At least 1,621 records · Page 90

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study of Envelope Sealing in Existing Multiunit Structures

This report describes envelope air sealing that was included in the retrofit of a 244 unit low-rise multifamily housing complex in Durham, N.C. On average, total leakage was reduced by nearly half, from 19.7 ACH50 to 9.4 ACH50. Important air leakage locations identified included plumbing and electrical penetrations, dropped ceilings/soffits, windows, ducts and wall-to-floor intersections. Specifications and a pictorial guide were developed for contractors performing the work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Wall Evaluation for Ten New Construction Homes in Wyandotte, Michigan

The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. This report details the design and construction of 10 new houses in the program. Wyandotte is part of a Michigan State Housing Development Authority-lead consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district GSHP system to service the project. This draft report examines the energy efficiency recommendations for new construction at these homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Process and Market Evaluation: Better Buildings Neighborhood Program

This document presents the preliminary process and market evaluation of the U.S. Department of Energy’s (DOE) Better Buildings Neighborhood Program (BBNP). The document was prepared in partial fulfillment of a contract with the Lawrence Berkeley National Laboratory to conduct a comprehensive program assessment of BBNP. BBNP is one of many programs funded through the American Recovery and Reinvestment Act of 2009. The funding initially targeted city and state governments, local neighborhood associations, nonprofits, colleges and universities, utilities, and financial institutions through the competitive Energy Efficiency and Conservation Block Grant program Retrofit Ramp-Up Solicitation. Initially DOE made 25 awards to local governmental or nonprofit organizations in amounts ranging from $1.2 to $40 million. Nine similar grantees from the Formula Energy Efficiency and Conservation Block Grant program and seven from the State Energy Program solicitation resulted in 41 Better Building grantees, with award allocations of $508,302,786 in funding for Better Buildings projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of Commercial Building Partnerships in Higher Education

Higher education uses less energy per square foot than most commercial building sectors. However, higher education campuses house energy-intensive laboratories and data centers that may spend more than this average; laboratories, in particular, are disproportionately represented in the higher education sector. The Commercial Building Partnership (CBP), a public/private, cost-shared program sponsored by the U.S. Department of Energy (DOE), paired selected commercial building owners and operators with representatives of DOE, its national laboratories, and private-sector technical experts. These teams explored energy-saving measures across building systems–including some considered too costly or technologically challenging–and used advanced energy modeling to achieve peak whole-building performance. Modeling results were then included in new construction or retrofit designs to achieve significant energy reductions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ductless Mini-Split Heat Pump Comfort Evaluation

Field tests were conducted in two homes in Austin, TX, to evaluate the comfort performance of ductless minisplit heat pumps (DMSHPs), measuring temperature and relative humidity measurements in four rooms in each home before and after retrofitting a central HVAC system with DMSHPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Exploratory Study: Recessed Troffer Lighting

This CALiPER study examines the problems and benefits likely to be encountered with LED products intended to replace linear fluorescent lamps. LED dedicated troffers, replacement tubes, and non-tube retrofit kits were evaluated against fluorescent benchmark troffers in a simulated office space for photometric distribution, uniformity of light on the task surface, suitability of light output, flicker, dimming performance, color quality, power quality, safety and certification issues, ease of installation, energy efficiency, and life-cycle cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Envelope Leakage in Attached Dwellings

The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation

This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define "explicit" input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Roof-Only Air Sealing and Insulation Strategies on 1 ½-Story Homes in Cold Climates

The External Thermal and Moisture Management System (ETMMS), typically seen in deep energy retrofits, is a valuable approach for the roof-only portions of existing homes, particularly the 1 ½-story home. It is effective in reducing energy loss through the building envelope, improving building durability, reducing ice dams, and providing opportunities to improve occupant comfort and health.

1 ½-Story House↗

Residential Mechanical Precooling

This research conducted by the Alliance for Residential Building Innovation team evaluated mechanical air conditioner pre-cooling strategies in homes throughout the United States. EnergyPlus modeling evaluated two homes with different performance characteristics in seven climates. Results are applicable to new construction homes and most existing homes built in the last 10 years, as well as fairly efficient retrofitted homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: LED System Performance in a Trial Installation--One Year Later, Yuma Border Patrol, Yuma, Arizona

Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial demonstration in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations at the Yuma Sector Border Patrol Area in Yuma, Arizona. The retrofit was documented to better understand LED technology performance in high-temperature environments. This report follows the GATEWAY Yuma Phase 1.0 Report and reflects LED system results documented one year after the demonstration began.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Indoor Air Quality in 24 California Residences Designed as High-Performance Homes

Today’s high performance green homes are reaching previously unheard of levels of airtightness and are using new materials, technologies and strategies, whose impacts on Indoor Air Quality (IAQ) cannot be fully anticipated from prior studies. This research study used pollutant measurements, home inspections, diagnostic testing and occupant surveys to assess IAQ in 24 new or deeply retrofitted homes designed to be high performance green buildings in California.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pumped Storage and Potential Hydropower from Conduits (Report to Congress)

Th is Congressional Report, Pumped Storage Hydropower and Potential Hydropower from Conduits, addresses the technical flexibility that existing pumped storage facilities can provide to support intermittent renewable energy generation. This study considered potential upgrades or retrofit of these facilities, the technical potential of existing and new pumped storage facilities to provide grid reliability benefits, and the range of conduit hydropower opportunities available in the United States.

13 HYDRO ENERGY↗

Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

1 1/2 story bungalow↗

CALiPER Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers

Although lensed troffers are numerous, there are many other types of optical systems as well. This report looks at the performance of three linear (T8) LED lamps—chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles)—as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pulse compressor with aberration correction

In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete pulse compressor. The simulations reveal that the mirror pulse compressor can reduce the temporal spread of UEDs and DTEMs to the sub-100 femtosecond level for practical electron bunch sizes. EOI’s pulse compressors can be designed and built to attach to different types of UEDs and DTEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales to advance material science research in the field of nanotechnology as well as biomedical research.

47 OTHER INSTRUMENTATION↗