Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Models used to assess the performance of photovoltaic systems.

This report documents the various photovoltaic (PV) performance models and software developed and utilized by researchers at Sandia National Laboratories (SNL) in support of the Photovoltaics and Grid Integration Department. In addition to PV performance models, hybrid system and battery storage models are discussed. A hybrid system using other distributed sources and energy storage can help reduce the variability inherent in PV generation, and due to the complexity of combining multiple generation sources and system loads, these models are invaluable for system design and optimization. Energy storage plays an important role in reducing PV intermittency and battery storage models are used to understand the best configurations and technologies to store PV generated electricity. Other researcher's models used by SNL are discussed including some widely known models that incorporate algorithms developed at SNL. There are other models included in the discussion that are not used by or were not adopted from SNL research but may provide some benefit to researchers working on PV array performance, hybrid system models and energy storage. The paper is organized into three sections to describe the different software models as applied to photovoltaic performance, hybrid systems, and battery storage. For each model, there is a description which includes where to find the model, whether it is currently maintained and any references that may be available. Modeling improvements underway at SNL include quantifying the uncertainty of individual system components, the overall uncertainty in modeled vs. measured results and modeling large PV systems. SNL is also conducting research into the overall reliability of PV systems.

14 SOLAR ENERGY↗

Microbial Extremophiles in Aspect of Limits of Life

During Earth's evolution accompanied by geophysical and climatic changes a number of ecosystems have been formed. These ecosystems differ by the broad variety of physicochemical and biological factors composing our environment. Traditionally, pH and salinity are considered as geochemical extremes, as opposed to the temperature, pressure and radiation that are referred to as physical extremes (Van den Burg, 2003). Life inhabits all possible places on Earth interacting with the environment and within itself (cross species relations). In nature it is very rare when an ecotope is inhabited by a single species. As a rule, most ecosystems contain the functionally related and evolutionarily adjusted communities (consortia and populations). In contrast to the multicellular structure of eukaryotes (tissues, organs, systems of organs, whole organism), the highest organized form of prokaryotic life in nature is the benthic colonization in biofilms and microbial mats. In these complex structures all microbial cells of different species are distributed in space and time according to their functions and to physicochemical gradients that allow more effective system support, self-protection, and energy distribution. In vitro, of course, the most primitive organized structure for bacterial and archaeal cultures is the colony, the size, shape, color, consistency, and other characteristics of which could carry varies specifics on species or subspecies levels. In table 1 all known types of microbial communities are shown (Pikuta et a]., 2005). In deep underground (lithospheric) and deep-sea ecosystems an additional factor - pressure, and irradiation - could also be included in the list of microbial communities. Currently the beststudied ecosystems are: human body (due to the medical importance), and fresh water and marine ecosystems (due to the reason of an environmental safety). For a long time, extremophiles were terra incognita, since the environments with aggressive parameters (compared to the human body temperature, pH, mineralization, and pressure) were considered a priori as a dead zone.

Pikuta, Elena V.↗

Development of neural network force fields for corrosion studies

To fully understand the chemistry and physics of corrosion, novel methods of simulation must be developed. One approach is designing machine learning (ML) algorithms integrated with density functional theory to develop adaptive force fields to gain insight into corrosion behavior namely at the surface of metal oxides. Current methods of modeling corrosion are slow due to the computational cost of resolving both reaction mechanics and mass transport processes. Machine learning methods can be implemented to obtain structure-activity relationships at both the molecular and bulk scale while still retaining the accuracy of density functional theory (DFT) and significantly decreasing the time needed for simulations of complex chemical processes in the various environments of corrosion. Multiscale models are needed for corrosion studies to fully understand its processes not only at the atomic length scale (chemical bonding, energies, and forces), but also at the nano and meso length scales (solid-state physics and material science processes). Current methods of study include DFT, molecular dynamics, and Monte Carlo. The limitation of DFT is that only a small number of atoms or molecules can be simulated at that level of theory. Density functional theory is used to study the electronic structure of atoms and molecules, and calculate the force component of each atom. However, these calculations are limited to about 1000 atoms. Custom periodic boundary conditions (PBC) can be used to describe the various environments and defects that affect the atomic forces to produce a large data set from which a training set can be derived. Machine learning can be utilized to overcome the barrier of modeling macroscopic and multi-scale processes from ab initio calculations through the development of adaptive force fields. Local environments determine the atomic forces of a given system, therefore adaptive force fields must be created to produce reliable quantum mechanical calculations. This can be achieved by developing a learning algorithm that uses the mapped atomic forces or fingerprint as an input to produce energies and magnetic moments as output. A systematic approach was used to begin to build a data set in order to accurately describe the atomic forces in various environments. In Figure 4 below, a simple PBC cell of Fe{sub 2}O{sub 3} was first optimized. A surface optimization was performed next, followed by a hydroxylated surface optimization. Once this calculation has converged, the adsorption of halide species to the hydroxylated surface will be investigated. TensorFlow is an open source platform for machine learning developed by Google. Using a high level application program interface (API) such as Keras allows for building and training ML models easily in a number of different environments and languages. For this project, a neural network was developed within Anaconda in Python. Future Work: Further development of reference data set; Refining neural network and learning algorithm; Fingerprinting atomic environment to enable mapping of atomic force components; Choosing appropriate training set from reference data; Learning from training set and enabling non-linear mapping of training set fingerprints and the atomic forces; Estimation of uncertainty to identify ranges of outside applicability; Testing and analysis of molecular dynamic simulations.

36 MATERIALS SCIENCE↗

Report on Project performance under the CRADA No PNNL/254, PLA 1, between BATTELLE as operator of Pacific Northwest National Laboratory under its U.S. Department of Energy Contract No. DE-AC05-76RL0 1830 and Isonics Corporation, Chairman and CEO: Christopher M. Toffales

Unattended decontamination of bio agents in enclosed environments. The goal of the project is the development of unattended method for environmentally safe, highly effective volumetric decontamination that kills on a contact multiple bio-agents including airborne and surface-adsorbed pathogens of different nature in enclosed environments with complex geometry like various buildings and transportation units as aircraft and ships The method employs two elements, proprietary Vortical Aerosol Generator (VAG) and Electrochemically Activated Solutions (EAS). The prototype of the method was developed under CRADA No PNNL/254, and was shown highly effective for irreversible decontamination of vegetative microbial cells, spores and viruses in a test chamber of ~100 ft 3 and in a room of ~3000 ft 3 . The electrochemical activation technology is based on the production of meta-stable (activated) solutions with anomalous physicochemical and catalytic reactivity for their further use in various technological processes in place of traditionally applied aggressive chemicals. Usual source for electrochemical activation processes is sodium chloride aqueous solution with the concentration of 1.0 g/L. EAS bactericidal effectiveness was previously demonstrated for different applications however, in all previous applications EAS was only used as a liquid agent. Present Method suggests an application of EAS as micro-aerosol (particle size in the range of 0.5-10 mµ), which behaves like a gas and eventually fills entire enclosed environment including hardly, not otherwise accessible sites. The term micro-aerosol of EAS (MAEAS) herein refers to an air-suspended EAS having micro-particle droplets of characteristic cross section and/or size comprising electrochemically-active agents with sufficiently large surface areas whereby the probability of a contact with bio agents in a process area is extremely high. EAS is produced with a commercially available STEL device (FEM-3 flow electrochemical module element; US Pat 5,635,040). Pneumatic Vortical Aerosol Generator (VAG) produces MAEAS. VAG is an original high output atomizer allowing for the production of the aerosol particles with the size in the range of 0.5 to 12 µm at the rate from 5 to 300 ml/min correspondingly, allowing a control of a required particle size. MAEAS has significant advantages over EAS, allowing for simultaneous decontamination of airborne and surface-adsorbed bio agents with minimal volume of atomized EAS and with essentially no waste. Experimental data indicate that MAEAS has very low corrosiveness, possess no negative effect to sensitive equipment and does not destroy the surface of different tested materials. Limited toxicity tests were conducted with mice directly exposed to EAS aerosol; no acute and short-term toxicity was identified.

bioagents↗

Guanidinium-Assisted Surface Matrix Engineering for Highly Efficient Perovskite Quantum Dot Photovoltaics

Metal halide perovskite quantum dots (Pe-QDs) are of great interest in new-generation photovoltaics (PVs). However, it remains challenging in the construction of conductive and intact Pe-QD films to maximize their functionality. Herein, a ligand-assisted surface matrix strategy to engineer the surface and packing states of Pe-QD solids is demonstrated by a mild thermal annealing treatment after ligand exchange processing (referred to as “LE-TA”) triggered by guanidinium thiocyanate. The “LE-TA” method induces the formation of surface matrix on CsPbI 3 QDs, which is dominated by the cationic guanidinium (GA+) rather than the SCN-, maintaining the intact cubic structure and facilitating interparticle electrical interaction of QD solids. Consequently, the GA-matrix-confined CsPbI 3 QDs exhibit remarkably enhanced charge mobility and carrier diffusion length compared to control ones, leading to a champion power conversion efficiency of 15.21% when assembled in PVs, which is one of the highest among all Pe-QD solar cells. Additionally, the “LE-TA” method shows similar effects when applied to other Pe-QD PV systems like CsPbBr 3 and FAPbI 3 (FA = formamidinium), indicating its versatility in regulating the surfaces of various Pe-QDs. This work may afford new guidelines to construct electrically conductive and structurally intact Pe-QD solids for efficient optoelectronic devices.

36 MATERIALS SCIENCE↗

Design and application of a kinetic model of lipid metabolism in Saccharomyces cerevisiae

Lipid biosynthesis plays a vital role in living cells and has been increasingly engineered to overproduce various lipid-based chemicals. However, owing to the tightly constrained and interconnected nature of lipid biosynthesis, both understanding and engineering of lipid metabolism remain challenging, even with the help of mathematical models. Here we report the development of a kinetic metabolic model of lipid metabolism in Saccharomyces cerevisiae that integrates fatty acid biosynthesis, glycerophospholipid metabolism, sphingolipid metabolism, storage lipids, lumped sterol synthesis, and the synthesis and transport of relevant target-chemicals, such as fatty acids and fatty alcohols. The model was trained on lipidomic data of a reference S. cerevisiae strain, single knockout mutants, and lipid overproduction strains reported in literature. The model was used to design mutants for fatty alcohol overproduction and the lipidomic analysis of the resultant mutant strains coupled with model-guided hypothesis led to discovery of a futile cycle in the triacylglycerol biosynthesis pathway. In addition, the model was used to explain successful and unsuccessful mutant designs in metabolic engineering literature. Thus, this kinetic model of lipid metabolism can not only enable the discovery of new phenomenon in lipid metabolism but also the engineering of mutant strains for overproduction of lipids.

59 BASIC BIOLOGICAL SCIENCES↗

Aerodynamic effect of a honeycomb rotor tip shroud on a 50.8-centimeter-tip-diameter core turbine

A 50.8-cm-tip-diameter turbine equipped with a rotor tip shroud of hexagonal cell (or honeycomb) cross section has been tested in warm air (416 K) for a range of shroud coolant to primary flow rates. Test results were also obtained for the same turbine operated with a solid shroud for comparison. The results showed that the combined effect of the honeycomb shroud and the coolant flow was to cause a reduction of 2.8 points in efficiency at design speed, pressure ratio, and coolant flow rate. With the coolant system inactivated, the honeycomb shroud caused a decrease in efficiency of 2.3 points. These results and those obtained from a small reference turbine indicate that the dominant factor governing honeycomb tip shroud loss is the ratio of honeycomb depth to blade span. The loss results of the two shrouds could be correlated on this basis. The same honeycomb and coolant effects are expected to occur for the hot (2200 K) version of this turbine.

Moffitt, T. P.↗

Radiation Budget Instrument (RBI) for JPSS-2

Radiation Budget Instrument (RBI) will be one of five instruments flying aboard the JPSS-2 spacecraft, a polar-orbiting sun-synchronous satellite in Low Earth Orbit. RBI is a passive remote sensing instrument that will follow the successful legacy of the Clouds and Earth's Radiant Energy System (CERES) instruments to make measurement of Earth's short and longwave radiation budget. The goal of RBI is to provide an independent measurement of the broadband reflected solar radiance and Earth's emitted thermal radiance by using three spectral bands (Shortwave, Longwave, and Total) that will have the same overlapped point spread function (PSF) footprint on Earth. To ensure precise NIST-traceable calibration in space the RBI sensor is designed to use a visible calibration target (VCT), a solar calibration target (SCT), and an infrared calibration target (ICT) containing phase change cells (PCC) to enable on-board temperature calibration. The VCT is a thermally controlled integrating sphere with space grade Spectralon covering the inner surface. Two sides of the sphere will have fiber-coupled laser diodes in the UV to IR wavelength region. An electrical substitution radiometer on the integrating sphere will monitor the long term stability of the sources and the possible degradation of the Spectralon in space. In addition the radiometric calibration operations will use the Spectralon diffusers of the SCT to provide accurate measurements of Solar degradation. All those stable on-orbit references will ensure that calibration stability is maintained over the RBI sensor lifetime. For the preflight calibration the RBI will view five calibration sources - two integrating spheres and three CrIS (Cross-track Infrared Sounder ) -like blackbodies whose outputs will be validated with NIST calibration approach. Thermopile are the selected detectors for the RBI. The sensor has a requirement to perform lunar calibration in addition to solar calibration in space in a way similar to CERES instruments approach. To monitor climate change and to get stable and traceable results, it is critical to assure stable calibration over instrument lifetime.

Georgieva, Elena↗

A modified Monte Carlo 'local importance function transform' method

The Local Importance Function Transform (LIFT) method uses an approximation of the contribution transport problem to bias a forward Monte-Carlo (MC) source-detector simulation [1-3]. Local (cell-based) biasing parameters are calculated from an inexpensive deterministic adjoint solution and used to modify the physics of the forward transport simulation. In this research, we have developed a new expression for the LIFT biasing parameter, which depends on a cell-average adjoint current to scalar flux (J{sup *}/{phi}{sup *}) ratio. This biasing parameter differs significantly from the original expression, which uses adjoint cell-edge scalar fluxes to construct a finite difference estimate of the flux derivative; the resulting biasing parameters exhibit spikes in magnitude at material discontinuities, causing the original LIFT method to lose efficiency in problems with high spatial heterogeneity. The new J{sup *}/{phi}{sup *} expression, while more expensive to obtain, generates biasing parameters that vary smoothly across the spatial domain. The result is an improvement in simulation efficiency. A representative test problem has been developed and analyzed to demonstrate the advantage of the updated biasing parameter expression with regards to solution figure of merit (FOM). For reference, the two variants of the LIFT method are compared to a similar variance reduction method developed by Depinay [4, 5], as well as MC with deterministic adjoint weight windows (WW). (authors)

97 MATHEMATICS AND COMPUTING↗

MOCVD Surface Preparation of V-Groove Si for III-V Growth

V-groove nanopatterning of Si substrates has recently demonstrated promise for achieving high-quality III-V-on-Si epitaxy while providing a lower-cost processing route than chemo-mechanical polishing to produce epi-ready planar wafers. A key factor in determining the crystalline quality of III-V buffer layers is the Si surface structure and its chemical composition. Unlike planar Si surfaces, the surfaces of V-grooves prior to growth have not been studied in detail. Here, we study the surface of V-groove Si prepared for GaP nucleation via X-ray photoelectron spectroscopy and low-energy electron diffraction. We identify several pretreatments, using both 830 and 1000 annealing under an As background pressure, as being suitable for deoxidizing and cleaning the V-groove Si surface. The V-groove Si was found to behave similarly to reference Si(0 0 1) and Si(1 1 1) planar samples, demonstrating that in situ techniques such as reflection anisotropy spectroscopy can be used on reference samples to infer the state of the V-groove surface, and indicating that the extensive research on planar Si surfaces can be directly applied to V-grooves.

III-V epitaxy↗

Enhanced photo(geno)toxicity of demethylated chlorpromazine metabolites

Chlorpromazine (CPZ) is an anti-psychotic drug widely used to treat disorders such as schizophrenia or manic-depression. Unfortunately, CPZ exhibits undesirable side effects such as phototoxic and photoallergic reactions in humans. In general, the influence of drug metabolism on this type of reactions has not been previously considered in photosafety testing. Thus, the present work aims to investigate the possible photo(geno)toxic potential of drug metabolites, using CPZ as an established reference compound. In this case, the metabolites selected for the study are demethylchlorpromazine (DMCPZ), didemethylchlorpromazine (DDMCPZ) and chlorpromazine sulfoxide (CPZSO). The demethylated CPZ metabolites DMCPZ and DDMCPZ maintain identical chromophore to the parent drug. In this work, it has been found that the nature of the aminoalkyl side chain modulates the hydrophobicity and the photochemical properties (for instance, the excited state lifetimes), but it does not change the photoreactivity pattern, which is characterized by reductive photodehalogenation, triggered by homolytic carbon-chlorine bond cleavage with formation of highly reactive aryl radical intermediates. Accordingly, these metabolites are phototoxic to cells, as revealed by the 3T3 NRU assay; their photo-irritation factors are even higher than that of CPZ. The same trend is observed in photogenotoxicity studies, both with isolated and with cellular DNA, where DMCPZ and DDMCPZ are more active than CPZ itself. In summary, side-chain demethylation of CPZ, as a consequence of Phase I biotransformation, does not result a photodetoxification. Instead, it leads to metabolites that exhibit in an even enhanced photo(geno)toxicity. - Highlights: • Demethylated CPZ metabolites are phototoxic to cells, as revealed by the NRU assay. • Single cell electrophoresis (Comet Assay) confirms the photodamage to cellular DNA. • DNA single strand breaks formation is observed on agarose gel electrophoresis. • Photochemical and EPR studies support generation of aryl radicals by C-Cl cleavage. • The aminoalkyl side chain of metabolites modulates the photo(geno)toxic potential.

60 APPLIED LIFE SCIENCES↗

Dielectric constant engineering of nonfullerene acceptors enables a record fill factor of 83.58% and a high efficiency of 20.80% in organic solar cells

Organic solar cells (OSCs) have achieved power conversion efficiencies (PCEs) surpassing 20%, but their development remains hindered by the inherently low dielectric constant (εr) of organic semiconductors, which limits charge transport and contributes to serious recombination losses. Herein, we present a comprehensive strategy to overcome the challenge by engineering the dielectric properties of nonfullerene acceptors (NFAs). Two Y-series NFAs of BTP-N3F and BTP-C3F have been synthesized featuring trifluoromethyl (CF 3 ) end-capped alkyl side chains. This molecular design significantly enhances the dipole moment and ε r (up to ∼5.9) when compared to the reference acceptor Y6 (∼3), reducing the exciton binding energy (E b ) and improving charge transport. Furthermore, the incorporation of a high-εr polymer additive, poly(pentafluorostyrene) (PPFS), synergistically improves the active layer morphology and dielectric properties, enabling efficient charge extraction and reduced recombination losses. Devices based on the optimized D18-Cl/BTP-C3F system have achieved a record-high fill factor (FF) of 83.58% and an impressive PCE of 20.80%, setting a new benchmark for OSCs. Finally, our results underscore the pivotal role of ε r in enhancing device performance and establish a versatile pathway for advancing OSC efficiency and stability through molecular and morphological optimization.

36 MATERIALS SCIENCE↗

Methodologies to determine forces on bones and muscles of body segments during exercise, employing compact sensors suitable for use in crowded space vehicles

A complete description of an instrumented ergometer system, including the sensors, the data acquisition system, and the methodologies to calculate the kinematic parameters were initially developed at Tulane University. This work was continued by the PI at NASA Johnson Space Center, where a flight ergometer was instrumented and tested during a KC-135 Zero-Gravity flight. The sensors that form part of the system include EMG probes and accelerometers mounted on the subject using the ergometer, load cells to measure pedal forces, and encoders to measure position and orientation of the pedal (foot). Currently, data from the flight test is being analyzed and processed to calculate the kinematic parameters of the individual. The formulation developed during the initial months of the grant will be used for this purpose. The system's components are compact (all sensors are very small). A salient feature of the system and associated methodology to determine the kinematics is that although it uses accelerometers, position is not determined by integration. Position is determined by determining the angle of two frames of reference for which acceleration at one point is known in coordinates of both frames.

Figueroa, Fernando↗

Microbatteries for Combinatorial Studies of Conventional Lithium-Ion Batteries

Integrated arrays of microscopic solid-state batteries have been demonstrated in a continuing effort to develop microscopic sources of power and of voltage reference circuits to be incorporated into low-power integrated circuits. Perhaps even more importantly, arrays of microscopic batteries can be fabricated and tested in combinatorial experiments directed toward optimization and discovery of battery materials. The value of the combinatorial approach to optimization and discovery has been proven in the optoelectronic, pharmaceutical, and bioengineering industries. Depending on the specific application, the combinatorial approach can involve the investigation of hundreds or even thousands of different combinations; hence, it is time-consuming and expensive to attempt to implement the combinatorial approach by building and testing full-size, discrete cells and batteries. The conception of microbattery arrays makes it practical to bring the advantages of the combinatorial approach to the development of batteries.

West, William↗

Atomic Oxygen Fluence Monitor

This innovation enables a means for actively measuring atomic oxygen fluence (accumulated atoms of atomic oxygen per area) that has impinged upon spacecraft surfaces. Telemetered data from the device provides spacecraft designers, researchers, and mission managers with real-time measurement of atomic oxygen fluence, which is useful for prediction of the durability of spacecraft materials and components. The innovation is a compact fluence measuring device that allows in-space measurement and transmittance of measured atomic oxygen fluence as a function of time based on atomic oxygen erosion yields (the erosion yield of a material is the volume of material that is oxidized per incident oxygen atom) of materials that have been measured in low Earth orbit. It has a linear electrical response to atomic oxygen fluence, and is capable of measuring high atomic oxygen fluences (up to >10(exp 22) atoms/sq cm), which are representative of multi-year low-Earth orbital missions (such as the International Space Station). The durability or remaining structural lifetime of solar arrays that consist of polymer blankets on which the solar cells are attached can be predicted if one knows the atomic oxygen fluence that the solar array blanket has been exposed to. In addition, numerous organizations that launch space experiments into low-Earth orbit want to know the accumulated atomic oxygen fluence that their materials or components have been exposed to. The device is based on the erosion yield of pyrolytic graphite. It uses two 12deg inclined wedges of graphite that are over a grit-blasted fused silica window covering a photodiode. As the wedges erode, a greater area of solar illumination reaches the photodiode. A reference photodiode is also used that receives unobstructed solar illumination and is oriented in the same direction as the pyrolytic graphite covered photodiode. The short-circuit current from the photodiodes is measured and either sent to an onboard data logger, or transmitted to a receiving station on Earth. By comparison of the short-circuit currents from the fluence-measuring photodiode and the reference photodiode, one can compute the accumulated atomic oxygen fluence arriving in the direction that the fluence monitor is pointing. The device produces a signal that is linear with atomic oxygen fluence using a material whose atomic oxygen erosion yield has been measured over a period of several years in low-Earth orbit.

Banks, Bruce A.↗

Radiation Leakage and the Precision of Characterizing Nuclear Material Using Calorimetric Assay - 19233

For measuring a waste drum containing multi-nuclide radioactive material calorimetric assay is often combined with gamma ray and neutron measurements. To reduce the methodological uncertainties of the inventory determination in a multi-nuclide matrix, the escaping radiation must be quantized as much as the encapsulated gamma-rays and α-, β-, n- particles depositing radiological heat inside the drum. To differentiate the possible variety of heat sources in a radioactive waste drum, Monte Carlo simulations are utilized resembling the waste drum and the calorimeter in both, their geometries as well as the material compositions. MCNP6-based numerical imaging of the Large Volume Calorimeter (LVC) designed by KEP Nuclear(France) allows simulating various scenarios for different particles types, energies and source locations to accompany and support the interpretation of calorimetric KEP-LVC measurements anticipated within the CHANCE project. For the analyses, the particle flux and energy deposition in each layer of the calorimeter are displayed. The results yield that a significant part of the emitted radiation leaves the system and does not contribute to the heat deposited inside the drum. As an example, the particle flux study of a 200 L mock-up drum placed inside the KEP-LVC calorimeter is discussed. A tally 4 with mesh option for both gamma and neutrons up to 5 MeV simulates the mean flux in each cell and for various source location and source distribution patterns. The expected energy deposition is cumulated for each layer, and over the whole energy range it reveals that actually a small but well known fraction of particles escapes the LVC calorimeter. This makes it a very suitable apparatus for the anticipated experiments on large and heterogeneous waste drums. The results suggest that the most interesting cases would be polyethylene, bitumen and concrete matrices [3, 5]. However, it must be kept in mind that the high-energy part of the gamma and neutron radiation flux can reach the reference chamber of the calorimeter and deposit some energy there, which may compromise the calibration and cause double-bias. The simulations showed that, depending on source location and power, neutron and high-energy gamma radiation leakage can influence the heat measurements differently. In general, part of the simulation results suggest that for waste drums with a high emission rate the accuracy of calorimetric assay can be decreased due to radiation escape. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Method to Correct the Electrochemical Concentration Cell (ECC) Ozonesonde Time Response and its Implications for "Background Current" and Pump Efficiency

The electrochemical concentration cell (ECC) ozonesonde has been the main instrument for in situ profiling of ozone worldwide; yet, some details of its operation, which contribute to the ozone uncertainty budget, are not well understood. Here, we investigate the time response of the chemical reactions inside the ECC and how corrections can be used to remove some systematic biases. The analysis is based on the understanding that two reaction pathways involving ozone occur inside the ECC that generate electrical currents on two very different timescales. The main fast-reaction pathway with a time constant of about 20 s is due the conversion of iodide to molecular iodine and the generation of two free electrons per ozone molecule. A secondary slow-reaction pathway involving the buffer generates an excess current of about 2 %–10 % with a time constant of about 25 min. This excess current can be interpreted as what has conventionally been considered the “background current”. This contribution can be calculated and removed from the measured current instead of the background current. Here we provide an algorithm to calculate and remove the contribution of the slow-reaction pathway and to correct for the time lag of the fast-reaction pathway. This processing algorithm has been applied to ozonesonde profiles at Costa Rica and during the Central Equatorial Pacific Experiment (CEPEX) as well as to laboratory experiments evaluating the performance of ECC ozonesondes. At Costa Rica, where a 1 % KI, 1/10th buffer solution is used, there is no change in the derived total ozone column; however, in the upper troposphere and lower stratosphere, average reported ozone concentrations increase by up to 7 % and above 30 km decrease by up to 7 %. During CEPEX, where a 1 % KI, full-buffer solution was used, ozone concentrations are increased mostly in the upper troposphere, with no change near the top of the profile. In the laboratory measurements, the processing algorithms have been applied to measurements using the majority of current sensing solutions and using only the stronger pump efficiency correction reported by Johnson et al. (2002). This improves the accuracy of the ECC sonde ozone profiles, especially for low ozone concentrations or large ozone gradients and removes systematic biases relative to the reference instruments. In the surface layer, operational procedures prior to launch, in particular the use of filters, influence how typical gradients above the surface are detected. The correction algorithm may report gradients that are steeper than originally reported, but their uncertainty is strongly influenced by the prelaunch procedures.

electrochemical concentration cell (ECC) ozonesond↗