Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Nonlinear Response of Extreme Precipitation to Warming in CESM1

The response of extreme precipitation to warming varies widely among climate models, especially in the tropics. In some models, there have been indications that the rate of response increases with warming – that the response is not linear. In this work, we investigate the evolution of extreme precipitation, quantified by the maximum accumulated precipitation in a day each year, in CESM1. We find that tropical- and global-average extreme precipitation are related to global mean surface temperature quadratically. This behavior is associated with an increase in the large scale fraction of extreme precipitation, and also strengthening circulation on extreme 25 precipitation days. Compared to other CMIP5 models, the nonlinearity in CESM1 is among the largest. One implication is that the difference between CESM1 simulations with full forcing and with fixed aerosols cannot be used to isolate the response of extreme precipitation to aerosols, as the resulting climates are not equally warm.

54 ENVIRONMENTAL SCIENCES↗

Adaptive Variational Quantum Computing Approaches for Green’s Functions and Nonlinear Susceptibilities

Here, we present and benchmark quantum computing approaches for calculating real-time single-particle Green’s functions and nonlinear susceptibilities of Hamiltonian systems. The approaches leverage adaptive variational quantum algorithms for state preparation and propagation. Using automatically generated compact circuits, the dynamical evolution is performed over sufficiently long times to achieve adequate frequency resolution of the response functions. We showcase accurate Green’s function calculations using a statevector simulator on classical hardware for Fermi-Hubbard chains of 4 and 6 sites, with maximal ansatz circuit depths of 65 and 424 layers, respectively, and for the molecule LiH with a maximal ansatz circuit depth of 81 layers. Additionally, we consider an antiferromagnetic quantum spin-1 model that incorporates the Dzyaloshinskii-Moriya interaction to illustrate calculations of the third-order nonlinear susceptibilities, which can be measured in two-dimensional coherent spectroscopy experiments. These results demonstrate that real-time approaches using adaptive parametrized circuits to evaluate linear and nonlinear response functions can be feasible with near-term quantum processors.

97 MATHEMATICS AND COMPUTING↗

A Numerical Simulation Of The Pulse Sequence Reconstruction in AC Biased TESs With a {beta} Source

We study the response of micro-calorimeters based on Ir/Au TESs biased by an AC voltage in the MHz range to the power input generated by beta emission in a Re source thermally connected to the calorimeter itself. The micro-calorimeter is assumed to work at -80 mK, and the energy pulses corresponding to the beta emission have an energy distributed between zero and 2.58 KeV. In this numerical simulation the TES is inserted in a RLC resonating circuit, with a low quality factor. The thermal conductivities between the source and the calorimeter and that from the calorimeter to the heat sink are non-linear. The superconducting to normal transition of the TES is described by a realistic non-linear model. The AC current at the carrier frequency, modulated by the changing resistance of the TES, is demodulated and the output is filtered. The resulting signal is analyzed to deduce the attainable time resolution and the linearity of the response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attribution of gamma-ray background collected by a mobile detector system to its surroundings using panoramic video

Mobile radiation detector systems are important tools for detecting radiological and nuclear sources outside of regulatory control, but due to their mobility, they are subject to complex and varying backgrounds in most realistic operational scenarios. Recent work has found correlations between non-radiological contextual information and gamma-ray spectral features that can be used to decrease false alarm rates, however a more complete understanding of background source terms has been elusive. A measurement campaign developed a full radiological characterization of a controlled facility that roughly corresponded to two city blocks. As part of the campaign, the Radiological Multi-sensor Analysis Platform (RadMAP) collected extensive multi-sensor data. In this work, RadMAP’s panoramic video data were used to visually identify several different materials and quantify the detector response to each material. A linear model was fit between the material responses and radiological features, and the results demonstrate reasonable agreement with ground truth flux measurements for each material. This paper will describe the data collection, processing, and analysis of the gamma-ray and video data from RadMAP. The paper will conclude with perspectives on the applicability of such a method to less controlled environments both with respect to achieving better understanding the sources of variability of background radiation in urban environments and whether such methods could be leveraged in operational scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of AP particle size on combustion response to crossflow

An analytical model is developed for the linearized velocity-coupled combustion response function. The model treats elements of response to perturbations in pressure, in composition due to the heterogeneity of composite propellants, and in crossflow velocity. The effects of AP particle size are accounted for in terms of effects on controlling ballistics properties and in terms of fluctuations in propellant composition. There are two facets of the crossflow problem: the effect of crossflow velocity on the various response elements, and the response to velocity perturbations. Both are dealt with in this paper. Important trends derived from series of parametric computations are described.

Cohen, N. S.↗

Detection and Automated Scoring of Dicentric Chromosomes in Nonstimulated Lymphocyte Prematurely Condensed Chromosomes After Telomere and Centromere Staining

Purpose: To combine telomere and centromere (TC) staining of premature chromosome condensation (PCC) fusions to identify dicentrics, centric rings, and acentric chromosomes, making possible the realization of a dose–response curve and automation of the process. Methods and Materials: Blood samples from healthy donors were exposed to {sup 60}Co irradiation at varying doses up to 8 Gy, followed by a repair period of 8 hours. Premature chromosome condensation fusions were carried out, and TC staining using peptide nucleic acid probes was performed. Chromosomal aberration (CA) scoring was carried out manually and automatically using PCC-TCScore software, developed in our laboratory. Results: We successfully optimized the hybridization conditions and image capture parameters, to increase the sensitivity and effectiveness of CA scoring. Dicentrics, centric rings, and acentric chromosomes were rapidly and accurately detected, leading to a linear-quadratic dose–response curve by manual scoring at up to 8 Gy. Using PCC-TCScore software for automatic scoring, we were able to detect 95% of dicentrics and centric rings. Conclusion: The introduction of TC staining to the PCC fusion technique has made possible the rapid scoring of unstable CAs, including dicentrics, with a level of accuracy and ease not previously possible. This new approach can be used for biological dosimetry in radiation emergency medicine, where the rapid and accurate detection of dicentrics is a high priority using automated scoring. Because there is no culture time, this new approach can also be used for the follow-up of patients treated by genotoxic therapy, creating the possibility to perform the estimation of induced chromosomal aberrations immediately after the blood draw.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamical Sensitivity in Response to a Wide Range of Abrupt CO 2 Forcings

An improved understanding of dynamical variability is important for projecting future changes in extratropical weather and the interaction between the extratropical troposphere and the tropics, stratosphere, cryosphere and ocean. Despite their simplicity, the abrupt 2x- and 4xCO 2 forcing simulations from the Coupled Model Intercomparison Project (CMIP) Phase 6 DECK experiments enable a mechanistic look into the forcing and feedback response characteristics of models that can be unambiguously attributed to an increase in carbon dioxide concentrations. Thus, while typically used to evaluate the climate sensitivity in models, with a primary focus on global surface temperature change, here we focus on several measures of extratropical variability, including projected changes in the storm tracks and in stratospheric polar vortex variability. Results are primarily based on simulations produced using low- and high-top versions of the NASA Goddard Institute for Space Studies Model (ModelE) but results are also presented from the larger CMIP6 multi-model ensemble. In addition to the 2x- and 4xCO 2 simulations, we also explore the linearity of the response of extratropical dynamical variability in ModelE to varying levels of CO 2 spanning the range 1/8-8xCO 2 . In particular, we show that the expansion of the jet streams varies nonlinearly with increasing CO 2 , especially in the Northern Hemisphere, and that this can be interpreted in terms of variations in ocean heat transport. The impact of composition feedbacks on changes in variability is also discussed.

dynamical variability↗

Characterization of a gated fiber-optic-coupled detector for application in clinical electron beam dosimetry

Purpose: Assessment of the fundamental dosimetric characteristics of a novel gated fiber-optic-coupled dosimetry system for clinical electron beam irradiation. Methods: The response of fiber-optic-coupled dosimetry system to clinical electron beam, with nominal energy range of 6-20 MeV, was evaluated for reproducibility, linearity, and output dependence on dose rate, dose per pulse, energy, and field size. The validity of the detector system's response was assessed in correspondence with a reference ionization chamber. Results: The fiber-optic-coupled dosimetry system showed little dependence to dose rate variations (coefficient of variation {+-}0.37%) and dose per pulse changes (with 0.54% of reference chamber measurements). The reproducibility of the system was {+-}0.55% for dose fractions of {approx}100 cGy. Energy dependence was within {+-}1.67% relative to the reference ionization chamber for the 6-20 MeV nominal electron beam energy range. The system exhibited excellent linear response (R{sup 2}=1.000) compared to reference ionization chamber in the dose range of 1-1000 cGy. The output factors were within {+-}0.54% of the corresponding reference ionization chamber measurements. Conclusions: The dosimetric properties of the gated fiber-optic-coupled dosimetry system compare favorably to the corresponding reference ionization chamber measurements and show considerable potential for applications in clinical electron beam radiotherapy.

60 APPLIED LIFE SCIENCES↗

Development of an Additively Manufactured Turbine Blade Tuned Mass Absorber

An innovative concept using a tuned mass absorber for resonant response reduction of turbine blades that is integrally fabricated into the blades using additive manufactured has been developed. Avoiding high resonant response and resulting high cycle fatigue failure is a major concern of the $100B worldwide turbine industry, which encompasses power generation, jet engines and rocket engine turbomachinery. Blade failure is potentially catastrophic, and although preventative measures using dampers do exist, these solutions are extremely expensive to develop and are not always effective. In addition, many of the existing techniques do not work for newer integrally bladed disks (or blisks), where there is no inherent damping in the assembly. The proposed concept, in which a tuned mass absorber re-arranges the structural dynamics and moves energy from the blade to the absorber, is designed specifically for blisks, and is intentionally linear, enabling accurate response prediction during design. Single blade prototypes have been analyzed, fabricated, and tested, and different absorber concepts have shown a reduction in response of up to 60%. After an extensive commercialization and prior art search, MSFC determined the innovation merited the generation and submission of a patent application in August ’21. Funding is now being sought to fabricate a 20-bladed blisk which would be spun at operational speeds with substantially higher and more realistic pressure loads in a special spin facility. Successful completion of this program would raise the TRL from 3/4 to 6/7, significantly improving the viability for adoption of the concept not only in rocket engines but other industrial applications as well.

Turbine Blades↗

Development of a facility for large-scale testing of multistory buildings

Current experimental research pertaining to response of structures subjected to lateral loads such as strong winds or earthquake motions is limited to either tests of single structural components or small scale multistory structures. The feasibility of developing a facility where large scale multistory structures could be loaded to failure is discussed. The test facility would consist of a series of hydraulic actuators mounted on reaction frames currently in use at the Marshall Space Flight Center for structural testing of spacecraft components. The actuators would be controlled from signals computed by an on-line analysis of measured data. This method of loading could be used to simulate inertial forces resisted by a structure behaving in the non linear range of response subjected to motion at the base or to impulses along the height as would occur during a strong earthquake or wind.

Abrams, D. P.↗

Time-Temperature Dependent Response of Filament Wound Composites for Flywheel Rotors

Flywheel energy storage offers an attractive alternative to battery systems used in space applications such as the International Space Station. Rotor designs capable of high specific energies benefit from the load carrying capacity of hoop wound carbon fibers but their long-term durability may be limited by time-temperature dependent radial deformations. This was investigated for the carbon/epoxy rotor material, IM7/8552. Coupon specimens were sectioned from filament wound panels. These were tested in compression and tension at room temperature (RT), 95 and 135 C for strain rates from 5x10(exp -6) per second to 5x10(exp -3) per second. Time, temperature and load sign dependent effects were significant transverse to the fiber. At -0.5 percent strain for 72 hr, compressive stresses relaxed 16.4 percent at 135 C and 13 percent at 95 C. Tensile stresses relaxed only 7 percent in 72 hr at 135 C for 0.5 percent strain. Using linear hereditary material response and Boltzmann s principle of superposition to describe this behavior is problematic if not intractable. Micromechanics analysis including the effects of processing residual stresses is needed to resolve the paradoxes. Uniaxial compressive stress relaxation data may be used to bound the loss of radial pre-load stresses in flywheel rotors.

Thesken, John C.↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high-speed vertical optical trap for the mechanical testing of living cells at piconewton forces

Although atomic force microscopy is often the method of choice to probe the mechanical response of (sub)micrometer sized biomaterials, the lowest force that can be reliably controlled is limited to ≈0.1 nN. For soft biological samples, like cells, such forces can already lead to a strain large enough to enter the non-elastic deformation regime. To be able to investigate the response of single cells at lower forces we developed a vertical optical trap. The force can be controlled down to single piconewtons and most of the advantages of atomic force microscopy are maintained, such as the symmetrical application of forces at a wide range of loading rates. Typical consequences of moving the focus in the vertical direction, like the interferometric effect between the bead and the coverslip and a shift of focus, were quantified and found to have negligible effects on our measurements. With a fast responding force feedback loop we can achieve deformation rates as high as 50 μm/s, which allow the investigation of the elastic and viscous components of very soft samples. The potential of the vertical optical trap is demonstrated by measuring the linearity of the response of single cells at very low forces and a high bandwidth of deformation rates.

36 MATERIALS SCIENCE↗

A variable structure approach to robust control of VTOL aircraft

This paper examines the application of variable structure control theory to the design of a flight control system for the AV-8A Harrier in a hover mode. The objective in variable structure design is to confine the motion to a subspace of the total state space. The motion in this subspace is insensitive to system parameter variations and external disturbances that lie in the range space of the control. A switching type of control law results from the design procedure. The control system was designed to track a vector velocity command defined in the body frame. For comparison purposes, a proportional controller was designed using optimal linear regulator theory. Both control designs were first evaluated for transient response performance using a linearized model, then a nonlinear simulation study of a hovering approach to landing was conducted. Wind turbulence was modeled using a 1052 destroyer class air wake model.

Calise, A. J.↗

Evaluation of Biologic Effective Dose and Schedule of Fractionation for Preoperative Radiotherapy for Rectal Cancer: Meta-Analyses and Meta-Regression;Rectal cancer; Preoperative radiotherapy; Biologic effective dose; Meta-analysis

Purpose: To evaluate whether the risk of local recurrence depends on the biologic effective dose (BED) or fractionation dose in patients with resectable rectal cancer undergoing preoperative radiotherapy (RT) compared with surgery alone. Methods and Materials: A meta-analysis of randomized controlled trials (RCTs) was performed. The MEDLINE, Embase, CancerLit, and Cochrane Library databases were systematically searched for evidence. To evaluate the dose-response relationship, we conducted a meta-regression analysis. Four subgroups were created: Group 1, RCTs with a BED >30 Gy{sub 10} and a short RT schedule; Group 2, RCTs with BED >30 Gy{sub 10} and a long RT schedule; Group 3, RCTs with BED {<=}30 Gy{sub 10} and a short RT schedule; and Group 4, RCTs with BED {<=}30 Gy{sub 10} and a long RT schedule. Results: Our review identified 21 RCTs, yielding 9,097 patients. The pooled results from these 21 randomized trials of preoperative RT showed a significant reduction in mortality for groups 1 (p = .004) and 2 (p = .03). For local recurrence, the results were also significant in groups 1 (p = .00001) and 2 (p = .00001).The only subgroup that showed a greater sphincter preservation (SP) rate than surgery was group 2 (p = .03). The dose-response curve was linear (p = .006), and RT decreased the risk of local recurrence by about 1.7% for each Gy{sub 10} of BED. Conclusion: Our data have shown that RT with a BED of >30 Gy{sub 10} is more efficient in reducing local recurrence and mortality rates than a BED of {<=}30 Gy{sub 10}, independent of the schedule of fractionation used. A long RT schedule with a BED of >30 Gy{sub 10} should be recommended for sphincter preservation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evidence for Interannual to Decadal Variations in Hadley and Walker Circulations and Links to Water and Energy Fluxes

Mass and energy transports associated with the Hadley and Walker circulations are important components of the earth s climate system and are strongly linked to hydrologic processes. Interannual to decadal variation in these flows likely signify a combination of natural climate noise as well as a response to anthropgenic forcing. There remains considerable uncertainty in quantifying variations in these flows. Evidence in the surface pressure record supports a weakening of the Walker circulation over the Pacific in recent decades. Conversely the NCEP / NCAR and ERA 40 reanalyses indicate that the Hadley circulation has increased in strength over the last two decades, though these analyses depict significantly different mass circulation changes. Interestingly, the NCEP - II / DOE reanalysis contains essentially no Hadley circulation changes. Most climate model integrations anticipate a weakening of both tropical circulations associated with stronger static stability. Clearly there is much uncertainty not only with the mass transports, but also how they are linked to water and energy balance of the planet through variations in turbulent heat and radiative fluxes and horizontal exports / imports of energy. Here we examine heat and water budget variations from a number of reanalysis products and focus on the linear and nonlinear response of ENSO warm and cold events as opportunities to study budget variations over the past 15-20 years. Our analysis addresses such questions as To what extent do Hadley and Walker Cell variations compensate each other on mass and energy transport? Do static stability adjustments appear to constrain fractional precipitation response vs. fractional water vapor response? We appeal to constraints offered by GPCP precipitation, SSWI ocean evaporation estimates, and ISCCP-FD radiative fluxes, and other satellite data sets to interpret and confirm reanalysis-based diagnostics. Using our findings we also attempt to place in context the recent findings that tropical ocean evaporation increased by order 5% or more during the 1990s, reconciling this with GPCP precipitation variations.

Robertson, Franklin↗

Modulation of DNA polymerase beta-dependent base excision repair in cultured human cells after low dose exposure to arsenite

Base excision repair (BER) is crucial for development and for the repair of endogenous DNA damage. However, unlike nucleotide excision repair, the regulation of BER is not well understood. Arsenic, a well-established human carcinogen, is known to produce oxidative DNA damage, which is repaired primarily by BER, whilst high doses of arsenic can also inhibit DNA repair. However, the mechanism of repair inhibition by arsenic and the steps inhibited are not well defined. To address this question we have investigated the regulation of DNA polymerase {beta} (Pol {beta}) and AP endonuclease (APE1), in response to low, physiologically relevant doses of arsenic. GM847 lung fibroblasts and HaCaT keratinocytes were exposed to sodium arsenite, As(III), and mRNA, protein levels and BER activity were assessed. Both Pol {beta} and APE1 mRNA exhibited significant dose-dependant down regulation at doses of As(III) above 1 {mu}M. However, at lower doses Pol {beta} mRNA and protein levels, and consequently, BER activity were significantly increased. In contrast, APE1 protein levels were only marginally increased by low doses of As(III) and there was no correlation between APE1 and overall BER activity. Enzyme supplementation of nuclear extracts confirmed that Pol {beta} was rate limiting. These changes in BER correlated with overall protection against sunlight UV-induced toxicity at low doses of As(III) and produced synergistic toxicity at high doses. The results provide evidence that changes in BER due to low doses of arsenic could contribute to a non-linear, threshold dose response for arsenic carcinogenesis.

60 APPLIED LIFE SCIENCES↗

The BATSE SLED: The problem and the correction

The Burst And Transient Source Experiment (BATSE) has been in space for 4 months and, by anyone's reckoning, is performing better than even the most optimistic pre-flight predictions. That doesn't mean there haven't been some small surprises. Because of the discreteness of gamma-ray energies available to us in pre-flight testing, we could not subject the instrument to the continuous distribution of energies it now sees in space. Therefore, it was not until the beginning of mission operations that a small non-linearity was discovered in the low energy region of the SPD spectra. The nickname for this depression is the SLED (Spectroscopy Low-Energy Depression). Sample spectra for module 6 at two gains (1X and 0.4X) are given. Note that the position of the sled is gain-independent in channel space. A further study on a non-flight module discovered the cause lay in the spectroscopy analog electronics. Above a certain energy threshold, the digital signal from the SPEC-FAST2 discriminator causes, in effect, an extra small amount of charge to be added to the SHER analog input. The laboratory measurements of SHER output energy as a function of input energy are presented. The change of slope at the point of the SLED results in narrower bin widths for the channels in that region. The SLED is approximately 5 channels wide. It should be mentioned that below the SLED and for many decades above the SLED the response is extremely linear. The proposed fix was to move the lower straight line up to match the extrapolation of the upper straight line, shown by the dotted line. In effect, this means reassigning channel numbers. All channel edges lower than the SLED are moved a fixed amount to higher channel numbers. Channel edges in the SLED are moved a different amount depending on their position. The latter obviously results in narrower channel widths in energy space.

Lestrade, John Patrick↗