Search NASA⌕ Search

SEARCH · Search NASA

Results for “building technologies program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The Development of Open Water-lubricated Polycrystalline Diamond (PCD) Thrust Bearings for Use in Marine Hydrokinetic (MHK) Energy Machines

Polycrstalline diamond (PCD) bearings were designed, fabricated and tested for marine-hydro-kinetic (MHK) application. Bearing efficiency and life were evaluated using the US Synthetic bearing test facility. Three iterations of design, build and test were conducted to arrive at the best bearing design. In addition life testing that simulated the starting and stopping and the loading of real MHK applications were performed. Results showed polycrystalline diamond bearings are well suited for MHK applications and that diamond bearing technology is TRL4 ready. Based on life tests results bearing life is estimated to be at least 11.5 years. A calculation method for evaluating the performance of diamond bearings of round geometry was also investigated and developed. Finally, as part of this effort test bearings were supplied free of charge to the University of Alaska for further evaluation. The University of Alaska test program will subject the diamond bearings to sediment laden lubricating fluid.

16 TIDAL AND WAVE POWER↗

The State of Demand Flexibility Programs and Rates

This report provides foundational data on programs and rates that promote demand flexibility in residential and commercial buildings in the United States. Leveraging a dataset of 148 programs and 94 rates collected through a review of utility websites, published electricity tariffs, and a database of demand-side programs, we describe the structure of demand flexibility events and the types and levels of incentives offered. For the two most common program types in our dataset—Wi-Fi thermostat and battery storage programs—we provide additional details on program designs. We also report data on program outcomes, including enrollment and participation, energy and demand savings, and costs. Furthermore, we describe the structure of dynamic rate events, report prices for critical peak pricing and variable peak pricing rates, and describe features of technology rates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation for Removal of Building 01-202681 in the Main Storage Yard of the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

The Main Storage Yard was originally recorded as SHPO Resource No. S2772 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and as contributing to the significance of the potential Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed). The Main Storage Yard retains all seven aspects of integrity. The location, design, materials, workmanship, feeling, and association have not changed since the original construction. Since the purpose of the yard is to maintain storage equipment that is actively being used, the design and feeling will change each time equipment is moved. Such actions reinforce the integrity of design and feeling. Buildings 01-101 and 01-102 were removed (Collins and Menocal 2020), but the other buildings and storage yard remain. Therefore, the setting has been changed, but not to the degree that the Main Storage Yard no longer conveys its significance (see Figures 4 and 5 for comparison). The Main Storage Yard was designed to facilitate the relocation of the Area 3 Subdock to Area 1 in 1985. The design for the overall Subdock provided a centralized cluster of buildings surrounded by two large storage yards. While the North Storage Yard largely serves as overflow storage, the Main Storage Yard holds the majority of drill rigs and drilling equipment needed to support big hole drilling. The Main Storage Yard and its contents were essential elements of the nuclear testing drilling program on the NNSS thus making it eligible for the NRHP under Criterion A for its contribution to broad patterns of history by storing specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is an engineered landscape that now serves as an open-air repository of drilling technology and nuclear testing. In addition to its individual significance, the Main Storage Yard also contributes to the significance of the Area 1 Subdock Historic District as it showcases a variety of big-hole drilling equipment, support facilities, and warehouses that were specially designed for nuclear testing at the NNSS. Despite the demolition of two contributing elements to date, the district still contains numerous examples of other facilities with the purpose of supporting big-hole drilling; therefore, the district still remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

Wind Lidar Edge Technique Shuttle Demonstration Mission: Anemos

A NASA mission is planned to demonstrate the technology for a wind lidar. This will implement the direct detection edge technique. The Anemos instrument will fly on the Space Transportation System (STS), or shuttle, aboard a Hitchhiker bridge. The instrument is being managed by the Goddard Space Flight Center as an in-house build, with science leadership from the GSFC Laboratory for Atmospheres, Mesoscale Atmospheric Processes Branch. During a roughly ten-day mission, the instrument will self calibrate and adjust for launch induced mis-alignments, and perform a campaign of measurements of tropospheric winds. The mission is planned for early 2001. The instrument is being developed under the auspices of NASA's New Millennium Program, in parallel with a comparable mission being managed by the Marshall Space Flight Center. That mission, called SPARCLE, will implement the coherent technique. NASA plans to fly the two missions together on the same shuttle flight, to allow synergy of wind measurements and a direct comparison of performance.

Leete, Stephen J.↗

Solar Sail Propulsion Technology at NASA

NASA's In-Space Propulsion Technology Program developed the first generation of solar sail propulsion systems sufficient to accomplish inner solar system science and exploration missions. These first generation solar sails, when operational, will range in size from 40 meters to well over 100 meters in diameter and have an area density of less than 13 grams per square meter. A rigorous, multi-year technology development effort culminated in 2005 with the testing of two different 20-m solar sail systems under thermal vacuum conditions. This effort provided a number of significant insights into the optimal design and expected performance of solar sails as well as an understanding of the methods and costs of building and using them. In addition, solar sail orbital analysis tools for mission design were developed and tested. Laboratory simulations of the effects of long-term space radiation exposure were also conducted on two candidate solar sail materials. Detailed radiation and charging environments were defined for mission trajectories outside the protection of the earth's magnetosphere, in the solar wind environment. These were used in other analytical tools to prove the adequacy of sail design features for accommodating the harsh space environment. The presentation will describe the status of solar sail propulsion within NASA, near-term solar sail mission applications, and near-term plans for further development.

Johnson, Charles Les↗

REopt: Enabling Renewable Energy, Storage, and Combined Heat and Power

Deployment of distributed energy resources including combined heat and power (CHP), photovoltaics (PV), and battery storage is growing as building and campus owners seek to reduce energy costs and increase resilience to grid outages. While deployment of a single technology is widespread, integrated systems of multiple technologies are also becoming more common to provide maximum economic and resilience benefits. To accelerate deployment, decision makers require tools to evaluate the technical and economic feasibility of these integrated systems. This paper presents a framework for optimizing the size and dispatch strategy of CHP with PV and battery storage to minimize life-cycle cost of energy. The modeling methodology is presented, with a particular focus on the linearization of cost and performance metrics required for implementation in a mixed integer linear program. A case study is used to examine the technical and economic viability of integrated CHP, PV, and battery systems, compared to CHP-only or PV+battery storage systems. In the case study we show how the integrated systems can provide increased economic and resilience benefits compared to single technologies on their own. The case study presented shows the combined CHP, PV, and battery system resulted in a 7% lower life cycle cost than CHP only, and a 22% lower life cycle cost than PV+battery storage. The life cycle emissions for CHP, PV, and battery storage resulted in a 24% reduction than CHP only and a 17% increase than PV+battery storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear, Land marker for a Waste Isolation Site: International Architecture Competition - 18240

The design and construction of a nuclear waste marker must include many architectural considerations. Very little research has been conducted by architects to address this issue to date. Historically, the task of designating a nuclear waste site has been a discussion predominantly contained within the scientific and engineering communities. In an effort to engage architects within this dialogue, arch out loud hosted the NUCLEAR competition as an international, architectural investigation into the design of a nuclear waste site marker. The NUCLEAR competition asks participants to design a marker to designate the site of the Waste Isolation Pilot Plant (WIPP) located near Carlsbad, New Mexico. The marker will be meant to be a means of passive institutional controls (PICs) to deter inadvertent human intrusion upon the site and should last 10,000 years. The NUCLEAR competition defined the purpose of the nuclear waste site marker as a means to communicate the danger of inadvertent intrusion from future generations. The competition requires that entries must be both legible in communication and durable in their construction. The competition brief challenged participants to consider how customs and languages will evolve over time and to predict what motivations future generations might have for digging at the site. Other background information was provided about the site such as how waste was stored and how the unique geology of the site seals the waste. The 1993 Sandia National Laboratories report titled Expert Judgment on Markers to Deter Inadvertent Human Intrusion into the Waste Isolation Pilot Plant [1] was referenced along with the 1992 WIPP Land Withdrawal Act [2], interviews with WIPP scientists [3] involved with the WIPP PICs program and the Nuclear Energy Agency Records Knowledge and Memory working group. Competition participants were given digital 3-D Computer-Aided Design models for reference that included the underground storage portion of the site, existing buildings and the 16-square-mile site boundary identified in the 1992 WIPP Land Withdrawal Act [2]. This paper will: - Provide a detailed description of the submitted proposals including graphic analysis of the visualizations, diagrams, technical drawings, jury comments and statements. - Catalogue and identify the consistent themes within all submissions with possible categories including: 1) overall architectural form and language, 2) integration of written language and symbols within architecture, 3) use of technology and robotics, 4) construction methods and materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Recovery at Former Lithium Production Site at the Miramas in France - 18529

The former Lithium production facility located at Miramas in the South-East of France recently completed a 10-year program of process equipment removal, building demolition and soil remediation to recover mercury (Hg) that had been lost during operations at the site. After over 100 years ago chemical production, all production activities stopped in 2009, and immediately afterwards the clean-up project began. The main project focused on the demolition of all facilities and the decontamination of building materials and soil clean-up, with the goal of remediating the site for future industrial purposes. Prior to starting the decommissioning and clean-up work at the site a detailed site survey was conducted to identify the extent of the contamination of the site. After investigations into available technologies, the decision was made to install on-site treatment processes. This resulted in fewer residual environmental effects (trucking pollution, shipping containers, volume of materials, etc), a reduction in logistic complications, and, importantly, was cost effective compared to sending all untreated material to external processing facilities. This decision resulted in a need to optimize demolition waste management, while ensuring the highest clean-up and safety levels. A variety of treatment processes were investigated and compared and two technologies were finally selected and implemented. The first process was a 'thermal desorption unit (TDU),' which heated excavated soils and captured the vaporized mercury. The second was a washing process that was used to remove surface contamination. After the contaminated areas were excavated, materials were crushed, screened and sorted into different sizes, with each pile being routed to the appropriate process. The smaller-sized particles were treated in the TDU. A batch of around 12 MT was fed into a moisture evaporator and then into a mercury evaporator. The soils were then cooled, sampled to ensure no residual Hg contamination before being mixed with a binding agent, and returned to the excavation site. Larger materials with surface contamination were washed to remove the contamination. The liquid effluents were sent to a tank where the contaminated fines were removed, dried, pressed and sent for processing. If the washed, coarse materials failed to reach acceptable mercury levels, they were crushed again and sent to be treated in the TDU. The washing fluid was recycled for the next batch. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving and Automating Building Model Data Exchange

There are many instances throughout a project’s lifecycle where there arises a need for quick and accurate risk assessment of building designs. For example, an unexpected design change during construction may necessitate structural engineers to perform a seismic risk assessment on analytical models of the updated building design using high fidelity structural analysis software, such as ANSYS or Abaqus. However, the efficiency of such workflows often depends upon the interoperability of architectural design software and structural analysis software. When the quality of this interoperability is lacking or even non-existent, the efficiency of virtual engineering workflows is hampered, which increases project costs. A McGraw Hill industry survey of professional users of Building Information Modeling (BIM) technologies found that there is high demand for BIM interoperability for structural analysis, but that the value/difficulty ratio is currently too low for practical use. There have been efforts by the academic community to facilitate model data exchange between the architectural design and structural analysis domains, but such solutions have not been widely adopted by industry, face technical challenges, and oftentimes are limited in applicability for users of various BIM software. Therefore, INL is developing capabilities to improve, automate, and generalize model data exchange between architectural BIM software (e.g., Revit) and structural analysis software (e.g., SAP2000, ANSYS). The goal is to help expedite and automate as much of the pre-processing step for creating analytical models in finite element analysis software as reasonably as possible. Such a "BIM-to-FEA" conversion tool should provide direct benefit to end-users through accuracy, automation, quick turn-around, and wide applicability. To generalize the application of this BIM-to-FEA conversion tool and increase its useability among the many different commercial BIM software currently used by industry, the program is being developed with the concept of openBIM. OpenBIM is the application of non-proprietary, open data standards that allow for BIM model data exchange in a format that is accessible, retainable, and useable for all users. The most widely used open, non-proprietary data exchange format for BIM is the Industry Foundation Classes (IFC) schema. IFC is developed by buildingSMART international and is ISO certified (ISO 16739-1:2018). The BIM-to-FEA conversion tool is being developed for compatibility with typical commercial building designs of steel framed structures. The tool is currently capable of importing architectural BIM data of framed building structures, recognizing and extracting the aspects of the model that are required for structural analysis, adjusting the connectivity of frame members, and finally exporting to an analytical model stored in the IFC format. The exported IFC analytical model can then be imported into various openBIM compliant software, such as SAP2000. Such capabilities have already been tested on commercial software, as shown above, and continue to be improved. Work is underway to test the conversion on various commercial BIM software, develop a user-friendly interface, incorporate the program into the broader DeepLynx data warehouse project being developed by INL, and to eventually open-source the tool for the benefit of the community. Future development of the tool envisions the ability for efficient iterative risk assessment of generative building designs, all within a workflow utilizing open-source tools. One such open-source tool will be MOOSE, an advanced finite element analysis tool developed at INL. The conversion tool will also branch out from typical commercial building designs and will aim to incorporate nuclear construction. The aim will be to convert both structural and non-structural components of nuclear facilities, such as curved concrete containment structures and piping systems, respectively.

97 MATHEMATICS AND COMPUTING↗

Capability Building Progression of an Insider Threat Mitigation Program at International Nuclear Power Plant

With threats to nuclear facilities continuously evolving, the development and implementation of insider threat mitigation programs is increasingly important. The Office of International Nuclear Security within the U.S. Department of Energy’s National Nuclear Security Administration (DOE/NNSA’s) developed the “Insider Threat Mitigation Program: Facility Implementation Handbook” to assist organizations to be better positioned to minimize the risks posed by malicious insiders. The handbook identified eight elements that contribute to the development and implementation of insider threat mitigation programs. This report outlines the development of a capability building progression of an insider threat mitigation program at international nuclear power plants. This information can be stand-alone or be accompanied by a technical exchange with subject matter experts to support development and implementation of programs with interested international partners.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refueling infrastructure planning in intercity networks considering route choice and travel time delay for mixed fleet of electric and conventional vehicles

The range anxiety has been a major factor that affects the market acceptance of electric vehicles. Even with the recent development of battery technologies, a lack of charging stations and range anxiety are still significant concerns, specifically for intercity trips. This calls for more investments in building charging stations and advancing battery technologies to increase the market share of electric vehicles and improve sustainability. This study suggests a configuration for plug-in electric vehicle charging infrastructure to support long-distance intercity trips of electric vehicles at the network level. A model is proposed to minimize the total system cost including infrastructure investment (building charging stations/spots) and travel time delays (charging time, waiting time in the queue, and detour time to access charging stations). This study fills existing gaps in the literature by capturing realistic patterns of travel demand and considering flow-dependent charging delays at charging stations. Furthermore, the proposed model, which is formulated as a mixed-integer program with nonlinear constraints, solves the optimization problem at the network level. At the network level, impacts of charging station locations on the traffic assignment problem with a mixed fleet of electric and conventional vehicles need to be considered. To this end, a traffic assignment module is integrated with a simulated annealing algorithm. The numerical experiments show a satisfactory application of the model for a full-scale case study (intercity network in Michigan). The solution quality and efficiency of the proposed solution algorithm are evaluated against those of an enumeration approach for a small case study. The results suggest that even for the current market share and charging stations’ setting, a significant investment is needed to support intercity trips without range anxiety issues and with acceptable delays. Additionally, through sensitivity analyses, the required infrastructure and battery investments to support intercity trips with acceptable delays are established for hypothetical increased market shares and battery size in the future.

42 ENGINEERING↗

Energy information systems (EIS): Technology costs, benefit, and best practice uses

Energy information systems are the web-based software, data acquisition hardware, and communication systems used to store, analyze, and display building energy data. They often include analysis methods such as baselining, benchmarking, load profiling, and energy anomaly detection. This report documents a large-scale assessment of energy information system (EIS) uses, costs, and energy benefits, based on a series of focused case study investigations that are synthesized into generalizable findings. The overall objective is to provide organizational decision makers with the information they need to make informed choices as to whether or not to invest in an EIS--a promising technology that can enable up to 20 percent site energy savings, quick payback, and persistent low-energy performance when implemented as part of best-practice energy management programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Certification and Rating of Attachments for Fenestration Technologies

In the U.S., windows still represent a significant energy savings opportunity in residential and commercial buildings, and for decades the United States Department of Energy (DOE) has funded fenestration software tools, analysis, studies, and the National Fenestration Rating Council (NFRC). Despite significant developments in window technology and recognition of efficient products, studies conducted by the U.S. Energy Information Administration and Pacific Northwest National Laboratory (PNNL) found that approximately 64% of U.S. homes currently have inefficient windows. Window attachments (interior and exterior blinds, shades, storm windows, awnings, shutters, etc.) can offer a more cost-effective option to improve the energy performance of residential and commercial windows. In previous years, the window attachment industry attempted to work with the NFRC to generate a window attachment rating program, but was unable to access funding or technical resources necessary to address window attachments, which added many levels of complexity on top of NFRC’s scope of windows and glazing. Starting in 2014, the DOE Office of Energy Efficiency and Renewable Energy (EERE) funded the Window Coverings Manufacturing Association (WCMA) to develop the Attachments Energy Rating Council (AERC) along with policies and procedures to deliver an unbiased, credible, comparable, relevant, and cost-effective window attachment energy rating program for the residential and commercial sectors over a four-year period. This project was created because there were no consistent and credible performance rating mechanisms for assessing the energy performance of window attachments. Without a standardized approach, consumers found it difficult to make informed and comparative decisions about the energy performance of window attachments, and utilities faced challenges offering incentives for energy-efficient attachments. The goal of this project was two-fold: to develop procedures to rate and certify the energy performance of window attachments and to create an educational, consumer-facing Certified Products Website (CPW) to help consumers and other stakeholders make more informed window attachments purchasing decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evolution of Energy Efficiency Programs Over Time: The Case of Standby Power

Issued in 2001, Presidential Executive Order 13221 directed federal agencies to purchase products with low standby power, with the goal of 1) reducing energy consumption in federal facilities, and 2) drawing attention to the problem of high standby power consumption, with guidance provided by the Federal Energy Management Program (FEMP). At that time, standby power was newly recognized as an increasing building energy load. Since then, procurement of products with low standby power have been set in place in acquisition processes, and the purchasing power of the federal government continues to influence manufacturers design decisions related to standby power. In recent years, FEMP has shifted effort from direct manufacturer outreach for data collection, to integrating low standby requirement into broader acquisition programs including Energy Star and Electronic Product Environmental Assessment Tool (EPEAT). Another milestone has been the labeling of low standby products on the GSA Advantage website to simplify and enhance compliance. Looking forward into the program?s future, this question arises How do we design programs over time to reflect market and technology changes, by adjusting programmatic requirements while maintaining effectiveness? This paper discusses that question for the case of standby power, which transitioned from covering a single to multiple environmental attributes, both in the context of the program's past and future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evolution of Energy Efficiency Programs Over Time: The Case of Standby Power

Issued in 2001, Presidential Executive Order 13221 directed federal agencies to purchase products with low standby power, with the goal of 1) reducing energy consumption in federal facilities, and 2) drawing attention to the problem of high standby power consumption, with guidance provided by the Federal Energy Management Program (FEMP). At that time, standby power was newly recognized as an increasing building energy load. Since then, procurement of products with low standby power have been set in place in acquisition processes, and the purchasing power of the federal government continues to influence manufacturers’ design decisions related to standby power. In recent years, FEMP has shifted effort from direct manufacturer outreach for data collection, to integrating low standby requirement into broader acquisition programs including Energy Star and Electronic Product Environmental Assessment Tool (EPEAT). Another milestone has been the labeling of low standby products on the GSA Advantage website to simplify and enhance compliance. Looking forward into the program’s future, this question arises “How do we design programs over time to reflect market and technology changes, by adjusting programmatic requirements while maintaining effectiveness?” This paper discusses that question for the case of standby power, which transitioned from covering a single to multiple environmental attributes, both in the context of the program’s past and future.

Payne, CT↗

Contactless Position Measurement System for Remote Alignment of Highly Reflective Objects

The Contactless Position Measurement System (CPMS) permits automatic alignment of highly-reflecting components that cannot or should not be touched by human hands, such as those used in SRF cavities. CPMS also has application during maintenance of fusion reactors, when the components in the reactor are radioactive. The length of time for which humans can handle the components in order to carry out maintenance or repairs is limited. We would like to measure the relative positions of such objects so we can bring them into alignment with motorized stages, thus eliminating the need for human contact. The CPMS is a computer vision system that measures the location of highly reflective components to within a fraction of a millimeter by finding the edges of silhouette images. This is done by placing a uniform, infrared backlight behind the components, and viewing each component with two low-aberration, infrared cameras. Each of these stereoscopic cameras are located within a coordinate system we set up with reference platforms, light sources, and survey cameras distributed around the perimeter of the string assembly room, or fusion reactor. We obtain stereoscopic silhouette images of each component, and we use these to determine the position of the component within our string assembly coordinate system. The CPMS combines the silhouette images with knowledge of the dimensions of the objects to obtain the relative positions of components in its field of view. These position measurements then allow us to mechanically maneuver the components into contact. Once we know where they are, we can move the components to where they are supposed to be with motorized stages or other mechanical means, check they are in the right place, and bolt them together. In Phase I, we built a prototype infrared backlights and cameras, tested it, wrote an analysis program to fit the images. At a range of 50 cm, we are able to measure the relative positions of two stainless steel flanges with an accuracy of 150 μm rms. The next steps are to test the analysis program with motorized stages, build a full-size prototype, and implement it in an cleanroom with SRF cavity assembly. This can be done in a cost effective way given the materials with which the system is designed. As Open Source Instruments achieved more in Phase I than anticipated, despite not receiving a Phase II SBIR grant, we hope to move forward with product development and sales with a testing partner.

43 PARTICLE ACCELERATORS↗

Device Architecture Simplification of Laser Pattering in High-Volume Crystalline Silicon Solar Cell Fabrication using Intensive Computation for Design and Optimization

Prices of Si based solar modules have been continuously declining in recent years. Goodrich is pointing out that a significant portion of these cost reductions have come about due to ‘economies of scale’ benefits, but there is a point of diminishing returns when trying to lower cost by simply expanding production capacity. Developing innovative high volume production technologies resulting in an increase of conversion efficiency without adding significant production cost will be necessary to continue the projected cost reductions. The Foundational Program to Advance Cell Efficiency (FPACE) is seeking to achieve this by closing the PV efficiency gap between theoretical achievable maximum conversion efficiency - 29% for c-Si - and the current typical production - 18.5% for a typical full area back contact c-Si Solar cell – while targeting a module cost of $0.50/Watt . The research conducted by SolarWorldUSA and it’s partners within the FPACE framework focused on the development of a Hybrid metal-wrap-through (MWT) and laser-ablated PERC solar cell design employing a extrusion metallization scheme to achieve >20% efficient devices. The project team was able to simulate, develop and demonstrate the technologies necessary to build p-type MWT PERC cells with extruded front contacts. Conversion efficiencies approaching 20% were demonstrated and a path for further efficiency improvements identified. A detailed cost of ownership calculation for such a device was based on a NREL cost model and is predicting a $/Watt cost below 85 cents on a 180 micron substrate.

14 SOLAR ENERGY↗