A New FE Modeling Method for Isothermal Local Loading Process of Large-scale Complex Titanium Alloy Components Based on DEFORM-3D

Isothermal local loading process provides a new way to form large-scale complex titanium alloy components. The forming process is characterized by an extreme size (large scale in global and compared small size in regional), multi-parameter effects, and complicated loading path. To establish a reasonable finite element model is one of the key problems urgently to be solved in the research and development of isothermal local loading forming process of large-scale complex titanium alloy components. In this paper, a new finite element model of the isothermal local loading process is developed under the DEFORM-3D environment based on the solution of some key techniques. The modeling method has the following features: (1) different meshing techniques are used in different loading areas and the number of meshed elements is determined according to the deformation characteristic in different local loading steps in order to improve computational efficiency; (2) the accurate magnitude of the friction factor under titanium alloy hot forming (isothermal forming) condition is adopted instead of the typical value for lubricated hot forming processes; (3) different FEM solvers are chosen at different stages according to the loading characteristic and the contact state; (4) in contrast to the local component model, a full 3D component is modeled to simulate the process. The 3D-FE model is validated by experimental data of a large-scale bulkhead forming under isothermal local loading. The model can describe the quantitative relationships between the forming conditions and the forming results. The results of the present study may provide a basis for studying the local deformation mechanism, selecting the reasonable parameters, optimizing the die design and the process control in isothermal local loading process of large-scale complex titanium alloy components.

36 MATERIALS SCIENCE↗

Adaptive control of dual-arm robots

Three strategies for adaptive control of cooperative dual-arm robots are described. In the position-position control strategy, the adaptive controllers ensure that the end-effector positions of both arms track desired trajectories in Cartesian space despite unknown time-varying interaction forces exerted through the load. In the position-hybrid control strategy, the adaptive controller of one arm controls end-effector motions in the free directions and applied forces in the constraint directions, while the adaptive controller of the other arm ensures that the end-effector tracks desired position trajectories. In the hybrid-hybrid control strategy, the adaptive controllers ensure that both end-effectors track reference position trajectories while simultaneously applying desired forces on the load. In all three control strategies, the cross-coupling effects between the arms are treated as disturbances which are rejected by the adaptive controllers while following desired commands in a common frame of reference. The adaptive controllers do not require the complex mathematical model of the arm dynamics or any knowledge of the arm dynamic parameters or the load parameters such as mass and stiffness. The controllers have simple structures and are computationally fast for on-line implementation with high sampling rates.

Seraji, H.↗

PV output smoothing with energy storage

This report describes an algorithm, implemented in Matlab/Simulink, designed to reduce the variability of photovoltaic (PV) power output by using a battery. The purpose of the battery is to add power to the PV output (or subtract) to smooth out the high frequency components of the PV power that that occur during periods with transient cloud shadows on the PV array. The control system is challenged with the task of reducing short-term PV output variability while avoiding overworking the battery both in terms of capacity and ramp capability. The algorithm proposed by Sandia is purposely very simple to facilitate implementation in a real-time controller. The control structure has two additional inputs to which the battery can respond. For example, the battery could respond to PV variability, load variability or area control error (ACE) or a combination of the three.

14 SOLAR ENERGY↗

Regional Power System Black Start with Run-of-river Hydropower Plant and Battery Energy Storage

Battery energy storage systems (BESSs) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various critical services to the power grid. This paper presents the real-world experience of using a megawatt-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to restore a regional power system. To demonstrate this, we carry out power-hardware-in-the-loop experiments integrating an actual GFL- or GFM-controlled BESS and a load bank. Both the simulation and experimental results presented in this paper show the different roles of GFL- or GFM-controlled BESS in power system black starts. The results provide further insight for system operators on how GFL- or GFM-controlled BESS can enhance grid stability and how an ROR hydropower plant can be converted into a black-start-capable unit with the support of a small-capacity BESS. The results show that an ROR hydropower plant combined with a BESS has the potential of becoming one of enabling elements to perform bottom-up black-start schemes as opposed to conventional bottom-down method, thus enhancing the system resiliency and robustness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overheat Prevention in Solar-Powered Stirling Engines

Proposed controller for solar-powered Stirling engine prevents engine from burning up when energy added by Sun exceeds that withdrawn by load. Head-temperature controller used existing electrical control unit of Stirling engine to regulate power output in response to head temperature. Power out-put is varied so keeps head temperature fairly constant.

Garrigus, W. E.↗

Aeroservoelastic tailoring for lateral control enhancement

The need for effective aileron power for aircraft lateral control and turning maneuvers dates back to the Wright Brothers and their wing warping concept for active stabilization of their aircraft. Early researchers in Great Britain, Japan, Germany and the United States explored ways to increase the effectiveness of control aileron to generate a roll moment. The basic problem of aileron effectiveness and the interrelationship between structural distortion and the loads applied by the control surface is illustrated. A rigid wing/aileron surface will develop the capability to generate increased roll rates as airspeed increases. A flexible surface will become less effective as airspeed increases because of the twisting distortion created by the aft-mounted control surface. This tendency is further worsened by bending distortion of an aft swept wing. This study focuses its attention on the ability of a combined effort between structural redesign of a wing and sizing and placement of a control surface to create specified roll performance with a minimum hinge moment. This design optimization problem indicates the advantages of simultaneous consideration of structural design and control design.

Weisshaar, Terrence A.↗

Mathematical models for electrochemical impregnation of nickel electrodes

Single step and two-step tetramer precipitation models for electrochemical impregnation of nickel electrodes are presented. The objectives for developing the impregnation model are: to predict the impregnation conditions for uniform loading, to develop quality control tools for electrode manufacturing, and to use it as basis for predicting the performance of batteries with non-uniform loadings. This paper, with the help of graphs and charts, discusses the development and application of the impregnation model.

Ho, Chien-Hsien↗

Development of a preprototype trace contaminant control system

The steady state contaminant load model based on shuttle equipment and material test programs, and on the current space station studies was revised. An emergency upset contaminant load model based on anticipated emergency upsets that could occur in an operational space station was defined. Control methods for the contaminants generated by the emergency upsets were established by test. Preliminary designs of both steady state and emergency contaminant control systems for the space station application are presented.

Source record↗

Demand or Request: Will Load Behave?

Power planning engineers are trained to design an electric system that satisfies predicted electrical demand under stringent conditions of availability and power quality. Like responsible custodians, we plan for the provision of electrical sustenance and shelter to those in whose care regulators have given us the responsibility to serve. Though most customers accept this nurturing gladly, a growing number are concerned with the economic costs and environmental impacts of service at a time when technology (particularly distributed generation, storage, automation, and information networks) offers alternatives for localized control and competitive service. As customers’ and their systems mature, a new relationship with the electricity provider is emerging. Demand response is perhaps the first unsteady step where the customer participates as a partner in system operations. This paper explores issues system planners need to consider as demand response matures to significant levels beyond direct load control and toward a situation where service is requested and bargains are reached with the electricity provider based on desired load behavior. On one hand, predicting load growth and behavior appears more daunting than ever. On the other, for the first time load becomes a new resource whose behavior can be influenced during system operations to balance system conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL Works to Increase Electric Vehicle Efficiency Through Enhanced Thermal Management [Fact Sheet]

Researchers at NREL are providing new insight into how heating and cooling systems affect the distance that electric vehicles can travel on a single charge. Electric vehicle range can be reduced by as much as 68% per charge because of climate-control demands. NREL engineers are investigating opportunities to change this dynamic and increase driving range by improving vehicle thermal management. NREL experts are collaborating with automotive industry partners to investigate promising thermal management technologies and strategies, including zone-based cabin temperature controls, advanced heating and air conditioning controls, seat-based climate controls, vehicle thermal preconditioning, and thermal load reduction technologies.

30 DIRECT ENERGY CONVERSION↗

Optimal maneuvers at supersonic speeds in a vertical plane

This paper presents several optimal maneuvers of supersonic aircraft in a vertical plane. The general dimensionless equations of motion are derived and the computation of the optimal trajectories are carried out using the aerodynamics and engine characteristics of a light-weight fighter called the supercruiser. Because of the normalizing of the control variables, namely, the load factor and the thrust-to-weight ratio, the results applied to any supersonic aircraft. The optimality of the singular thrust control and the optimal junction of different subarcs are discussed. The proposed method of computing the optimal trajectory is very efficient and makes explicit the selection of the optimal control. The technique should be useful for performance assessment of supersonic aircraft with potential for implementation of onboard flight control system.

Vinh, N. X.↗

Six degrees of freedom vibration isolation using electromagnetic suspension

Experimental data are presented for modeling an electromagnet. Control laws are considered with and without flux feedback and with position and orientation information of the suspended body. Base motion and sensor noise are the principal disturbances. Proper selection of the geometrical operating point minimizes the passive coupling above the bandwidth of the control and filtering can attenuate the high frequency content of sensor noise. Six electromagnets are arranged in a configuration which optimizes the load support and provides control over all six degrees of freedom of the suspended body. The design is based on experimental data generated with a specially designed test facility. Application for suspension of a gravity wave antenna is discussed.

Lee, Sang-Il↗

Results obtained during accelerated transonic tests of the Bell XS-1 airplane in flights to a Mach number of 0.92

Results are presented of tests up to a Mach number of 0.92 at altitudes around 30,000 feet. The data obtained show that the airplane can be flown to this Mach number above 30,000 feet. Longitudinal trim changes have been experienced but the forces involved have been small. The elevator effectiveness decreased about one-half with increase of Mach number from 0.70 to 0.87. Buffeting has been experienced in level flight but it has been mild and the associated tail loads have been small. No aileron buzz or other flutter phenomena have been noted.

STABILITY, LONGITUDINAL - DYNAMIC↗

Performance and Implementation Requirements for Residential EV Smart Charge Management Strategies

As the electrification of transportation expands, electric vehicle (EV) charging as residential loads will continue to grow. Residential EV charging has the potential to increase feeder peak loads and decrease voltage quality. As a result of this growing energy demand driven by EV, utilities may employ the use of smart charge management (SCM) controls to modify charging load profiles and mitigate these grid impacts. It is important that utilities understand both the potential benefits-as well as possible implementation challenges-before considering this technology as a solution to managing growing EV loads. In order for an SCM strategy to be an effective solution, the potential benefits must outweigh the implementation challenges. This study establishes and tests a novel framework to assess the implementation requirements of different SCM controls. It identifies a range of requirements specific to various SCM controls and implementation approaches to compare the relative challenges associated with the deployment of each. When paired with analysis on the effectiveness of the ability of each control to mitigate grid impacts from EV charging, this assessment is critical in comparing the value potential of different SCM controls.

ADVANCED PROPULSION SYSTEMS↗

Advanced Control of Next Generation Offshore Wind Turbines

Advanced turbine controls and structural dampers have the potential to significantly reduce the cost of energy (CoE) for offshore wind turbines. Progress made in these two areas on a Department of Energy (DoE) funded program is reported. A lidar-assisted control strategy, with objective to reduce component loads and increase energy capture, is developed and implemented. The controller has been tested in both simulations and on a 3MW utility-scale prototype. The controller results indicate a significant reduction in the tower fatigue loads. In a parallel effort, potential of a passive and semi-active tuned-mass damper (TMD) is evaluated to mitigate fatigue and extreme loads. Simulation results with passive and semi-active TMD indicate significant load reduction for tower and substructure for both fixed-bottom and floating wind turbines. Finally, levelized cost of energy modeling process to account for benefits of advanced controls is discussed.

structural dampers. cost of energy, lidar-assisted↗

Electric Motor Noise from Small Quadcopters: Part II - Source Characteristics

The increased interest in electric motors for aircraft propulsion systems has driven interest in quantifying the contribution of electric motor noise to the overall sound levels and possibly human annoyance of the propulsion system. This work presents acoustic measurements of electric motors used for small quadcopters to quantify the sound produced by a number of outrunner motors with different types of controllers. Results are presented for loaded and unloaded motors as well as installed and uninstalled configurations. Motor resonance frequencies were measured and computed. Current probe measurements showed significant harmonic content in the supply current from the controllers for both the conventional and sinewave controllers. Acoustic results showed motor noise is typically radiated at frequencies near that for azimuthal vibration mode number 2 of the rotor which occurs at roughly 5000 Hz. Electric motor noise was evident in the spectra produced by many of the motor-controller combinations for motors loaded with propellers with levels often greater than those for the motor alone due to increases in the stator magnetic flux density with increased current. An installed quadcopter configuration produced increases in acoustic radiation over that of the uninstalled motor in a frequency range near the 1200 Hz azimuthal vibration mode 1 of the rotor.

Henderson, Brenda↗

Logic-controlled solid-state switchgear for 270 volt dc.

A feasibility study to design and demonstrate solid-state switchgear composed of circuit breakers and a power transfer switch is described. The switchgear operates on a nominal 270 Vdc circuit and controls power to a load up to 15 A. One circuit breaker may be interconnected to a second to form a power transfer switch. Breaker or switch on-off and transfer functions can be remotely controlled. Automatic overload trip-out is provided through an ultimate current trip and an I squared t trip for transient overcurrents lower than the ultimate current trip level. A number of reclosures with variable time delay between trip-out and reclosure are programmed and controlled by integrated analog and COSMOS logic circuits. A commutation circuit that creates minimal transient disturbances to either source or load was developed to interrupt current flow through the main SCR switching element.-

Waddington, D.↗

Helicopter sling loads

Computer program compares various control-system concepts for improving handling qualities of single-rotor helicopters carrying relatively-large external sling loads. Computer program developed to test these and other ideas helps to circumvent expensive prototype and field testing. Comparisons between (1) computed data and flight data, (2) simulation-system values and flight test data, and (3) pilot evaluations of simulation and actual-flight conditions are very favorable.