Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrically”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Cummins Electric Truck with Range-Extending Engine (ETREE) Project (Final Technical Report)

The Cummins Electric Truck with Range Extending Engine (ETREE) program designed, developed, and demonstrated a range extending electric vehicle that employs an electrified propulsion system installed in a class 6 commercial vehicle (Peterbilt 220). This project was relevant to industry and the greater public because at the time of the project there were two keys to widespread electrified commercial vehicle adoption yet to be realize: 1) For pure electrified vehicle adoption, battery improvements are needed: Cost must decrease, and energy density must increase. 2) Electric vehicles must overcome fleet operator risks such as: operations in cold climates, hilly terrain, or where majority of conventional trucks are replaced with electrified vehicles. In the near to medium term these adoption hurdles were address by the objectives of this project. A plug-in hybrid vehicle that could be operated in all electric mode for most of its workday optimizing the use of grid energy with the ability to supplement energy demand with the onboard range extending engine. This project’s architecture provided ability to match a conventional class 6 commercial vehicle range and performance characteristics prior to the ubiquitous adoption of battery electric vehicle charging infrastructure as well. Additionally, the vehicles produced as part of this project can be considered a prototype for a commercially viable heavily electrified commercial vehicle because most of the physical hardware used for the project is commercially available in the market today. The ETREE program met its main objectives and demonstrated 65% fuel consumption reduction as compared to a conventional class 6 vehicle while meeting performance and range expectations. This was achieved by drawing upon the strengths of the assembled team: Cummins, PACCAR, the Ohio State University, Argonne National Laboratory and the National Renewable Energy Laboratory.

20 FOSSIL-FUELED POWER PLANTS↗

Sensitivity of Infrastructure Sectors to the Disruption of Commercial Electric Power

Electric power is crucial to the function of other infrastructures, as well as to the stability of the economy and the social order. Disruption of commercial electric power service, even for brief periods of time, can create significant consequences to the function of other sectors, and make living in some environments untenable. This analysis, conducted in 2017 for the United States Department of Energy (DOE) as part of the Grid Modernization Laboratory Consortium (GMLC) Initiative, focuses on describing the function of each of the other infrastructure sectors and subsectors, with an eye towards those elements of these sectors that depend on primary electric power service through the commercial electric power grid. It leverages the experience of Sandia analysts in analyzing historical disruptive events, and from the development of capabilities designed to identify the physical, logical, and geographic connectivity between infrastructures. The analysis goes on to identify alternatives for the provision of primary electric power service, and the redundancy of said alternatives, to provide a picture of the sector’s ability to withstand an extended disruption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feb. 2021 Electricity Blackouts and Natural Gas Shortages in Texas

An extreme winter storm and extended cold weather event hit Texas and the central United States February 8–19, 2021. This led to both exceptional energy demands and issues with electricity and natural gas supplies over several days. Residential space heating drove the increases in demand, with over 60% of Texas homes using electric heat pumps and 35% using natural gas furnaces. Supply issues were caused by freezing equipment and supply lines, impacting both natural gas supplies and most forms of electricity generation. [1] Natural gas supplies were especially important because natural gas also supplied about 50% of the electricity generating capacity in ERCOT, the primary grid operator in Texas. [2] Due to the supply shortages, wholesale electricity prices were forced to the ERCOT maximum of $\$9,000$ /MWh for over three days (recent range $\$20$–40/MWh), [3] and natural gas prices for physical delivery exceeded $\$400$ /MMBtu in some areas (recent range $\$3$–4/MMBtu). [4]

03 NATURAL GAS↗

Integrating Cambium Marginal Costs into Electric Sector Decisions: Opportunities to Integrate Cambium Marginal Cost Data into Berkeley Lab Analysis and Technical Assistance

NREL’s Cambium tool generates forward-looking simulations of marginal wholesale electricity costs associated with NREL’s Standard Scenarios. The scenarios include growing shares of variable renewable energy (VRE, i.e. wind and solar), among other power sector assumptions, between 2018 and 2050. The tool’s primary output—hourly costs at more than 130 balancing areas—could serve as public and transparent data source that supports electric-sector decision-making processes across the U.S. Berkeley Lab conducts a large range of analyses that use historical and forward-looking wholesale electricity prices to inform electric-sector decisions. In this report, Berkeley Lab uses its expertise to evaluate the Cambium cost data. We compare Cambium data with historical wholesale prices for the year 2018 and other modeled prices for the year 2030. We then present eight case studies in which Berkeley Lab researchers use Cambium data to replicate previous analyses based on other price datasets. We describe where primary findings and underlying key price dynamics align or differ, and highlight possible novel insights from the Cambium data. Finally, we qualitatively evaluate the suitability of Cambium costs in ten additional Berkeley Lab studies, though a direct comparison with alternative price data was not feasible at this time. The goal is to inform how electric-sector decision-makers and DOE program offices may be able to use this cohesive dataset, and to highlight what improvements to Cambium may make it even more useful.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Shielded and Low-Damping SPM Probes for Quantitative Electrical and Electrochemical Characterization (Phase IIA)

The purpose of this DOE SBIR award was to develop new scanning probe microscopy tools for the elucidation of electrical and electrochemical properties at the nanoscale. High performance probes are important for energy materials research. In both solar cells and batteries, the essential physics and chemistry occur at the nanoscale and nanoscale characterization tools are required for their elucidation. Two products were developed: an electrically shielded probe and an electrically conductive probe with low leakage currents. Our processes were based on post processing of existing probes and fabrication methods were tested, leading to a laser micromachining based approach that led to the first minimal viable product. We invented a method to make a reliable electrical contact that attaches a flexible printed circuit board to the chip. enable leak-free operation crucial when used in conductive liquids and electrolytes. This proprietary solution improves chip handling, reduces contamination, and maintains effective electrical contact. The probes fabricated in this Phase IIa are a minimal viable product which attracted attention from various tip manufacturers and instrument manufacturers alike.

36 MATERIALS SCIENCE↗

Understanding Your Utility Bills: Electricity

Electricity bills can often be difficult to decipher. Depending in the electricity provider, bills can be very long and detailed or extremely short, with only a few totals listed. Different charges can appear each month with no apparent explanation of how or why they are calculated. Learning how to read electricity bills and understand why different charges are assessed is key to maximizing cost savings through energy efficiency. This document provides guidance on the basics of understanding electricity bills and covers electricity generation, rate structures, usage trends, and savings opportunities. The information in this guide can be used to help companies collect and report their energy efficiency improvements to the DOE Better Plants Program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

100% Carbon-Free Electricity for Sandia NM and KAFB Using Concentrating Solar Power (CSP) (SAND Report)

This report provides a design study to produce 100% carbon-free electricity for Sandia NM and Kirtland Air Force Base (KAFB) using concentrating solar power (CSP). Annual electricity requirements for both Sandia and KAFB are presented, along with specific load centers that consume a significant and continuous amount of energy. CSP plant designs of 50 MW and 100 MW are then discussed to meet the needs of Sandia NM and the combined electrical needs of both Sandia NM and KAFB. Probabilistic modeling is performed to evaluate inherent uncertainties in performance and cost parameters on total construction costs and the levelized cost of electricity. Total overnight construction costs are expected to range between ~$300M - $400M for the 50 MW CSP plant and between ~$500M - $800M for the 100 MW plant. Annual operations and maintenance (O&M) costs are estimated together with potential offsets in electrical costs and CO 2 emissions. Other considerations such as interconnections, land use and permitting, funding options, and potential agreements and partnerships with Public Service Company of New Mexico (PNM), Western Area Power Administration (WAPA), and other entities are also discussed.

14 SOLAR ENERGY↗

Effect of wheel speed on the magnetic and mechanical properties of melt spun Fe-6.5 wt.% electric steel

Fe-Si electric steel is the most widely used soft magnetic materials in electric mahines and motors, transformers and generators. Improving the surperior magnetic and electric properties of 6.5 wt.% high silicon steel is essential for higher may improve energy efficiency and power density of electric machines. However, the brittleness due to the formation of B2 and D03 ordered phases in high silicon steel make it difficult forbids for the application of high silicon steel. It is known that these ordered phases can be fully or partially suppressed by rapid cooling. However, further study is needed to understand the extend of cooling on the magnetic and mechanical properties of 6.5 wt.% silicon steel with various degree of ordering. By tuning the wheel speed from 1m/s to 30m/s with several intervals of the melt spinning process, varying degrees of cooling were achieved on 6.5 wt.% silicon steel ribbons. The cooling rate significant altered the ordering, microstructure size scale, and thus the mechanical and magnetic properties. TEM results showed that D03 ordering can be fully suppressed at high wheel speed, but started to nucleate at 5m/s and below, which correlates with the hardness and Young’s modulus increase towards low wheel speeds as tested by micro and nano indentation. The grain sizes of the ribbons on the wheel side decreased with increasing wheel speeds being ~100 micron at 1m/s and ~8 micron at 30m/s, which led to the change in coercivity. Saturation magnetization and electric resistivity of the ribbons remained about 190 emu/g and 84 microhm *cm, which appeared to be mainly depend on the chemistry.

Fe-6.5%Si Steel↗

Electric Drive Technologies Research: Bottom-Up Soft Magnetic Composites (FY2022 Annual Progress Report)

In order to meet 2025 goals for enhanced peak power (100 kW), specific power (50 kW/L), and reduced cost (3.3 $\$$/kW) in a motor that can operate at ≥ 20,000 rpm, improved soft magnetic materials must be developed. Better performing soft magnetic materials will also enable rare earth free electric motors. In fact, replacement of permanent magnets with soft magnetic materials was highlighted in the Electrical and Electronics Technical Team (EETT) Roadmap as a R&D pathway for meeting 2025 targets. Eddy current losses in conventional soft magnetic materials, such as silicon steel, begin to significantly impact motor efficiency as rotational speed increases. Soft magnetic composites (SMCs), which combine magnetic particles with an insulating matrix to boost electrical resistivity (ρ) and decrease eddy current losses, even at higher operating frequencies (or rotational speeds), are an attractive solution. Today, SMCs are being fabricated with values of ρ ranging between 10 -3 to 10 -1 μohm∙m, which is significantly higher than 3% silicon steel (~0.05 μohm∙m). The isotropic nature of SMCs is ideally suited for motors with 3D flux paths, such as axial flux motors. Additionally, the manufacturing cost of SMCs is low and they are highly amenable to advanced manufacturing and net-shaping into complex geometries, which further reduces manufacturing costs. There is still significant room for advancement in SMCs, and therefore additional improvements in electrical machine performance. For example, despite the inclusion of a non-magnetic insulating material, the electrical resistivities of SMCs are still far below that of soft ferrites (10 – 10 8 μohm∙m).

33 ADVANCED PROPULSION SYSTEMS↗

A Review of Water and Climate Change Analysis in Electric Utility Integrated Resource Planning

The purpose of this paper is to examine the extent to which electric utility integrated resource plans (IRPs) evaluate the impact of water constraints on electric generation resource portfolios and the extent to which IRPs consider the impacts of climate change to generation and loads. This white paper reviewed 30 IRPs to determine best practices with respect to analyzing and reporting on potential water-based and climate change risks within the integrated resource planning process. Best practices from electric utility IRPs are identified and additional recommendations and considerations are put forth. In recent years, thermal generating facilities have experienced challenges with water availability: a shortage of cooling water, conditions in which incoming cooling water is too warm for optimal operation, and/or water discharge temperatures exceeding permit limits. S&P Global Market Intelligence recently reported on a study that identified for the year 2030, 98.2 gigawatts (GW) of coal capacity at risk due to water stress. Climate change effects on hydrological cycles may adjust the timing, temperature, and volume of water availability for thermal electric cooling and for hydropower generation, which could further exacerbate the frequency and duration of operational constraints. Climate change can also impact the timing and intensity of electric loads that utilities must serve, most notably for heating and cooling.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dielectrics Under Extreme Electric Fields: In Situ Studies on Nanoscale Mechanisms (Final Technical Report)

The lack of materials that can function reliably under extreme electric fields is a critical roadblock to achieving higher energy efficiency and extended service lifetime of devices in electricity generation, transmission, and consumption. Materials typically fail at two or three orders of magnitude below their theoretical dielectric breakdown strength. Identifying the origins of premature dielectric breakdown using state-of-the-art characterization tools will, therefore, enable the design and discovery of transformational materials capable of approaching their intrinsic limits. The vast improvement in the resolution power of imaging tools, combined with the recently developed in situ electric biasing technique, has made high resolution observations of dielectric breakdown as it happens possible. The overall goal of the project is to directly image the dynamic processes of defect formation, accumulation, and interaction with preexisting defects (e.g., dislocations, domain walls, and grain boundaries in crystalline dielectric films) under electric fields up to 1,000 MV/m with a temporal resolution better than 5 microseconds. Using the newly acquired, custom-made Hysitron PI95 transmission electron microscopy (TEM) specimen holder, in situ TEM observations of breakdown at the sub nanometer resolution will be made on representative dielectric compounds with progressive complexities: the linear dielectric SiO 2 , CuO, and TiO 2 , the ferroelectric BaTiO 3 nanocrystals and nanocubes. Through direct observation of the breakdown event at high spatial and temporal resolutions, the nanoscale mechanisms for the failure of dielectrics under intense electric fields will be identified. The results of the project will be applied to the design and processing of new dielectric materials with higher efficiency, improved reliability, and a prolonged lifetime. Such new dielectrics are urgently needed for modernizing energy infrastructures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical Resistivity Tomography of the 216-U-5 and 216-U-6 WA-1 Waste Sites

The subsurface below the 216-U-5 and 216-U-6 sites needs to be characterized as part of the remedial investigation of the 200-WA-1 operable unit at the Hanford Site. Electrical resistivity tomography (ERT) was selected as a first step in this characterization effort to provide information about the three-dimensional distribution of historically disposed waste fluids in the subsurface beneath these sites. ERT does not directly image specific contaminants. However, ERT provides a three-dimensional image of subsurface zones where the bulk electrical conductivity is higher than surrounding background values. Disposed waste fluids can increase the bulk electrical conductivity in the subsurface where they are present by increasing the moisture content and because the high concentration of waste-fluid constituents such as nitrate cause the fluid to have a higher specific conductance than background pore water. Thus, zones of increased bulk electrical conductivity in the subsurface can be interpreted as zones where waste fluids are present. An ERT survey of the subsurface beneath the 216-U-5 and 216-U-6 sites was conducted to collect ERT data suitable for interpreting the bulk electrical conductivity distribution in the subsurface. Data interpretation was applied using the NQA-1 qualified E4D ERT parallel modelling and inversion code (Johnson 2014). A summary cross-section and interpretation of the 216-U-5 and 216-U-6 ERT is provided in Figure S.1. The ERT image reveals two distinct zones of anomalous bulk conductivity emanating from 216-U-5 and 216-U-6 that merge at a depth of approximately 14 m below the surface and continue to a depth of no more than 26 m below the surface, which is approximately 60 m above the current water table elevation. The image also suggests that lateral transport of waste streams disposed into 216-U-5 and 216-U-6 was limited. These results are consistent with historical groundwater monitoring, which indicated that the disposed waste had not migrated to the water table, possibly due to the relatively low volumes of waste discharge into 216-U-5 and 216-U-6. The ERT information provides a line of evidence supporting this conclusion and can be used to guide the selection of characterization borehole(s) location and depth as needed for additional characterization of the contaminant distribution and properties at these sites. Locations of bulk conductivity anomalies associated with 216-U-5 and 216-U-6 releases are offset approximately 10 m to the west of the locations of 216-U-5 and 216-U-6 as recorded in the Waste Information Data System database. There are two predominant regions of elevated bulk conductivity in addition to those associated with 216-U-5 and 216-U-6. The first is located beneath Beloit Ave. from approximately 190 to 195 m in elevation. The small region of high conductivity directly beneath Beloit Ave. is likely an artifact resulting from the failure to account for the Beloit Ave. topographic rise in the ERT modeling, as that information was unavailable. Information concerning the precise positioning of the railroad tracks shown was also unavailable, particularly in the vertical dimension. The high conductivity anomaly beneath the assumed railroad track location is likely caused by misplacement of the tracks in the ERT model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adoption of Plug-in Electric Vehicles: Local Fuel Use and Greenhouse Gas Emissions Reductions Across the U.S.

The dependence on gasoline-powered light-duty automobiles has made U.S. households vulnerable to the burden of fuel costs. Tailpipe emissions from these vehicles constitute 58% of greenhouse gas (GHG) emissions in the U.S., which are damaging to the environment (EPA, 2023). The adoption of plug-in electric vehicles (PEVs) has been shown to effectively reduce fuel costs and GHG emissions. However, local effects on these benefits are not well understood by American consumers, potentially limiting adoption and therefore the realization of PEV benefits at scale (MacInnis & Krosnick, 2020; EY Americas, 2023). To fill this research gap, this study estimates the fuel cost savings and GHG emission reductions at the state and ZIP code levels by considering local fuel prices, vehicle class preference, average vehicle model year, fuel efficiencies, and driving intensities. The study's findings reveal that the adoption of PEVs can yield substantial benefits in terms of fuel cost savings and GHG emission reductions nationwide. Specifically, driving a battery electric vehicle (BEV) is estimated to result in annual savings of up to $\$2,200$, while driving a plug-in hybrid electric vehicle (PHEV) can lead to savings up to $\$1,500$, when compared to an internal combustion engine vehicle (ICEV) of equivalent size. Moreover, using population-weighted averages by ZIP code, BEVs and PHEVs show the potential to save 400 and 200 grams of carbon dioxide equivalent per mile, respectively, compared to a representative ICEV of the same class. The magnitude of fuel cost savings and emissions reduction vary by region due to various factors. Generally, regions with high gasoline prices, low electricity prices, preferences for larger vehicles, and high driving intensities tend to see relatively large fuel savings. The emissions reductions are more pronounced in areas with clean grids where consumer preferences lie with large vehicles. This regional variability underscores the importance of considering local contextual factors when assessing the potential benefits of PEV adoption. In more than 99% of U.S. ZIP codes, PEVs result in overall savings in fuel use (and subsequent costs) and GHG emissions. While not a central focus of this analysis, reductions in GHG tailpipe emissions from PEV adoption would also come with reductions in criteria pollutant emissions, contributing to improved local air quality depending on the PEV penetration, population density, and electricity generation infrastructure in the locality.

33 ADVANCED PROPULSION SYSTEMS↗

Survey on Efficient and Productive Use of Electricity In Women-Run Small Businesses in Uganda

In Uganda, women make up a large portion of the service sector, notably in informal small and micro businesses such as retail shops, food preparation, tailoring, sewing, beer brewing, basket weaving, healthcare, and hairdressing. Lawrence Berkeley National Laboratory (LBNL), and USAID, in partnership with the Clean Energy Enthusiasts (CEE), a local implementer in Uganda, designed and conducted a participatory survey to collect baseline data and information on the current state of benefits to energy access. The study included data on the uptake of efficient and productive electric (EPUE) equipment, business skills, and financial needs among small and mid-size women-led businesses in Uganda. The objective of the survey was to build evidence and identify economic activities where access to electricity has a positive impact on women’s empowerment by helping them develop new and existing businesses, improve productivity, and increase their income. The survey included questions about the type of electric equipment used and needed, electric consumption patterns, alternative sources to electricity, and business and capital barriers related to increased access. The survey results provided the basis for designing a training program tailored to the need of women entrepreneurs in the region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling of the Electricity and Transportation Sectors - Part II: Risk Assessment

This comprehensive report explores the intricate interplay through “sector coupling” between the Transportation Sector, Energy Sector, and the critical infrastructure challenges faced by the United States. Aligned with the ambitious federal goal of reducing greenhouse gas emissions, the report analyzes the present vulnerabilities in the fossil fuel supply chain, highlighting instances where the dependence on this industry has been susceptible to local and global disruptions. With a focus on risk assessment, this report establishes a framework to compare the fossil fuel-based transportation sector with the burgeoning electrified sector, considering the evolving technologies in electric vehicles (EVs) and the nascent charging infrastructure. This study delves into the historical reliability of fossil fuel-based transportation and identifies opportunities for strengthening sector coupling between transportation and the electric sector. Assessments of the gasoline-diesel supply chain provide insights into both opportunities and threats, offering a roadmap for creating a more reliable and resilient electrified transportation system. We modeled sectoral coupling scenarios for the current internal combustion engine (ICE)-based and future EV-dominant landscapes, leveraging qualitative sector attributes to identify relative strengths and weaknesses in Part 1 of the report. In this report (Part 2) we continue to understand the role of the electricity sector on transportation and develop a semi-quantitative methodology is employed to evaluate and compare the risks associated with the fossil fueled and electric transportation sector during emergency scenarios, drawing from real-world events like hurricanes and geopolitical disruptions. Different operational scenarios for the fossil fuel and electrified sectors have been developed to understand the risks associated with them. This report concludes with recommendations for the architectural designs of electric charging infrastructure, underlining the need for informed decisions in the transition towards a sustainable and resilient transportation future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Efficiency of Off-Road Vehicles by Novel Integration of Electric Machines and Advanced Combustion Engines

Modern off-road equipment will increasingly rely on electrified implements that will deliver precision control with a smaller footprint than hydraulics. The primary energy converter, however, will be an onboard reciprocating internal combustion engine because of the power density of hydrocarbon fuels in comparison to electrical energy storage and the remote locations where much of this equipment is deployed. Adding energy storage and electric machines creates opportunities to improve efficiency while reducing emissions. This program investigated approaches to take advantage of the extra flexibility that an enhanced electrical system to enable high-efficiency, low-emissions combustion technologies. The current program evaluated hybridization of both the torque application and air-handling systems to maximize efficiency while minimizing cost. This program designed, analyzed and tested a hybrid off-road vehicle consisting of a series electric powertrain with energy storage, an electrified air system, and a 33% downsized diesel engine. Detailed comparisons were made between the base powertrain and the developed powertrain using powertrain simulations, engine testing, and vehicle testing. The key results of the study are: • The resulting vehicle reduces fuel consumption by 5% to 15% at equal productivity. The primary improvements were due to recovery of regenerative braking losses for cycles where large transients are encountered. • The electrified air system was an enabler to allow engine downsizing. This was most important for duty-cycles where the engine primarily operated at moderate loads and had few low speed high torque conditions. • Engine level improvements showed re-optimization of the powertrain is possible when electrified air handing is available. Increased exhaust gas recirculation and advanced injection timing allowed up to a 15% reduction in brake specific fuel consumption at equal NOx and transient response. Compared to the larger engine, the downsized engine achieves up to an 18% reduction in brake specific fuel consumption over the non-road transient cycle. • The life cycle analysis and total cost of ownership study showed that the hybrid powertrain has the potential to reduce 5-year CO2 and total cost of ownership by ~6% over the baseline vehicle. The results also indicated that a pure battery electric vehicle is not feasible in this application and is likely to increase the CO2 emissions due to the CO2 from battery production. A hybrid powertrain with low carbon fuels shows the potential to substantially reduce CO2 and total cost of ownership.

02 PETROLEUM↗

Quantifying Socioeconomic Impacts of Electricity Generating Technologies

The levelized cost of energy (LCOE) and other cost metrics used in energy planning do not account for out-of-market impacts of the technology choice. While a decision-maker at the utility or asset owner level may compare multiple forms of electricity generating technology using LCOE, a decision-maker over energy policy or community stakeholders may be interested in considering impacts beyond those that LCOE measures. This report quantifies economic impacts such as jobs and wage growth across electricity generation technologies then develops an approach to systematically compare socioeconomic metrics across technology choices. To address additional workforce related impacts, this report also compares the typical workforce education requirements and annual income levels for multiple types of electricity generating facilities. The grid scale electricity generating technologies analyzed in this report produce power using conventional hydroelectric dams, coal, natural gas, nuclear reactors, solar PV, land-based wind turbines, geothermal heat, and woody biomass combustion. Although it doesn’t generate electricity itself, the economic impacts associated with battery storage equipment manufacturing and installation were also analyzed.

03 NATURAL GAS↗