Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Single-neutron states in {sup 101}Sn.

A search for {gamma}-ray transitions in {sup 101}Sn, which contains only one neutron outside the {sup 100}Sn core, was carried out a tthe Argonne Tandem-Linac Accelerator System. {sup 101}Sn nuclei were produced using the {sup 46}Ti({sup 58}Ni, 3n){sup 101}Sn reaction. In-beam {gamma} rays were detected in the Gammasphere Ge-detector array and were correlated with {sup 101}Sn {beta}-delayed protons using the Recoil-Decay Tagging method. A {gamma}-ray line at 172 keV was assigned to {sup 101}Sn and was interpreted as the transition between the single-neutron g{sub 7/2} and d{sub 5/2} states. The measured {nu}g{sub 7/2{sup -}}{nu}{sup d{sub 5/2}} energy splitting is compared with predictions of various mean-field potentials. It is also used to calculate multi-neutron configurations in light Sn isotopes. Prospects of using {beta}-delayed protons for tagging other exotic nuclei in the {sup 100}Sn region are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time multiplicity counter

A neutron multi-detector array feeds pulses in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel. The word is read at regular intervals, all bits simultaneously, to minimize latency. The electronics then pass the word to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Blocking Losses on an Optical Communications Link

Many photon-counting photo-detectors have the property that they become inoperative for some time after detection event. We say the detector is blocked during this time.Blocking produces losses when using the detector as a photon-counter to detect a communications signal. In this paper, we characterize blocking losses for single detectors and for arrays of detectors. For arrays, we discuss conditions under which the output may be approximated as a Poisson point process, and provide a simple approximation to the blocking loss. We show how to extend the analysis to arrays of non-uniformly illuminated arrays.

blocked detectors↗

Integrated Miniature Arrays of Optical Biomolecule Detectors

Integrated miniature planar arrays of optical sensors for detecting specific biochemicals in extremely small quantities have been proposed. An array of this type would have an area of about 1 cm2. Each element of the array would include an optical microresonator that would have a high value of the resonance quality factor (Q . 107). The surface of each microresonator would be derivatized to make it bind molecules of a species of interest, and such binding would introduce a measurable change in the optical properties of the microresonator. Because each microresonator could be derivatized for detection of a specific biochemical different from those of the other microresonators, it would be possible to detect multiple specific biochemicals by simultaneous or sequential interrogation of all the elements in the array. Moreover, the derivatization would make it unnecessary to prepare samples by chemical tagging. Such interrogation would be effected by means of a grid of row and column polymer-based optical waveguides that would be integral parts of a chip on which the array would be fabricated. The row and column polymer-based optical waveguides would intersect at the elements of the array (see figure). At each intersection, the row and column waveguides would be optically coupled to one of the microresonators. The polymer-based waveguides would be connected via optical fibers to external light sources and photodetectors. One set of waveguides and fibers (e.g., the row waveguides and fibers) would couple light from the sources to the resonators; the other set of waveguides and fibers (e.g., the column waveguides and fibers) would couple light from the microresonators to the photodetectors. Each microresonator could be addressed individually by row and column for measurement of its optical transmission. Optionally, the chip could be fabricated so that each microresonator would lie inside a microwell, into which a microscopic liquid sample could be dispensed.

Iltchenko, Vladimir↗

Generalized spatial filtering velocimetry and accelerometry for uniform and nonuniform objects

We present a technique to measure velocity, acceleration, and higher order derivatives of motion using periodic and nonperiodic spatial filters. The technique can be applied using a single detector or an array of detectors. In one configuration, the velocity distribution of an object such as a fluid can be measured by imaging the object onto an array of detectors. In another configuration, multiple projections of an object are used to reconstruct a cross-sectional velocity distribution using a tomography algorithm. The advantages and disadvantages of our technique applied to uniform and spatially varying motions are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital Electronics For The Versatile Array Of Neutron Detectors At Low Energies

A {chi}{sup 2} minimization algorithm has been developed to extract sub-sampling-time information from digitized waveforms, to be used to instrument the future Versatile Array of Neutron Detectors at Low energies. The algorithm performance has been characterized with a fast Arbitrary Function Generator, obtaining time resolution better than 1 ns for signals of amplitudes between 50 mV and 1V, with negligible walk in the whole range. The proof-of-principle measurement of the beta-delayed neutron emission from {sup 89}Br indicates a resolution of 1 ns can be achieved in realistic experimental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

Si-APD linear-array x-ray detector with 10-100 μm spatial and sub-nanosecond time resolution

We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for time-resolved X-ray scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100 × 200 μm{sup 2}) with a pixel pitch of 150 μm and a depletion depth of 10 μm. The multichannel scaler counted X-ray pulses over continuous 2046 time bins for every 0.5 ns and recorded a time spectrum at each pixel with a time resolution of 0.5 ns (FWHM) for 8.0 keV X-rays. Using the detector system, we were able to observe X-ray peaks clearly separated with 2 ns interval in the multibunch-mode operation of the Photon Factory ring. The small-angle X-ray scattering for polyvinylidene fluoride film was also observed with the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixing efficiency in heterodyne systems

How the spatial distributions of the signal and local oscillator fields affect the heterodyne signal to noise ratio is examined for both a single detector and an array of detectors. For an array, the distribution of gain among the intermediate frequency (i.f.) amplifiers is included. The emphasis is on understanding why the distributions are important and what is the key to maximizing the signal to noise ratio in any system. It is shown that for a single detector, the highest signal to noise ratio is obtained with a local oscillator (LO) distribution the same as that of the signal. For an array, the product of the i.f. gain times the LO field at each detector has the same distribution as that of the signal field.

Fink, D.↗

Improved performance of HgCdTe infrared detector focal plane arrays by modulating light field based on photonic crystal structure

An HgCdTe long-wavelength infrared focal plane array photodetector is proposed by modulating light distributions based on the photonic crystal. It is shown that a promising prospect of improving performance is better light harvest and dark current limitation. To optimize the photon field distributions of the HgCdTe-based photonic crystal structure, a numerical method is built by combining the finite-element modeling and the finite-difference time-domain simulation. The optical and electrical characteristics of designed HgCdTe mid-wavelength and long-wavelength photon-trapping infrared detector focal plane arrays are obtained numerically. The results indicate that the photon crystal structure, which is entirely compatible with the large infrared focal plane arrays, can significantly reduce the dark current without degrading the quantum efficiency compared to the regular mesa or planar structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a Thin-Wndow Silicon Drift Detector X-Ray Fluorescence Spectrometer

Several sets of hexagonal Silicon Drift Detector (SDD) arrays were produced by Brookhaven National Laboratory (BNL) and by the commercial vendor, KETEK. These detector arrays were tested at BNL. Each array consists of 14 independent SDD detectors (pixels) and two additional test pixels located at two corners of the array. The side of the detector upon which the X-ray radiation is incident (window side) has a thin junction covering the entire active area. The opposite side (device side) contains a drift-field electrode structure in the form of a hexagonal spiral and an electron collecting anode. There are four guard rings surrounding the 14-pixel array area on each side of the detector. Within each array, seven pixels have aluminum field plates - interrupted spirals that stabilize the electric potential under the Si-SiO{sub 2} interface, while the other seven do not. Three bias voltages are applied to control the drift field in the silicon volume; one is applied to a rectifying contact surrounding the central anode (one for each pixel), one is applied to the detector entrance window (common to the full array), and a third bias is applied to a contact on the outer portion of the spiral, common to all pixels in the array. Some arrays were recently tested in NSLS beam line U3C at BNL. For this work, we installed the complete assemblies in the vacuum and cooled them to -27degC. During this beam run, we collected spectra for energies ranging between 350 and 900 eV in several pixels, some with field plates and others without. The detailed testing results of several arrays are reported here.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid Compton camera/coded aperture imaging system

A system in one embodiment includes an array of radiation detectors; and an array of imagers positioned behind the array of detectors relative to an expected trajectory of incoming radiation. A method in another embodiment includes detecting incoming radiation with an array of radiation detectors; detecting the incoming radiation with an array of imagers positioned behind the array of detectors relative to a trajectory of the incoming radiation; and performing at least one of Compton imaging using at least the imagers and coded aperture imaging using at least the imagers. A method in yet another embodiment includes detecting incoming radiation with an array of imagers positioned behind an array of detectors relative to a trajectory of the incoming radiation; and performing Compton imaging using at least the imagers.

47 OTHER INSTRUMENTATION↗

Low background signal readout electronics for the MAJORANA DEMONSTRATOR

The MAJORANA Collaboration will seek neutrinoless double beta decay (0νββ) in {sup 76}Ge using isotopically enriched p-type point contact (PPC) high purity Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require background levels below 1 count/ROI-tonne-year in the 4 keV region of interest (ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe detector array, is being constructed with a background goal of < 3 count/ROI-tonne-year, which is expected to scale down to < 1 count/ROI-tonne-year for a tonne-scale experiment. The signal readout electronics, which must be placed in close proximity to the detectors, present a challenge toward reaching this background goal. This talk will discuss the materials and design used to construct signal readout electronics with low enough backgrounds for the MAJORANA DEMONSTRATOR.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

Timothy, J. Gethyn↗

Development of a large array of Silicon Drift Detectors for high-rate synchrotron fluorescence spectroscopy

An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.

47 OTHER INSTRUMENTATION↗