Search NASA⌕ Search

SEARCH · Search NASA

Results for “design space approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

A Summary of Test Results from a NASA Lift + Cruise eVTOL Crash Test

On November 9, 2022, the National Aeronautics and Space Administration (NASA) conducted a full-scale crash test of the NASA Lift+Cruise (LPC) reference vehicle at the NASA Langley Research Center Landing and Impact Research Facility (LandIR) under combined vertical and horizontal impact conditions to simulate a severe but survivable crash. The LPC test article is a carbon-composite skin/frame structure design, developed and fabricated for the cabin section only. The test utilized various configurations of seats and Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) intended to encompass a variety of occupant conditions. In addition, an in-house developed energy absorbing subfloor was utilized for the evaluation of load attenuation. Overhead mass was simulated using attached lifting hardware and other systems were simulated using ballast mass. The test article impacted the ground with velocities of 38.1 ft/s horizontal and 31.4 ft/s vertical. During the first approximately 38 milliseconds (ms), the cabin section experienced a large amount of acceleration on the belly which was attenuated by the subfloor structures and seats. Over the next approximately 160 ms, the test article experienced failure in the a-, b- and c-pillars, leading to a partial collapse of the overhead structure. Test data was collected on the belly, floors, seats, overhead mass, and tail. In addition, there was high speed full-field digital image correlation analysis data collected on the port side skin surface. Collected ATD data showed that the ATDs seated in the energy absorbing seats experienced loads at limits below the those in current regulations. Even without an energy absorbing seat, the energy absorbing subfloors crushed as intended, and limited the load on the large 95 th percentile ATD to 10% over suggested limits. The collapse of the roof did affect the 95 th percentile ATD, which showed high neck loading values due to head contact, whereas survivable volume was maintained for the other ATDs. While the energy absorbing subfloor and energy absorbing seats both contributed to occupant load attenuation, further optimization is suggested to increase their robustness.

evtol↗

A Summary of Test Results from a NASA Lift + Cruise eVTOL Crash Test

On November 9, 2022, the National Aeronautics and Space Administration (NASA) conducted a full-scale crash test of the NASA Lift+Cruise (LPC) reference vehicle at the NASA Langley Research Center Landing and Impact Research Facility (LandIR) under combined vertical and horizontal impact conditions to simulate a severe but survivable crash. The LPC test article is a carbon-composite skin/frame structure design, developed and fabricated for the cabin section only. The test utilized various configurations of seats and Anthropomorphic Test Devices (ATDs, a.k.a. crash test dummies) intended to encompass a variety of occupant conditions. In addition, an in-house developed energy absorbing subfloor was utilized for the evaluation of load attenuation. Overhead mass was simulated using attached lifting hardware and other systems were simulated using ballast mass. The test article impacted the ground with velocities of 38.1 ft/s horizontal and 31.4 ft/s vertical. During the first approximately 38 milliseconds (ms), the cabin section experienced a large amount of acceleration on the belly which was attenuated by the subfloor structures and seats. Over the next approximately 160 ms, the test article experienced failure in the a-, b- and c-pillars, leading to a partial collapse of the overhead structure. Test data was collected on the belly, floors, seats, overhead mass, and tail. In addition, there was high speed full-field digital image correlation analysis data collected on the port side skin surface. Collected ATD data showed that the ATDs seated in the energy absorbing seats experienced loads at limits below the those in current regulations. Even without an energy absorbing seat, the energy absorbing subfloors crushed as intended, and limited the load on the large 95 th percentile ATD to 10% over suggested limits. The collapse of the roof did affect the 95 th percentile ATD, which showed high neck loading values due to head contact, whereas survivable volume was maintained for the other ATDs. While the energy absorbing subfloor and energy absorbing seats both contributed to occupant load attenuation, further optimization is suggested to increase their robustness.

evtol↗

Electromagnetic propulsion for spacecraft

Three electromagnetic propulsion technologies, solid propellant pulsed plasma thrusters (PPT), magnetoplasmadynamic (MPD) thrusters, and pulsed inductive thrusters (PIT), were developed for application to auxiliary and primary spacecraft propulsion. Both the PPT and MPD thrusters were flown in space, though only PPT's were used on operational satellites. The performance of operational PPT's is quite poor, providing only approximately 8 percent efficiency at approximately 1000 s specific impulse. However, laboratory PPT's yielding 34 percent efficiency at 2000 s specific impulse were extensively tested, and peak performance levels of 53 percent efficiency at 5170 s specific impulse were demonstrated. MPD thrusters were flown as experiments on the Japanese MS-T4 spacecraft and the Space Shuttle and were qualified for a flight in 1994. The flight MPD thrusters were pulsed, with a peak performance of 22 percent efficiency at 2500 s specific impulse using ammonia propellant. Laboratory MPD thrusters were demonstrated with up to 70 percent efficiency and 700 s specific impulse using lithium propellant. While the PIT thruster has never been flown, recent performance measurements using ammonia and hydrazine propellants are extremely encouraging, reaching 50 percent efficiency for specific impulses between 4000 to 8000 s. The fundamental operating principles, performance measurements, and system level design for the three types of electromagnetic thrusters are reviewed, and available data on flight tests are discussed for the PPT and MPD thrusters.

Myers, Roger M.↗

A Vibration Isolation System for Use in a Large Thermal Vacuum Test Facility

A thermal vacuum payload platform that is isolated from background vibration is required to support the development of future instruments for Hubble Space Telescope (HST) and the Next Generation Space Telescope (NGST) at the Goddard Space Flight Center (GSFC). Because of the size and weight of the thermal/vacuum facility in which the instruments are tested, it is not practical to isolate the entire facility externally. Therefore, a vibration isolation system has been designed and fabricated to be installed inside the chamber. The isolation system provides a payload interface of 3.05 m (10 feet) in diameter and is capable of supporting a maximum payload weight of 4536 kg (10,000 Lbs). A counterweight system has been included to insure stability of payloads having high centers of gravity. The vibration isolation system poses a potential problem in that leakage into the chamber could compromise the ability to maintain vacuum. Strict specifications were imposed on the isolation system design to minimize leakage. Vibration measurements, obtained inside the chamber, prior to installing the vibration isolation system, indicated levels in all axes of approximately 1 milli-g at about 20 Hz. The vibration isolation system was designed to provide a minimum attenuation of 40 dB to these levels. This paper describes the design and testing of this unique vibration isolation system. Problems with leakage and corrective methods are presented. Isolation performance results are also presented.

Hershfeld, Donald↗

Improved Lunar Lander Handling Qualities Through Control Response Type and Display Enhancements

A piloted simulation that studied the handling qualities for a precision lunar landing task from final approach to touchdown is presented. A vehicle model based on NASA's Altair Lunar Lander was used to explore the design space around the nominal vehicle configuration to determine which combination of factors provides satisfactory pilot-vehicle performance and workload; details of the control and propulsion systems not available for that vehicle were derived from Apollo Lunar Module data. The experiment was conducted on a large motion base simulator. Eight Space Shuttle and Apollo pilot astronauts and three NASA test pilots served as evaluation pilots, providing Cooper-Harper ratings, Task Load Index ratings and qualitative comments. Each pilot flew seven combinations of control response types and three sets of displays, including two varieties of guidance and a nonguided approach. The response types included Rate Command with Attitude Hold, which was used in the original Apollo Moon landings, a Velocity Increment Command response type designed for up-and-away flight, three response types designed specifically for the vertical descent portion of the trajectory, and combinations of these. It was found that Velocity Increment Command significantly improved handling qualities when compared with the baseline Apollo design, receiving predominantly Level 1 ratings. This response type could be flown with or without explicit guidance cues, something that was very difficult with the baseline design, and resulted in approximately equivalent touchdown accuracies and propellant burn as the baseline response type. The response types designed to be used exclusively in the vertical descent portion of the trajectory did not improve handling qualities.

Mueller, Eric Richard↗

Evaluating the High School Lunar Research Projects Program

The Center for Lunar Science and Exploration (CLSE), a collaboration between the Lunar and Planetary Institute and NASA s Johnson Space Center, is one of seven member teams of the NASA Lunar Science Institute (NLSI). In addition to research and exploration activities, the CLSE team is deeply invested in education and outreach. In support of NASA s and NLSI s objective to train the next generation of scientists, CLSE s High School Lunar Research Projects program is a conduit through which high school students can actively participate in lunar science and learn about pathways into scientific careers. The objectives of the program are to enhance 1) student views of the nature of science; 2) student attitudes toward science and science careers; and 3) student knowledge of lunar science. In its first three years, approximately 168 students and 28 teachers from across the United States have participated in the program. Before beginning their research, students undertake Moon 101, a guided-inquiry activity designed to familiarize them with lunar science and exploration. Following Moon 101, and guided by a lunar scientist mentor, teams choose a research topic, ask their own research question, and design their own research approach to direct their investigation. At the conclusion of their research, teams present their results to a panel of lunar scientists. This panel selects four posters to be presented at the annual Lunar Science Forum held at NASA Ames. The top scoring team travels to the forum to present their research in person.

Shaner, A. J.↗

Exploring Network-Related Optimization Problems Using Quantum Heuristics

Network-related connectivity optimization problems are underlying a wide range of applications and are also of high computational complexity. We consider studying network optimization problems using two types of quantum heuristics.One is quantum annealing, and the other Quantum Alternating Operator Ansatz, an extension of the Quantum Approximate Optimization Algorithms for gate-model quantum computation, in which a cost-function based unitary and a non-commuting mixing unitary are applied alternately. We present problem mappings for problems of finding the spanning-tree or spanning-graph of a graph that optimizes certain costs, and a variant that further requires the spanning-tree be degree-bounded. With quantum annealing, all constraints are cast into penalty terms in the cost Hamiltonian, and the solution is encoded as the ground state of the Hamiltonian. We provide three mappings to the quadratic unconstrained binary optimization (QUBO) form, compare the resource requirements, and analyze the tradeoffs. For QAOA, we give special focus on the design of mixers based on the constraints presented in the problem, such that the system evolution remains in a subspace of the full Hilbert space where all constraints are satisfied. In the spanning-tree problem, one such hard constraint is that a mixer applied to a spanning-tree needs also be a spanning tree. This involves checking the connectivity of a subgraph, which is a global condition common for most network-related problems. We show how this feature can be efficiently represented in the mixer in a quantum coherent way, based on manipulation of a descendant-matrix and an adjacent matrix. We further develop a mixer for the spanning-graphs based on the spanning-tree mixer.

Wang, Zhihui↗

Study network-related optimization problems using quantum alternating optimization ansatz

Network-related connectivity optimization problems are underlying a wide range of applications and are also of high computational complexity. We consider studying network optimization problems using two types of quantum heuristics. One is quantum annealing, and the other Quantum Alternating Operator Ansatz, an extension of the Quantum Approximate Optimization Algorithms for gate-model quantum computation, in which a cost-function based unitary and a non-commuting mixing unitary are applied alternately. We present problem mappings for problems of finding the spanning-tree or spanning-graph of a graph that optimizes certain costs, and a variant that further requires the spanning-tree be degree-bounded. With quantum annealing, all constraints are cast into penalty terms in the cost Hamiltonian, and the solution is encoded as the ground state of the Hamiltonian. We provide three mappings to the quadratic unconstrained binary optimization (QUBO) form, compare the resource requirements, and analyze the tradeoffs. For QAOA, we give special focus on the design of mixers based on the constraints presented in the problem, such that the system evolution remains in a subspace of the full Hilbert space where all constraints are satisfied. In the spanning-tree problem, one such hard constraint is that a mixer applied to a spanning-tree needs also be a spanning tree. This involves checking the connectivity of a subgraph, which is a global condition common for most network-related problems. We show how this feature can be efficiently represented in the mixer in a quantum coherent way, based on manipulation of a descendant-matrix and an adjacent matrix. We further develop a mixer for the spanning-graphs based on the spanning-tree mixer.

Zhihui Wang↗

TARDIS: Acelerating TVAC Transitions

"Large spacecraft components, including instruments, require long durations to transition between temperature plateaus during TVAC (Thermal Vacuum) testing. This is especially true for cryogenic instruments whose operating temperatures are extremely low. Due to the T4 relation, using radiative heat transfer alone for temperature transitions to cryogenic temperatures is extremely time consuming. The Wide Field Instrument (WFI) on the upcoming Roman Space Telescope (RST) is one such cryogenic instrument. The TARDIS (Thermal Acceleration Rate Device for Integrated Systems) is a heat switch device which will be used during the WFI TVAC test campaign in order to decrease WFI transition times. Over the course of the planned ___ week WFI instrument-level TVAC testing, TARDIS is being estimated to save ___ days of test time. By reducing the total TVAC duration, TARDIS is providing significant cost and schedule savings to the RST WFI project. Based on the successful design of the LUCY L’Ralph AZQ Heat Switch, TARDIS can provide both high conductivity for temperature transitions and low conductivity Zero-Q for thermal balances. This is achieved by use of a mechanical clamp heat switch and actively controlled cold plate. Using this method, TARDIS is estimated to be able to change its conductance from approximately 0.20 W/K to ¬¬0.002 W/K, for a turndown ratio of 100. This paper details the design, analysis, and testing of TARDIS. It also previews the operation of TARDIS in the upcoming WFI TVAC test campaign. "

TVAC, Heat Switch↗

The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Pre-Flight Planning

The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services (CLPS) initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University (OU), NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of an ESA-provided Exospheric Mass Spectrometer (EMS; including sensor, electronics, controller, power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in a radiofrequency field, then sequentially released to a detector to build a mass spectrum. PITMS was capable of measuring species with a massto-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.

Barbara Cohen↗

Crew Scheduling Performance

As NASA considers long-duration exploration missions (LDEMs), it is envisioned that crew will behave more autonomously as compared to low-Earth orbit missions. The necessary shift of Ops Planners’ complete management of scheduling and planning to provide flexibility for crew to manage their own schedule in real-time requires significant research and investigation in evaluation of concepts of operations, of software tools to support tasks, and of crew performance to complete scheduling tasks. Our research objective is to characterize the human performance envelope for the task of planning and scheduling (crew self-scheduling), develop countermeasures to mitigate adverse performance effects due to plan complexity, and inform performance standards and guidelines based on research results. In our efforts to understand and characterize scheduling performance of crew members, we have conducted subject matter expert interviews to obtain feedback on scheduling plan complexity drivers and plan goodness. Following the pilot study conducted last year, we designed a study and have begun remote human subject testing to evaluate non-expert human performance, workload, and situational awareness for the task of planning and scheduling. This study investigates the effects of the number and type of constraints on human performance, and the differences in scheduling metrics between scheduling and rescheduling tasks. Subject testing is currently in progress, and we aim to collect data from approximately thirty subjects. We will summarize the methods used and impacts of the number and type of scheduling constraints. We will also present lessons learned as well as relevant results of the study.

crew scheduling↗

Goal-oriented sensitivity analysis for lattice kinetic Monte Carlo simulations

In this paper we propose a new class of coupling methods for the sensitivity analysis of high dimensional stochastic systems and in particular for lattice Kinetic Monte Carlo (KMC). Sensitivity analysis for stochastic systems is typically based on approximating continuous derivatives with respect to model parameters by the mean value of samples from a finite difference scheme. Instead of using independent samples the proposed algorithm reduces the variance of the estimator by developing a strongly correlated-“coupled”- stochastic process for both the perturbed and unperturbed stochastic processes, defined in a common state space. The novelty of our construction is that the new coupled process depends on the targeted observables, e.g., coverage, Hamiltonian, spatial correlations, surface roughness, etc., hence we refer to the proposed method as goal-oriented sensitivity analysis. In particular, the rates of the coupled Continuous Time Markov Chain are obtained as solutions to a goal-oriented optimization problem, depending on the observable of interest, by considering the minimization functional of the corresponding variance. We show that this functional can be used as a diagnostic tool for the design and evaluation of different classes of couplings. Furthermore, the resulting KMC sensitivity algorithm has an easy implementation that is based on the Bortz–Kalos–Lebowitz algorithm's philosophy, where events are divided in classes depending on level sets of the observable of interest. Finally, we demonstrate in several examples including adsorption, desorption, and diffusion Kinetic Monte Carlo that for the same confidence interval and observable, the proposed goal-oriented algorithm can be two orders of magnitude faster than existing coupling algorithms for spatial KMC such as the Common Random Number approach. We also provide a complete implementation of the proposed sensitivity analysis algorithms, including various spatial KMC examples, in a supplementary MATLAB source code.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design considerations for a Space Station radiation shield for protection from both man-made and natural sources

This study was conducted to analyze scenarios involving the use of nuclear-power vehicles in the vicinity of a manned Space Station (SS) in low-earth-orbit (LEO) to quantify their radiological impact to the station crew. In limiting the radiant dose to crew members, mission planners may (1) shut the reactor down prior to reentry, (2) position the vehicle at a prescribed parking distance, and (3) deploy radiation shield about the shutdown reactor. The current report focuses on the third option in which point-kernel gamma-ray shielding calculations were performed for a variety of shield configurations for both nuclear electric propulsion (NEP) and nuclear thermal rocket (NTR) vehicles. For a returning NTR vehicle, calculations indicate that a 14.9 MT shield would be needed to limit the integrated crew exposure to no more than 0.05 Sv over a period of six months (25 percent of the allowable exposure to man-made radiation sources). During periods of low vehicular activity in LEO, the shield may be redeployed about the SS habitation module in order to decrease crew exposures to trapped proton radiations by approximately a factor of 10. The corresponding shield mass required for deployment at a returning NEP vehicle is 2.21 MT. Additional scenarios examined include the radioactivation of various metals as might be found in tools used in EVA activities.

Bolch, Wesley E.↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-508: A Collimator-Based 3-Dimensional Grid Therapy Technique in a Small Animal Radiation Research Platform

Purpose: Three dimensional (3D) Grid Therapy using MLC-based inverse-planning has been proposed to achieve the features of both conformal radiotherapy and spatially fractionated radiotherapy, which may deliver very high dose in a single fraction to portions of a large tumor with relatively low normal tissue dose. However, the technique requires relatively long delivery time. This study aims to develop a collimator-based 3D grid therapy technique. Here we report the development of the technique in a small animal radiation research platform. Methods: Similar as in the MLC-based technique, 9 non-coplanar beams in special channeling directions were used for the 3D grid therapy technique. Two specially designed grid collimators were fabricated, and one of them was selectively used to match the corresponding gantry/couch angles so that the grid opening of all 9 beams are met in the 3D space in the target. A stack of EBT3 films were used as 3D dosimetry to demonstrate the 3D grid-like dose distribution in the target. Three 1-mm beams were delivered to the stack of films in the area outside the target for alignment when all the films were scanned to reconstruct the 3D dosimtric image. Results: 3D film dosimetry showed a lattice-like dose distribution in the 3D target as well as in the axial, sagittal and coronal planes. The dose outside the target also showed a grid like dose distribution, and the average dose gradually decreased with the distance to the target. The peak to valley ratio was approximately 5:1. The delivery time was 7 minutes for 18 Gy peak dose, comparing to 6 minutes to deliver a 18-Gy 3D conformal plan. Conclusion: We have demonstrated the feasibility of the collimator-based 3D grid therapy technique which can significantly reduce delivery time comparing to MLC-based inverse planning technique.

60 APPLIED LIFE SCIENCES↗

Some Considerations Regarding Pulsed Correction of Chromatic Aberrations in Final Focusing Systems

Nearly all designs of accelerators for heavy ion fusion rely on a velocity (energy) ramp to compress the beam longitudinally from its length in the accelerator to the length required at the target. The size of the velocity ramp is constrained by the longitudinal emittance of the beam. For example, if the longitudinal emittance is 0.05 eV {center_dot} s and we wish to produce a pulse having a width of {+-}2.5 ns at the target, we must supply an energy tilt such that the energy spread at the target is at least {+-}0.05 eV {center_dot} s/2.5 ns = {+-}2 x 10{sup 7} eV. The minimal value of energy spread occurs when the beam has propagated to the point where there is no correlation between the time and energy variables of the beam particles. (In the simple approximation where the boundary of the longitudinal phase space containing the particles is an ellipse, the ellipse is erect at this point, i.e., not tilted with respect to the axes.) In any case, the energy spread can affect focusing. If, for example, the beam kinetic energy is of the order of 5 GeV, a tilt of {+-}2 x 10{sup 7} eV corresponds to a fractional energy spread of 0.004 and it may be possible to focus the beam to the required spot size without using an achromatic optical system. Nevertheless, an optical system that allows larger longitudinal emittance should lead to a less expensive accelerator since the tolerances on acceleration waveforms could be relaxed. Moreover, at lower kinetic energies the problem becomes more serious. If the kinetic energy of our example beam were 1 GeV rather than 5 GeV, the fractional energy spread would be 0.02. This much energy spread would likely produce serious chromatic aberrations leading to an unwanted increase in focal spot size. It is interesting to note that the lower limit on energy spread at the target does not depend on whether the beam is neutralized as it approaches the target. If the beam is not neutralized, it will require a larger initial velocity tilt to overcome longitudinal space-charge forces; but these forces will remove part of the tilt as the beam compresses. Al Maschke suggested that it is possible to reduce the chromatic aberrations by applying a time-dependent transverse focusing correction to the beam upstream of the final focusing lenses [1]. At this point, because of the energy tilt, there is a correlation between longitudinal position in the beam and particle energy. In other words, the average beam energy at the tail of the beam is larger than the average beam energy at the head of the beam. If the beam is completely neutralized as it drifts toward the final focusing lenses, the kinetic energies of the individual particles will remain nearly unchanged during compression. In this case, it is possible, in principle, to apply some 'pre-focusing' to the higher energy particles (those nearer to the tail of the beam) to compensate for their weaker focusing in the final lenses. Although kinetic energies of individual particles are not conserved if the beam is not neutralized, one still expects a positive correlation between the particle energies at the beginning of compression and at the end of compression so correction is still assumed to be possible. It is important that the pulse duration is larger upstream than it is at the final focusing lenses. Larger pulse duration makes it easier, from an engineering standpoint, to supply the power needed to drive the pulsed correction elements. Nevertheless, it still appears impossible or very costly to provide the needed power for some specific cases that have been studied. In the remainder of this paper we ignore this issue and try to determine if there are other fundamental limitations on how well one might correct. We conclude that there are other important limitations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sizing of colloidal particle and protein molecules in a hanging fluid drop

We report non-invasive particle size measurements of polystyrene latex colloidal particles and bovine serum albumin (BSA) protein molecules suspended in tiny hanging fluid drops of 30 micro-Liter volume using a newly designed fiber optic probe. The probe is based upon the principles of the technique of dynamic light scattering (DLS). The motivation for this work comes from growing protein crystals in outer space. Protein crystals have been grown previously in hanging drops in microgravity experiments on-board the space shuttle orbiter. However, obtaining quantitative information on nucleation and growth of the protein crystals in real time has always been a desired goal, but hitherto not achieved. Several protein researchers have shown interest in using DLS to monitor crystal growth process in a droplet, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. We demonstrate that such an experiment is now possible. Our system offers fast (5 seconds) determination of particle size, utilize safe levels of very low laser power (less than or equal to 0.2 mW), a small scattering volume (approximately 2 x 10(exp -5) cu mm) and high spatial coherence (Beta) values. This is a major step forward when compared to currently available DLS systems.

Ansari, Rafat R.↗