Search NASA⌕ Search

SEARCH · Search NASA

Results for “maximum likelihood”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Applying the neutron scatter camera to treaty verification and warhead monitoring.

The neutron scatter camera was originally developed for a range of SNM detection applications. We are now exploring the feasibility of applications in treaty verification and warhead monitoring using experimentation, maximum likelihood estimation method (MLEM), detector optimization, and MCNP-PoliMi simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Differential Evolution to Optimize Learning from Signals and Enhance Network Security

Computer and communication network attacks are commonly orchestrated through Wireless Access Points (WAPs). This paper summarizes proof-of-concept research activity aimed at developing a physical layer Radio Frequency (RF) air monitoring capability to limit unauthorizedWAP access and mprove network security. This is done using Differential Evolution (DE) to optimize the performance of a Learning from Signals (LFS) classifier implemented with RF Distinct Native Attribute (RF-DNA) fingerprints. Performance of the resultant DE-optimized LFS classifier is demonstrated using 802.11a WiFi devices under the most challenging conditions of intra-manufacturer classification, i.e., using emissions of like-model devices that only differ in serial number. Using identical classifier input features, performance of the DE-optimized LFS classifier is assessed relative to a Multiple Discriminant Analysis / Maximum Likelihood (MDA/ML) classifier that has been used for previous demonstrations. The comparative assessment is made using both Time Domain (TD) and Spectral Domain (SD) fingerprint features. For all combinations of classifier type, feature type, and signal-to-noise ratio considered, results show that the DEoptimized LFS classifier with TD features is uperior and provides up to 20% improvement in classification accuracy with proper selection of DE parameters.

99 GENERAL AND MISCELLANEOUS↗

Second Season QUIET Observations: Measurements of the CMB Polarization Power Spectrum at 95 GHz

The Q/U Imaging ExperimenT (QUIET) has observed the cosmic microwave background (CMB) at 43 and 95GHz. The 43-GHz results have been published in QUIET Collaboration et al. (2011), and here we report the measurement of CMB polarization power spectra using the 95-GHz data. This data set comprises 5337 hours of observations recorded by an array of 84 polarized coherent receivers with a total array sensitivity of 87 {mu}K{radical}s. Four low-foreground fields were observed, covering a total of {approx} 1000 square degrees with an effective angular resolution of 12'.8, allowing for constraints on primordial gravitational waves and high-signal-to-noise measurements of the E-modes across three acoustic peaks. The data reduction was performed using two independent analysis pipelines, one based on a pseudo-C{ell} (PCL) cross-correlation approach, and the other on a maximum-likelihood (ML) approach. All data selection criteria and filters were modified until a predefined set of null tests had been satisfied before inspecting any non-null power spectrum. The results derived by the two pipelines are in good agreement. We characterize the EE, EB and BB power spectra between {ell} = 25 and 975 and find that the EE spectrum is consistent with {Lambda}CDM, while the BB power spectrum is consistent with zero. Based on these measurements, we constrain the tensor-to-scalar ratio to r = 1.1{sup +0.9}{sub -0.8} (r < 2.8 at 95% C.L.) as derived by the ML pipeline, and r = {sup +0.9}{sub -0.8} (r < 2.7 at 95% C.L.) as derived by the PCL pipeline. In one of the fields, we find a correlation with the dust component of the Planck Sky Model, though the corresponding excess power is small compared to statistical errors. Finally, we derive limits on all known systematic errors, and demonstrate that these correspond to a tensor-to-scalar ratio smaller than r = 0.01, the lowest level yet reported in the literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust statistical reconstruction for charged particle tomography

Systems and methods for charged particle detection including statistical reconstruction of object volume scattering density profiles from charged particle tomographic data to determine the probability distribution of charged particle scattering using a statistical multiple scattering model and determine a substantially maximum likelihood estimate of object volume scattering density using expectation maximization (ML/EM) algorithm to reconstruct the object volume scattering density. The presence of and/or type of object occupying the volume of interest can be identified from the reconstructed volume scattering density profile. The charged particle tomographic data can be cosmic ray muon tomographic data from a muon tracker for scanning packages, containers, vehicles or cargo. The method can be implemented using a computer program which is executable on a computer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PARAMETER ESTIMATION OF THE EXPONENTIALLY DAMPED SINUSOID FOR NOISY SIGNALS

The damped sinusoid equation is a common model for many scientific processes involving damped periodic signals. Here we present two methods for estimating the damped sinusoid parameters for noisy signals. Both methods are based upon an exact, closed form solution to fit the parameters for signals without noise, and they estimate the parameters for the noisy signals by the statistical maximum likelihood criterion. The first method relies on an optimizer to minimize the mean square signal error. The second method estimates the parameters by direct calculation and is suitable when the signal noise is small and the frequencies are sufficiently far from the integer and half integer values.

Pelaia, II, Tom↗

The IceCube Neutrino Observatory, the Pierre Auger Observatory and the Telescope Array: Joint Contribution to the 34th International Cosmic Ray Conference (ICRC 2015)

We have conducted three searches for correlations between ultra-high energy cosmic rays detected by the Telescope Array and the Pierre Auger Observatory, and high-energy neutrino candidate events from IceCube. Two cross-correlation analyses with UHECRs are done: one with 39 cascades from the IceCube `high-energy starting events' sample and the other with 16 high-energy `track events'. The angular separation between the arrival directions of neutrinos and UHECRs is scanned over. The same events are also used in a separate search using a maximum likelihood approach, after the neutrino arrival directions are stacked. To estimate the significance we assume UHECR magnetic deflections to be inversely proportional to their energy, with values $3^\circ$, $6^\circ$ and $9^\circ$ at 100 EeV to allow for the uncertainties on the magnetic field strength and UHECR charge. A similar analysis is performed on stacked UHECR arrival directions and the IceCube sample of through-going muon track events which were optimized for neutrino point-source searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localization-Based detection under network losses

We consider a networked system of sensors that measure the intensity of a source amidst background inside a two-dimensional monitoring area. The source intensity decays away from it, and the corresponding sensor measurements are random with a parameter determined by the intensity at sensor location. The detection problem is to infer the presence of a source based on measurements. Under a statistical independence condition, we show that a detection method based on maximum likelihood fuser performs below the individual sensors in presence of network losses. It has been previously shown that the localization of a source using measurements from multiple sensors leads to an improved detection, thereby establishing the effectiveness of a network over single or co-located sensors. We show that the communication losses degrade such network detection performance, particularly to levels below that of a single sensor under heavy losses. Under fairly general conditions on the source intensity decay functions and underlying measurement distributions, we quantify the loss of performance of the localization-based detection as a function of loss rate and packing number of state space. We present simulation and experimental results that illustrate the performance degradations due to network losses in detecting radiation sources.

cyber-physical networks↗

Search for CP violation in $D^0 \to h^+h^-$ decays at CDF

I report on a measurement of \CP-violating asymmetries ($A_{\Gamma}$) between effective lifetimes of $D^0$ or $\bar{D}^0$ in fully reconstructed $D^0\to K^+ K^-$ and $D^0\to \pi^+\pi^-$ decays collected in $p\bar{p}$ collisions by the Collider Detector at Fermilab experiment. The full CDF data set corresponding to $9.7$ fb$^{-1}$ of integrated luminosity is used. The flavor of the charm meson at production is determined by exploiting the strong-interaction decay $D^{*+} \to D^0 \pi^+$, while the contamination from mesons originated in $b$-hadron decays is evaluated and subtracted from the sample. Signal yields as functions of the observed decay-time distributions are extracted from maximum likelihood fits and used to measure the asymmetries. The results, $A_\Gamma (K^+K^-) = \bigl(-1.9 \pm 1.5 \mathrm{(stat)} \pm 0.4 \mathrm{(syst)} \bigr)\times10^{-3}$ and $A_\Gamma (\pi^+\pi^-)= \bigl(-0.1 \pm 1.8 \mathrm{(stat)} \pm 0.3 \mathrm{(syst)} \bigr)\times10^{-3}$, and their combination, $A_\Gamma = \bigl(-1.2 \pm 1.2\bigr)\times10^{-3}$, are consistent with the SM predictions and other experimental determinations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incomplete Data in Smart Grid: Treatment of Values in Electric Vehicle Charging Data

In this paper, five imputation methods namely Constant (zero), Mean, Median, Maximum Likelihood, and Multiple Imputation methods have been applied to compensate for missing values in Electric Vehicle (EV) charging data. The outcome of each of these methods have been used as the input to a prediction algorithm to forecast the EV load in the next 24 hours at each individual outlet. The data is real world data at the outlet level from the UCLA campus parking lots. Given the sparsity of the data, both Median and Constant (=zero) imputations improved the prediction results. Since in most missing value cases in our database, all values of that instance are missing, the multivariate imputation methods did not improve the results significantly compared to univariate approaches.

Majipour, Mostafa↗

Random mask optimization for fast neutron coded aperture imaging

In coded aperture imaging, one of the most important factors determining the quality of reconstructed images is the choice of mask/aperture pattern. In many applications, uniformly redundant arrays (URAs) are widely accepted as the optimal mask pattern. Under ideal conditions, thin and highly opaque masks, URA patterns are mathematically constructed to provide artifact-free reconstruction however, the number of URAs for a chosen number of mask elements is limited and when highly penetrating particles such as fast neutrons and high-energy gamma-rays are being imaged, the optimum is seldom achieved. In this case more robust mask patterns that provide better reconstructed image quality may exist. Through the use of heuristic optimization methods and maximum likelihood expectation maximization (MLEM) image reconstruction, we show that for both point and extended neutron sources a random mask pattern can be optimized to provide better image quality than that of a URA.

McMillan, Kyle↗

ANNIE Phase II Reconstruction Techniques

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton Gd-doped water Cherenkov detector installed in the Booster Neutrino Beam at Fermilab. The experiment has two complementary goals: (1) perform the first measurement of the neutron yield from $\nu_{\mu}$ interactions as a function of Q$^2$ in order to constrain neutrino-nucleus interaction theoretical models, and (2) demonstrate the power of new fast-timing, position-sensitive detectors by making the first deployment of Large Area Picosecond PhotoDetectors (LAPPDs) in a physics experiment. In Phase I, ANNIE successfully performed neutron background measurements. To realise the Phase II measurements the ANNIE collaboration has developed several reconstruction techniques using the arrival time and position of the Cherenkov photons in the detector photomultipliers (PMTs) and LAPPDs. A maximum-likelihood fit is used to reconstruct the neutrino interaction vertex and direction. Machine and Deep Learning techniques are used for the muon and neutrino energy reconstruction. We present the results of ANNIE reconstruction techniques and the improvement we can get in resolution with the use of LAPPDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Spectroscopy

Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal vs. background discrimination and spectral capability, but suffer from poor sensitivity due to geometrical constraints. This weakness can be overcome if both neutron-proton scattering interactions are detected and resolved within one large contiguous active detector volume. We describe here a maximum likelihood approach to event reconstruction in a single-volume system with no optical segmentation and sensitivity to individual optical photons on the surfaces of the scintillator. We present results from a Geant4-based simulation establishing the feasibility of this single-volume neutron scatter camera concept given notional performance of existing photodetector and readout technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DeepCMB: Lensing Reconstruction of the CMB with Deep Neural Networks

Next-generation cosmic microwave background (CMB) experiments will have lower noise and therefore increased sensitivity, enabling improved constraints on fundamental physics parameters such as the sum of neutrino masses and the tensor-to-scalar ratio r. Achieving competitive constraints on these parameters requires high signal-to-noise extraction of the projected gravitational potential from the CMB maps. Standard methods for reconstructing the lensing potential employ the quadratic estimator (QE). However, the QE performs suboptimally at the low noise levels expected in upcoming experiments. Other methods, like maximum likelihood estimators (MLE), are under active development. In this work, we demonstrate reconstruction of the CMB lensing potential with deep convolutional neural networks (CNN) - ie, a ResUNet. The network is trained and tested on simulated data, and otherwise has no physical parametrization related to the physical processes of the CMB and gravitati onal lensing. We show that, over a wide range of angular scales, ResUNets recover the input gravitational potential with a higher signal-to-noise ratio than the QE method, reaching levels comparable to analytic approximations of MLE methods. We demonstrate that the network outputs quantifiably different lensing maps when given input CMB maps generated with different cosmologies. We also show we can use the reconstructed lensing map for cosmological parameter estimation. This application of CNN provides a few innovations at the intersection of cosmology and machine learning. First, while training and regressing on images, we predict a continuous-variable field rather than discrete classes. Second, we are able to establish uncertainty measures for the network output that are analogous to standard methods. We expect this approach to excel in capturing hard-to-model non-Gaussian astrophysical foreground and noise contributions.

79 ASTRONOMY AND ASTROPHYSICS↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testing multiflavored ULDM models with SPARC

We perform maximum likelihood estimates (MLEs) for single and double flavor ultralight dark matter (ULDM) models using the Spitzer Photometry and Accurate Rotation Curves (SPARC) database. These estimates are compared to MLEs for several commonly used cold dark matter (CDM) models. By comparing various CDM models we find, in agreement with previous studies, that the Burkert and Einasto models tend to perform better than other commonly used CDM models. We focus on comparisons between the Einasto and ULDM models and analyze cases for which the ULDM particle masses are: free to vary; and fixed. For each of these analyses, we perform fits assuming the soliton and halo profiles are: summed together; and matched at a given radius. When we let the particle masses vary, we find a negligible preference for any particular range of particle masses, within $10^{-25}\,\text{eV}\leq m\leq10^{-19}\,\text{eV}$, when assuming the summed models. For the matched models, however, we find that almost all galaxies prefer particles masses in the range $10^{-23}\,\text{eV}\lesssim m\lesssim10^{-20}\,\text{eV}$. For both double flavor models we find that most galaxies prefer approximately equal particle masses. We find that the summed models give much larger variances with respect to the soliton-halo (SH) relation than the matched models. When the particle masses are fixed, the matched models give median and mean soliton and halo values that fall within the SH relation bounds, for most masses scanned. When the particle masses are fixed in the fitting procedure, we find the best fit results for the particle mass $m=10^{-20.5}\,\text{eV}$ (for the single flavor models) and $m_1=10^{-20.5}\,\text{eV}$, $m_2=10^{-20.2}\,\text{eV}$ for the double flavor, matched model. We discuss how our study will be furthered using a reinforcement learning algorithm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Unpolarised p+p¿ Photoproduction with the GlueX Experiment

This thesis presents measurements of spin-density matrix elements in unpolarised p+p? photoproduction on a proton target. The dominant resonance contribution to the dipion system is the r(770) meson. Due to the large production cross section for this resonance, a valid comparison can be made between the obtained final results and r(770) spin-density matrix elements measured previously with other experiments. The measurement was performed over the 3:0 ? 11:6 GeV beam energy regime, which is a more extensive energy range than has ever been studied previously for the r(770). Results were obtained by analysing data from the GlueX experiment based at Jefferson Lab. Extended maximum likelihood fits were applied to extract three spin-density matrix elements using Markov chain Monte Carlo based parameter estimations. This was performed using various binning configurations to probe the energy, mass, and four-momentum transfer dependence of the determined physics observables. Spin-density matrix elements are shown to be consistent with the model of s-channel helicity conservation at low ?t. The effects of pomeron and f2 exchanges are clearly visible in the energy dependence of the measured observables. These observations provide valuable insights into the relative strengths of both processes as a function of the photon energy, and may enable theorists to disentangle the f2=P coupling ratio. Spin-density matrix elements are seen to be highly dependent on the reconstructed resonance mass. This observation is likely to be a result of non-resonant S-wave background processes, and emphasises the need for a more detailed model of the p+p? angular distribution that considers all of the competing angular momentum components that contribute to the measured final state. The statistical precision of measurements performed for this thesis surpass what was achievable in previous studies of the r(770) by several orders of magnitude. Studies of the energy and four-momentum transfer dependence, and insights into the effects of non r(770) background contributions provide valuable input for production models. This will help inform the choice of wave-sets used for partial wave analyses, supporting GlueX in its search for exotic hybrid meson states.

Fitches, James↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

First Measurements of the ρ1, ρ2, and ρ3 Spin Density Matrix Elements in γp→pω using CLAS at JLab

In an effort towards a ``complete'' experiment for the $\omega$ meson, we present studies from two experiments with unpolarized targets, one using a circularly polarized photon beam (g1c) and one using a linearly polarized photon beam (g8b), both carried out using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. The experiments were analyzed using an extended maximum likelihood fit to the cross section with partial wave amplitudes. New likelihood functions were calculated to account for the polarization of the photon beams. The results of these fits are then used to project out the spin density matrix for the $\omega$. First measurements of the $\rho^1$, $\rho^2$, and $\rho^3$ spin density matrix elements will be presented using this method. As a check, we compare to another method, Schilling's method, which fits the decay angular distribution with a function that uses the spin density matrix elements as parameters.

Vernarsky, Brian↗