Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Multi-stage heat release of multi-component fuels: Insights and implications for advanced engine operation

Multi-stage heat release (MSHR) is a unique phenomenon typically seen in lean/diluted and low- to intermediate-temperature combustion. Despite its relevance to advanced engine operation, the MSHR of multi-component fuels has barely been quantified. This study aims to characterize the MSHR of multi-component fuels in a rapid compression machine (RCM) at conditions representative of advanced combustion engines. New experimental data are first reported in the RCM at an equivalence ratio of 0.4, pressure of 60 bar and temperatures from 702 to 795 K for a research grade, multi-component gasoline surrogate, termed PACE-20. Here, experiments confirm the existence of MSHR for PACE-20 at all temperatures, and reveal the strong inhibiting effect of temperature on MSHR, where increasing temperature inhibits MSHR by suppressing first stage heat release and promoting second and third stage heat release. A detailed chemical kinetic model is also adopted to model the experiments, with good agreement observed. The response of MSHR characteristics to changes in different engine operating parameters (i.e., temperature, pressure, equivalence ratio and CO 2 dilution level) and fuel compositions (i.e., mole fraction of n-pentane, n-heptane, isooctane, cyclopentane, 1-hexene, ethanol and aromatics in PACE-20) is further evaluated via statistical analysis coupling quasi-random sampling, extensive computer experiments and high-dimensional model representation. The change in MSHR is characterized through 8 quantities of interest (QOIs), i.e., duration and extent of each heat release stage, and their standard deviations. The analysis highlights the dependence of the QOIs on the individual parameters as well as their interplays, with temperature exhibiting the strongest impact among all parameters. Furthermore, it is demonstrated that if MSHR is to be facilitated and combustion phasing is to be extended to enable engine operation at higher compression ratios, it is recommended to operate the engine at low intake temperatures, boosted intake pressures and high CO 2 dilutions (i.e., high EGR levels) with gasoline fuels containing more n-pentane and less aromatics.

42 ENGINEERING↗

Third-body stabilization of supercritical CO 2 in CO oxidation: development and application of a ReaxFF force field for the CO/O/CO 2 system

Supercritical CO 2 (scCO 2 ) plays a crucial role as a solvent in separation processes, advanced power cycles, and materials processing. Nonetheless, the atomistic comprehension of how the dense scCO 2 matrix influences the fundamental reaction of carbon monoxide (CO) is still insufficiently explored. Experimental studies and molecular dynamics (MD) simulations frequently fail to detect the highly reactive, transient intermediates, such as atomic oxygen (O), that drive these reactions. Here, to address this issue, we have developed a novel ReaxFF reactive force field for the CO 2 /CO/O system. The force field parameters were calibrated using density functional theory and second-order Møller-Plesset calculations to model CO 2 crystal properties, intermolecular interactions, bond dissociation curves, and reaction energy barriers. The force field reproduces the cohesive energy of the CO 2 crystal, the pressure characteristics of bulk scCO 2 , the equation-of-state behavior over a wide pressure–density range, the pressure dependence of the C–O bond length under compression, and the structural properties of liquid and scCO 2 , as documented by experiments, ab-initio MD, and prominent non-reactive models. The force field was subsequently applied to study the CO + O → CO 2 reaction. In a dilute environment, the reaction is inefficient as the newly formed CO 2 rapidly dissociates due to excess kinetic and potential energy acquired from the exothermic reaction. Conversely, in a dense scCO 2 environment, the surrounding matrix acts as an efficient third body, stabilizing the emerging CO2 product via molecular collisions. Statistical analysis confirms an average excess energy dissipation of 133.9 ± 3.6 kcal/mol over 112.4 ± 17.9 ps. Kinetic energy decomposition reveals that ∼ 92% of the excess kinetic energy is stored in internal (rotational and vibrational) degrees of freedom. This ReaxFF force field establishes a mechanistic foundation for third-body stabilization in dense reactive environments.

Chowdhury, Emdadul Haque [Pennsylvania State Univ.↗

Refined views of ancient ocean chemistry: Tracking trace element incorporation in pyrite framboids using atom probe tomography

The trace element chemistry of pyrite can be used to determine the origin, timing, and conditions of formation of ore deposits; as a vectoring tool for mineral exploration; and to determine the evolution of the Earth’s oceanic and atmospheric chemistry. However, little is known about whether trace elements are held with the pyrite structure or within nano-inclusions of other phases. This distinction is important for two primary reasons. First, trace element incorporation into the pyrite structure can affect the partitioning of other trace elements. Second, if trace elements are held within nano-inclusions, the partition coefficient of the mineral phases that make up the nano-inclusion, rather than pyrite, are the critical consideration in related interpretations. Previous studies addressing this topic have used laser ablation inductively coupled plasma mass spectrometry; however, the resulting data do not provide sufficient spatial resolution to delineate trace element distributions unless the inclusions are large. Further, they use these flat element profiles in time resolved laser ablation output graphs to argue that pyrite trace element content provides a direct relationship between trace element content of seawater and pyrite trace element content. To improve resolution, we have used atom probe tomography to characterize trace element distributions in pyrite framboids from the Cariaco Basin and Demerara Rise in three-dimensions at sub-nanometer resolution. Manganese was found to be concentrated in the pyrite nanocrystal part of the original framboid structure. In contrast, Ni was mostly found along the grain boundary, though it still appeared to be contained within the pyrite structure. Copper was concentrated in later pyrite overgrowths, and As varied in its location. These observations suggest that some important trace elements are incorporated into pyrite during early diagenesis, even in euxinic settings dominated by water-column pyrite formation. Statistical analysis was used to determine whether trace elements were incorporated in the lattice or within nanoscale inclusions (referred to here are nano-inclusions). We found that As, Ni, Cu, and Mn were commonly held within the pyrite structure, but As, Ni, and Cu can also be held as nano-inclusions or within grain interfaces. Incorporation of As is known to enhance the incorporation of other trace elements and in this case appears to correlated to elevated Ni and Cu concentrations in the Cariaco Basin samples. Furthermore, understanding these relationships strongly impacts our ability to utilize pyrite trace metal concentrations to analyze and quantify early ocean chemistry and its evolution through time.

54 ENVIRONMENTAL SCIENCES↗

Developing a robust geochemical and reactive transport model to evaluate possible sources of arsenic at the CO[subscript 2] sequestration natural analog site in Chimayo, New Mexico

Migration of carbon dioxide (CO{sub 2}) from deep storage formations into shallow drinking water aquifers is a possible system failure related to geologic CO{sub 2} sequestration. A CO{sub 2} leak may cause mineral precipitation/dissolution reactions, changes in aqueous speciation, and alteration of pH and redox conditions leading to potential increases of trace metal concentrations above EPA National Primary Drinking Water Standards. In this study, the Chimayo site (NM) was examined for site-specific impacts of shallow groundwater interacting with CO{sub 2} from deep storage formations. Major ion and trace element chemistry for the site have been previously studied. This work focuses on arsenic (As), which is regulated by the EPA under the Safe Drinking Water Act and for which some wells in the Chimayo area have concentrations higher than the maximum contaminant level (MCL). Statistical analysis of the existing Chimayo groundwater data indicates that As is strongly correlated with trace metals U and Pb indicating that their source may be from the same deep subsurface water. Batch experiments and materials characterization, such as: X-ray diffraction (XRD), scanning electron microscopy (SEM), and synchrotron micro X-ray fluorescence ({mu}-XRF), were used to identify As association with Fe-rich phases, such as clays or oxides, in the Chimayo sediments as the major factor controlling As fate in the subsurface. Batch laboratory experiments with Chimayo sediments and groundwater show that pH decreases as CO{sub 2} is introduced into the system and buffered by calcite. The introduction of CO{sub 2} causes an immediate increase in As solution concentration, which then decreases over time. A geochemical model was developed to simulate these batch experiments and successfully predicted the pH drop once CO{sub 2} was introduced into the experiment. In the model, sorption of As to illite, kaolinite and smectite through surface complexation proved to be the key reactions in simulating the drop in As concentration as a function of time in the batch experiments. Based on modeling, kaolinite precipitation is anticipated to occur during the experiment, which allows for additional sorption sites to form with time resulting in the slow decrease in As concentration. This mechanism can be viewed as trace metal 'scavenging' due to sorption caused secondary mineral precipitation. Since deep geologic transport of these trace metals to the shallow subsurface by brine or CO{sub 2} intrusion is critical to assessing environmental impacts, the effective retardation of trace metal transport is an important parameter to estimate and it is dependent on multiple coupled reactions. At the field scale, As mobility is retarded due to the influence of sorption reactions, which can affect environmental performance assessment studies of a sequestration site.

54 ENVIRONMENTAL SCIENCES↗

Deformation-induced spatiotemporal fluctuation, evolution and localization of strain fields in a bulk metallic glass

Deformation behavior and local strain evolutions upon loading and unloading of a bulk metallic glass (BMG) were systematically investigated by in situ digital image correlation (DIC). Distinct fluctuations and irreversible local strains were observed before the onset of macroscopic yielding. Statistical analysis shows that these fluctuations might be related to intrinsic structural heterogeneities, and that the evolution history and characteristics of local strain fields play an important role in the subsequent initiation of shear bands. Effects of sample size, pre-strain, and loading conditions were systematically analyzed in terms of the probability distributions of the resulting local strain fields. It is found that a higher degree of local shear strain heterogeneity corresponds to a more ductile stressestrain curve. Implications of these findings are discussed for the design of new materials.

36 MATERIALS SCIENCE↗

A generalized power-law criterion for rocks based on Mohr failure theory

Nonlinearity of Mohr envelopes confirmed by past laboratory test data can be of considerable importance in theoretical interpretation of rock strength behaviors and many practical applications. Current nonlinear failure criteria are introduced with parameters to empirically fit test data, and the physical and mechanical meanings of these fitting parameters are often not known. Predicted strengths by theoretical criteria (e.g., Griffith criterion) generally do not agree well with test data. Considering the nonlinear properties of a Mohr envelope, a nonlinear failure criterion in a generalized power-law form is derived in this paper based on strength magnitude coefficient (a) and failure envelope curvature coefficient (n) which are expressed in terms of uniaxial tensile strength, uniaxial compressive strength, and angle of internal friction. Test data on granite, marble, dolomite, and andesite from published literature were chosen to test the performance of the proposed criterion along with Griffith and Hoek-Brown criteria. Statistical analysis was performed to evaluate the application of different criteria in predicting the strength of rocks. In addition, some Griffith-typed criteria are mathematically shown to be the special cases of the proposed criterion. The proposed and Hoek-Brown criteria have similar power-law forms with a significant difference in the coefficient functions that govern the shear strength magnitude of rock. The different tensile and compressive failure mechanisms are also investigated from the perspective of the relationship between the uniaxial tension Mohr circle and the proposed failure envelope.

58 GEOSCIENCES↗

Stereotactic Body Radiation Therapy for Liver Tumors: Impact of Daily Setup Corrections and Day-to-Day Anatomic Variations on Dose in Target and Organs at Risk

Purpose: To assess day-to-day differences between planned and delivered target volume (TV) and organ-at-risk (OAR) dose distributions in liver stereotactic body radiation therapy (SBRT), and to investigate the dosimetric impact of setup corrections. Methods and Materials: For 14 patients previously treated with SBRT, the planning CT scan and three treatment scans (one for each fraction) were included in this study. For each treatment scan, two dose distributions were calculated: one using the planned setup for the body frame (no correction), and one using the clinically applied (corrected) setup derived from measured tumor displacements. Per scan, the two dose distributions were mutually compared, and the clinically delivered distribution was compared with planning. Doses were recalculated in equivalent 2-Gy fraction doses. Statistical analysis was performed with the linear mixed model. Results: With setup corrections, the mean loss in TV coverage relative to planning was 1.7%, compared with 6.8% without corrections. For calculated equivalent uniform doses, these figures were 2.3% and 15.5%, respectively. As for the TV, mean deviations of delivered OAR doses from planning were small (between -0.4 and +0.3 Gy), but the spread was much larger for the OARs. In contrast to the TV, the mean impact of setup corrections on realized OAR doses was close to zero, with large positive and negative exceptions. Conclusions: Daily correction of the treatment setup is required to obtain adequate TV coverage. Because of day-to-day patient anatomy changes, large deviations in OAR doses from planning did occur. On average, setup corrections had no impact on these doses. Development of new procedures for image guidance and adaptive protocols is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Spatial Uncertainties in the Radiotherapy Process With the Novalis System

Purpose: The purpose of this study was to evaluate the accuracy of a new version of the ExacTrac X-ray (ETX) system with statistical analysis retrospectively in order to determine the tolerance of systematic components of spatial uncertainties with the Novalis system. Methods and Materials: Three factors of geometrical accuracy related to the ETX system were evaluated by phantom studies. First, location dependency of the detection ability of the infrared system was evaluated. Second, accuracy of the automated calculation by the image fusion algorithm in the patient registration software was evaluated. Third, deviation of the coordinate scale between the ETX isocenter and the mechanical isocenter was evaluated. From the values of these examinations and clinical experiences, the total spatial uncertainty with the Novalis system was evaluated. Results: As to the location dependency of the detection ability of the infrared system, the detection errors between the actual position and the detected position were 1% in translation shift and 0.1{sup o} in rotational angle, respectively. As to the accuracy of patient verification software, the repeatability and the coincidence of the calculation value by image fusion were good when the contrast of the X-ray image was high. The deviation of coordinates between the ETX isocenter and the mechanical isocenter was 0.313 {+-} 0.024 mm, in a suitable procedure. Conclusions: The spatial uncertainty will be less than 2 mm when suitable treatment planning, optimal patient setup, and daily quality assurance for the Novalis system are achieved in the routine workload.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combination of the Pro-Apoptotic TRAIL-Receptor Antibody Mapatumumab With Ionizing Radiation Strongly Increases Long-Term Tumor Control Under Ambient and Hypoxic Conditions

Purpose: Mapatumumab, an agonistic tumor necrosis factor-related apoptosis inducing ligand-receptor antibody, exerts highly synergistic apoptotic effects in vitro and in short-term growth delay assays when combined with irradiation. Because it remained unclear in how far these effects influence local tumor control, long-term experiments using a colorectal xenograft model were undertaken. Material and Methods: Experiments were performed with irradiation (5 x 3 Gy, d1-5) and mapatumumab (10 mg/kg) in Colo205-xenograft-bearing NMRI (nu/nu) nude mice. Graded top up doses were delivered on the tumor-bearing hind leg under ambient and hypoxic conditions; follow-up was 270 days. Growth delay and local tumor control were end points of the study. Statistical analysis of the experiments included calculation of tumor regrowth and local tumor control. Results: After combined treatment, a pronounced tumor regrowth-delay was observed when compared with irradiation alone. Long-term experiments revealed a highly significant increase in local tumor control for ambient (p = 0.00076) and hypoxic treatment (p = 0.000069). Conclusions: The present data demonstrate for the first time that combination of a pro-apoptotic antibody with irradiation results in evidently reduced tumor regrowth times and subsequently highly increased local tumor control under normoxic and hypoxic conditions in a xenograft mouse model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Acute Locoregional Toxicity in Patients With Breast Cancer Treated With Adjuvant Radiotherapy in Combination With Bevacizumab

Purpose: Preclinical studies have shown that bevacizumab combined with radiotherapy (RT) induces a radiosensitizing effect. Published reports regarding the safety of combination therapy involving bevacizumab and RT are lacking. The purpose of this study was to analyze acute locoregional toxicity in patients with breast cancer receiving concurrent bevacizumab plus RT. Methods and Materials: After institutional review board approval was obtained, patients with breast cancer who received bevacizumab were identified; these patients were then cross-referenced with patients receiving RT. Toxicity was scored by the Common Terminology Criteria for Adverse Events. Patients were matched 1:1 with those who did not receive bevacizumab. Statistical analysis was performed to analyze toxicity between the two groups. Results: Fourteen patients were identified to have received bevacizumab plus RT. All patients receivedbevacizumab during RT without delay or treatment breaks; there were no RT treatment breaks in all patients. No patient receiving bevacizumab plus RT experienced {>=}Grade 3 toxicity; 3 matched control patients experienced a Grade 3 skin reaction. There was no difference in fatigue, radiation fibrosis, pneumonitis, or lymphedema between the two groups. Five patients (35%) developed reduction in ejection fraction; 2 with right-sided and 3 with left-sided treatment. Patients with left-sided treatment experienced a persistent reduction in ejection fraction compared with those receiving right-sided treatment. Conclusion: Concurrent bevacizumab and RT did not increase acute locoregional toxicity in comparison with matched control patients who did not receive RT alone. The addition of concurrent RT when treating the intact breast, chest wall, and associated nodal regions in breast cancer seems to be safe and well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcomes and Patterns of Failure After Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

Purpose: To study and report the clinical outcomes and patterns of failure after intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC). Methods and Materials: The treatment outcomes of NPC patients treated with IMRT at Pamela Youde Nethersole Eastern Hospital between 2005 and 2007 were reviewed. The location and extent of locoregional failures were transferred to the pretreatment planning computed tomography for dosimetry analysis. Statistical analyses were performed on dose coverage and locoregional failures. Results: A total of 193 NPC patients were analyzed; 93% had Stage III/IV disease. Median follow-up was 30 months. Overall disease failure (at any site) developed in 35 patients. Among these, there were 23 distant metastases, 16 local failures, and 9 regional failures. Four of the locoregional failures were marginal. Dose conformity with IMRT was excellent. Patients with at least 66.5 Gy to their target volumes had significantly less locoregional failure. The 2-year local progression-free, regional progression-free, distant metastasis-free, and overall survival rates were 95%, 96%, 90%, and 92%, respectively. Conclusions: Intensity-modulated radiotherapy provides excellent locoregional control for NPC. Distant metastasis remains the most difficult challenge, and more effective systemic agents should be explored for patients presenting with advanced locoregional diseases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcome and Prognostic Factors of Radiation Therapy for Medulloblastoma

Purpose: To investigate treatment outcome and prognostic factors after radiation therapy in patients with medulloblastomas (MB). Methods and Materials: Sixty-six patients with histologically confirmed MB were treated at University Hospital of Heidelberg between 1985 and 2009. Forty-two patients (64%) were pediatric ({<=}18 years), and 24 patients (36%) were adults. Tumor resection was performed in all patients and was complete in 47%. All patients underwent postoperative craniospinal irradiation (CSI) delivering a median craniospinal dose of 35.5 Gy with additional boosts to the posterior fossa up to 54.0 Gy. Forty-seven patients received chemotherapy, including 21 in whom chemotherapy was administered before CSI. Statistical analysis was performed using the log-rank test and the Kaplan-Meier method. Results: Median follow-up was 93 months. Overall survival (OS) and local and distant progression-free survival (LPFS and DPFS) were 73%, 62%, and 77% at 60 months. Both local and distant recurrence predisposed for significantly reduced OS. Macroscopic complete tumor resection, desmoplastic histology and early initiation of postoperative radiation therapy within 28 days were associated with improved outcome. The addition of chemotherapy did not improve survival rates. Toxicity was moderate. Conclusions: Complete resection of MB followed by CSI yields long survival rates in both children and adults. Delayed initiation of CSI is associated with poor outcome. Desmoplastic histology is associated with improved survival. The role of chemotherapy, especially in the adult population, must be further investigated in clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Benefits of Intensity-Modulated Radiotherapy Combined With the Deep-Inspiration Breath-Hold Technique in Patients With Mediastinal Hodgkin's Lymphoma

Purpose: To assess the additional benefits of using the deep-inspiration breath-hold (DIBH) technique with intensity-modulated radiotherapy (IMRT) in terms of the protection of organs at risk for patients with mediastinal Hodgkin's disease. Methods and Materials: Patients with early-stage Hodgkin's lymphoma with mediastinal involvement were entered into the study. Two simulation computed tomography scans were performed for each patient: one using the free-breathing (FB) technique and the other using the DIBH technique with a dedicated spirometer. The clinical target volume, planning target volume (PTV), and organs at risk were determined on both computed tomography scans according to the guidelines of the European Organization for Research and Treatment of Cancer. In both cases, 30 Gy in 15 fractions was prescribed. The dosimetric parameters retrieved for the statistical analysis were PTV coverage, mean heart dose, mean coronary artery dose, mean lung dose, and lung V20. Results: There were no significant differences in PTV coverage between the two techniques (FB vs. DIBH). The mean doses delivered to the coronary arteries, heart, and lungs were significantly reduced by 15% to 20% using DIBH compared with FB, and the lung V20 was reduced by almost one third. The dose reduction to organs at risk was greater for masses in the upper part of the mediastinum. IMRT with DIBH was partially implemented in 1 patient. This combination will be extended to other patients in the near future. Conclusions: Radiation exposure of the coronary arteries, heart, and lungs in patients with mediastinal Hodgkin's lymphoma was greatly reduced using DIBH with IMRT. The greatest benefit was obtained for tumors in the upper part of the mediastinum. The possibility of a wider use in clinical practice is currently under investigation in our department.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Predictors of Radiation-induced Acute Nausea and Vomiting in IMRT for Nasopharyngeal Cancer

Purpose: We wanted to investigate dosimetric parameters that would predict radiation-induced acute nausea and vomiting in intensity-modulated radiation therapy (IMRT) for undifferentiated carcinoma of the nasopharynx (NPC). Methods and Materials: Forty-nine consecutive patients with newly diagnosed NPC were treated with IMRT alone in this prospective study. Patients receiving any form of chemotherapy were excluded. The dorsal vagal complex (DVC) as well as the left and right vestibules (VB-L and VB-R, respectively) were contoured on planning computed tomography images. A structure combining both the VB-L and the VB-R, named VB-T, was also generated. All structures were labeled organs at risk (OAR). A 3-mm three-dimensional margin was added to these structures and labeled DVC+3 mm, VB-L+3 mm, VB-R+3 mm, and VB-T+3 mm to account for physiological body motion and setup error. No weightings were given to these structures during optimization in treatment planning. Dosimetric parameters were recorded from dose-volume histograms. Statistical analysis of parameters' association with nausea and vomiting was performed using univariate and multivariate logistic regression. Results: Six patients (12.2%) reported Grade 1 nausea, and 8 patients (16.3%) reported Grade 2 nausea. Also, 4 patients (8.2%) complained of Grade 1 vomiting, and 4 patients (8.2%) experienced Grade 2 vomiting. No patients developed protracted nausea and vomiting after completion of IMRT. For radiation-induced acute nausea, V40 (percentage volume receiving at least 40Gy) to the VB-T and V40>=80% to the VB-T were predictors, using univariate analysis. On multivariate analysis, V40>=80% to the VB-T was the only predictor. There were no predictors of radiation-induced acute vomiting, as the number of events was too small for analysis. Conclusions: This is the first study demonstrating that a V40 to the VB-T is predictive of radiation-induced acute nausea. The vestibules should be labeled as sensitive OARs, and weightings should be considered for dose sparing during optimization in the treatment planning of IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Computed Tomography Image Quality on Image-Guided Radiation Therapy Based on Soft Tissue Registration

Purpose: In image-guided radiation therapy (IGRT), different computed tomography (CT) modalities with varying image quality are being used to correct for interfractional variations in patient set-up and anatomy changes, thereby reducing clinical target volume to the planning target volume (CTV-to-PTV) margins. We explore how CT image quality affects patient repositioning and CTV-to-PTV margins in soft tissue registration-based IGRT for prostate cancer patients. Methods and Materials: Four CT-based IGRT modalities used for prostate RT were considered in this study: MV fan beam CT (MVFBCT) (Tomotherapy), MV cone beam CT (MVCBCT) (MVision; Siemens), kV fan beam CT (kVFBCT) (CTVision, Siemens), and kV cone beam CT (kVCBCT) (Synergy; Elekta). Daily shifts were determined by manual registration to achieve the best soft tissue agreement. Effect of image quality on patient repositioning was determined by statistical analysis of daily shifts for 136 patients (34 per modality). Inter- and intraobserver variability of soft tissue registration was evaluated based on the registration of a representative scan for each CT modality with its corresponding planning scan. Results: Superior image quality with the kVFBCT resulted in reduced uncertainty in soft tissue registration during IGRT compared with other image modalities for IGRT. The largest interobserver variations of soft tissue registration were 1.1 mm, 2.5 mm, 2.6 mm, and 3.2 mm for kVFBCT, kVCBCT, MVFBCT, and MVCBCT, respectively. Conclusions: Image quality adversely affects the reproducibility of soft tissue-based registration for IGRT and necessitates a careful consideration of residual uncertainties in determining different CTV-to-PTV margins for IGRT using different image modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive Factors and Management of Rectal Bleeding Side Effects Following Prostate Cancer Brachytherapy

Purpose: To report on the incidence, nature, and management of rectal toxicities following individual or combination brachytherapy following treatment for prostate cancer over a 17-year period. We also report the patient and treatment factors predisposing to acute ≥grade 2 proctitis. Methods and Materials: A total of 2752 patients were treated for prostate cancer between October 1990 and April 2007 with either low-dose-rate brachytherapy alone or in combination with androgen depletion therapy (ADT) or external beam radiation therapy (EBRT) and were followed for a median of 5.86 years (minimum 1.0 years; maximum 19.19 years). We investigated the 10-year incidence, nature, and treatment of acute and chronic rectal toxicities following BT. Using univariate, and multivariate analyses, we determined the treatment and comorbidity factors predisposing to rectal toxicities. We also outline the most common and effective management for these toxicities. Results: Actuarial risk of ≥grade 2 rectal bleeding was 6.4%, though notably only 0.9% of all patients required medical intervention to manage this toxicity. The majority of rectal bleeding episodes (72%) occurred within the first 3 years following placement of BT seeds. Of the 27 patients requiring management for their rectal bleeding, 18 underwent formalin treatment and nine underwent cauterization. Post-hoc univariate statistical analysis revealed that coronary artery disease (CAD), biologically effective dose, rectal volume receiving 100% of the prescription dose (RV100), and treatment modality predict the likelihood of grade ≥2 rectal bleeding. Only CAD, treatment type, and RV100 fit a Cox regression multivariate model. Conclusions: Low-dose-rate prostate brachytherapy is very well tolerated and rectal bleeding toxicities are either self-resolving or effectively managed by medical intervention. Treatment planning incorporating adjuvant ADT while minimizing RV100 has yielded the best toxicity-free survival following BT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Similar Survival for Patients Undergoing Reduced-Intensity Total Body Irradiation (TBI) Versus Myeloablative TBI as Conditioning for Allogeneic Transplant in Acute Leukemia

Purpose: Hematopoietic stem cell transplantation (HSCT) is the mainstay of treatment for adults with acute leukemia. Total body irradiation (TBI) remains an important part of the conditioning regimen for HCST. For those patients unable to tolerate myeloablative TBI (mTBI), reduced intensity TBI (riTBI) is commonly used. In this study we compared outcomes of patients undergoing mTBI with those of patients undergoing riTBI in our institution. Methods and Materials: We performed a retrospective review of all patients with acute leukemia who underwent TBI-based conditioning, using a prospectively acquired database of HSCT patients treated at our institution. Patient data including details of the transplantation procedure, disease status, Karnofsky performance status (KPS), response rates, toxicity, survival time, and time to progression were extracted. Patient outcomes for various radiation therapy regimens were examined. Descriptive statistical analysis was performed. Results: Between June 1985 and July 2012, 226 patients with acute leukemia underwent TBI as conditioning for HSCT. Of those patients, 180 had full radiation therapy data available; 83 had acute lymphoblastic leukemia and 94 had acute myelogenous leukemia; 45 patients received riTBI, and 135 received mTBI. Median overall survival (OS) was 13.7 months. Median relapse-free survival (RFS) for all patients was 10.2 months. Controlling for age, sex, KPS, disease status, and diagnosis, there were no significant differences in OS or RFS between patients who underwent riTBI and those who underwent mTBI (P=.402, P=.499, respectively). Median length of hospital stay was shorter for patients who received riTBI than for those who received mTBI (16 days vs 23 days, respectively; P<.001), and intensive care unit admissions were less frequent following riTBI than mTBI (2.22% vs 12.69%, respectively, P=.043). Nonrelapse survival rates were also similar (P=.186). Conclusions: No differences in OS or RFS were seen between all patients undergoing riTBI and those undergoing mTBI, despite older age and potential increased comorbidity of riTBI patients. riTBI regimens were associated with shorter length of hospital stay, fewer intensive care unit admissions, and similar rates of nonrelapse survival, which may reflect reduced toxicity. Prospective trials comparing riTBI and mTBI are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Importance of Local Control in Early-Stage Prostate Cancer: Outcomes of Patients With Positive Post-Radiation Therapy Biopsy Results Treated in RTOG 9408

Purpose: The purpose of this study was to assess the association between positive post-radiation therapy (RT) biopsy results and subsequent clinical outcomes in males with localized prostate cancer. Methods and Materials: Radiation Therapy Oncology Group study 94-08 analyzed 1979 males with prostate cancer, stage T1b-T2b and prostate-specific antigen concentrations of ≤20 ng/dL, to investigate whether 4 months of total androgen suppression (TAS) added to RT improved survival compared to RT alone. Patients randomized to receive TAS received flutamide with luteinizing hormone releasing hormone (LHRH) agonist. According to protocol, patients without evidence of clinical recurrence or initiation of additional endocrine therapy underwent repeat prostate biopsy 2 years after RT completion. Statistical analysis was performed to evaluate the impact of positive post-RT biopsy results on clinical outcomes. Results: A total of 831 patients underwent post-RT biopsy, 398 were treated with RT alone and 433 with RT plus TAS. Patients with positive post-RT biopsy results had higher rates of biochemical failure (hazard ratio [HR] = 1.7; 95% confidence interval [CI] = 1.3-2.1) and distant metastasis (HR = 2.4; 95% CI = 1.3-4.4) and inferior disease-specific survival (HR = 3.8; 95% CI = 1.9-7.5). Positive biopsy results remained predictive of such outcomes after correction for potential confounders such as Gleason score, tumor stage, and TAS administration. Prior TAS therapy did not prevent elevated risk of adverse outcome in the setting of post-RT positive biopsy results. Patients with Gleason score ≥7 with a positive biopsy result additionally had inferior overall survival compared to those with a negative biopsy result (HR = 1.56; 95% CI = 1.04-2.35). Conclusions: Positive post-RT biopsy is associated with increased rates of distant metastases and inferior disease-specific survival in patients treated with definitive RT and was associated with inferior overall survival in patients with high-grade tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗