Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Error Reduction Methods for Integrated-path Differential-absorption Lidar Measurements

We report new modeling and error reduction methods for differential-absorption optical-depth (DAOD) measurements of atmospheric constituents using direct-detection integrated-path differential-absorption lidars. Errors from laser frequency noise are quantified in terms of the line center fluctuation and spectral line shape of the laser pulses, revealing relationships verified experimentally. A significant DAOD bias is removed by introducing a correction factor. Errors from surface height and reflectance variations can be reduced to tolerable levels by incorporating altimetry knowledge and "log after averaging", or by pointing the laser and receiver to a fixed surface spot during each wavelength cycle to shorten the time of "averaging before log".

averging before log↗

DESI DR2 Galaxy luminosity functions

We present galaxy luminosity functions (LFs) for the Dark Energy Spectroscopic Instrument (DESI) DR2 Bright Galaxy Survey (BGS) in the g, r, z, and $w1$ bands over $0.002\lt z\lt 0.6$. Our analysis uses updated k-corrections and evolutionary corrections, including new polynomial kcorrection fits derived from BGS Year 1 data that supersede earlier GAMA-based prescriptions. Exploiting the statistical power of DESI, we measure LFs to very faint magnitudes, reaching $^{0.1}M_r-5\log h\sim -10$. Independent measurements from the North and South survey regions show excellent agreement around the LF knee, but the very small statistical uncertainties reveal that simple analytic forms fail to capture the full LF shape. The bright end departs from a pure exponential decline, while the faint end exhibits complex, non-powerlaw behaviour, including a pronounced upturn at $^{0.1}M_r-5\log h\gtrsim -15$, which is stronger for red galaxies than for blue. We show that our LFs are largely complete for galaxies with surface brightness $\mu _{50}\lt 25$, and that an apparent steepening fainter than $-13$ is driven primarily by local overdensity and fragmentation of large galaxies. A systematic North–South offset at the brightest magnitudes is traced to red galaxies and may reflect shallower North photometry underestimating extended earlytype profiles, although this remains inconclusive. We therefore also provide LFs based on model Petrosian magnitudes. Redshift splitting reveals small but significant residuals, indicating limitations of a simple global evolutionary model. Using the redshift limits of J. Loveday et al. (2012), we find excellent agreement with GAMA, with substantially reduced statistical errors. These measurements provide a precise reference for studies of environmental and population-dependent LFs and for testing galaxy formation models.

79 ASTRONOMY AND ASTROPHYSICS↗

LCLS X-ray mirror measurements using a large aperture visible light interferometer

Synchrotron or FEL X-ray mirrors are required to deliver an X-ray beam from its source to an experiment location, without contributing significantly to wave front distortion. Accurate mirror figure measurements are required prior to installation to meet this intent. This paper describes how a 300 mm aperture phasing interferometer was calibrated to <1 nm absolute accuracy and used to mount and measure 450 mm long flats for the Linear Coherent Light Source (LCLS) at Stanford Linear Accelerator Center. Measuring focus mirrors with an interferometer requires additional calibration, because high fringe density introduces systematic errors from the interferometer's imaging optics. This paper describes how these errors can be measured and corrected. The calibration approaches described here apply equally well to interferometers larger than 300 mm aperture, which are becoming more common in optics laboratories. The objective of this effort was to install LCLS flats with < 10 nm of spherical curvature, and < 2 nm rms a-sphere. The objective was met by measuring the mirrors after fabrication, coating and mounting, using a 300 mm aperture phasing interferometer calibrated to an accuracy < 1 nm. The key to calibrating the interferometer accurately was to sample the error using independent geometries that are available. The results of those measurements helped identify and reduce calibration error sources. The approach used to measure flats applies equally well to focus mirrors, provided an additional calibration is performed to measure the error introduced by fringe density. This calibration has been performed on the 300 mm aperture interferometer, and the measurement correction was evaluated for a typical focus mirror. The 300 mm aperture limitation requires stitching figure measurements together for many X-ray mirrors of interest, introducing another possible error source. Stitching is eliminated by applying the calibrations described above to larger aperture instruments. The authors are presently extending this work to a 600 mm instrument. Instruments with 900 mm aperture are now becoming available, which would accommodate the largest mirrors of interest.

43 PARTICLE ACCELERATORS↗

Battery state of health monitoring by estimation of the number of cyclable Li-ions

Herein this paper introduces a method to monitor battery state of health (SOH) by estimating the number of cyclable Li-ions, a health-relevant electrochemical variable. SOH monitoring is critical to battery management in balancing the trade-off between maximizing system performance and minimizing battery degradation. The decrease of cyclable Li-ions indicates the effect on the SOH of degradation mechanisms that consume cyclable Li-ions. The unavailability of the number of cyclable Li-ions through non-invasive measurements makes its estimation necessary for in-situ SOH monitoring. In this paper, the extended Kalman filter (EKF) is used to estimate the number of cyclable Li-ions as an unknown battery parameter. The single particle model (SPM), a simplified battery electrochemical model, is used as the model in the EKF to achieve a computational complexity suitable for on-line estimation. Simulations are performed under typical electric vehicle current trajectories using an example parameter set for a hybrid-electric-vehicle battery. In the simulations, the battery is represented by the Doyle–Fuller–Newman (DFN) model, an electrochemical model with higher fidelity than the SPM. To comply with the practice, instead of using the same parameters as the DFN model in the SPM, parameterization of the SPM is performed before estimation of the number of cyclable Li-ions. The simulations show high estimation accuracy of the number of cyclable Li-ions using the EKF, even with the structural and parametric differences between the DFN model and the SPM, under both the ideal conditions and various non-ideal conditions (i.e., SOC estimation error, additional modeling error, and measurement noise).

25 ENERGY STORAGE↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linearization of Attitude-Control Error Dynamics

Direction cosines and quaternions are useful for representing rigid-body attitude because they exhibit no kinematic singularities. Each utilizes more variables than the minimum three degrees of freedom required to specify attitude. Therefore, application of a nonlinear inversion procedure to either formulation introduces singularities. Furthermore, in designing an attitude-control system, it is not appropriate to express attitude error as a difference of direction cosines (or quaternions). One should employ a measure of attitude error that not only is minimal but preserves orthogonal rotation properties as well. This note applies an inversion procedure to an appropriate measure of attitude error, so that the singularity occurs when the error reaches +/- 180 deg. This approach leads to the realization of a new model-follower attitude-control system that exhibits exact linear attitude-error dynamics.

Bach, Ralph↗

Pseudospectral calculation of the wave function of helium and the negative hydrogen ion

We study the numerical solution of the nonrelativistic Schroedinger equation for two-electron atoms in ground and excited S states using pseudospectral (PS) methods of calculation. The calculation achieves convergence rates for the energy, Cauchy error in the wave function, and variance in local energy that are exponentially fast for all practical purposes. The method requires three separate subdomains to handle the wave function's cusplike behavior near the two-particle coalescences. The use of three subdomains is essential to maintaining exponential convergence and is more computationally efficient than a single subdomain. A comparison of several different treatments of the cusps suggests that the simplest prescription is sufficient. We investigate two alternate methods for handling the semi-infinite domain, one which involves a sequence of truncated versions of the domain and the other which employs an algebraic mapping of the semi-infinite domain to a finite one and imposes no explicit cutoffs on the wave function. The latter prescription proves superior. For many purposes it proves unnecessary to handle the three-particle coalescence in a special way. The presence of logarithmic terms in the exact solution is expected to limit the convergence to being nonexponential but the only clear evidence of that is the rate of convergence of derivatives near the three-particle coalescence point. Higher resolution than achieved in this work will ultimately be needed to see its limiting effect on other measures of error. As developed and applied here the PS method has many virtues: no explicit assumptions need be made about the asymptotic behavior of the wave function near cusps or at large distances, the local energy (H{psi}/{psi}) is exactly equal to the calculated global energy at all collocation points, local errors go down everywhere with increasing resolution, the effective basis using Chebyshev polynomials is complete and simple, and the method is easily extensible to other bound states. As the number of collocation points grows, the method achieves exponential convergence up to the resolution tested. This study serves as a proof-of-principle of the method for more general two- and possibly three-electron applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the rate constants for the radical-radical reactions NH{sub 2}(X{sup 2}B{sub 1}) + NH(X{sup 3}{Sigma}{sup -}) and NH{sub 2}(X{sup 2}B{sub 1}) + H({sup 2}S{sub u}) at 293 K.

The rate constant for the reactions NH{sub 2}({sub x}{sup 2}B{sub 1}) + NH(X{sup 3}{Sigma}{sup -}) and NH{sub 2}({sub x}{sup 2}B{sub 1}) + H({sup 2}S) were measured over a pressure range from 2 to 10 Torr in CF{sub 4}, or Ar gases at 293 {+-} 2 K. The radicals were produced by the 193 nm photolysis of NH{sub 3} dilute in the carrier gas. Both radicals were monitored simultaneously following the photolysis laser pulse using high-resolution time-resolved absorption spectroscopy. The NH{sub 2} radical was monitored using the {sup 1}2{sub 21} {l_arrow} {sup 1}3{sub 31} rotational transition of the (0,7,0){sub A}{sup 2}A{sub 1} {l_arrow} (0,0,0) {sub x}{sup 2}B{sub 1} vibronic band near 675 nm, and the NH radical was monitored using the {sup 1}R{sub 3}(4) rotational transition on the 1?0 vibrational transition near 3084 nm. The data was analyzed using model simulations of the NH{sub 2} and NH temporal concentration profiles. The rate constants for the NH{sub 2} + NH and NH{sub 2} + H reactions were found to be (9.6 {+-} 3.2) x 10{sup -11} and (7.7 {+-} 14) x 10{sup -15} cm{sup 3} molecule{sup -1} s{sup -1}, respectively, where the uncertainty includes an estimate of both systematic and random errors. The measurements were independent of the nature of the diluents, CF{sub 4} or Ar, and total pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absorption of Solar Radiation by the Cloudy Atmosphere: Further Interpretations of Collocated Aircraft Measurements

We have extended the interpretations made in two prior studies of the aircraft shortwave radiation measurements that were obtained as part of the Atmospheric Radiation Measurements (ARM) Enhanced Shortwave Experiments (ARESE). These extended interpretations use the 500 nm (10 nm bandwidth) measurements to minimize sampling errors in the broadband measurements. It is indicated that the clouds present during this experiment absorb more shortwave radiation than predicted by clear skies and thus by theoretical models, that at least some (less than or equal to 20%) of this enhanced cloud absorption occurs at wavelengths less than 680 nm, and that the observed cloud absorption does not appear to be an artifact of sampling errors nor of instrument calibration errors.

Cess, R. D.↗

Encryption of Signal Pulses to Replace Tamper-indicating Conduit

In order to verify signal integrity and point of origin for TTL pulse data used in IAEA systems, and to avoid the need for expensive tamper-indicating conduit or electronic techniques, we propose the development of a signal pulse signing and encryption in-line device. In measurement applications in which the data acquisition electronics is separate from the enclosed, sealed detector, tamper-indicating techniques are required to protect raw TTL pulse streams between the detector and the data acquisition module, i.e UMSR. The goal of this proposed project is to design a rad-tolerant transmitter that would mount inside the sealed detector system and a receiver in the sealed electronics cabinet with the data acquisition instrument. This transmitter/receiver pair would digitally sign and encrypt the pulse stream data at the detector then transmit the data to the sealed cabinet where the receiver would decrypt the data and reproduce the original pulse stream. Existing tamper indicating techniques, such as LiveWire’s spread spectrum time domain reflectometry rely on detecting physical changes to the wiring system and can be blind to fast coupling of micro-second wide pulses. Digital signing and encryption techniques such as the Sandia Laboratories Enhanced Data Authentication System (EDAS) are capable of encrypting communications data, i.e. RS-232, but are not capable reproducing a critical time correlated data streams. Recent NA-241 Safeguards Technology supported developments have reduced the need for special conduit to transmit data via Ethernet by incorporating the IAEA RAINSTORM data encryption and authentication protocol, a tamper indicator is still required to protect raw pulse data from detectors to the acquisition electronics. Encrypting pulse data is especially complicated for radiation detection instruments due to the time correlation data analysis that is performed on this data stream. Any corruption in the timing information will produce errors in measurement values.

97 MATHEMATICS AND COMPUTING↗

Simulation of the earth's monthly average regional radiation balance derived from satellite measurements

Computer simulations of satellite-derived earth radiation parameters are used to determine the source and size of errors arising from measuring parameters over 1 month on a 2.5 deg x 2.5 deg longitude-latitude grid. November 1979 GOES data are used as a source of radiation parameter fields within each region. A mathematical model is given for the data-processing algorithms that are used to produce daily, monthly, and monthly hourly estimates of shortwave, longwave and net radiant exitance. Resulting retrieval errors are found to be due to insufficient knowledge of the temporal distribution of measurements. These errors, in combination with similar sampling errors produce biases in monthly net radiant exitance which are complex, regionally-dependent functions of the local time of the measurements. The 40 region standard errors of estimate for three satellites ranged from 2 to 3 W per sq. m., while single satellite errors ranged from 5 to 19 W per sq. m. A three-satellite system is therefore recommended to reduce biases.

Brooks, D. R.↗

Actuated Hybrid Mirror Telescope

The figure depicts the planned Actuated Hybrid Mirror Telescope (AHMT), which is intended to demonstrate a new approach to the design and construction of wide-aperture spaceborne telescopes for astronomy and Earth science. This technology is also appropriate for Earth-based telescopes. The new approach can be broadly summarized as using advanced lightweight mirrors that can be manufactured rapidly at relatively low cost. More specifically, it is planned to use precise replicated metallic nanolaminate mirrors to obtain the required high-quality optical finishes. Lightweight, dimensionally stable silicon carbide (SiC) structures will support the nanolaminate mirrors in the required surface figures. To enable diffraction- limited telescope performance, errors in surface figures will be corrected by use of mirror-shape-control actuators that will be energized, as needed, by a wave-front-sensing and control system. The concepts of nanolaminate materials and mirrors made from nanolaminate materials were discussed in several previous NASA Tech Briefs articles. Nanolaminates constitute a relatively new class of materials that can approach theoretical limits of stiffness and strength. Nanolaminate mirrors are synthesized by magnetron sputter deposition of metallic alloys and/or compounds on optically precise master surfaces to obtain optical-quality reflector surfaces backed by thin shell structures. As an integral part of the deposition process, a layer of gold that will constitute the reflective surface layer is deposited first, eliminating the need for a subsequent and separate reflective-coating process. The crystallographic textures of the nanolaminate will be controlled to optimize the performance of the mirror. The entire deposition process for making a nanolaminate mirror takes less than 100 hours, regardless of the mirror diameter. Each nanolaminate mirror will be bonded to its lightweight SiC supporting structure. The lightweight nanolaminate mirrors and SiC supporting structures will be fabricated from reusable master molds. The mirror-shape-control actuators will be low-power, high-capacitance lead magnesium niobate electrostrictive actuators that will be embedded in the SiC structures. The mode of operation of these actuators will be such that once power was applied, they will change in length and once power was removed, they will maintain dimensional stability to nanometer precision. This mode of operation will enable the use of low-power, minimally complex electronic control circuitry. The wave-front-sensing and control system will be designed and built according to a two-stage architecture. The first stage will be implemented by a Shack- Hartmann (SH) sensor subsystem, which will provide a large capture range. The second, higher-performance stage will be implemented by an image-based wave-front-sensing subsystem that will include a phase-retrieval camera (PRC), and will utilize phase retrieval and other techniques to measure wavefront error directly. Phase retrieval is a process in which multiple images of an unresolved object are iterated to estimate the phase of the optical system that acquired the images. The combination of SH and phase-retrieval sensors will afford the virtues of both a dynamic range of 105 and an accuracy of <10 nm.

Hickey, Gregory↗

Tracking and Data Relay Satellite (TDRS) tracking and orbit determination

Analysis results were derived using the Goddard Trajectory Determination System to determine the orbit of TDRS-East. A batch weighted least-squares algorithm is used to fit the Bilateration Ranging Transponder system tracking measurements. Six state parameters (position and velocity components) and the solar radiation pressure coefficient are estimated. The solutions are obtained by fitting the data over 34 hr arcs that overlap by 10 hr. Ephemerides are generated over the 34 hr arcs and then compared over the overlapping regions. The position differences indicate the consistency of the solutions and give a measure of their accuracy. The effect of the modeling of perturbative forces (solar radiation pressure, nonspherical geopotential field) on these results are studied. Error analysis is performed using the ORAN program to estimate the effect of force-model errors and measurement-related errors on the TDRS-East ephemeris.

Teles, J.↗

Aggregation of Leslie matrix models with application to ten diverse animal species

Some grouping is necessary when constructing a Leslie matrix model because it involves discretizing a continuous process of births and deaths. Here, the level of grouping is determined by the number of age classes and frequency of sampling. It is largely unknown what is lost or gained by using fewer age classes, and I address this question using aggregation theory. I derive an aggregator for a Leslie matrix model using weighted least squares, determine what properties an aggregated matrix inherits from the original matrix, evaluate aggregation error, and measure the influence of aggregation on asymptotic and transient behaviors. To gauge transient dynamics, I employ reactivity of the standardized Leslie matrix. I apply the aggregator to 10 Leslie models developed for animal populations drawn from a diverse set of species. Several properties are inherited by the aggregated matrix: (a) it is a Leslie matrix; (b) it is irreducible whenever the original matrix is irreducible; (c) it is primitive whenever the original matrix is primitive; and (d) its stable population growth rate and stable age distribution are consistent with those of the original matrix if the least squares weights are equal to the original stable age distribution. In the application, depending on the population modeled, when the least squares weights do not follow the stable age distribution, the stable population growth rate of the aggregated matrix may or may not be approximately consistent with that of the original matrix. Transient behavior is lost with high aggregation.

54 ENVIRONMENTAL SCIENCES↗

Electroweak observables in neutrino-electron scattering from a muon storage ring

We investigate the sensitivity of a companion neutrino detector situated in the plane of a high-energy, high-intensity muon storage ring to elastic ν μ and ν e scattering on electrons (EνES). Assuming a muon collider with center-of-mass energies of up to 10 TeV, we report sensitivity to the weak couplings g V and g A up to around 0.05% relative error, and sensitivity to the weak mixing angle in the momentum transfer Q ∈ [10 −2 , 2] GeV range up to around 0.03% relative error. EνES measurements with high-energy muon storage rings allow one to directly interrogate the momentum-transfer regime associated with the NuTeV anomaly. This level of precision allows unique sensitivity to the momentum-dependence of sin 2 θ W . We estimate that with the neutrinos from a E μ = 1.5 TeV (or higher) muon collider, the hypothesis that sin 2 θ W does not “run” can be safely ruled out.

electroweak precision physics↗

Determination of the Thermodynamic Properties of the Cyclohexane + n-Octane + n-Hexadecane Liquid Mixture by the Acoustic Method

The propagation of sound in the ternary cyclohexane + n-octane + n-hexadecane mixture at temperatures of 298–433 K and pressures of 0.1–100.1 MPa was investigated experimentally. The maximum error in measuring the velocity of sound in this mixture was 0.1%. Experimental data on the velocity of sound in such a mixture were obtained for the first time. On the basis of these data, the density, the isobaric expansion coefficient, the isobaric and isochoric heat capacities, and the isothermal compressibility of the indicated ternary mixture of three compositions at a temperature of 298–348 K and a pressure of 0.1–100 MPa and the deviation of the velocity of sound in it from the ideal one were determined. With the use of a number of semiempirical equations, the deviation of the velocity of sound in this mixture from the ideal one was estimated on the basis of the data on the velocity of sound in its pure components and in their binary compounds. A good agreement between the calculation and experimental data has been obtained. A table of the thermodynamic properties of the cyclohexane + n-octane + n-hexadecane mixture is presented.

42 ENGINEERING↗

On Feedback-Principle Control for Systems with Aftereffect Under Incomplete Phase-Coordinate Data

For a nonlinear system of differential equations with aftereffect, two mutually complement game minimax (maximin) problems for the quality functional are considered. Assuming that a part of phase coordinates of the system is measured (with error) sufficiently frequently, we provide solving algorithms that are stable with respect to the information noise and computational errors. The proposed algorithms are based on the Krasovskii extremal translation principle.

97 MATHEMATICS AND COMPUTING↗

Acquisition of Real-Time Operation Analytics for an Automated Serial Sectioning System

Mechanical serial sectioning is a highly repetitive technique employed in metallography for the rendering of 3D reconstructions of microstructure. While alternate techniques such as ultrasonic detection, micro-computed tomography, and focused ion beam milling have progressed much in recent years, few alternatives provide equivalent opportunities for comparatively high resolutions over significantly sized cross-sectional areas and volumes. To that end, the introduction of automated serial sectioning systems has greatly heightened repeatability and increased data collection rates while diminishing opportunity for mishandling and other user-introduced errors. Unfortunately, even among current, state-of-the-art automated serial sectioning systems, challenges in data collection have not been fully eradicated. Therefore, this paper highlights two specific advances to assist in this area; a non-contact laser triangulation method for assessment of material removal rates and a newly developed graphical user interface providing real-time monitoring of experimental progress. Furthermore, both are shown to be helpful in the rapid identification of anomalies and interruptions, while also providing comparable and less error-prone measures of removal rate over the course of these long-term, challenging, and innately destructive characterization experiments.

36 MATERIALS SCIENCE↗