will be sensitive to dark matter, primordial black holes, and cosmic ray propagation. The antiproton measurement will also validate the GAPS antinucleus identification technique for the antideuteron and antihelium rare-event searches. Finally, this analysis demonstrates the GAPS sensitivity to cosmic-ray antiprotons using a full instrument simulation and event reconstruction, and including solar and atmospheric effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a technology for the fabrication of Low-Gain Avalanche Diodes at BNL

Low-Gain Avalanche Detectors are gathering interest in the High-Energy Physics community thanks to their fast-timing and radiation-hardness properties. One example of this includes plans to exploit timing detectors for the upgrades of the ATLAS and CMS detectors at the High Luminosity LHC. This new technology has also raised interest for its possible application for photon detection in medical physics, imaging and photon science. The main characteristic of this type of device is a thin and highly-doped layer that provides internal and moderate gain, in the order of 10–20, that enhances the signal amplitude. Furthermore the thin substrate, of only few tens of microns, allows for fast carrier collection. This paper offers here details on the fabrication technology, specifically developed at Brookhaven National Laboratory for the detection of minimum ionizing particles. The static electrical characterization and the gain measurements on prototypes will be also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗

Current limitations and challenges in nanowaste detection, characterisation and monitoring

Highlights: • First review on detection of nanomaterials in complex waste samples. • Focus on nanoparticles in solid, liquid and gaseous waste samples. • Summary of current applicable methods for nanowaste detection and characterisation. • Limitations and challenges of characterisation of nanoparticles in waste. - Abstract: Engineered nanomaterials (ENMs) are already extensively used in diverse consumer products. Along the life cycle of a nano-enabled product, ENMs can be released and subsequently accumulate in the environment. Material flow models also indicate that a variety of ENMs may accumulate in waste streams. Therefore, a new type of waste, so-called nanowaste, is generated when end-of-life ENMs and nano-enabled products are disposed of. In terms of the precautionary principle, environmental monitoring of end-of-life ENMs is crucial to allow assessment of the potential impact of nanowaste on our ecosystem. Trace analysis and quantification of nanoparticulate species is very challenging because of the variety of ENM types that are used in products and low concentrations of nanowaste expected in complex environmental media. In the framework of this paper, challenges in nanowaste characterisation and appropriate analytical techniques which can be applied to nanowaste analysis are summarised. Recent case studies focussing on the characterisation of ENMs in waste streams are discussed. Most studies aim to investigate the fate of nanowaste during incineration, particularly considering aerosol measurements; whereas, detailed studies focusing on the potential release of nanowaste during waste recycling processes are currently not available. In terms of suitable analytical methods, separation techniques coupled to spectrometry-based methods are promising tools to detect nanowaste and determine particle size distribution in liquid waste samples. Standardised leaching protocols can be applied to generate soluble fractions stemming from solid wastes, while micro- and ultrafiltration can be used to enrich nanoparticulate species. Imaging techniques combined with X-ray-based methods are powerful tools for determining particle size, morphology and screening elemental composition. However, quantification of nanowaste is currently hampered due to the problem to differentiate engineered from naturally-occurring nanoparticles. A promising approach to face these challenges in nanowaste characterisation might be the application of nanotracers with unique optical properties, elemental or isotopic fingerprints. At present, there is also a need to develop and standardise analytical protocols regarding nanowaste sampling, separation and quantification. In general, more experimental studies are needed to examine the fate and transport of ENMs in waste streams and to deduce transfer coefficients, respectively to develop reliable material flow models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural and Chemical Evolution of Li- and Mn-rich Layered Cathode Material

Lithium (Li)- and manganese-rich (LMR) layered-structure materials are very promising cathodes for high energy density lithium-ion batteries. However, their voltage fading mechanism and its relationships with fundamental structural changes are far from being sufficiently understood. Here we report the detailed phase transformation pathway in the LMR cathode (Li[Li0.2Ni0.2Mn0.6]O2) during cycling for the samples prepared by hydro-thermal assistant method. It is found the transformation pathway of LMR cathode is closely correlated to its initial structure and preparation conditions. The results reveal that LMR cathode prepared by HA approach experiences a phase transformation from the layered structure to a LT-LiCoO2 type defect spinel-like structure (Fd-3m space group) and then to a disordered rock-salt structure (Fm-3m space group). The voltage fade can be well correlated with the Li ion insertion into octahedral sites, rather than tetrahedral sites, in both defect spinel-like structure and disordered rock-salt structure. The reversible Li insertion/removal into/from the disordered rock-salt structure is ascribed to the Li excess environment that can satisfy the Li percolating in the disordered rock-salt structure despite the increased kinetic barrier. Meanwhile, because of the presence of a great amount of oxygen vacancies, a significant decrease of Mn valence is detected in the cycled particle, which is below that anticipated for a potentially damaging Jahn-Teller distortion (+3.5). Clarification of the phase transformation pathway, cation redistribution, oxygen vacancy and Mn valence change undoubtedly provides insights into a profound understanding on the voltage fade, and capacity degradation of LMR cathode. The results also inspire us to further enhance the reversibility of LMR cathode via improving its surface structural stability.

Cation redistribution↗

Electron magnetic reconnection without ion coupling in Earth’s turbulent magnetosheath

Magnetic reconnection in current sheets is a magnetic-to-particle energy conversion process that is fundamental to many space and laboratory plasma systems. In the standard model of reconnection, this process occurs in a minuscule electron-scale diffusion region. On larger scales, ions couple to the newly reconnected magnetic-field lines and are ejected away from the diffusion region in the form of bi-directional ion jets at the ion Alfvén speed. Much of the energy conversion occurs in spatially extended ion exhausts downstream of the diffusion region. In turbulent plasmas, which contain a large number of small-scale current sheets, reconnection has long been suggested to have a major role in the dissipation of turbulent energy at kinetic scales. However, evidence for reconnection plasma jetting in small-scale turbulent plasmas has so far been lacking. Here we report observations made in Earth’s turbulent magnetosheath region (downstream of the bow shock) of an electron-scale current sheet in which diverging bi-directional super-ion-Alfvénic electron jets, parallel electric fields and enhanced magnetic-to-particle energy conversion were detected. Contrary to the standard model of reconnection, the thin reconnecting current sheet was not embedded in a wider ion-scale current layer and no ion jets were detected. Observations of this and other similar, but unidirectional, electron jet events without signatures of ion reconnection reveal a form of reconnection that can drive turbulent energy transfer and dissipation in electron-scale current sheets without ion coupling.

79 ASTRONOMY AND ASTROPHYSICS↗

The galactic plane survey performed by the Milagro detector

Milagro is a water Cherenkov detector that continuously views the entire overhead sky at TeV energies. The large field-of-view of 2 steradians combined with the long observation time makes Milagro the most sensitive instrument available for the study of large, low surface brightness sources such as the gamma radiation arising from interactions of cosmic radiation with interstellar matter and for the search of steady and transient sources. Recent development in the analysis techniques used by the Milagro collaboration significantly improved the sensitivity of the Milagro detector. Here we report on observations of gamma-ray sources in the region of Galactic longitude included between 30 and 220 degrees and Galactic latitude between -10 and 10 degrees, on the evaluation of the Galactic diffuse emission from the same region and on the observation of long time variability of Mrk 421.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The XENON Dark Matter Project: Status of the XENON100 Phase

The XENON100 experiment aims to detect cold dark matter particles via their elastic collisions with xenon nuclei. An ultra-low background, two-phase time projection chamber with a total of 170 kg of xenon (65 kg in the target region and 105 kg in the active veto) has been installed at the Gran Sasso Underground Laboratory and is currently in commissioning phase. We review the design and performance of the detector and its associated systems, present status, preliminary calibration results, background prediction and projected sensitivity. With a 6000 kg-day background-free exposure, XENON100 will reach a sensitivity of spin-independent WIMP-nucleon cross section of 2x10{sup -45} cm{sup 2} by the end of 2009. We also discuss our plan to upgrade the XENON100 experiment to improve the sensitivity by another order of magnitude by 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Once More on the Position Resolution of DROIDs

The absorber of a distributed readout imaging detector (DROID) represents a narrow strip of a superconducting material in which an interaction of a primary particle has occurred. As a result of the primary particle energy absorption, nonequilibrium quasiparticles are generated. Quasiparticles diffuse from the interaction point to the left and the right ends of the absorber where superconducting tunnel junctions (STJs) are located. As a result of the primary particle registration by the DROID, there are two signals at the output of STJs' amplifiers. In this work, the formulae for the mean square deviations of the primary particle energy and interaction coordinate with absorber are derived. These formulae account for the quasiparticle loss during diffusion to the STJs, the imperfect quasiparticle trapping in STJs, and the correlation between fluctuations of the STJs' signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Cryogenic Dark Matter Search (CDMS) experiment: Results, status and perspective

The Cryogenic Dark Matter Search experiment (CDMS) is using Phonon+Ionization detectors to search for Dark Matter in the form of Weakly Interactive Massive Particles (WIMPs). We report on new results from the operation of CDMS five 'towers' at Soudan underground laboratory. With new and more massive detectors, SuperCDMS project has been started since March 2009. We report on the current status of SuperCDMS and its perspective.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bulk and Surface Charge Collection: CDMS Detector Performance and Design Implications

The Cryogenic Dark Matter Search (CDMS) searches for Weakly Interacting Massive Particles (WIMPs) with cryogenic germanium particle detectors. These detectors discriminate between nuclear-recoil candidate and electron-recoil background events by collecting both phonon and ionization energy from interactions in the crystal. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron-recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk charge trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices shows that hydrogen passivation of the amorphous silicon blocking layer does not reduce the effects of surface trapping. Other data shows that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors increases surface trapping, causing a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and at the experimental site in Soudan, MN have provided methods to optimize the neutralization process and monitor running conditions to maintain maximal ionization collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity and systematics of calorimetric neutrino mass experiments

A large calorimetric neutrino mass experiment using thermal detectors is expected to play a crucial role in the challenge for directly assessing the neutrino mass. We discuss and compare here two approaches for the estimation of the experimental sensitivity of such an experiment. The first method uses an analytic formulation and allows to obtain readily a close estimate over a wide range of experimental configurations. The second method is based on a Montecarlo technique and is more precise and reliable. The Montecarlo approach is then exploited to study some sources of systematic uncertainties peculiar to calorimetric experiments. Finally, the tools are applied to investigate the optimal experimental configuration of the MARE project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DMTPC: A dark matter detector with directional sensitivity

By correlating nuclear recoil directions with the Earth's direction of motion through the Galaxy, a directional dark matter detector can unambiguously detect Weakly Interacting Massive Particles (WIMPs), even in the presence of backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC) detector, a TPC filled with CF{sub 4} gas at low pressure (0.1 atm). Using this detector, we have measured the vector direction (head-tail) of nuclear recoils down to energies of 100 keV with an angular resolution of {<=}15 deg. To study our detector backgrounds, we have operated in a basement laboratory on the MIT campus for several months. We are currently building a new, high-radiopurity detector for deployment underground at the Waste Isolation Pilot Plant facility in New Mexico.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗