Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Validation and application of a multiphase CFD model for hydrodynamics, temperature field and RTD simulation in a pilot-scale biomass pyrolysis vapor phase upgrading reactor

Accurate prediction of transport phenomena is critical for VPU reactor design, optimization, and scale-up. The current study focused on the validation and application of a multiphase CFD model within an open-source code MFiX for hydrodynamics, temperature field, and residence time distribution (RTD) simulation in a non-reacting circulating fluidized bed riser for biomass pyrolysis vapor phase upgrading (VPU). First, an Eulerian-Eulerian approach three-dimensional CFD model was employed to simulate the pilot-scale VPU riser on the supercomputer Joule. Excellent quantitative agreement between experimental and simulated results was achieved for pressure drops and temperature field in a range of operating conditions. Then the validated multiphase CFD model was applied to predict gas and solid residence time distributions (RTDs) since prediction and analysis of RTD is an important tool to study the complex multiphase flow behavior and mixing inside chemical reactors. The predictions show that solid mean residence time is 3.5 times the gas residence time; the solid RTD is more sensitive to the process gas flow rate than the solids circulation rate.

09 BIOMASS FUELS↗

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Testing the validity of a mechanism describing the oxidation of binary n-heptane/toluene mixtures at engine operating conditions

The purpose of this work is to evaluate the influence of the n-heptane/toluene ratio on the reactivity of binary toluene reference fuels (TRFs), through a combined experimental and numerical work. Novel experimental ignition delay time (IDT) data of three binary TRFs of varying n-heptane/toluene ratios have been obtained in a high-pressure shock tube and in a rapid compression machine at conditions relevant to novel engine operation. Measurements have been performed at two pressures (10 and 30 bar), and at three fuel/air equivalence ratios (0.5, 1.0 and 2.0) for TRF mixtures of 50%, 75% and 90% by volume toluene concentration, over the temperature range of 650–1450 K. It was found that, increasing the n-heptane content, led to an increase in reactivity and shorter measured IDTs. Reduced sensitivity to the equivalence ratio was observed at high temperatures, especially for high toluene content mixtures. A well validated detailed kinetic mechanism for TRF oxidation was utilized to provide further insight into the experimental evidence. The mechanism, which has recently been updated, was also assessed in terms of its validity, contributing thus to its continuous development. Reaction path analysis was performed to delineate critical aspects of toluene oxidation under the considered conditions. Moreoever, sensitivity analysis highlighted the interactions between the chemistry of the two TRF components, revealing toluene's character as a reactivity inhibitor mainly through the consumption of ÓH radicals.

30 DIRECT ENERGY CONVERSION↗

Validation of process simulation workflow for thermosetting prepreg platelet molding compounds

Continuous carbon fiber prepreg slit and cut into rectangular platelets has proven to be a useful material for net shape molding of semi-structural and structural components in the aerospace and automotive industries. Furthermore, to assist the designer in use of these prepreg platelet molding compounds, sometimes called carbon fiber sheet molding compounds, simulation tools are required that can predict the as-manufactured fiber orientation state which has a significant impact on the resulting performance. Herein, an analysis workflow for design-enabling predictions is demonstrated for a double dome geometry with two different initial charge configurations. Here, the workflow is validated through comparison with experimental short shots, orientation state, and stiffness trends. Significantly, to complete the validation, a method is proposed for determining the confidence bounds on measured orientation state enhancing the results of optical microscopy which can only produce a small sample of platelet orientations.

36 MATERIALS SCIENCE↗

Verification and validation of residual stresses in composite structures

Process-induced residual stresses occur in composite structures composed of dissimilar materials. As these residual stresses could result in fracture, their consideration when designing composite parts is necessary. However, the experimental determination of residual stresses in prototype parts can be time and cost prohibitive. Alternatively, it is possible for computational tools to predict potential residual stresses. Therefore, the objectives of the presented work are to demonstrate an efficient method for simulating residual stresses in composite parts, as well as the potential value of statistical methods during analyses for which material properties are unknown. Specifically, a simplified residual stress modeling approach is implemented within Sandia National Laboratories’ SIERRA/SolidMechanics code. Concurrent with the model development, bi-material composite structures are designed and manufactured to exhibit significant residual stresses. Then, the presented modeling approach is rigorously verified and validated through simulations of the bi-material composite structures’ manufacturing processes, including a mesh convergence study, sensitivity analysis, and uncertainty quantification. The simulations’ final results show adequate agreement with the experimental measurements, indicating the validity of a simple modeling approach, as well as a necessity for the inclusion of material parameter uncertainty in the final residual stress predictions.

42 ENGINEERING↗

Validating corrosion models: Influence of physical properties

In chloride containing environments, two metals in physical contact can undergo galvanic corrosion limiting the lifetime of components. Being able to accurately predict galvanic corrosion damage distributions over time has not been widely presented in literature. Therefore, Finite Element Method (FEM) corrosion models were experimentally validated for two galvanic couples as a function of governing equations, environment, anode material, anode:cathode ratio, and time. Carbon steel/stainless steel (CS/SS) and zinc/stainless steel (Zn/SS) galvanic couples were exposed to NaCl solutions at room temperatures for up to 14 days. For the galvanic couples and environments, the Laplace equation with variable conductivity and reactions was sufficient to model the experimental corrosion damage. Increasing the chloride concentration for the CS/SS galvanic couple, regardless of the anode:cathode ratio, decreased the observed and modeled corrosion damage. Decreasing the anode:cathode ratio (i.e., increasing the cathode length), increased the experimentally observed and modeled corrosion damage. For small anode:cathode ratios, the governing equations deviate over long time periods with the Nernst-Plank equation being conservative. For the Zn/SS galvanic couple, the cathode length controls the dominant cathodic reduction reaction. For small cathode lengths, the hydrogen evolution reaction is dominant. For larger cathode lengths, the oxygen reduction reaction is dominant. The results are discussed with regard to the influence of solution chemistry, ohmic drop, and governing reactions. Overall, validated FEM models were presented, and the resultant models, physics, and mechanisms can be applied to other corrosion scenarios with confidence.

Carbon steel↗

Numerical and experimental validation for the thermal transmittance of windows with cellular shades

Some highly energy efficient window attachment products are available today, but more rapid market adoption would be facilitated by fair performance metrics. It is important to have validated simulation tools to provide a basis for this analysis. This paper outlines a review and validation of the ISO 15099 center-of-glass zero-solar-load heat transfer correlations for windows with cellular shades. Thermal transmittance was measured experimentally, simulated using computational fluid dynamics (CFD) analysis, and simulated utilizing correlations from ISO 15099 as implemented in Berkeley Lab WINDOW and THERM software. CFD analysis showed ISO 15099 underestimates heat flux of rectangular cavities by up to 60% when aspect ratio (AR) = 1 and overestimates heat flux up to 20% when AR = 0.5. CFD analysis also showed that wave-type surfaces of cellular shades have less than 2% impact on heat flux through the cavities and less than 5% for natural convection of room-side surface. WINDOW was shown to accurately represent heat flux of the measured configurations to a mean relative error of 0.5% and standard deviation of 3.8%. Finally, several shade parameters showed significant influence on correlation accuracy, including distance between shade and glass, inconsistency in cell stretch, size of perimeter gaps, and the mounting hardware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Measurement-driven, model-based estimation of residual stress and its effects on fatigue crack growth. Part 1: Validation of an eigenstrain model

The objective of this paper is to validate a measurement-driven, model-based approach to estimate residual stress (RS) in samples machined from quenched aluminum stock. Model input is derived from measurement of RS in the parent stock. Validation is performed for prismatic T-sections removed from bars at different locations. We find RS predicted agrees with RS measured, by contour and neutron diffraction methods, with root-mean-square model-measurement difference of 22 MPa. Follow-on work (in Part 2) applies the RS estimation to samples representative of aircraft structures and examines the effects of RS on fatigue crack growth in the RS-bearing samples.

36 MATERIALS SCIENCE↗

Multi-scale dynamic modeling and validation of radial flow fixed bed contactors for post-combustion CO 2 capture using bench scale and pilot plant data

Here, in this work, a multi-scale model of a radial flow fixed bed contactor packed with a carbon sorbent is developed and validated with laboratory-scale and pilot plant scale dynamic data. For the lab scale system, the model results were compared with low, medium and high gas and sweep flowrates, yielding root mean square error (RMSE) of 0.80, 0.63, 0.96 CO 2 mol%, respectively, for the outlet CO 2 concentration profile considering the entire A-D cycle. For the bed outer temperature profile, maximum RMSE was found to be 5.5 °C considering all flowrates and entire A-D cycles. An experimental campaign was developed and applied to a pilot plant at Technology Center Mongstad (TCM), Norway. Approaches were developed for pre-processing of data including consideration of the effect of gas mixing, measurement delay, and determination of cyclic steady-state conditions. Considering profiles during A-D cycles for all test runs, it was found that the maximum RMSE for pressure drop, temperature for the outer section of the bed, temperature for the middle section of the bed, and outlet CO 2 concentration profile remained less than 1.5 mbar, 3.5 °C, 2.8 °C, and 1.3 CO 2 mol%, respectively. The validated model was used to perform sensitivity studies on several key design operating variables for the adsorption-desorption cycle. It was found that the flow rate and concentration of flue gas have dominant nonlinear effects on the breakthrough time while the desorption time was strongly affected by the sweep gas flowrate for the specific sorbent being evaluated in this study.

20 FOSSIL-FUELED POWER PLANTS↗

Development, validation, and verification of multi-pass thermo-mechanical welding simulations using the open-source MOOSE framework: NeT TG4 benchmark weldment

This study develops and validates a sequentially coupled thermo-mechanical welding simulation for the three-pass 316L stainless steel NeT TG4 benchmark weldment using the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE) and the Nuclear Engineering Material model Library (NEML). A diffused ellipsoidal heat source was calibrated against thermocouple data and weld macrographs to accurately model the fusion zone geometry and transient thermal fields. Material hardening is represented using the Lemaitre-Chaboche mixed isotropic-kinematic hardening model, while four annealing models - no annealing, single-stage at 1050 °C and 1300 °C, and two-stage at 800 °C/1300 °C - were implemented to assess the impact of annealing models on the accuracy of the predicted welding-induced plasticity, distortions, and residual stresses. The predictions were validated against experimental measurements and benchmarked against results from commercial software, demonstrating that thermo-mechanical MOOSE welding simulations achieve comparable accuracy with enhanced computational efficiency. This work highlights the potential of using open-source finite element frameworks like MOOSE for advanced manufacturing simulations.

Ji, Wendy [Australian Nuclear Science and Technolo↗

Prospective Study Validating Inter- and Intraobserver Variability of Tissue Compliance Meter in Breast Tissue of Healthy Volunteers: Potential Implications for Patients With Radiation-Induced Fibrosis of the Breast

Purpose: Accurate detection of radiation-induced fibrosis (RIF) is crucial in management of breast cancer survivors. Tissue compliance meter (TCM) has been validated in musculature. We validate TCM in healthy breast tissue with respect to interobserver and intraobserver variability before applying it in RIF. Methods and Materials: Three medical professionals obtained three consecutive TCM measurements in each of the four quadrants of the right and left breasts of 40 women with no breast disease or surgical intervention. The intraclass correlation coefficient (ICC) assessed interobserver variability. The paired t test and Pearson correlation coefficient (r) were used to assess intraobserver variability within each rater. Results: The median age was 45 years (range, 24-68 years). The median bra size was 35C (range, 32A-40DD). Of the participants, 27 were white (67%), 4 black (10%), 5 Asian (13%), and 4 Hispanic (10%). ICCs indicated excellent interrater reliability (low interobserver variability) among the three raters, by breast and quadrant (all ICC {>=}0.99). The paired t test and Pearson correlation coefficient both indicated low intraobserver variability within each rater (right vs. left breast), stratified by quadrant (all r{>=} 0.94, p < 0.0001). Conclusions: The interobserver and intraobserver variability is small using TCM in healthy mammary tissue. We are now embarking on a prospective study using TCM in women with breast cancer at risk of developing RIF that may guide early detection, timely therapeutic intervention, and assessment of success of therapy for RIF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Normal Tissue Complication Probability Predictions in Individual Patient: Late Rectal Toxicity

Purpose: To perform validation of risk predictions for late rectal toxicity (LRT) in prostate cancer obtained using a new approach to synthesize published normal tissue complication data. Methods and Materials: A published study survey was performed to identify the dose-response relationships for LRT derived from nonoverlapping patient populations. To avoid mixing models based on different symptoms, the emphasis was placed on rectal bleeding. The selected models were used to compute the risk estimates of grade 2+ and grade 3+ LRT for an independent validation cohort composed of 269 prostate cancer patients with known toxicity outcomes. Risk estimates from single studies were combined to produce consolidated risk estimates. An agreement between the actuarial toxicity incidence 3 years after radiation therapy completion and single-study or consolidated risk estimates was evaluated using the concordance correlation coefficient. Goodness of fit for the consolidated risk estimates was assessed using the Hosmer-Lemeshow test. Results: A total of 16 studies of grade 2+ and 5 studies of grade 3+ LRT met the inclusion criteria. The consolidated risk estimates of grade 2+ and 3+ LRT were constructed using 3 studies each. For grade 2+ LRT, the concordance correlation coefficient for the consolidated risk estimates was 0.537 compared with 0.431 for the best-fit single study. For grade 3+ LRT, the concordance correlation coefficient for the consolidated risk estimates was 0.477 compared with 0.448 for the best-fit single study. No evidence was found for a lack of fit for the consolidated risk estimates using the Hosmer-Lemeshow test (P=.531 and P=.397 for grade 2+ and 3+ LRT, respectively). Conclusions: In a large cohort of prostate cancer patients, selected sets of consolidated risk estimates were found to be more accurate predictors of LRT than risk estimates derived from any single study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validated Competing Event Model for the Stage I-II Endometrial Cancer Population

Purpose/Objectives(s): Early-stage endometrial cancer patients are at higher risk of noncancer mortality than of cancer mortality. Competing event models incorporating comorbidity could help identify women most likely to benefit from treatment intensification. Methods and Materials: 67,397 women with stage I-II endometrioid adenocarcinoma after total hysterectomy diagnosed from 1988 to 2009 were identified in Surveillance, Epidemiology, and End Results (SEER) and linked SEER-Medicare databases. Using demographic and clinical information, including comorbidity, we sought to develop and validate a risk score to predict the incidence of competing mortality. Results: In the validation cohort, increasing competing mortality risk score was associated with increased risk of noncancer mortality (subdistribution hazard ratio [SDHR], 1.92; 95% confidence interval [CI], 1.60-2.30) and decreased risk of endometrial cancer mortality (SDHR, 0.61; 95% CI, 0.55-0.78). Controlling for other variables, Charlson Comorbidity Index (CCI) = 1 (SDHR, 1.62; 95% CI, 1.45-1.82) and CCI >1 (SDHR, 3.31; 95% CI, 2.74-4.01) were associated with increased risk of noncancer mortality. The 10-year cumulative incidences of competing mortality within low-, medium-, and high-risk strata were 27.3% (95% CI, 25.2%-29.4%), 34.6% (95% CI, 32.5%-36.7%), and 50.3% (95% CI, 48.2%-52.6%), respectively. With increasing competing mortality risk score, we observed a significant decline in omega (ω), indicating a diminishing likelihood of benefit from treatment intensification. Conclusion: Comorbidity and other factors influence the risk of competing mortality among patients with early-stage endometrial cancer. Competing event models could improve our ability to identify patients likely to benefit from treatment intensification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-Rhabdomyosarcoma Soft Tissue Sarcomas in Children: A Surveillance, Epidemiology, and End Results Analysis Validating COG Risk Stratifications

Purpose: Non-rhabdomyosarcoma soft tissue sarcomas (NRSTS) are a heterogeneous group of sarcomas that encompass over 35 histologies. With an incidence of ∼500 cases per year in the United States in those <20 years of age, NRSTS are rare and therefore difficult to study in pediatric populations. We used the large Surveillance, Epidemiology, and End Results (SEER) database to validate the prognostic ability of the Children's Oncology Group (COG) risk classification system and to define patient, tumor, and treatment characteristics. Methods and Materials: From SEER data from 1988 to 2007, we identified patients ≤18 years of age with NRSTS. Data for age, sex, year of diagnosis, race, registry, histology, grade, primary size, primary site, stage, radiation therapy, and survival outcomes were analyzed. Patients with nonmetastatic grossly resected low-grade tumors of any size or high-grade tumors ≤5 cm were considered low risk. Cases of nonmetastatic tumors that were high grade, >5 cm, or unresectable were considered intermediate risk. Patients with nodal or distant metastases were considered high risk. Results: A total of 941 patients met the review criteria. On univariate analysis, black race, malignant peripheral nerve sheath (MPNST) histology, tumors >5 cm, nonextremity primary, lymph node involvement, radiation therapy, and higher risk group were associated with significantly worse overall survival (OS) and cancer-specific survival (CSS). On multivariate analysis, MPNST histology, chemotherapy-resistant histology, and higher risk group were significantly poor prognostic factors for OS and CSS. Compared to low-risk patients, intermediate patients showed poorer OS (hazard ratio [HR]: 6.08, 95% confidence interval [CI]: 3.53-10.47, P<.001) and CSS (HR: 6.27; 95% CI: 3.44-11.43, P<.001), and high-risk patients had the worst OS (HR: 13.35, 95% CI: 8.18-21.76, P<.001) and CSS (HR: 14.65, 95% CI: 8.49-25.28, P<.001). Conclusions: The current COG risk group stratification for children with NRSTS has been validated with a large number of children in the SEER database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Validated Prediction Model for Overall Survival From Stage III Non-Small Cell Lung Cancer: Toward Survival Prediction for Individual Patients

Purpose: Although patients with stage III non-small cell lung cancer (NSCLC) are homogeneous according to the TNM staging system, they form a heterogeneous group, which is reflected in the survival outcome. The increasing amount of information for an individual patient and the growing number of treatment options facilitate personalized treatment, but they also complicate treatment decision making. Decision support systems (DSS), which provide individualized prognostic information, can overcome this but are currently lacking. A DSS for stage III NSCLC requires the development and integration of multiple models. The current study takes the first step in this process by developing and validating a model that can provide physicians with a survival probability for an individual NSCLC patient. Methods and Materials: Data from 548 patients with stage III NSCLC were available to enable the development of a prediction model, using stratified Cox regression. Variables were selected by using a bootstrap procedure. Performance of the model was expressed as the c statistic, assessed internally and on 2 external data sets (n=174 and n=130). Results: The final multivariate model, stratified for treatment, consisted of age, gender, World Health Organization performance status, overall treatment time, equivalent radiation dose, number of positive lymph node stations, and gross tumor volume. The bootstrapped c statistic was 0.62. The model could identify risk groups in external data sets. Nomograms were constructed to predict an individual patient's survival probability ( (www.predictcancer.org)). The data set can be downloaded at (https://www.cancerdata.org/10.1016/j.ijrobp.2015.02.048). Conclusions: The prediction model for overall survival of patients with stage III NSCLC highlights the importance of combining patient, clinical, and treatment variables. Nomograms were developed and validated. This tool could be used as a first building block for a decision support system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography Internal Motion Tracking Should Be Used to Validate 4-Dimensional Computed Tomography for Abdominal Radiation Therapy Patients

Purpose: To demonstrate that fiducial tracking during pretreatment Cone-Beam CT (CBCT) can accurately measure tumor motion and that this method should be used to validate 4-dimensional CT (4DCT) margins before each treatment fraction. Methods and Materials: For 31 patients with abdominal tumors and implanted fiducial markers, tumor motion was measured daily with CBCT and fluoroscopy for 202 treatment fractions. Fiducial tracking and maximum-likelihood algorithms extracted 3-dimensional fiducial trajectories from CBCT projections. The daily internal margin (IM) (ie, range of fiducial motion) was calculated for CBCT and fluoroscopy as the 5th-95th percentiles of displacement in each cardinal direction. The planning IM from simulation 4DCT (IM{sub 4DCT}) was considered adequate when within ±1.2 mm (anterior–posterior, left–right) and ±3 mm (superior–inferior) of the daily measured IM. We validated CBCT fiducial tracking as an accurate predictive measure of intrafraction motion by comparing the daily measured IM{sub CBCT} with the daily IM measured by pretreatment fluoroscopy (IM{sub pre-fluoro}); these were compared with pre- and posttreatment fluoroscopy (IM{sub fluoro}) to identify those patients who could benefit from imaging during treatment. Results: Four-dimensional CT could not accurately predict intrafractional tumor motion for ≥80% of fractions in 94% (IM{sub CBCT}), 97% (IM{sub pre-fluoro}), and 100% (IM{sub fluoro}) of patients. The IM{sub CBCT} was significantly closer to IM{sub pre-fluoro} than IM{sub 4DCT} (P<.01). For patients with median treatment time t < 7.5 minutes, IM{sub CBCT} was in agreement with IM{sub fluoro} for 93% of fractions (superior–inferior), compared with 63% for the t > 7.5 minutes group, demonstrating the need for patient-specific intratreatment imaging. Conclusions: Tumor motion determined from 4DCT simulation does not accurately predict the daily motion observed on CBCT or fluoroscopy. Cone-beam CT could replace fluoroscopy for pretreatment verification of simulation IM{sub 4DCT}, reducing patient setup time and imaging dose. Patients with treatment time t > 7.5 minutes could benefit from the addition of intratreatment imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of radiative transfer computation with Monte Carlo method for ultra-relativistic background flow

We developed a three-dimensional radiative transfer code for an ultra-relativistic background flow-field by using the Monte Carlo (MC) method in the context of gamma-ray burst (GRB) emission. For obtaining reliable simulation results in the coupled computation of MC radiation transport with relativistic hydrodynamics which can reproduce GRB emission, we validated radiative transfer computation in the ultra-relativistic regime and assessed the appropriate simulation conditions. The radiative transfer code was validated through two test calculations: (1) computing in different inertial frames and (2) computing in flow-fields with discontinuous and smeared shock fronts. The simulation results of the angular distribution and spectrum were compared among three different inertial frames and in good agreement with each other. If the time duration for updating the flow-field was sufficiently small to resolve a mean free path of a photon into ten steps, the results were thoroughly converged. The spectrum computed in the flow-field with a discontinuous shock front obeyed a power-law in frequency whose index was positive in the range from 1 to 10 MeV. The number of photons in the high-energy side decreased with the smeared shock front because the photons were less scattered immediately behind the shock wave due to the small electron number density. The large optical depth near the shock front was needed for obtaining high-energy photons through bulk Compton scattering. Even one-dimensional structure of the shock wave could affect the results of radiation transport computation. Although we examined the effect of the shock structure on the emitted spectrum with a large number of cells, it is hard to employ so many computational cells per dimension in multi-dimensional simulations. Therefore, a further investigation with a smaller number of cells is required for obtaining realistic high-energy photons with multi-dimensional computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗