Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Use of ruthenium dyes for subnanosecond detector fidelity testing in real time transient absorption

Transient absorption spectroscopy is a powerful tool for the study of photoreactions on time scales from femtoseconds to seconds. Typically, reactions slower than {approx}1 ns are recorded by the ''classical'' technique; the reaction is triggered by an excitation flash, and absorption changes accompanying the reaction are recorded in real time using a continuous monitoring light beam and a detection system with sufficiently fast response. The pico- and femtosecond region can be accessed by the more recent ''pump-probe'' technique, which circumvents the difficulties of real time detection on a subnanosecond time scale. This is paid for by accumulation of an excessively large number of shots to sample the reaction kinetics. Hence, it is of interest to extend the classical real time technique as far as possible to the subnanosecond range. In order to identify and minimize detection artifacts common on a subnanosecond scale, like overshoot, ringing, and signal reflections, rigorous testing is required of how the detection system responds to fast changes of the monitoring light intensity. Here, we introduce a novel method to create standard signals for detector fidelity testing on a time scale from a few picoseconds to tens of nanoseconds. The signals result from polarized measurements of absorption changes upon excitation of ruthenium complexes {l_brace}[Ru(bpy){sub 3}]{sup 2+} and a less symmetric derivative{r_brace} by a short laser flash. Two types of signals can be created depending on the polarization of the monitoring light with respect to that of the excitation flash: a fast steplike bleaching at magic angle and a monoexponentially decaying bleaching for parallel polarizations. The lifetime of the decay can be easily varied via temperature and viscosity of the solvent. The method is applied to test the performance of a newly developed real time transient absorption setup with 300 ps time resolution and high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digitization Best Practices [Poster]

This project involved performing tests and documenting results to determine best practices for digitizing older print documents. The digitization process is complicated, especially when original documents exhibit non-standard fonts and are faded. Tests focused on solutions to improve high quality scanning, increase OCR accuracy, and efficiently use embedded metadata. Results are summarized. From the test results on the right sides, we know that when we plan to digitize documents, we should balance Quantity and Quality based on our expectation, and then make final decision for the digitization process.

99 GENERAL AND MISCELLANEOUS↗

Zero-CO Residential Natural Gas Furnace

Residential natural gas furnaces are widely used in the US homes. Manufacturers dedicate significant design and testing resources to meet requirements of design standards. One area of these standards is controlling flue gas carbon monoxide (CO) emissions. To more effectively reduce CO emissions at the flue, we developed a novel catalyst-assisted approach that integrated a low Pt/Rh loading acidic gas reduction (AGR) catalyst with three-way catalyst (TWC) or diesel oxidation catalyst (DOC) components. Compact catalysts were fabricated and assembled into tubular components, which can be seamlessly incorporated into the primary heat exchanger of a representative commercially available condensing furnace. The retrofitted furnace was demonstrated and tested following ANSI/ASHRAE Standard 103-2017. Experimental results showed that both AGR/TWC and AGR/DOC configurations achieved near-zero CO emissions under steady-state and cold-start conditions, compared with up to 500 ppm at a cold start and 17 ppm in a steady state in the OEM furnace. The catalyst-assisted furnaces also exhibited an annual fuel utilization efficiency improvement of more than 1.5% relative to the baseline unit, with a manageable pressure drop of 2.0−2.5 in. of water column. These results demonstrate that the catalyst-assisted approach can effectively eliminate CO emissions and improve energy efficiency. The technology has broad applicability for residential and commercial gas-fired heating systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Topical Report Tantalum – 2.5% Tungsten Machinability Testing

Protection Association (NFPA). NFPA 484, Standard for Combustible Metals, Chapter 9 Tantalum and Annex E, supplemental Information on Tantalum require cutting oil be used when machining tantalum because it burns at such a high temperature that it breaks down the water in a water-based metalworking fluid (MWF). The NFPA guide devotes approximately 20 pages to this material. The Kansas City Plant (KCP) uses Fuchs Lubricants Ecocut Base 44 LVC as a MWF. This is a highly chlorinated oil with a high flash point (above 200° F). The chlorine is very helpful in preventing BUE (Built Up Edge) that occurs frequently with this very gummy material. The Ecocut is really a MWF additive that Fuchs uses to add chlorinated fats to other non-chlorinated MWF.

36 MATERIALS SCIENCE↗

Metrology and Standards Gaps and FY27 Work Focusing on Impact

This work focuses on the Heliostat Consortium (HelioCon) optical measurements and characterization, testing and modeling capabilities and infrastructure at NLR and Sandia supporting heliostat technology research, development, validation, and deployment in relevant industries. The development of standards in HelioCon requires a collective effort across the global heliostat community of industry, researchers, academia and other stakeholders.

14 SOLAR ENERGY↗

Electrospun porous La–Sr–Co–Ni–O nanofibers for highly sensitive non-enzymatic glucose detection

Glucose biosensors are widely used for clinical, industrial, and environmental applications. Nonenzymatic electrochemical glucose biosensors based on metal oxides with a perovskite structure have exhibited high sensitivity, excellent stability, and cost efficiency. In this work, porous La–Sr–Co–Ni–O (LSCNO) nanofibers, with an ABO 3 -type perovskite structure, were prepared through optimizing the A-site and B-site elements by electrospinning, followed with calcination at 700 °C for 5 h. Characterized by scanning and transmission electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy, fabricated nanofibers were confirmed to be porous and nanosized polycrystalline grains with high crystallinity. A novel La 0.75 Sr 0.25 Co 0.5 Ni 0.5 O 3 -based nonenzymatic electrochemical biosensor was developed, which is sensitive to glucose because of an electrochemically catalytic mechanism, a mediated electron transfer involving Ni(II)/Ni(III) or Co(II)/Co(III), accompanying with gluconic acid complexation. The glucose biosensor presented a linear response in the range of 0.1–1.0 mM with a calibration sensitivity of 924 ± 28 μA mM –1 , a proportion of the variance of 0.9926, and a lower limit of detection of 0.083 mM, respectively, demonstrating an outstanding analytical performance. The biosensor showed no response to the most widely used anionic surfactant, sodium dodecyl sulfate, and low sensitivity to other biomolecules, such as fructose, lactose, galactose, mannose, dopamine, and ascorbic acid. A urine sample was tested by this novel nonenzymatic electrochemical biosensor by standard addition method, suggesting a potential application for clinical test.

36 MATERIALS SCIENCE↗

Confronting the concordance model of cosmology with Planck data

We confront the concordance (standard) model of cosmology, the spatially flat ΛCDM Universe with power-law form of the primordial spectrum with Planck CMB angular power spectrum data searching for possible smooth deviations beyond the flexibility of the standard model. The departure from the concordance cosmology is modeled in the context of Crossing statistic and statistical significance of this deviation is used as a measure to test the consistency of the standard model to the Planck data. Derived Crossing functions suggest the presence of some broad features in angular spectrum beyond the expectations of the concordance model. Our results indicate that the concordance model of cosmology is consistent to the Planck data only at 2 to 3σ confidence level if we allow smooth deviations from the angular power spectrum given by the concordance model. This might be due to random fluctuations or may hint towards smooth features in the primordial spectrum or departure from another aspect of the standard model. Best fit Crossing functions indicate that there are lack of power in the data at both low-ℓ and high-ℓ with respect to the concordance model. This hints that we may need some modifications in the foreground modeling to resolve the significant inconsistency at high-ℓ. However, presence of some systematics at high-ℓ might be another reason for the deviation we found in our analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and implementation of an in-situ cable condition monitoring method for nuclear power plants - 130

The sustainability of the existing fleet of nuclear power reactors depends on utilities' ability to manage the aging of key components that cannot easily or economically be replaced or upgraded. Cables, metals, and concrete structures are among the major and key components that the industry and government are working on to ensure the long term reliability and safety of nuclear plants. To ensure that these key components continue to meet their performance requirements, new testing and condition monitoring technologies must be developed that are capable of identifying and quantifying degradation in these materials. The work presented in this paper focuses on the development and implementation of an in-situ condition monitoring method for nuclear power plant cables. This cable condition monitoring method is based on the frequency domain reflectometry (FDR) technique, which is a non-destructive in-situ electrical test that uses the principle of transmission line theory to locate and quantify impedance changes in a cable circuit. Through extensive research, development, and validation, the FDR test technique has been adapted as a cable condition monitoring method that trends with increasing cable degradation. In addition, the FDR data has been correlated to the industry standard elongation at break (EAB) test to quantify the degree of localized degradation in nuclear plant cable insulation material caused by long term exposure to high temperatures and radiation. By correlating FDR to EAB, the aging condition of cables routed through harsh environments can be better understood in relation to its ability to perform its intended function. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Power Hardware-in-the-Loop-Based Anti-Islanding Evaluation and Demonstration

The National Renewable Energy Laboratory (NREL) teamed with Southern California Edison (SCE), Clean Power Research (CPR), Quanta Technology (QT), and Electrical Distribution Design (EDD) to conduct a U.S. Department of Energy (DOE) and California Public Utility Commission (CPUC) California Solar Initiative (CSI)-funded research project investigating the impacts of integrating high-penetration levels of photovoltaics (PV) onto the California distribution grid. One topic researched in the context of high-penetration PV integration onto the distribution system is the ability of PV inverters to (1) detect islanding conditions (i.e., when the distribution system to which the PV inverter is connected becomes disconnected from the utility power connection) and (2) disconnect from the islanded system within the time specified in the performance specifications outlined in IEEE Standard 1547. This condition may cause damage to other connected equipment due to insufficient power quality (e.g., over-and under-voltages) and may also be a safety hazard to personnel that may be working on feeder sections to restore service. NREL teamed with the Florida State University (FSU) Center for Advanced Power Systems (CAPS) to investigate a new way of testing PV inverters for IEEE Standard 1547 unintentional islanding performance specifications using power hardware-in-loop (PHIL) laboratory testing techniques.

14 SOLAR ENERGY↗

Quality Assurance of Radiation Therapy Planning Systems: Current Status and Remaining Challenges

Computerized radiation therapy planning systems (RTPSs) are pivotal for treatment planning. The acceptance, commissioning, and quality control of RTPSs are uniquely complex and are described in the American Association of Physicists in Medicine Task Group Report 53 (1998) and International Atomic Energy Agency Technical Report Series No. 430 (2004). The International Atomic Energy Agency also developed a document and data package for use by vendors and purchasers to aid with acceptance testing of RTPSs. This document is based on International Electrotechnical Commission standard 62083 (2000) and describes both 'type' tests to be performed in the factory and 'site' tests to be performed in the clinic. The American Association of Physicists Task Group Report 67 described benchmark tests for the validation of dose calculation algorithms. Test data are being produced with the backing of the U.S. National Cancer Institute. However, significant challenges remain. Technology keeps evolving rapidly, thus requiring new quality assurance (QA) procedures. Intensity-modulated radiation therapy with its use of inverse optimization has added a new dimension to QA, because the results are not intuitively obvious. New technologies such as real-time ultrasound guidance for brachytherapy, TomoTherapy, and Cyberknife, require their own specialized RTPSs with unique QA requirements. On-line imaging allows for the generation of dose reconstructions using image warping techniques to determine the daily dose delivered to the patient. With increasing computer speeds, real-time reoptimization of treatment plans will become a reality. Gating technologies will require four-dimensional dose calculations to determine the actual dose delivered to tissue voxels. With these rapidly changing technologies, it is essential that a strong QA culture is invoked in every institution implementing these procedures and that new protocols are developed as a part of the clinical implementation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fuel Matrix Degradation Model Development Update: Alloy Corrosion Rates and Hydrogen Generation

This work is being performed as part of the DOE NE Spent Fuel and Waste Science and Technology Campaign, Argillite and Crystalline Rock R&D work packages: SF-19AN01030101 and SF-19AN01030201. This document meets the milestone M4SF-19AN010301013 for Argillite R&D and the milestone M4SF-19AN010302013 for Crystalline R&D. The fuel matrix degradation (FMD) model calculates the degradation rate of spent UO2 fuel based on fundamental electrochemical theory and thermodynamics. The model provides the quantitative basis for radionuclide source term predictions in the generic disposal system analysis (GDSA) performance assessment (PA) model. The FMD model has been implemented in a manner that facilitates its integration with the GDSA-PA code and a preliminary, integrated FMD-GDSA model has been successfully tested (Jerden et al., 2017). The specific focus of on-going work is to accurately and quantitatively represent the generation of H2 in a breached waste package and its effect on the spent fuel degradation rate so that this key process can be accurately represented in PA models. It has been shown experimentally that millimolar concentrations of dissolved H2 in contact with spent fuel will inhibit oxidative dissolution and decrease the fuel degradation rates by as much as three orders of magnitude (e.g., Röllin et al., 2001, Ollila, 2008). This will lead to a significant decrease in the radionuclide source term values used in repository PA models. Sensitivity studies using the FMD model have shown that the dissolved H2 concentration is the dominant environmental variable affecting the UO2 spent fuel dissolution rate as long as a source of H2 persists in the breached waste package (Jerden et al., 2015). Therefore, on-going experimental and modeling efforts focus on H2 production, accumulation and interfacial reactions within a breached waste package. The anoxic corrosion of metallic engineering materials within a breached waste package will be the main source of H2 in crystalline and argillite rock repository systems. The most important H2-producing alloys present within a waste package include stainless steel, carbon steel, and aluminum alloys and the Zircaloy fuel cladding. A steel corrosion module was added to the FMD model to account for these H2 sources and couple the H2 generation rate with fuel degradation processes (Jerden et al., 2017). As discussed below, there is a need for experimental data from electrochemical corrosion tests to quantify the H2 generation rates due to the corrosion of these waste package alloys as a function of key environmental variables (Eh, pH, groundwater chemistry). This report presents results from series of electrochemical corrosion tests with materials present in waste packages that provide information needed to parameterize and validate the FMD model. The alloys tested include 316L stainless steel (316SS), AISI 4320 carbon steel (C-steel) and Zircaloy-4 fuel cladding (unirradiated). Potentiodynamic polarization and potentiostatic polarization tests were performed in buffer solutions at pH 4, 7 and 10 with NaCl concentrations of 0, 4 and 100 millimolar (mM). The potentiostatic tests were performed at voltages varying from 0.5 volts down to -0.66 volts, vs the standard hydrogen electrode (SHE), and all tests were performed at laboratory ambient temperatures (~22 °C). The corrosion rates measured during the electrochemical tests were used as direct input to a new FMD/in-package chemistry model that is being developed to provide accurate long-term spent fuel degradation rates as chemical conditions (Eh, pH, speciation) evolve within a breached waste package. This new model was developed by coupling the FMD model with the reactive transport code X1t, which is a module within the Geochemist’s Workbench (GWB) reaction path modeling code (Jerden et al., 2019). The reactive transport model consists of a 1D domain discretized with 21 reaction diffusion cells and includes a single waste packag

Jerden, James↗

Laboratory Evaluation of Energy Recovery Ventilators

Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well. Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates. The use of energy recovery ventilators (ERVs) in tight homes in mixed-humid and hot-humid climates is already practiced. Unbalancing the ERV by reducing exhaust airflows can provide a means to supply makeup air and reduce the level of home depressurization to mitigate these issues, helping to realize the rated performance of the exhaust-only appliances, achieve safe operation of atmospherically vented combustion, provide the necessary level of fresh ventilation air, and/or improve envelope durability. The unbalanced operation of the ERV to address depressurization can obviously result in unintended consequences in other areas, such as further loss of humidity control in homes in more humid climates. In such tight home scenarios, it is expected that ERVs will operate a substantial amount of time in unbalanced mode with much higher supply than exhaust airflows. Although ERV design performance under balanced flow conditions is well documented, there is no information in the public domain that empirically establishes the effect of unbalanced flow on sensible and latent exchange, especially in the now dominant membrane-type ERV used in residential applications. Therefore, in this task, Gas Technology Institute (GTI) focused on a laboratory evaluation of the unbalanced flow (lowered exhaust airflow) performance of the RenewAire model EV 200, membrane-type ERV delivering 200 standard cubic feet per minute (SCFM) of supply air. The conducted tests show significant variation in ERV effectiveness at different levels of unbalanced air flows. Keeping supply airflow constant and lowering exhaust airflow increases effectiveness of both latent and sensible heat exchange. However, the increased effectiveness is accompanied by reduced capacity for load removal from the supply air, resulting in increased load to the conditioned space. Under decreasing exhaust airflow conditions, sensible load effectiveness exceeded a value of 1 at two sets of testing conditions. This was a result of the temperature rise of the supply air passing through the ERV augmented by the effect of motor heat gain, cross leakage heat gain, and casing heat gain. Consequently, measured sensible effectiveness must be qualified as the so-called Apparent Sensible Effectiveness of the ERV unit (the term used in the Canadian Standards Association C439 standard for testing ERVs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Software development infrastructure for the HYBRID modeling and simulation project

One of the goals of the HYBRID modeling and simulation project is to assess the economic viability of hybrid systems in a market that contains renewable energy sources like wind. The idea is that it is possible for the nuclear plant to sell non-electric energy cushions, which absorb (at least partially) the volatility introduced by the renewable energy sources. This system is currently modeled in the Modelica programming language. To assess the economics of the system, an optimization procedure is trying to find the minimal cost of electricity production. The RAVEN code is used as a driver for the whole problem. It is assumed that at this stage, the HYBRID modeling and simulation framework can be classified as non-safety “research and development” software. The associated quality level is Quality Level 3 software. This imposes low requirements on quality control, testing and documentation. The quality level could change as the application development continues.Despite the low quality requirement level, a workflow for the HYBRID developers has been defined that include a coding standard and some documentation and testing requirements. The repository performs automated unit testing of contributed models. The automated testing is achieved via an open-source python script called BuildingsP from Lawrence Berkeley National Lab. BuildingsPy runs Modelica simulation tests using Dymola in an automated manner and generates and runs unit tests from Modelica scripts written by developers. In order to assure effective communication between the different national laboratories a biweekly videoconference has been set-up, where developers can report their progress and issues. In addition, periodic face-face meetings are organized intended to discuss high-level strategy decisions with management. A second means of communication is the developer email list. This is a list to which everybody can send emails that will be received by the collective of the developers and managers involved in the project. Thirdly, to exchange documents quickly, a SharePoint directory has been set-up. SharePoint allows teams and organizations to intelligently share, and collaborate on content from anywhere.

97 MATHEMATICS AND COMPUTING↗

Deep in Data: Empirical Data Based Software Accuracy Testing Using the Building America Field Data Repository

This paper describes progress toward developing a usable, standardized, empirical data-based software accuracy test suite using home energy consumption and building description data. Empirical data collected from around the United States have been translated into a uniform Home Performance Extensible Markup Language format that may enable software developers to create translators to their input schemes for efficient access to the data. This could allow for modeling many homes expediently, and thus implementing software accuracy test cases by applying the translated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations

Purpose: The dosimetric accuracy of the recently released Acuros XB advanced dose calculation algorithm (Varian Medical Systems, Palo Alto, CA) is investigated for single radiation fields incident on homogeneous and heterogeneous geometries, and a comparison is made to the analytical anisotropic algorithm (AAA). Methods: Ion chamber measurements for the 6 and 18 MV beams within a range of field sizes (from 4.0x4.0 to 30.0x30.0 cm{sup 2}) are used to validate Acuros XB dose calculations within a unit density phantom. The dosimetric accuracy of Acuros XB in the presence of lung, low-density lung, air, and bone is determined using BEAMnrc/DOSXYZnrc calculations as a benchmark. Calculations using the AAA are included for reference to a current superposition/convolution standard. Results: Basic open field tests in a homogeneous phantom reveal an Acuros XB agreement with measurement to within {+-}1.9% in the inner field region for all field sizes and energies. Calculations on a heterogeneous interface phantom were found to agree with Monte Carlo calculations to within {+-}2.0%({sigma}{sub MC}=0.8%) in lung ({rho}=0.24 g cm{sup -3}) and within {+-}2.9%({sigma}{sub MC}=0.8%) in low-density lung ({rho}=0.1 g cm{sup -3}). In comparison, differences of up to 10.2% and 17.5% in lung and low-density lung were observed in the equivalent AAA calculations. Acuros XB dose calculations performed on a phantom containing an air cavity ({rho}=0.001 g cm{sup -3}) were found to be within the range of {+-}1.5% to {+-}4.5% of the BEAMnrc/DOSXYZnrc calculated benchmark ({sigma}{sub MC}=0.8%) in the tissue above and below the air cavity. A comparison of Acuros XB dose calculations performed on a lung CT dataset with a BEAMnrc/DOSXYZnrc benchmark shows agreement within {+-}2%/2mm and indicates that the remaining differences are primarily a result of differences in physical material assignments within a CT dataset. Conclusions: By considering the fundamental particle interactions in matter based on theoretical interaction cross sections, the Acuros XB algorithm is capable of modeling radiotherapy dose deposition with accuracy only previously achievable with Monte Carlo techniques.

60 APPLIED LIFE SCIENCES↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long Term Creep Behavior of a CoCrFeNiMn High Entropy Alloy

The potential of high entropy alloys (HEAs) to meet or exceed austenitic stainless-steel performance with the additional benefit of improved hot corrosion/oxidation resistance makes FCC HEAs attractive for use in energy applications. While shorter term creep tests have been reported in the literature on HEAs, not all methodologies utilize repeatable techniques. This manuscript reports on over 23,500 accumulated hours of tensile creep testing with adherence to ASTM standards on a melt solidified ingot of CoCrFeNiMn HEA converted to wrought plate using conventional thermo-mechanical processing techniques. The typical standard creep analyses are reported, i.e., Larson-Miller parameter, Monkman-Grant relationship, activation energy for creep, and creep stress exponents were calculated and compared to previously reported short-term creep tests. Additionally, characteristics of creep fracture and microstructural evolution are reported with cursory dislocation mechanisms investigated.

Rozman, Kyle A.↗

Improving energy performance metrics to maximize the benefits of disruptive technologies

Advances in appliance and equipment systems' technologies also cause changes in their technical characteristics that can affect energy consumption and associated greenhouse gas emissions. Energy performance evaluation methods that use testing and metrics can evolve to account for energy consumption contributed from new technological characteristics. However, there is no systematic effort to enable the advancement of test procedures and performance metrics to maximize the energy, climate, and financial benefits of disruptive technologies. Therefore, it is important for countries to regularly update their energy-efficiency policy programs, such as standards and labels, by improving test procedures and metrics to reflect the innovation in emerging technologies as well as to mitigate the risk of deploying obsolete technology. This paper shows how energy performance metrics have been improving in selected appliances and equipment and provides insights to design a systematic effort to improve metrics and test procedures at the speed of ongoing changes in technologies and markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗