Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparisons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The T{sub z} = -1{yields}T{sub z} =0 beta decays and comparison with Charge Exchange reactions

Gamow-Teller (GT) transitions can be studied in both {beta} decay and charge exchange (CE) reactions. If isospin is a good quantum number, then the Tz = -1{yields}0 and Tz = +1{yields}0GT mirror transitions, are identical. Therefore, a comparison of the results from studies of {beta} decay and CE should shed light on this assumption. Accordingly we have studied the {beta} decay of the Tz = -1 fp-shell nuclei, {sup 54}Ni, {sup 50}Fe, {sup 46}Cr, and {sup 42}Ti, produced in fragmentation and we have compared our results with the spectra from ({sup 3}He, t) measurements on the mirror Tz = +1 target nuclei studied in high resolution at RCNP, Osaka. The {beta} decay experiments were performed as part of the STOPPED beam RISING campaign at GSI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of plasma current dependent changes in impurity transport and comparison with nonlinear gyrokinetic simulation

Measured impurity transport coefficients are found to demonstrate a strong dependence on plasma current in the core of Alcator C-Mod. These measurements are compared directly with linear and nonlinear gyrokinetic simulation in an attempt to both qualitatively and quantitatively reproduce the measured impurity transport. Discharges constituting a scan of plasma current from 0.6 to 1.2 MA were performed during the 2010 run campaign. The impurity transport from these discharges was determined using a novel set of spectroscopic diagnostics available on Alcator C-Mod. This diagnostic suite allowed for the effective constraint of impurity transport coefficient profiles inside of r/a = 0.6. A decrease in the measured impurity diffusivity and inward convection is found with increased plasma current. Global, nonlinear gyrokinetic simulations were performed using the GYRO code [J. Candy and R. E. Waltz, J Comput. Phys. 186, 545 (2003)] for all discharges in the experimental scan and are found to reproduce the experimental trends, while demonstrating good quantitative agreement with measurement. A more comprehensive quantitative comparison was performed on the 0.8 MA discharge of the current scan which demonstrates that simultaneous agreement between experiment and simulation in both the impurity particle transport and ion heat transport channels is attainable within experimental uncertainties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Drift kinetic effects on the resistive wall mode stability-Comparison between reversed field pinches and tokamaks

The physics of kinetic effects on the resistive wall mode (RWM) stability is studied, and a comparison between reversed field pinch (RFP) and Tokamak configurations is made. The toroidal, magnetohydrodynamic (MHD)-kinetic hybrid stability code MARS-K, in which the drift kinetic effects are self-consistently incorporated into the MHD formulation, is upgraded with an extensive energy analysis module. In the tokamak configuration, the kinetic effect can stabilize the mode with very slow, or vanishing plasma rotation, due to the mode resonance with the toroidal precession drift of thermal trapped particles. In RFP, instead, stabilization of the RWM comes mainly from the ion acoustic Landau damping (i.e., the transit resonance of passing particles). In the high beta region, the critical flow rotation frequency required for the mode stabilization is predicted to be in the ion acoustic range. Detailed physical analyses, based on the perturbed potential energy components, have been performed to gain understanding of the stabilizing mechanism in the two different systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparisons of NIF convergent ablation simulations with radiograph data

A technique for comparing simulation results directly with radiograph data from backlit capsule implosion experiments will be discussed. Forward Abel transforms are applied to the kappa*rho profiles of the simulation. These provide the transmission ratio (optical depth) profiles of the simulation. Gaussian and top hat blurs are applied to the simulated transmission ratio profiles in order to account for the motion blurring and imaging slit resolution of the experimental measurement. Comparisons between the simulated transmission ratios and the radiograph data lineouts are iterated until a reasonable backlighter profile is obtained. This backlighter profile is combined with the blurred, simulated transmission ratios to obtain simulated intensity profiles that can be directly compared with the radiograph data. Examples will be shown from recent convergent ablation (backlit implosion) experiments at the NIF.

Olson, R. E.↗

Comparison of nuclear mass models at nuclearmasses.org

Nuclear masses are crucial in many astrophysics studies, as well as other areas of basic and applied nuclear science. There are now many different global theoretical models of nuclear masses - but choosing the best model for a given application can be challenging. The suite of codes online at nuclearmasses.org greatly facilitates the comparison of nuclear models with evaluated masses as well as the intercomparison of theoretical models. We demonstrate the utility of this suite by comparing the RMS deviations of 13 different theoretical mass models from the AME2003 evaluated masses over mass ranges appropriate for astrophysics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison for non-local hydrodynamic thermal conduction models

Inertial confinement fusion and specifically shock ignition involve temperatures and temperature gradients for which the classical Spitzer-Haerm thermal conduction breaks down and a non-local operator is required. In this article, two non-local electron thermal conduction models are tested against kinetic Vlasov-Fokker-Planck simulations. Both models are shown to reproduce the main features of thermal heat front propagation at kinetic timescales. The reduction of the thermal conductivity as a function of the scalelength of the temperature gradient is also recovered. Comparisons at nanosecond timescales show that the models agree on the propagation velocity of the heat front, but major differences appear in the thermal precursor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison between hybrid and fully kinetic models of asymmetric magnetic reconnection: Coplanar and guide field configurations

Magnetic reconnection occurring in collisionless environments is a multi-scale process involving both ion and electron kinetic processes. Because of their small mass, the electron scales are difficult to resolve in numerical and satellite data, it is therefore critical to know whether the overall evolution of the reconnection process is influenced by the kinetic nature of the electrons, or is unchanged when assuming a simpler, fluid, electron model. This paper investigates this issue in the general context of an asymmetric current sheet, where both the magnetic field amplitude and the density vary through the discontinuity. A comparison is made between fully kinetic and hybrid kinetic simulations of magnetic reconnection in coplanar and guide field systems. The models share the initial condition but differ in their electron modeling. It is found that the overall evolution of the system, including the reconnection rate, is very similar between both models. The best agreement is found in the guide field system, which confines particle better than the coplanar one, where the locality of the moments is violated by the electron bounce motion. It is also shown that, contrary to the common understanding, reconnection is much faster in the guide field system than in the coplanar one. Both models show this tendency, indicating that the phenomenon is driven by ion kinetic effects and not electron ones.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

The Forschungszentrum Juelich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA). The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of some elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of toroidicity-induced Alfvén eigenmodes and energetic particle modes by gyrokinetic particle simulations

This work reports on linear global gyrokinetic particle simulations of the excitation of toroidicity-induced Alfvén eigenmodes (TAE) and energetic particle modes (EPM), and the comparison between these two modes. The TAE excitation by antenna clarifies the magnetohydrodynamic (MHD) mode structure and the discrete eigenmode exists in the gap between the upper and lower accumulation points. The TAE excitation by fast ions modifies the MHD mode structure because of radial symmetry breaking and the eigenmode frequency moves towards the lower accumulation point. The phase space structure of fast ions shows that both passing and trapped particles contribute to the TAE excitation and that trapped particles dominate the wave-particle resonance in our simulations. The growth rate of TAE is sensitive to the fast ion energy, density, and density gradient, which are also important factors contributing to the transition of the TAE to the EPM. The gyrokinetic particle simulations also confirm the excitation of EPM when the drive is stronger. The frequency of the EPM is determined by the characteristic frequencies of fast ion motion in toroidal geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of erythemally weighted broadband instruments: A comparison between PMOD/WRC and MSL

A Yankee Environmental Systems (YES) UVB-1 ultraviolet pyranometer, designed to measure erythemally weighted total solar irradiance, was calibrated by the Measurement Standards Laboratory (MSL) in Lower Hutt, New Zealand during August 2010. The calibration was then repeated during July and August 2011 by the Physikalisch-Meteorologisches Obervatorium Davos, World Radiation Center (PMOD/WRC) located in Davos, Switzerland. Calibration results show that measurements of the relative spectral and angular response functions at the two institutes are in excellent agreement, thus providing a good degree of confidence in these measurement facilities. However, measurements to convert the relative spectral response into an absolute calibration disagree significantly depending on whether an FEL lamp or solar spectra are used to perform this scaling. This is the first serious comparison of these scaling methods to formally explore the potential systematic errors which could explain the discrepancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparisons of linear and nonlinear plasma response models for non-axisymmetric perturbations

With the installation of non-axisymmetric coil systems on major tokamaks for the purpose of studying the prospects of ELM-free operation, understanding the plasma response to the applied fields is a crucial issue. Application of different response models, using standard tools, to DIII-D discharges with applied non-axisymmetric fields from internal coils, is shown to yield qualitatively different results. The plasma response can be treated as an initial value problem, following the system dynamically from an initial unperturbed state, or from a nearby perturbed equilibrium approach, and using both linear and nonlinear models [A. D. Turnbull, Nucl. Fusion 52, 054016 (2012)]. Criteria are discussed under which each of the approaches can yield a valid response. In the DIII-D cases studied, these criteria show a breakdown in the linear theory despite the small 10{sup −3} relative magnitude of the applied magnetic field perturbations in this case. For nonlinear dynamical evolution simulations to reach a saturated nonlinear steady state, appropriate damping mechanisms need to be provided for each normal mode comprising the response. Other issues arise in the technical construction of perturbed flux surfaces from a displacement and from the presence of near nullspace normal modes. For the nearby equilibrium approach, in the absence of a full 3D equilibrium reconstruction with a controlled comparison, constraints relating the 2D system profiles to the final profiles in the 3D system also need to be imposed to assure accessibility. The magnetic helicity profile has been proposed as an appropriate input to a 3D equilibrium calculation and tests of this show the anticipated qualitative behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of laser-based and monochromator-based thermodynamic temperature measurements

In this work, we describe comparisons between a laser-based and a monochromator-based radiance responsivity calibration of a radiation thermometer. The spectral selection of the radiation thermometer is performed using a spectrally broad photopic-response filter which was selected to minimize effects of convolution differences due to the spectral width of the laser-and the monochromator-based sources. The photopic-response filter is physically thick, which should also reduce possible interference fringes which can be problematic in the laser-based calibrations. We compare the radiance responsivities obtained using the two approaches and also compare the blackbody temperatures determined using the detector/monochromator based and the gold-point based calibration methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser ablation of iron: A comparison between femtosecond and picosecond laser pulses

In this study, a comparison between femtosecond (fs) and picosecond (ps) laser ablation of electrolytic iron was carried out in ambient air. Experiments were conducted using a Ti:sapphire laser that emits radiation at 785 nm and at pulse widths of 110 ps and 130 fs, before and after pulse compression, respectively. Ablation rates were calculated from the depth of craters produced by multiple laser pulses incident normally to the target surface. Optical and scanning electron microscopy showed that picosecond laser pulses create craters that are deeper than those created by the same number of femtosecond laser pulses at the same fluence. Most of the ablated material was ejected from the ablation site in the form of large particles (few microns in size) in the case of picosecond laser ablation, while small particles (few hundred nanometers) were produced in femtosecond laser ablation. Thermal effects were apparent at high fluence in both femtosecond and picosecond laser ablation, but were less prevalent at low fluence, closer to the ablation threshold of the material. The quality of craters produced by femtosecond laser ablation at low fluence is better than those created at high fluence or using picosecond laser pulses.

36 MATERIALS SCIENCE↗

Comparison of direct and indirect positron-generation by an ultra-intense femtosecond laser

An extensive comparison of the properties of positron beams produced by an ultra-intense femtosecond laser in direct and indirect schemes has been performed with two-dimensional particle-in-cell and Monte Carlo simulations. It is shown that the positron beam generated in the indirect scheme has a higher yield (10{sup 10}), a higher temperature (28.8 MeV), a shorter pulse duration (5 ps), and a smaller divergence (8°) than in the direct case (10{sup 9} yield, 4.4 MeV temperature, 40 ps pulse duration, and 60° divergence). In addition, it was found that the positron/gamma ratio in the indirect scheme is one order of magnitude higher than that in the direct one, which represents a higher signal/noise ratio in positron detection. Nevertheless, the direct generation method still has its own unique advantage, the so-called target normal sheath acceleration, which can result in quasi-monoenergetic positron beams that may serve in some specialized applications.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of light out-coupling enhancements in single-layer blue-phosphorescent organic light emitting diodes using small-molecule or polymer hosts

Single-layer blue phosphorescence organic light emitting diodes (OLEDs) with either small-molecule or polymer hosts are fabricated using solution process and the performances of devices with different hosts are investigated. The small-molecule device exhibits luminous efficiency of 14.7 cd/A and maximum power efficiency of 8.39 lm/W, which is the highest among blue phosphorescence OLEDs with single-layer solution process and small molecular hosts. Using the same solution process for all devices, comparison of light out-coupling enhancement, with brightness enhancement film (BEF), between small-molecule and polymer based OLEDs is realized. Due to different dipole orientation and anisotropic refractive index, polymer-based OLEDs would trap less light than small molecule-based OLEDs internally, about 37% better based simulation results. In spite of better electrical and spectroscopic characteristics, including ambipolar characteristics, higher carrier mobility, higher photoluminescence quantum yield, and larger triplet state energy, the overall light out-coupling efficiency of small molecule-based devices is worse than that of polymer-based devices without BEF. However, with BEF for light out-coupling enhancement, the improved ratio in luminous flux and luminous efficiency for small molecule based device is 1.64 and 1.57, respectively, which are significantly better than those of PVK (poly-9-vinylcarbazole) devices. In addition to the theoretical optical simulation, the experimental data also confirm the origins of differential light-outcoupling enhancement. The maximum luminous efficiency and power efficiency are enhanced from 14.7 cd/A and 8.39 lm/W to 23 cd/A and 13.2 lm/W, respectively, with laminated BEF, which are both the highest so far for single-layer solution-process blue phosphorescence OLEDs with small molecule hosts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison between Gaussian-type orbitals and plane wave ab initio density functional theory modeling of layer silicates: Talc [Mg{sub 3}Si{sub 4}O{sub 10}(OH){sub 2}] as model system

The quantum chemical characterization of solid state systems is conducted with many different approaches, among which the adoption of periodic boundary conditions to deal with three-dimensional infinite condensed systems. This method, coupled to the Density Functional Theory (DFT), has been proved successful in simulating a huge variety of solids. Only in relatively recent years this ab initio quantum-mechanic approach has been used for the investigation of layer silicate structures and minerals. In the present work, a systematic comparison of different DFT functionals (GGA-PBEsol and hybrid B3LYP) and basis sets (plane waves and all-electron Gaussian-type orbitals) on the geometry, energy, and phonon properties of a model layer silicate, talc [Mg{sub 3}Si{sub 4}O{sub 10}(OH){sub 2}], is presented. Long range dispersion is taken into account by DFT+D method. Results are in agreement with experimental data reported in literature, with minimal deviation given by the GTO/B3LYP-D* method regarding both axial lattice parameters and interaction energy and by PW/PBE-D for the unit-cell volume and angular values. All the considered methods adequately describe the experimental talc infrared spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OSLD energy response performance and dose accuracy at 24 - 1250 keV: Comparison with TLD-100H and TLD-100

OSLD was evaluated in terms of energy response and accuracy of the measured dose in comparison with TLD-100H and TLD-100. The OSLD showed a better energy response performance for H{sub p}(10) whereas for H{sub p}(0.07), TLD-100H is superior than the others. The OSLD dose accuracy is comparable with the other two dosimeters since it fulfilled the requirement of the ICRP trumpet graph analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Film-coupled nanoparticles by atomic layer deposition: Comparison with organic spacing layers

Film-coupled nanoparticle systems have proven a reliable platform for exploring the field enhancement associated with sub-nanometer sized gaps between plasmonic nanostructures. In this Letter, we present a side-by-side comparison of the spectral properties of film-coupled plasmon-resonant, gold nanoparticles, with dielectric spacer layers fabricated either using atomic layer deposition or using organic layers (polyelectrolytes or self-assembled monolayers of molecules). In either case, large area, uniform spacer layers with sub-nanometer thicknesses can be accurately deposited, allowing extreme coupling regimes to be probed. The observed spectral shifts of the nanoparticles as a function of spacer layer thickness are similar for the organic and inorganic films and are consistent with numerical calculations taking into account the nonlocal response of the metal.

36 MATERIALS SCIENCE↗