Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Radiometric Characterization of IKONOS Multispectral Imagery

A radiometric characterization of Space Imaging's IKONOS 4-m multispectral imagery has been performed by a NASA funded team from the John C. Stennis Space Center (SSC), the University of Arizona Remote Sensing Group (UARSG), and South Dakota State University (SDSU). Both intrinsic radiometry and the effects of Space Imaging processing on radiometry were investigated. Relative radiometry was examined with uniform Antarctic and Saharan sites. Absolute radiometric calibration was performed using reflectance-based vicarious calibration methods on several uniform sites imaged by IKONOS, coincident with ground-based surface and atmospheric measurements. Ground-based data and the IKONOS spectral response function served as input to radiative transfer codes to generate a Top-of-Atmosphere radiance estimate. Calibration coefficients derived from each vicarious calibration were combined to generate an IKONOS radiometric gain coefficient for each multispectral band assuming a linear response over the full dynamic range of the instrument. These calibration coefficients were made available to Space Imaging, which subsequently adopted them by updating its initial set of calibration coefficients. IKONOS imagery procured through the NASA Scientific Data Purchase program is processed with or without a Modulation Transfer Function Compensation kernel. The radiometric effects of this kernel on various scene types was also investigated. All imagery characterized was procured through the NASA Scientific Data Purchase program.

Pagnutti, Mary↗

SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity differences between primary and lymphoma tumor by multi-scale image texture analysis. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterisation of a MeV Bremsstrahlung x-ray source produced from a high intensity laser for high areal density object radiography

Results of an experiment to characterise a MeV Bremsstrahlung x-ray emission created by a short (<10 ps) pulse, high intensity (1.4 × 10{sup 19} W/cm{sup 2}) laser are presented. X-ray emission is characterized using several diagnostics; nuclear activation measurements, a calibrated hard x-ray spectrometer, and dosimeters. Results from the reconstructed x-ray energy spectra are consistent with numerical simulations using the PIC and Monte Carlo codes between 0.3 and 30 MeV. The intense Bremsstrahlung x-ray source is used to radiograph an image quality indicator (IQI) heavily filtered with thick tungsten absorbers. Observations suggest that internal features of the IQI can be resolved up to an external areal density of 85 g/cm{sup 2}. The x-ray source size, inferred by the radiography of a thick resolution grid, is estimated to be approximately 400 μm (full width half maximum of the x-ray source Point Spread Function)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric currents in flare ribbons: Observations and three-dimensional standard model

We present for the first time the evolution of the photospheric electric currents during an eruptive X-class flare, accurately predicted by the standard three-dimensional (3D) flare model. We analyze this evolution for the 2011 February 15 flare using Helioseismic and Magnetic Imager/Solar Dynamics Observatory magnetic observations and find that localized currents in J-shaped ribbons increase to double their pre-flare intensity. Our 3D flare model, developed with the OHM code, suggests that these current ribbons, which develop at the location of extreme ultraviolet brightenings seen with Atmospheric Imaging Assembly imagery, are driven by the collapse of the flare's coronal current layer. These findings of increased currents restricted in localized ribbons are consistent with the overall free energy decrease during a flare, and the shapes of these ribbons also give an indication of how twisted the erupting flux rope is. Finally, this study further enhances the close correspondence obtained between the theoretical predictions of the standard 3D model and flare observations, indicating that the main key physical elements are incorporated in the model.

79 ASTRONOMY AND ASTROPHYSICS↗

Experiment-theory comparison for low frequency BAE modes in the strongly shaped H-1NF stellarator

Here, recent advances in the modeling, analysis, and measurement of fluctuations have significantly improved the diagnosis and understanding of Alfvén eigenmodes in the strongly shaped H-1NF helical axis stellarator. Experimental measurements, including 3D tomographic inversions of high resolution visible light images, are in close agreement with beta-induced Alfvén eigenmodes (BAEs) calculated using the compressible ideal MHD code, CAS3D. This is despite the low β in H-1NF, providing experimental evidence that these modes can exist due to compression that is induced by the strong shaping in stellarators, in addition to high β, as is the case in tokamaks. This is confirmed using the CONTI and CAS3D codes, which show significant gap structures at lower frequencies which contain BAE and beta-acoustic Alfvén eigenmodes (BAAEs). The BAEs are excited in the absence of a well confined energetic particle source, further confirming previous studies that thermal particles, electrons, or even radiation fluctuations can drive these modes. Datamining of magnetic probe data shows the experimentally measured frequency of these modes has a clear dependence on the rotational transform profile, which is consistent with a frequency dependency due to postulated confinement related temperature variations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Supersonic Heat Wave Propagation in Laser-Produced Underdense Plasma for Efficient X-Ray Generation

We have observed supersonic heat wave propagation in a low-density aerogel target ({rho} {approx} 3.2 mg/cc) irradiated at the intensity of 4 x 10{sup 14} W/cm{sup 2}. The heat wave propagation was measured with a time-resolved x-ray imaging diagnostics, and the results were compared with simulations made with the two-dimensional radiation-hydrodynamic code, RAICHO. Propagation velocity of the ionization front gradually decreased as the wave propagates into the target. The reason of decrease is due to increase of laser absorption region as the front propagates and interplay of hydrodynamic motion and reflection of laser propagation. These features are well reported with the simulation.

42 ENGINEERING↗

SU-E-T-318: Dosimetric Evaluation of ArcCHECK and 3DVH System Using Customized Polymer Gel Dosimeter

Purpose: ArcCHECK and 3DVH system (Sun Nuclear) can reconstruct the three-dimensional (3D) dose distribution and provide the DVH analysis in a patient. The aim of this study was to evaluate dosimetric accuracy of this system using customized polymer gel dosimeter, and also Gafchromic EBT3 films. Methods: Polyacrylamide-based gel contained magnesium chloride as a sensitizer (iPAGAT) was used in this study. Volumetric-modulated arc therapy (VMAT) plan was performed for the C-shape structure by the Eclipse treatment planning system (Varian) and used to irradiate the ArcCHECK by the Novalis Tx linear accelerator (Varian/BrainLAB). The cubic phantom filled with iPAGAT and EBT3 films placed in three orthogonal planes (axial, sagittal, and coronal) inserted into the I’mRT Phantom (IBA Dosimetry) simulated a patient were irradiated with the same VMAT plan. The measurement-guided 3D dose distribution was reconstructed using 3DVH software from the measured data of the ArcCHECK. The 3D dose distribution in iPAGAT was read out by Signa 1.5 T MRI system (GE), and 2D dose distribution on EBT3 was read out by color scanner (Epson). The comparison of all the dose distributions was performed with dose profiles and gamma index analysis in orthogonal planes using in-house developed software. Results: A good agreement was observed by overlaying the dose profiles of 3DVH, EBT3, and iPAGAT. The mean pass rates by gamma index analysis with 3%/3 mm criteria in orthogonal planes were 94.3% (3DVH vs EBT3), 91.1% (3DVH vs iPAGAT), and 96.4% (iPAGAT vs EBT3), respectively. Conclusion: 3D dose distribution reconstructed by ArcCHECK and 3DVH system was estimated accurately in a patient. However, slightly differences were observed between 3DVH and iPAGAT because of MRI noise, therefore further study is required to improve the accuracy of MRI based polymer gel dosimetry for the DVH analysis.

60 APPLIED LIFE SCIENCES↗

DeepLensSBI: Deep inference of simulated strong lenses in ground-based surveys

This code is used to train and test machine learning models and generate results and plots presented in 2501.08524 [astro-ph.IM]. The code is written in python. The goal of this work is to train ML models trained on simulated images of strong gravitational lenses. The trained model can then quickly infer properties of the lensed objects with uncertainty quantification.

Poh, Jason [Univ. of Chicago, IL (United States)] ↗

GRinding Automated Classification Engine

This work is an ML-driven framework for automated surface analysis of microscopy images. We create a training dataset by imaging stainless steel samples to benchmark four developed deep neural network architectures. These models, based on a YOLOv8n-cls backend, integrate image features and process metadata using various fusion methods to distinguish between acceptable and unacceptable surface finishes. This code is associated with publication "Classifying Alloy Surface Preparation Quality with Metadata-Infused Machine Learning for Rapid Alloy Discovery" for project APEX LDRD-ER (25-ERD-039)

Gongora, AldairE [Lawrence Livermore National Labo↗

Science Campaign-1 Pulsed Power Efforts [Slides]

The PHELIX portable pulsed-power driver is discussed. It is composed of two air-insulated, single Marx modules capable of storing 300 kJ of electrical energy. The Marx are cable coupled to a toroidal transformer with a 4:1 winding ratio. The experimental load is located at the center of the transformer. The components are mounted in a 8’x10’x18’ boxcar which can be moved in and out of the beam line at the LANL proton radiography facility and prevents EMI within the facility. PHELIX has successfully completed two liner implosion experiments with full diagnostic return from flash X-ray imaging, optical Faraday load current, and multi-channel PDV. Computational modeling with both the legacy 1D MHD code RAVEN and the LANL ASC-LAP FLAG code show good agreement with data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Technology Research and Development (NTRD) Technical Monthly February FY18

[LANL] Energy-resolved neutron imaging data on transmutation fuels (Figure 1A) containing Am and Np were reanalyzed. The analysis using the SAMMY code was focused on retrieving absolute densities for five isotopes, 238U, 239Pu, 240Pu, 241Am and 237Np. The bulk composition described by partial densities of the main isotopes 237Np, 239Pu, 240Pu, and 242Am, resultant from the initial analysis agreed to better than 0.1 g/cc with the partial densities determined by mass spectrometry, except for 238U, which was overestimated by the initial approach. It was found that due to only a single resonance of 238U present in the fitted energy range of 1eV to 9eV (Figure 1 B), the refined areal densities for 238U were statistically insignificant, resulting in large errors. Consequently, the fitted energy range was extended to 24eV to include a second 238U resonance (Figure 1C, D), which stabilized the 238U areal densities, providing excellent agreement for all five isotopes. (A. Losko and S. Vogel)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CALIBRATED ULTRA FAST IMAGE SIMULATIONS FOR THE DARK ENERGY SURVEY

Image simulations are becoming increasingly important in understanding the measurement process of the shapes of galaxies for weak lensing and the associated systematic effects. For this purpose we present the first implementation of the Monte Carlo Control Loops (MCCL), a coherent framework for studying systematic effects in weak lensing. It allows us to model and calibrate the shear measurement process using image simulations from the Ultra Fast Image Generator (UFig) and the image analysis software SExtractor. We apply this framework to a subset of the data taken during the Science Verification period (SV) of the Dark Energy Survey (DES). We calibrate the UFig simulations to be statistically consistent with one of the SV images, which covers ∼0.5 square degrees. We then perform tolerance analyses by perturbing six simulation parameters and study their impact on the shear measurement at the one-point level. This allows us to determine the relative importance of different parameters. For spatially constant systematic errors and point-spread function, the calibration of the simulation reaches the weak lensing precision needed for the DES SV survey area. Furthermore, we find a sensitivity of the shear measurement to the intrinsic ellipticity distribution, and an interplay between the magnitude-size and the pixel value diagnostics in constraining the noise model. This work is the first application of the MCCL framework to data and shows how it can be used to methodically study the impact of systematics on the cosmic shear measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

The molecular baryon cycle of M82

Baryons cycle into galaxies from the intergalactic medium and are converted into stars; a fraction of the baryons are ejected out of galaxies by stellar feedback. Here we present new high-resolution (3.″9; 68 pc) {sup 12}CO(2–1) and {sup 12}CO(3–2) images that probe these three stages of the baryon cycle in the nearby starburst M82. We combine these new observations with previous {sup 12}CO(1–0) and [Fe ii] images to study the physical conditions within the molecular gas. Using a Bayesian analysis and the radiative transfer code RADEX, we model temperatures and densities of molecular hydrogen, as well as column densities of CO. Besides the disk, we concentrate on two regions within the galaxy: an expanding super-bubble and the base of a molecular streamer. Shock diagnostics, kinematics, and optical extinction suggest that the streamer is an inflowing filament, with a mass inflow rate of molecular gas of 3.5 M{sub ⊙} yr{sup −1}. We measure the mass outflow rate of molecular gas of the expanding super-bubble to be 17 M{sub ⊙} yr{sup −1}, five times higher than the inferred inflow rate and 1.3 times the star formation rate of the galaxy. The high mass outflow rate and large star formation rate will deplete the galaxy of molecular gas within eight million years, unless there are additional sources of molecular gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Method and apparatus for contour mapping using synthetic aperture radar

By using two SAR antennas spaced a known distance, B, and oriented at substantially the same look angle to illuminate the same target area, pixel data from the two antennas may be compared in phase to determine a difference delta phi from which a slant angle theta is determined for each pixel point from an equation Delta phi = (2 pi B/lambda)sin(theta - alpha), where lambda is the radar wavelength and alpha is the roll angle of the aircraft. The height, h, of each pixel point from the aircraft is determined from the equation h = R cos theta, and from the known altitude, a, of the aircraft above sea level, the altitude (elevation), a', of each point is determined from the difference a - h. This elevation data may be displayed with the SAR image by, for example, quantizing the elevation at increments of 100 feet starting at sea level, and color coding pixels of the same quantized elevation. The distance, d, of each pixel from the ground track of the aircraft used for the display may be determined more accurately from the equation d = R sin theta.

Goldstein, R. M.↗

Liquid-Crystal Optical Correlator

Optical correlator uses commercially-available liquid-crystal television (LCTV) screen as spatial light modulator. Correlations with this device done at video frame rates, making such operations as bar-code recognition possible at reasonable cost. With further development, such correlator useful in automation, robotic vision, and optical image processing.

Liu, Hua-Kuang↗

Research into language concepts for the mission control center

A final report is given on research into language concepts for the Mission Control Center (MCC). The Specification Driven Language research is described. The state of the image processing field and how image processing techniques could be applied toward automating the generation of the language known as COmputation Development Environment (CODE or Comp Builder) are discussed. Also described is the development of a flight certified compiler for Comps.

Dellenback, Steven W.↗

Model-based VQ for image data archival, retrieval and distribution

An ideal image compression technique for image data archival, retrieval and distribution would be one with the asymmetrical computational requirements of Vector Quantization (VQ), but without the complications arising from VQ codebooks. Codebook generation and maintenance are stumbling blocks which have limited the use of VQ as a practical image compression algorithm. Model-based VQ (MVQ), a variant of VQ described here, has the computational properties of VQ but does not require explicit codebooks. The codebooks are internally generated using mean removed error and Human Visual System (HVS) models. The error model assumed is the Laplacian distribution with mean, lambda-computed from a sample of the input image. A Laplacian distribution with mean, lambda, is generated with uniform random number generator. These random numbers are grouped into vectors. These vectors are further conditioned to make them perceptually meaningful by filtering the DCT coefficients from each vector. The DCT coefficients are filtered by multiplying by a weight matrix that is found to be optimal for human perception. The inverse DCT is performed to produce the conditioned vectors for the codebook. The only image dependent parameter used in the generation of codebook is the mean, lambda, that is included in the coded file to repeat the codebook generation process for decoding.

Manohar, Mareboyana↗