Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

Critical review of the Mogi failure criterion based on true-triaxial laboratory data analysis and theoretical considerations

The influence of the intermediate principal stress, σ 2 , is disregarded when rock strength is analyzed using the Mohr-Coulomb or Hoek-Brown criteria. Several polyaxial strength criteria have been proposed to account for the influence of σ 2 . One of the methods that received considerable attention is the Mogi criterion. The criterion modifies the Nadai or Drucker-Prager approaches by exchanging the normal octahedral stress with what is introduced as the mean effective stress, σ m,2 . This change is based on experimental evidence that the influence of the intermediate principal stress on strength is less pronounced than the influence of the minimum principal stress. However, the Mogi criterion was derived somewhat empirically and consequently it is essential to analyze its potential theoretical deficiencies. In the current note, we analyzed the Mogi failure criterion, describing its characteristics in both τ oct –σ m,2 and σ 1 -σ 2 spaces. We investigated the relation between Mohr-Coulomb and Mogi criteria, which marks the basis for the commonly used Mogi-Coulomb approach. Here, we compared the performance of the Mogi criterion against available polyaxial strength data using three fitting approaches: Mogi-Coulomb based on triaxial compression results only, linear Mogi based on all polyaxial strength results, and power law Mogi also based on all data. The analysis reveals several serious deficiencies of the Mogi approach which all suggest that the Mogi criterion cannot properly represent the σ 2 dependence of rock strength in many cases.

58 GEOSCIENCES↗

Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 2 continues the presentation of IOA worksheets.

Prust, Chet D.↗

Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 3

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 3 continues the presentation of IOA worksheets.

Prust, Chet D.↗

Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 4

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 4 continues the presentation of IOA worksheets and contains the potential critical items list.

Prust, Chet D.↗

Space Shuttle Main Engine Quantitative Risk Assessment: Illustrating Modeling of a Complex System with a New QRA Software Package

During 1997, a team from Hernandez Engineering, MSFC, Rocketdyne, Thiokol, Pratt & Whitney, and USBI completed the first phase of a two year Quantitative Risk Assessment (QRA) of the Space Shuttle. The models for the Shuttle systems were entered and analyzed by a new QRA software package. This system, termed the Quantitative Risk Assessment System(QRAS), was designed by NASA and programmed by the University of Maryland. The software is a groundbreaking PC-based risk assessment package that allows the user to model complex systems in a hierarchical fashion. Features of the software include the ability to easily select quantifications of failure modes, draw Event Sequence Diagrams(ESDs) interactively, perform uncertainty and sensitivity analysis, and document the modeling. This paper illustrates both the approach used in modeling and the particular features of the software package. The software is general and can be used in a QRA of any complex engineered system. The author is the project lead for the modeling of the Space Shuttle Main Engines (SSMEs), and this paper focuses on the modeling completed for the SSMEs during 1997. In particular, the groundrules for the study, the databases used, the way in which ESDs were used to model catastrophic failure of the SSMES, the methods used to quantify the failure rates, and how QRAS was used in the modeling effort are discussed. Groundrules were necessary to limit the scope of such a complex study, especially with regard to a liquid rocket engine such as the SSME, which can be shut down after ignition either on the pad or in flight. The SSME was divided into its constituent components and subsystems. These were ranked on the basis of the possibility of being upgraded and risk of catastrophic failure. Once this was done the Shuttle program Hazard Analysis and Failure Modes and Effects Analysis (FMEA) were used to create a list of potential failure modes to be modeled. The groundrules and other criteria were used to screen out the many failure modes that did not contribute significantly to the catastrophic risk. The Hazard Analysis and FMEA for the SSME were also used to build ESDs that show the chain of events leading from the failure mode occurence to one of the following end states: catastrophic failure, engine shutdown, or siccessful operation( successful with respect to the failure mode under consideration).

Smart, Christian↗

Evaluation of a Compression-Loaded-Stitched-Multi-Bay Fuselage Panel With Barely Visible Impact Damage

The experimental results from a stitched VaRTM carbon-epoxy composite panel tested under uni-axial compression loading are presented along with nonlinear finite element analysis prediction of the response. The curved panel is divided by frames and stringers into six bays with a column of three bays along the compressive loading direction. The frames are supported at the frame ends to resist out-of-plane translation. Back-to-back strain gages are used to record the strain and displacement transducers were used to record the out-of-plane displacements. In addition a full-field-displacement measurement technique that utilizes a camera-based-stereo-vision system was used to record the displacements. The panel was loaded to 1.5 times the predicted initial buckling load (1st bay buckling load, P(sub er) from the nonlinear finite element analysis and then was removed from the test machine for impact testing. After impacting with 20 ft-lbs of energy using a spherical impactor to produce barely visible damage the panel was loaded in compression until failure. The buckling load of the first bay to buckle was 97% of the buckling load before impact. The stitching constrained the impact damage from growing during the loading to failure. Impact damage had very little overall effect on panel stiffness. Panel stiffness measured by the full-field-displacement technique indicated a 13% loss in stiffness after impact. The panel failed at 1.64 times the first panel buckling load. The barely visible impact damage did not grow noticeably as the panel failed by global instability due to stringer-web terminations at the frame locations. The predictions from the nonlinear analysis of the finite element modeling of the entire specimen were very effective in the capture of the initial buckling and global behavior of the panel. In addition, the prediction highlighted the weakness of the panel under compression due to stringer web terminations. Both the test results and the nonlinear predictions serve to reinforce the severe penalty in structural integrity caused by the low cost manufacturing technique to terminate the stringer webs, and demonstrates the importance of this type of sub-component testing and high fidelity failure analysis in the design of a composite fuselage.

Baker, Donald J.↗

Finite element based micro-mechanics modeling of textile composites

Textile composites have the advantage over laminated composites of a significantly greater damage tolerance and resistance to delamination. Currently, a disadvantage of textile composites is the inability to examine the details of the internal response of these materials under load. Traditional approaches to the study fo textile based composite materials neglect many of the geometric details that affect the performance of the material. The present three dimensional analysis, based on the representative volume element (RVE) of a plain weave, allows prediction of the internal details of displacement, strain, stress, and failure quantities. Through this analysis, the effect of geometric and material parameters on the aforementioned quantities are studied.

Glaessgen, E. H.↗

Fretting Stresses in Single Crystal Superalloy Turbine Blade Attachments

Single crystal nickel base superalloy turbine blades are being utilized in rocket engine turbopumps and turbine engines because of their superior creep, stress rupture, melt resistance and thermomechanical fatigue capabilities over polycrystalline alloys. Currently the most widely used single crystal nickel base turbine blade superalloys are PWA 1480/1493 and PWA 1484. These alloys play an important role in commercial, military and space propulsion systems. High Cycle Fatigue (HCF) induced failures in aircraft gas turbine and rocket engine turbopump blades is a pervasive problem. Blade attachment regions are prone to fretting fatigue failures. Single crystal nickel base superalloy turbine blades are especially prone to fretting damage because the subsurface shear stresses induced by fretting action at the attachment regions can result in crystallographic initiation and crack growth along octahedral planes. Furthermore, crystallographic crack growth on octahedral planes under fretting induced mixed mode loading can be an order of magnitude faster than under pure mode I loading. This paper presents contact stress evaluation in the attachment region for single crystal turbine blades used in the NASA alternate Advanced High Pressure Fuel Turbo Pump (HPFTP/AT) for the Space Shuttle Main Engine (SSME). Single crystal materials have highly orthotropic properties making the position of the crystal lattice relative to the part geometry a significant factor in the overall analysis. Blades and the attachment region are modeled using a large-scale 3D finite element (FE) model capable of accounting for contact friction, material orthotrophy, and variation in primary and secondary crystal orientation. Contact stress analysis in the blade attachment regions is presented as a function of coefficient of friction and primary and secondary crystal orientation, Stress results are used to discuss fretting fatigue failure analysis of SSME blades. Attachment stresses are seen to reach peak values at locations where fretting cracks have been observed. Fretting stresses at the attachment region are seen to vary significantly as a function of crystal orientation. Attempts to adapt techniques used for estimating fatigue life in the airfoil region, for life calculations in the attachment region, are presented. An effective model for predicting crystallographic crack initiation under mixed mode loading is required for life prediction under fretting action.

Arakere, Nagaraj K.↗

Model 0A wind turbine generator FMEA

The results of Failure Modes and Effects Analysis (FMEA) conducted for the Wind Turbine Generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems which are also reflected in this FMEA.

Klein, William E.↗

The importance of retaining a phylogenetic perspective in traits-based community analyses

1) Many environmental stressors manifest their effects via physiological processes (traits) that can differ significantly among species and species groups. We compiled available data for three traits related to the bioconcentration of the toxic metal cadmium (Cd) from 42 aquatic insect species representing orders Ephemeroptera (mayfly), Plecoptera (stonefly), and Trichoptera (caddisfly). These traits included the propensity to take up Cd from water (uptake rate constant, ku), the ability to excrete Cd (efflux rate constant, ke), and the net result of these two processes (bioconcentration factor, BCF). 2) Ranges in these Cd bioaccumulation traits varied in magnitude across lineages (some lineages had a greater tendency to bioaccumulate Cd than others). Overlap in the ranges of trait values among different lineages was common and highlights situations where species from different lineages can share a similar trait state, but represent the high end of possible physiological values for one lineage and the low end for another. 3) Variance around the mean trait state differed widely across clades, suggesting that some groups (e.g., Ephemerellidae) are inherently more variable than others (e.g., Perlidae). Thus, trait variability/lability is at least partially a function of lineage. 4) Akaike information criterion (AIC) comparisons of statistical models were more often driven by clade than by other potential biological or ecological explanation tested. Clade-driven models generally improved with increasing taxonomic resolution. 5) Altogether, these findings suggest that lineage provides context for the analysis of species traits, and that failure to consider lineage in community-based analysis of traits may obscure important patterns of species responses to environmental change.

59 BASIC BIOLOGICAL SCIENCES↗

A study of discrete control signal fault conditions in the shuttle DPS

An analysis of the effects of discrete failures on the data processing subsystem is presented. A functional description of each discrete together with a list of software modules that use this discrete are included. A qualitative description of the consequences that may ensue due to discrete failures is given followed by a probabilistic reliability analysis of the data processing subsystem. Based on the investigation conducted, recommendations were made to improve the reliability of the subsystem.

Reddi, S. S.↗

An overview of the mathematical and statistical analysis component of RICIS

Mathematical and statistical analysis components of RICIS (Research Institute for Computing and Information Systems) can be used in the following problem areas: (1) quantification and measurement of software reliability; (2) assessment of changes in software reliability over time (reliability growth); (3) analysis of software-failure data; and (4) decision logic for whether to continue or stop testing software. Other areas of interest to NASA/JSC where mathematical and statistical analysis can be successfully employed include: math modeling of physical systems, simulation, statistical data reduction, evaluation methods, optimization, algorithm development, and mathematical methods in signal processing.

Hallum, Cecil R.↗

Model authoring system for fail safe analysis

The Model Authoring System is a prototype software application for generating fault tree analyses and failure mode and effects analyses for circuit designs. Utilizing established artificial intelligence and expert system techniques, the circuits are modeled as a frame-based knowledge base in an expert system shell, which allows the use of object oriented programming and an inference engine. The behavior of the circuit is then captured through IF-THEN rules, which then are searched to generate either a graphical fault tree analysis or failure modes and effects analysis. Sophisticated authoring techniques allow the circuit to be easily modeled, permit its behavior to be quickly defined, and provide abstraction features to deal with complexity.

Sikora, Scott E.↗

Graded approach for assessing digital system failure susceptibilities - 305

Owner/operators of nuclear plants must be able to identify and assess susceptibilities to digital system failures and unintended behaviors that could lead to plant system malfunctions, including common-cause failures (CCFs) of multiple controlled components that may impact overall plant safety. Nuclear plant designers and regulators often assess and manage potential failure modes by assuming the failure occurs and showing by analysis that the results are acceptable. In 2016 EPRI published a guideline on Methods for Assuring Safety and Dependability when Applying Digital Instrumentation and Control Systems (EPRI 3002005326), which takes a more holistic approach that considers digital system failure modes from the perspective of their impact on plant risk and includes a graded approach based on safety significance. This paper describes that graded approach. The methodology in EPRI 3002005326 systematically identifies potential I and C vulnerabilities that could lead to significant malfunctions of controlled components and systems, including common-cause failures (CCF), and discusses in detail methods to protect against them. It considers both preventive measures that reduce the likelihood of failures, and plant systems and features that mitigate the effects of component failures and misbehaviors. Coping analysis is then performed as appropriate to provide additional assurance of protection. The safety significance based graded approach is an important feature in that it can help users focus attention on overall plant safety, including potentially risk-significant scenarios that might not be considered in traditional safety analyses. The purpose is to help the user ensure that modifications to the I and C that could potentially be safety significant are treated appropriately and at the same time not waste valuable resources on excessive protection against changes that have little or no impact on safety. The graded approach allows the design engineer to tailor the rigor of the preventive, limiting, and mitigative measures commensurately with the effects the I and C modification has on overall plant safety. The graded approach focuses on safety significance impact, which is effectively a qualitative measure of the potential change in safety (or risk) caused by a proposed I and C modification, as compared to the I and C that is being replaced. Safety significance impact should not be confused with importance to safety or risk significance. It is possible that an upgrade to safety-related and/or risk-significant I and C systems may have little or no safety significant impact and vice versa. The approach considers three factors that influence the impact on safety significance of a proposed I and C modification: context, likelihood of failure, and consequences of failure. The most significant of the three factors is context - what the I and C is connected to, both directly and indirectly, including its potential effects on plant systems that respond to transients or accidents. The graded approach is particularly helpful in assessing potential CCFs resulting from digital I and C failures, and shows why the most problematic CCFs will be those that can affect multiple plant systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design/Analysis of the JWST ISIM Bonded Joints for Survivability at Cryogenic Temperatures

A major design and analysis challenge for the JWST ISIM structure is thermal survivability of metal/composite bonded joints below the cryogenic temperature of 30K (-405 F). Current bonded joint concepts include internal invar plug fittings, external saddle titanium/invar fittings and composite gusset/clip joints all bonded to M55J/954-6 and T300/954-6 hybrid composite tubes (75mm square). Analytical experience and design work done on metal/composite bonded joints at temperatures below that of liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are sparse in the literature. Increasing this challenge is the difficulty in testing for these required tools and properties at cryogenic temperatures. To gain confidence in analyzing and designing the ISIM joints, a comprehensive joint development test program has been planned and is currently running. The test program is designed to produce required analytical tools and develop a composite failure criterion for bonded joint strengths at cryogenic temperatures. Finite element analysis is used to design simple test coupons that simulate anticipated stress states in the flight joints; subsequently the test results are used to correlate the analysis technique for the final design of the bonded joints. In this work, we present an overview of the analysis and test methodology, current results, and working joint designs based on developed techniques and properties.

Bartoszyk, Andrew↗

Task Analysis Technologies at KSC

Project objective: (1) Form an integrated team of NASA. USA, Boeing, and Dynacs researches. (2) Create a user friendly software prototype that assists an analyst in performing a human factors process failure modes and effects analysis (HF-PFMEA). (3)Perform four task analyses on center: cargo late access task analysis (NASA/Boeing team); payload test and verification system task analysis (NASA/Boeing team); slammer cover installation operations task analysis (NASA/USA team); ATDC LOX pump acceptance test procedure task analysis (NASA/Dynacs team).

Carstens, Deborah S.↗

Multicenter Analysis of Effect of High Biologic Effective Dose on Biochemical Failure and Survival Outcomes in Patients With Gleason Score 7-10 Prostate Cancer Treated With Permanent Prostate Brachytherapy

Purpose: To investigate the biochemical control rates and survival for Gleason score 7-10 prostate cancer patients undergoing permanent prostate brachytherapy as a function of the biologic effective dose (BED). Methods and Materials: Six centers provided data on 5,889 permanent prostate brachytherapy patients, of whom 1,078 had Gleason score 7 (n = 845) or Gleason score 8-10 (n = 233) prostate cancer and postimplant dosimetry results available. The median prostate-specific antigen level was 7.5 ng/mL (range, 0.4-300). The median follow-up for censored patients was 46 months (range, 5-130). Short-term hormonal therapy (median duration, 3.9 months) was used in 666 patients (61.8%) and supplemental external beam radiotherapy (EBRT) in 620 (57.5%). The patients were stratified into three BED groups: <200 Gy (n = 645), 200-220 Gy (n = 199), and >220 Gy (n = 234). Biochemical freedom from failure (bFFF) was determined using the Phoenix definition. Results: The 5-year bFFF rate was 80%. The bFFF rate stratified by the three BED groups was 76.4%, 83.5%, and 88.3% (p < 0.001), respectively. Cox regression analysis revealed Gleason score, prostate-specific antigen level, use of hormonal therapy, EBRT, and BED were associated with bFFF (p < 0.001). Freedom from metastasis improved from 92% to 99% with the greatest doses. The overall survival rate at 5 years for the three BED groups for Gleason score 8-10 cancer was 86.6%, 89.4%, and 94.6%, respectively (p = 0.048). Conclusion: These data suggest that permanent prostate brachytherapy combined with EBRT and hormonal therapy yields excellent bFFF and survival results in Gleason score 7-10 patients when the delivered BEDs are >220 Gy. These doses can be achieved by a combination of 45-Gy EBRT with a minimal dose received by 90% of the target volume of 120 Gy of {sup 103}Pd or 130 Gy of {sup 125}I.

62 RADIOLOGY AND NUCLEAR MEDICINE↗