Search NASA⌕ Search

SEARCH · Search NASA

Results for “process analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

PreDatA - Preparatory Data Analytics on Peta-Scale Machines

Peta-scale scientific applications running on High End Computing (HEC) platforms can generate large volumes of data. For high performance storage and in order to be useful to science end users, such data must be organized in its layout, indexed, sorted, and otherwise manipulated for subsequent data presentation, visualization, and detailed analysis. In addition, scientists desire to gain insights into selected data characteristics 'hidden' or 'latent' in the massive datasets while data is being produced by simulations. PreDatA, short for Preparatory Data Analytics, is an approach for preparing and characterizing data while it is being produced by the large scale simulations running on peta-scale machines. By dedicating additional compute nodes on the peta-scale machine as staging nodes and staging simulation's output data through these nodes, PreDatA can exploit their computational power to perform selected data manipulations with lower latency than attainable by first moving data into file systems and storage. Such in-transit manipulations are supported by the PreDatA middleware through RDMA-based data movement to reduce write latency, application-specific operations on streaming data that are able to discover latent data characteristics, and appropriate data reorganization and metadata annotation to speed up subsequent data access. As a result, PreDatA enhances the scalability and flexibility of current I/O stack on HEC platforms and is useful for data pre-processing, runtime data analysis and inspection, as well as for data exchange between concurrently running simulation models. Performance evaluations with several production peta-scale applications on Oak Ridge National Laboratory's Leadership Computing Facility demonstrate the feasibility and advantages of the PreDatA approach.

99 GENERAL AND MISCELLANEOUS↗

Thermal conductivity of half-Heusler compounds from first-principles calculations

We demonstrate successful application of first-principles-based thermal conductivity calculation on half-Heusler compounds that are promising, environmentally friendly thermoelectric materials. Taking the case of a p -type half-Heusler structure, the harmonic and anharmonic interatomic force constants were obtained from a set of force-displacement data calculated by the density functional theory. Thermal conductivity was obtained by two different methods: (1) Boltzmann-Peierls formula with phonon relaxation times calculated by either Fermi's golden rule of three-phonon scattering processes or spectral analysis of molecular dynamics phase space trajectories and (2) Green-Kubo formula for heat current obtained by equilibrium molecular dynamics simulations. The calculated temperature dependence of thermal conductivity is in reasonable agreement with experiments. The method was extended to alloy crystals assuming the transferability of interatomic force constants. By having access to accurate phonon-dependent transport properties, the contribution from an arbitral subset of phonon modes can be quantified. Furthermore, this helps understanding the influence of nanostructures on thermal conductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parametric Reconstruction of Glass Fiber-reinforced Polymer Composites from X-ray Projection Data—A Simulation Study

We present a new approach to estimate geometry parameters of glass fibers in glass fiber-reinforced polymers from simulated X-ray micro-computed tomography scans. Traditionally, these parameters are estimated using a multi-step procedure including image reconstruction, pre-processing, segmentation and analysis of features of interest. Each step in this chain introduces errors that propagate through the pipeline and impair the accuracy of the estimated parameters. In the approach presented in this paper, we reconstruct volumes from a low number of projection angles using an iterative reconstruction technique and then estimate position, direction and length of the contained fibers incorporating a priori knowledge about their shape, modeled as a geometric representation, which is then optimized. Using simulation experiments, we show that our method can estimate those representations even in presence of noisy data and only very few projection angles available.

42 ENGINEERING↗

Wet-chemical etching of FIB lift-out TEM lamellae for damage-free analysis of 3-D nanostructures

Reducing ion beam damage from the focused ion beam (FIB) during fabrication of cross sections is a well-known challenge for materials characterization, especially cross sectional characterization of nanostructures. To address this, a new method has been developed for cross section fabrication enabling high resolution transmission electron microscopy (TEM) analysis of 3-D nanostructures free of surrounding material and free of damage detectable by TEM analysis. Before FIB processing, nanopillars are encapsulated in a sacrificial oxide which acts as a protective layer during FIB milling. Furthermore, the cross sectional TEM lamella containing the nanopillars is then mounted and thinned with some modifications to conventional FIB sample preparation that provide stability for the lamella during the following wet-chemical dip etch. The wet-chemical etch of the TEM lamella removes the sacrificial oxide layer, freeing the nanopillars from any material that would obscure TEM imaging. Both high resolution TEM and aberration corrected scanning TEM images of Si/SiGe pillars with diameters down to 30 nm demonstrate the successful application of this approach.

3-d nanostructure analysis↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

3D printing of packaging inserts from biomass-fungi composites: Environmental sustainability analysis

In this study, a comprehensive Life cycle assessment (LCA) is conducted on molded packaging inserts from expanded polystyrene (EPS) foam, molded packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the low mix / high volume (LMHV) scenario and molded and machined packaging inserts from EPS foam, molded and machined packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the high mix / low volume (HMLV) scenario. Six environmental impact categories—climate change, acidification, eutrophication, fossil resource scarcity, land use, and water consumption—are analyzed to evaluate the environmental trade-offs associated with each type of packaging inserts. Under the LMHV scenario, molded packaging inserts from biomass-fungi composite emerge as the best option due to their lower impact on climate change, acidification and water consumption compared to other types of packaging inserts. Conversely, molded packaging inserts from biomass-fungi composite face challenges in land use and eutrophication, primarily due to raw material production. LCA also reveals that 3D-printed packaging inserts from biomass-fungi composite are the most environmentally favorable option under the HMLV scenario, due to significantly lower contributions to climate change, eutrophication, and water consumption compared to other types of packaging inserts. Conversely, 3D-printed packaging inserts from biomass-fungi composite face challenges in acidification and land use, primarily due to raw material production. As part of the LCA, sensitivity analyses show that sourcing energy from 100% renewable sources substantially lowers climate change impacts across all packaging types, while varying transportation distances results in only minor changes, indicating the dominant role of upstream material and manufacturing processes. Additional sensitivity analysis is conducted under the HMLV scenario to assess the impact of material removal during machining on the environment. The amount of material removal is varied from 10 to 70% for the sensitivity analysis and it highlights that the amount of material removed during machining has no significant impact on climate change for packaging inserts from EPS foam. However, molded and machined packaging inserts from biomass-fungi composite show an increasing trend in climate change with higher amount of material removal, while 3D-printed packaging inserts from biomass-fungi composite exhibit a decreasing trend, driven by reduced raw material usage and energy consumption.

09 BIOMASS FUELS↗

Coal-based Bricks & Blocks (CBBs): Process Development to Prototype Fabrication Coupled with Techno-Economic Analysis and Market Survey

Coal-based bricks and blocks (CBBs) were formulated using anthracite and thermoplastic binder. Lab scale test composites were formed by hot-press molding and commercial extrusion for test articles and for a full-scale prototype. Formulations and test matrices followed a systematic experimental design to examine the effects of and interactions among three primary independent variables: a) thermoplastic type, b) weight fractions of binder relative to the total anthracite weight, and c) relative proportions of large versus small (milled) anthracite size fractions. Technical performance metrics include compressive strength, modulus, porosity/permeability and density. These DoE studies establish composition-property relations and identify the best combination for any desired property of interest – in particular, strength. Based on CBB composition and fabrication process, validated against technical performance metrics, a techno-economic analysis was constructed which incorporated a process flow model, engineering design (with scaling), and calculated capital plus operating costs. Based on measured property metrics and estimated process economics and a projected price by TEA (techno-economic analysis), building and construction target markets were identified by a market survey assessment. With known cost, price, performance metrics and competitive advantages for CBBs matched with commercial applications/uses, a technical gap analysis was performed to identify further development required for scale-up and commercialization.

01 COAL, LIGNITE, AND PEAT↗

New Directions: GEIA’s 2020 Vision for Better Air Emissions Information

We are witnessing a crucial change in how we quantify and understand emissions of greenhouse gases and air pollutants, with an increasing demand for science-based transparent emissions information produced by robust community efforts. Today’s scientific capabilities, with near-real-time in-situ and remote sensing observations combined with forward and inverse models and a better understanding of the controlling processes, are contributing to this transformation and providing new approaches to derive, verify, and forecast emissions (Tong et al., 2011; Frost et al., 2012) and to quantify their impacts on the environment (e.g., Bond et al., 2013). At the same time, the needs for emissions information and the demands for their accuracy and consistency have grown. Changing economies, demographics, agricultural practices, and energy sources, along with mandates to evaluate emissions mitigation efforts, demonstrate compliance with legislation, and verify treaties, are leading to new challenges in emissions understanding. To quote NOAA Senior Technical Scientist David Fahey, "We are in the Century of Accountability. Emissions information is critical not only for environmental science and decision-making, but also as an instrument of foreign policy and international diplomacy." Emissions quantification represents a key step in explaining observed variability and trends in atmospheric composition and in attributing these observed changes to their causes. Accurate emissions data are necessary to identify feasible controls that reduce adverse impacts associated with air quality and climate and to track the success of implemented policies. To progress further, the international community must improve the understanding of drivers and contributing factors to emissions, and it must strengthen connections among and within different scientific disciplines that characterize our environment and entities that protect the environment and influence further emissions. The Global Emissions InitiAtive, GEIA (http://www.geiacenter.org/), is a center for emissions information exchange and competence building created in 1990 in response to the need for high quality global emissions data (Graedel et al., 1993). While the past two decades have seen considerable progress in developing, improving and assessing emission estimates, emissions continue to be a major contributor to overall uncertainty in atmospheric model simulations. Moving forward, GEIA aims to help build emissions knowledge in a rapidly evolving society by: 1) enhancing understanding, quantification, and analysis of emissions processes; 2) improving access to emissions information; and 3) strengthening the community of emissions groups involved in research, assessment, operations, regulation and policy.

Frost, G. J.↗

Next generation solvent performance in the modular caustic side solvent extraction process - 15495

Changes to the Modular Caustic Side Solvent Extraction Unit (MCU) flow-sheet were implemented in the facility. Implementation included changing the scrub and strip chemicals and concentrations, modifying the O/A ratios for the strip, scrub, and extraction contactor banks, and blending the current BoBCalixC6 extractant based solvent in MCU with clean MaxCalix extractant based solvent. During the successful demonstration period, the MCU process was subject to rigorous oversight to ensure hydraulic stability and chemical/radionuclide analysis of the key process tanks (caustic wash tank, solvent hold tank, strip effluent hold tank, and decontaminated salt solution hold tank) to evaluate solvent carryover to downstream facilities and the effectiveness of cesium removal from the liquid salt waste. Results indicated the extraction of cesium was significantly more effective with an average Decontamination Factor (DF) of 1,129 (range was 107 to 1,824) and that stripping was effective. The contactor hydraulic performance was stable and satisfactory, as indicated by contactor vibration, contactor rotational speed, and flow stability; all of which remained at or near target values. Furthermore, the Solvent Hold Tank (SHT) level and specific gravity was as expected, indicating that solvent integrity and organic hydraulic stability were maintained. The coalescer performances were in the range of processing results under the BOBCalixC6 flow sheet, indicating negligible adverse impact of NGS deployment. After the Demonstration period, MCU began processing via routine operations. Results to date reiterate the enhanced cesium extraction and stripping capability of the Next Generation Solvent (NGS) flow sheet. This paper presents process performance results of the NGS Demonstration and continued operations of MCU utilizing the blended BobCalixC6-MaxCalix solvent under the NGS flowsheet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fourier Transform Infrared Spectroscopy and Multivariate Analysis for Online Monitoring of Dibutyl Phosphate Degradation Product in Tributyl Phosphate/n-Dodecane/Nitric Acid Solvent

In liquid–liquid extraction separation processes, accumulation of organic solvent degradation products is detrimental to the process robustness, and frequent solvent analysis is warranted. Our research explores the feasibility of online monitoring of the organic solvents relevant to used nuclear fuel reprocessing. This paper describes the first phase of developing a system for monitoring the tributyl phosphate (TBP)/n-dodecane solvent commonly used to separate used nuclear fuel. In this investigation, the effect of extraction of nitric acid from aqueous solutions of variable concentrations on the quantification of TBP and its major degradation product dibutylphosphoric acid (HDBP) was assessed. Fourier transform infrared (FTIR) spectroscopy was used to discriminate between HDBP and TBP in the nitric acid-containing TBP/n-dodecane solvent. Multivariate analysis of the spectral data facilitated the development of regression models for HDBP and TBP quantification in real time, enabling online implementation of the monitoring system. The predictive regression models were validated using TBP/n-dodecane solvent samples subjected to high-dose external ?-irradiation. The predictive models were translated to flow conditions using a hollow fiber FTIR probe installed in a centrifugal contactor extraction apparatus, demonstrating the applicability of the FTIR technique coupled with multivariate analysis for the online monitoring of the organic solvent degradation products.

99 GENERAL AND MISCELLANEOUS↗

Zirconium nitride films deposited in (Ar + N{sub 2} + H{sub 2}) sputtering atmosphere: Optical, structural, and electrical properties

Zr-N films were grown on glass substrates via radio-frequency magnetron sputtering using an Ar + N{sub 2} + H{sub 2} mixture. Hydrogen was employed in order to reduce oxygen contamination coming from background pressure, as confirmed by secondary ion mass spectroscopy analysis. The tuned process parameter was the nitrogen flux percentage (R{sub N2}) in the mixture. The crystallographic structure of the films was studied using x-ray diffraction. The measurements show that the films deposited at low R{sub N2} (lower than or equal to 50%) crystallize in the rocksalt ZrN structure. As R{sub N2} exceeds 50%, the film exhibits the co-presence of ZrN and Zr{sub 3}N{sub 4} (denoted as o-Zr{sub 3}N{sub 4}) phases. When the deposition is performed in only nitrogen atmosphere (R{sub N2} = 100%), a broad peak located at 2{theta}{approx_equal} 32.2 deg. is mainly attributed to the contribution coming from (320) planes of the o-Zr{sub 3}N{sub 4}. An envelope method, based on the optical reflection and transmission spectra taken at normal incidence, has been applied for the optical characterization of the nitride films. Such a method allows the determination of the samples' average thickness and optical constants (refractive index n and extinction coefficient k) in the ultraviolet-visible-near infrared regions. The evaluated thickness was about 2500 nm, which is in good agreement with the value obtained from profilometry. The absorption coefficient {alpha} was calculated from reflectance and transmittance spectra. The energy bandgap ranges from 2.3 eV to 2.4 eV. Electrical characterization was performed using capacitance-voltage measurements, which showed that the films evolve from insulating to semiconductor behavior when the nitrogen content in the sputtering atmosphere is decreased, confirming structural and optical results.

36 MATERIALS SCIENCE↗

DOE site remedial management optimization utilizing on the cloud computing systems - 15676

Environmental cleanups at complex sites necessarily address many competing demands and answer questions such as: 'What is the best way and in a sustainable manner to minimize risk to human health and the environment during active restoration efforts and/or long term legacy management, while incorporating parameter uncertainty, management considerations, and stakeholder concerns into the process?' Physics Based Management Optimization (PBMO{sup TM}) provides a means to answer such questions. 'Physics Based' indicates incorporation of numerically computed groundwater flow and transport processes into the analysis. This enables optimal remedy design based on comprehensive mass removal/destruction metrics and optimal monitoring strategies. 'Management Optimization' indicates the ability to incorporate objective functions (e.g., management constraints, sustainability considerations) into the evaluation. PBMO{sup TM} components have been successfully implemented for optimal plume delineation (points of compliance) and monitoring, for optimal system design and to optimize existing active treatment systems in the US at multiple DOE, DOD and industrial sites since the mid 1990's. PBMO{sup TM} has been recently extended and implemented on multi-core, multi-CPU grid computing systems including computational clusters, local area networks and the Cloud. This extension allows for increased flexibility and adaptation of computational resources which can now support optimal remedy design and long term management strategies for complex soil and groundwater sites. In the PBMO{sup TM} -Grid case study, we evaluate flow and transport for a typical optimization search for a realistic project against sequential optimization. PBMO{sup TM}-Grid reduces the CPU time required to solve the optimization problem by more than a factor of 14 X compared to sequential optimization. PBMO{sup TM}-Grid can be deployed for deterministic or stochastic optimization and formally computes design risk and predicted degree of remedial action success. The numerical models used can consist of a single 'mega' model (aka a monolith), or a mixture of models and other calculations or expert systems. PBMO{sup T}M-Grid integrates the computational models in a seamless manner, and models run on the Cloud can be implemented in Windows or Linux platforms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Authorized limits for disposal of PCB capacitors from Buildings 361 and 391 at Argonne National Laboratory, Argonne, Illinois.

This report contains data and analyses to support the approval of authorized release limits for the clearance from radiological control of polychlorinated biphenyl (PCB) capacitors in Buildings 361 and 391 at Argonne National Laboratory, Argonne, Illinois. These capacitors contain PCB oil that must be treated and disposed of as hazardous waste under the Toxic Substances Control Act (TSCA). However, they had been located in radiological control areas where the potential for neutron activation existed; therefore, direct release of these capacitors to a commercial facility for PCB treatment and landfill disposal is not allowable unless authorized release has been approved. Radiological characterization found no loose contamination on the exterior surface of the PCB capacitors; gamma spectroscopy analysis also showed the radioactivity levels of the capacitors were either at or slightly above ambient background levels. As such, conservative assumptions were used to expedite the analyses conducted to evaluate the potential radiation exposures of workers and the general public resulting from authorized release of the capacitors; for example, the maximum averaged radioactivity levels measured for capacitors nearest to the beam lines were assumed for the entire batch of capacitors. This approach overestimated the total activity of individual radionuclide identified in radiological characterization by a factor ranging from 1.4 to 640. On the basis of this conservative assumption, the capacitors were assumed to be shipped from Argonne to the Clean Harbors facility, located in Deer Park, Texas, for incineration and disposal. The Clean Harbors facility is a state-permitted TSCA facility for treatment and disposal of hazardous materials. At this facility, the capacitors are to be shredded and incinerated with the resulting incineration residue buried in a nearby landfill owned by the company. A variety of receptors that have the potential of receiving radiation exposures were analyzed. Based on the dose assessment results, it is indicated that, if the disposition activities are completed within a year, the maximum individual dose would be about 0.021 mrem/yr, which is about 0.02% of the primary dose limit of 100 mrem/yr set by U.S. Department of Energy (DOE) for members of the public. The maximum individual dose was associated with a conservative and unlikely scenario involving a hypothetical farmer who intruded the landfill area to set up a subsistence living above the disposal area 30 years after burial of the incineration residue. Potential collective dose for worker and the general public combined was estimated to be less than 4 x 10{sup -4} person-rem/yr, about 0.004% of the DOE authorized release objective of 10 person-rem/yr for collective exposure. In reality, the actual radiation doses incurred by workers and the general public are expected to be at least two orders of magnitude lower than the estimated values. To follow the ALARA (as low as reasonably achievable) principle of reducing potential radiation exposures associated with authorized release of the PCB capacitors, a dose constraint of 1 mrem/yr, corresponding to a small fraction of the 25 mrem/yr limit set by DOE, was initially used as a reference to derive the authorized release limits. On the basis of the dose assessment results, the following authorized release limits are proposed - 0.6 pCi/g for Mn-54, 0.6 pCi/g for Na-22, 0.1 pCi/g for Co-57, and 2.3 pCi/g for Co-60, with a corresponding maximum individual dose of 0.21 mrem/yr. This maximum dose, about 0.2% of the DOE primary dose limit of 100 mrem/yr for members of the public from all sources and exposure pathways, was then selected as the final dose constraint for releasing the PCB capacitors through the authorized process. The proposed authorized release limits would satisfy the DOE requirements for the release of non-real properties to a commercial treatment and disposal facility. In addition, due to the relatively short half-lives (< 5.27 years) of radionuclides of concern, there will be no long-term buildup of doses either in groundwater or through other exposure pathways associated with this particular release action. Contact with Clean Harbors and the State of Texas has been initiated. The radioactivity levels in the PCB capacitors meet the State of Texas radiological exemption limits and would be accepted by Clean Harbors, subject to the approval by DOE for the authorized release process. Cost benefit analysis shows that authorized release of the PCB capacitors would provide significant cost saving over the low-level radioactive waste (LLRW) disposition alternative, i.e. sending the PCB capacitors to a certified LLRW facility for treatment and disposal, and would not cause a significantly different impact in terms of human health protection. Therefore, authorized release is determined to be the preferred alternative for the disposition of Argonne PCB capacitors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Covariance Applications in Criticality Safety, Light Water Reactor Analysis, and Spent Fuel Characterization

A new covariance data library based on ENDF/B-VII.1 was recently processed for the SCALE nuclear analysis code system. The multigroup covariance data are discussed here, along with testing and application results for critical benchmark experiments. The cross section covariance library, along with covariances for fission product yields and decay data, is used to compute uncertainties in the decay heat produced by a burned reactor fuel assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Behavioral and neuroinflammatory changes caused by glyphosate: Base herbicide in mice offspring

Abstract Background Glyphosate is a pesticide considered of low toxicity, but scientific evidences show it can be harmful to health. This study aimed to evaluate the toxicity in mice offspring exposed to glyphosate‐based herbicide (GBH) during the intrauterine period. Methods Female matrices received glyphosate 0.3 mg/kg daily per oral throughout the gestational period, which was variable between 18 and 22 days. From the 25th until the 28th days post‐birth, mice offspring were subjected to behavioral tests, and the prefrontal cortex was processed for immunohistochemical analysis. Results Two significant behavioral changes were observed: anxiety in the GLIF0.3 group, increase in the behavior burying marbles in the marble‐burying test and hyperactivity, expressed by the significant increase of the crossing number in the open field test. The increased microglia, TNF‐alpha, and astrocyte expression were also observed in the prefrontal cortex of offspring treated with GLIF0.3. Conclusion Exposure to GBH during mice intrauterine development induces hyperactive and anxious behavior, evidencing neuroinflammation.

de Castro Vieira Carneiro, Carla Larissa↗