Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Investigation of Mode I Notch Toughness of Zr{sub 41.2}Ti{sub 13.8}Cu{sub 10}Ni{sub 12.5}Be{sub 22.5} Metallic Glass under Dynamic Loading Conditions

Based on dynamic three-point bending tests, the dynamic notch toughness (K{sub Q}{sup d}) of Zr{sub 41.2}Ti{sub 13.8}Cu{sub 10}Ni{sub 12.5}Be{sub 22.5} (Vit 1) bulk metallic glass (BMG) was found to be sensitive to stress intensity factor rate ( K-dot {sub Q}{sup d}), which varied from 5.21 to 31.90 MPa m{sup 1/2}. The number of shear bands (N{sub s}) in the notch tip plastic zone was quantitatively analyzed. The phenomenon wherein N{sub s} decreased with increasing loading rate was explained based on the theory of the shear transformation zone and the softening mechanism. Then, power law relationships were established among N{sub s}, K{sub Q}{sup d} and K-dot {sub Q}{sup d}. The results showed that shear bands can affect K{sub Q}{sup d} and K-dot {sub Q}{sup d} and act as a bridge connecting K{sub Q}{sup d} and K-dot {sub Q}{sup d}. The sensitivity of K{sub Q}{sup d} to K-dot {sub Q}{sup d} in BMGs can be well explained by the variation of N{sub s} with loading rate.

36 MATERIALS SCIENCE↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three-dimensional petrography of metal phases in equilibrated L chondrites: Effects of shock loading and dynamic compaction

To examine the role of impacts in the evolution of asteroids as seen through their chondritic offspring, we have performed a quantitative three dimensional (3D) study of metal grains in a suite of increasingly shocked L chondrites with synchrotron X-ray microtomography (XMT). Our data allow rigorous quantification of size-number distributions and collective morphology of Fe(Ni) metal phases in chondritic meteorites. At the resolution of our XMT measurements (8.4--17.9 {mu}m/voxel), the number of metal particles increase with higher degrees of petrographically identified shock loading, indicating a coalescing of Fe-Ni metal at or below this scale. Our results demonstrate that collective degrees of metal grain preferred orientation increase with greater degrees of impact-related compaction and shock loading. Ductile metal grains in L chondrites begin to show foliation at peak shock pressures < 5 GPa, pressures great enough to compact and indurate loosely bound chondritic material, and our results constitute evidence for multiple generations of impact events acting on the L parent body or bodies.

99 GENERAL AND MISCELLANEOUS↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis with Different Computing Environments

Contingency analysis is a key function in the Energy Management System (EMS) to assess the impact of various combinations of power system component failures based on state estimation. Contingency analysis is also extensively used in power market operation for feasibility test of market solutions. High performance computing holds the promise of faster analysis of more contingency cases for the purpose of safe and reliable operation of today’s power grids with less operating margin and more intermittent renewable energy sources. This paper evaluates the performance of counter-based dynamic load balancing schemes for massive contingency analysis under different computing environments. Insights from the performance evaluation can be used as guidance for users to select suitable schemes in the application of massive contingency analysis. Case studies, as well as MATLAB simulations, of massive contingency cases using the Western Electricity Coordinating Council power grid model are presented to illustrate the application of high performance computing with counter-based dynamic load balancing schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 4 kV/120 A SiC Solid-State DC Circuit Breaker Powered By a Load-Independent IPT System

This article introduces a 4 kV/120 A solid-state dc circuit breaker (DCCB) based on discrete SiC mosfets. The DCCB is designed in a five-layer tower structure. Each layer consists of a circular main conduction branch and an attached gate driver. There are two primary benefits of the proposed DCCB. First, it reduces conduction loss with multiple devices in parallel. Second, it achieves an ultrafast response speed with SiC mosfets. Moreover, the gate drivers of the DCCB are powered by a domino inductive power transfer (IPT) system. It achieves the load-independent constant-voltage output characteristics, which means the outputs are immune to load variations. Additionally, an IPT system prototype is implemented to test the power transfer performance. At 500-kHz frequency, the total output power reaches 15.73 W, which is sufficient to power on five gate drivers, with a peak transfer efficiency of 75.4%. The IPT system is tested to power a 4 kV/120 A DCCB prototype. It validates that the DCCB is effective to turn off 120 A current within 3.5 μs.

42 ENGINEERING↗

Semi-Supervised, Non-Intrusive Disaggregation of Nodal Load Profiles With Significant Behind-the-Meter Solar Generation

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract actual load profiles at transmission nodes with significant behind-the-meter solar generation, which remains a gap in the existing technology paradigm. This paper proposes an explicit yet efficient linear estimator to disaggregate actual load profiles at transmission buses with significant behind-the-meter (BTM) solar generations. The proposed estimator is based on disaggregating (i.e., extracting) at locations close to transmission buses under consideration. Further, to overcome the lack of “ground truth” and validate the performance of the proposed algorithms, we first propose semi-supervised mechanisms with parameter tuning as well as unsupervised clustering and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors, which we refer to as “Zone-to-Node (Z2N)” methods. Next, we further propose a bi-level Node-to-Node (N2N) framework that improves the overall disaggregation performances compared to Z2N. Numerical results are presented using real-world data at PJM Interconnection.

14 SOLAR ENERGY↗

Descriptive Analytics-Based Anomaly Detection for Cybersecure Load Forecasting

As power delivery systems evolve and become increasingly reliant on accurate forecasts, they will be more and more vulnerable to cybersecurity issues. A coordinated data attack by sophisticated adversaries can render existing data corrupt or outlier detection methods ineffective. This would have a very negative impact on operational decisions. The focus of this paper is to develop descriptive analytics-based methods for anomaly detection to protect the load forecasting process against cyberattacks to essential data. We propose an integrated solution (IS) and a hybrid implementation of IS (HIIS) that can detect and mitigate cyberattack induced long sequence anomalies. HIIS is also capable of improving true positive rates and reducing false positive rates significantly comparing with IS. The proposed HIIS can serve as an online cybersecure load forecasting scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Effect of Cyclic Loading on the Size of Coherent Scattering Regions of X-Ray Radiation in Crystalline Samples

The effect of cyclic loading on the magnitude of coherent scattering regions (CSR) of X-ray radiation and microstresses of the II type in various crystalline materials: semiconductor (samarium sulfide) and metal (steel, duralumin) has been found. The loading was carried out by compressing the samples in various ways: all-round, uniaxial, bending compression. It is shown that with an increase in the number of compression cycles, the CSR values in all cases decrease, and the microstresses increase. These values can serve as parameters to assess the degree of mechanical fatigue of the material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Joint Effect of Small Additives of Carbon Nanoparticles of Different Morphologies on the Mechanical Characteristics of Cross-Linked Polyurethanes under Static and Dynamic Loads

Influence of small additives of fullerene, graphene oxide, and their combinations in the ratio of 85 : 15 on the structure and mechanical properties of cross-linked polyurethanes under static and dynamic loads has been investigated. Nanocomposite structures have been studied by X-ray diffraction analysis and scanning electron microscopy. It is shown that the presence of carbon nanoparticles in the composite reduces its strength under both static and shock-wave loads. The synergistic effect of the mixture of carbon nanoparticles manifests itself as an increase in the elastic modulus by a factor of 1.25 in comparison with the initial polymer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plug and Process Loads Capacity and Power Requirements Analysis

This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus of this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing Design Heating Loads in Superinsulated Buildings

The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculation methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Participation in Ancillary Services

Of five basic types of load response (participation), DOE load participation in ancillary services workshop focused on bulk power system reliability services regulation response and spinning reserve.

DOE load participation in ancillary services↗

Analyzing Design Heating Loads in Superinsulated Buildings

Super-insulated homes offer many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for super insulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware Implementation and Market Impacts of Grid-Supportive Functions in End-Use Loads

Grid-supportive loads (GSLs) are power electronics-based end-use loads that can provide frequency response and other grid services by autonomously adjusting their output power using local grid measurements. This report provides details on GSL hardware design options and their associated costs and benefits for multiple devices, including EV chargers, refrigerators, and heat pumps. We consider mechanisms to incentivize adoption of GSLs at scale and estimate the quantity of frequency response that can be procured with GSLs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Best Practices in Electricity Load Modeling and Forecasting for Long-Term Power System Planning

This document highlights the best practices on data acquisition and management, modeling and stakeholder engagement required for enhanced load modeling and forecasting. Each section is interspersed with case studies to highlight lessons from different country contexts to highlight both cross-cutting and location specific best practices needed to conduct robust load modeling and forecasting.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BuildingsBench: A Large-Scale Dataset of 900K Buildings and Benchmark for Short-Term Load Forecasting

The BuildingsBench datasets consist of: - Buildings-900K: A large-scale dataset of 900K buildings for pretraining models on the task of short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock. - 7 real residential and commercial building datasets for benchmarking two downstream tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. Buildings-900K can be used for pretraining models on day-ahead STLF for residential and commercial buildings. The specific gap it fills is the lack of large-scale and diverse time series datasets of sufficient size for studying pretraining and finetuning with scalable machine learning models. Buildings-900K consists of synthetically generated energy consumption time series. It is derived from the NREL End-Use Load Profiles (EULP) dataset (see link to this database in the links further below). However, the EULP was not originally developed for the purpose of STLF. Rather, it was developed to "...help electric utilities, grid operators, manufacturers, government entities, and research organizations make critical decisions about prioritizing research and development, utility resource and distribution system planning, and state and local energy planning and regulation." Similar to the EULP, Buildings-900K is a collection of Parquet files and it follows nearly the same Parquet dataset organization as the EULP. As it only contains a single energy consumption time series per building, it is much smaller (~110 GB). BuildingsBench also provides an evaluation benchmark that is a collection of various open source residential and commercial real building energy consumption datasets. The evaluation datasets, which are provided alongside Buildings-900K below, are collections of CSV files which contain annual energy consumption. The size of the evaluation datasets altogether is less than 1GB, and they are listed out below: 1. ElectricityLoadDiagrams20112014 2. Building Data Genome Project-2 3. Individual household electric power consumption (Sceaux) 4. Borealis 5. SMART 6. IDEAL 7. Low Carbon London A README file providing details about how the data is stored and describing the organization of the datasets can be found within each data lake version under BuildingsBench.

Array↗