Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Computer-aided diagnosis for classifying benign versus malignant thyroid nodules based on ultrasound images: A comparison with radiologist-based assessments

Purpose: To develop a semiautomated computer-aided diagnosis (CAD) system for thyroid cancer using two-dimensional ultrasound images that can be used to yield a second opinion in the clinic to differentiate malignant and benign lesions. Methods: A total of 118 ultrasound images that included axial and longitudinal images from patients with biopsy-confirmed malignant (n = 30) and benign (n = 29) nodules were collected. Thyroid CAD software was developed to extract quantitative features from these images based on thyroid nodule segmentation in which adaptive diffusion flow for active contours was used. Various features, including histogram, intensity differences, elliptical fit, gray-level co-occurrence matrixes, and gray-level run-length matrixes, were evaluated for each region imaged. Based on these imaging features, a support vector machine (SVM) classifier was used to differentiate benign and malignant nodules. Leave-one-out cross-validation with sequential forward feature selection was performed to evaluate the overall accuracy of this method. Additionally, analyses with contingency tables and receiver operating characteristic (ROC) curves were performed to compare the performance of CAD with visual inspection by expert radiologists based on established gold standards. Results: Most univariate features for this proposed CAD system attained accuracies that ranged from 78.0% to 83.1%. When optimal SVM parameters that were established using a grid search method with features that radiologists use for visual inspection were employed, the authors could attain rates of accuracy that ranged from 72.9% to 84.7%. Using leave-one-out cross-validation results in a multivariate analysis of various features, the highest accuracy achieved using the proposed CAD system was 98.3%, whereas visual inspection by radiologists reached 94.9% accuracy. To obtain the highest accuracies, “axial ratio” and “max probability” in axial images were most frequently included in the optimal feature sets for the authors’ proposed CAD system, while “shape” and “calcification” in longitudinal images were most frequently included in the optimal feature sets for visual inspection by radiologists. The computed areas under curves in the ROC analysis were 0.986 and 0.979 for the proposed CAD system and visual inspection by radiologists, respectively; no significant difference was detected between these groups. Conclusions: The use of thyroid CAD to differentiate malignant from benign lesions shows accuracy similar to that obtained via visual inspection by radiologists. Thyroid CAD might be considered a viable way to generate a second opinion for radiologists in clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We have validated the dosimetric accuracy of a commercial MRgIMRT system using high-resolution 3D techniques. We have demonstrated for the first time that hybrid 3D remote dosimetry is a comprehensive and feasible approach to commissioning MRgIMRT. This may provide better sensitivity in error detection compared with standard 2-dimensional measurements and could be used when implementing complex new magnetic resonance guided radiation therapy technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Integrated Design Approach for Infill Patterning of Fused Deposition Modeling and its Application to an Airfoil

We present a new approach to incorporate an internal stress distribution into the design of infill via fused deposition modeling of additive manufacturing (AM). This design approach differs from topology optimization, since the topology optimization of AM focuses on changing the overall shape of the product, whereas the approach we propose in this research focuses on the porous infill and remains the overall shape of the product intact. The approach presented here is effective if the overall shape is an important functioning aspect of a product and the stress is applied to the entire body, not to given localized points. As an application, we demonstrate an airfoil with its infill densities optimized based on the pressure applied during operation. Specifically, the stress of an airfoil is analyzed with operational loading conditions. The local density of the infill pattern is determined based on the computational stress analysis. The infill geometry is mathematically generated using a circle packing algorithm. Test results show that the airfoil with the optimized infill outperforms the same shape with the traditional uniform infill pattern of an airfoil having the same weight.

Kim, Pum↗

Global analysis of general SU(2)xSU(2)xU(1) models with precision data

We present the results of a global analysis of a class of models with an extended electroweak gauge group of the form SU(2)xSU(2)xU(1), often denoted as G(221) models, which include as examples the left-right, the leptophobic, the hadrophobic, the fermiophobic, the un-unified, and the nonuniversal models. Using an effective Lagrangian approach, we compute the shifts to the coefficients in the electroweak Lagrangian due to the new heavy gauge bosons, and obtain the lower bounds on the masses of the Z{sup '} and W{sup '} bosons. The analysis of the electroweak parameter bounds reveals a consistent pattern of several key observables that are especially sensitive to the effects of new physics and thus dominate the overall shape of the respective parameter contours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrating GLL-Weibull Distribution Within a Bayesian Framework for Life Prediction of Shape Memory Alloy Spring Undergoing Thermo-mechanical Fatigue

The present paper tackles an important but unmapped problem of the reliability estimations of smart materials. First, an experimental setup is developed for accelerated life testing of the shape memory alloy (SMA) springs. Generalized log-linear Weibull (GLL-Weibull) distribution-based novel approach is then developed for SMA spring life estimation. Applied stimulus (voltage), elongation and cycles of operation are used as inputs for the life prediction model. The values of the parameter coefficients of the model provide better interpretability compared to artificial intelligence based life prediction approaches. In addition, the model also considers the effect of operating conditions, making it generic for a range of the operating conditions. Moreover, a Bayesian framework is used to continuously update the prediction with the actual degradation value of the springs, thereby reducing the uncertainty in the data and improving the prediction accuracy. In addition, the deterioration of material with number of cycles is also investigated using thermogravimetric analysis and scanning electron microscopy.

36 MATERIALS SCIENCE↗

First observation of the Λ ( 1405 ) line shape in electroproduction

We report the first observation of the line shape of the Λ ( 1405 ) from electroproduction, and show that it is not a simple Breit-Wigner resonance. Electroproduction of K + Λ ( 1405 ) off the proton was studied by using data from CLAS at Jefferson Lab in the range 1.0 < Q 2 < 3.0 (GeV/ c ) 2 . The analysis utilized the decay channels Σ + π - of the Λ ( 1405 ) and p π 0 of the Σ + . Neither the standard Particle Data Group resonance parameters, nor free parameters fitting to a single Breit-Wigner resonance represent the line shape. In our fits, the line shape corresponds approximately to predictions of a two-pole meson-baryon picture of the Λ ( 1405 ) , with a lower mass pole near 1368 MeV/ c 2 and a higher mass pole near 1423 MeV/ c 2 . Furthermore, with increasing photon virtuality the mass distribution shifts toward the higher mass pole.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Science-based HRA: experimental comparison of operator performance to IDAC (Information-Decision-Action Crew) simulations

Information-Decision-Action Crew (IDAC) operator model simulations of a Steam Generator Tube Rupture are compared to student operator performance in studies conducted in the Ohio State University’s Nuclear Power Plant Simulator Facility. This study is presented as a prototype for conducting simulator studies to validate key aspects of Human Reliability Analysis (HRA) methods. Seven student operator crews are compared to simulation results for crews designed to demonstrate three different decision-making strategies. The IDAC model used in the simulations is modified slightly to capture novice behavior rather that expert operators. Operator actions and scenario pacing are compared. A preliminary review of available performance shaping factors (PSFs) is presented. After the scenario in the NPP Simulator Facility, student operators review a video of the scenario and evaluate six PSFs at pre-determined points in the scenario. This provides a dynamic record of the PSFs experienced by the OSU student operators. In this preliminary analysis, Time Constraint Load (TCL) calculated in the IDAC simulations is compared to TCL reported by student operators. We identify potential modifications to the IDAC model to develop an “IDAC Student Operator Model.” This analysis provides insights into how similar experiments could be conducted using expert operators to improve the fidelity of IDAC simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Toward the Neutrino Discovery Platform: An Auditable, Uncertainty-Bearing Toolchain for MINERvA Open-Data Cross-Section Analysis

The Neutrino Discovery Platform (NDP) aims to accelerate DUNE-era science by making the neutrino program's existing datasets analyzable through fast, reproducible, and auditable workflows. We report a working version of two of its layers, data curation and agentic orchestration, built and tested end to end on MINERvA open data. The guiding lesson throughout is that a cross section is a measurement, and not just a plotted shape, only if it carries a defensible systematic-uncertainty budget, a trustworthy unfolding, and a reproducible record. Using a single medium-energy playlist pair from the MINERvA open-data release (about $2.05\times10^{17}$ protons on target of data), we first reproduced the shapes of two published charged-current inclusive $\nu_\mu$ measurements through a complete extraction ladder: selection, background subtraction, D'Agostini unfolding, efficiency correction, and flux normalization. These shape-level reproductions ran and tracked the published results, but they lacked the systematic-uncertainty machinery that defines a MINERvA cross section. To supply it, we vendored and built the MINERvA Analysis Toolkit and developed a many-universe systematic-uncertainty tool that produces a portable covariance artifact, a parallel event-loop runner, and a per-run auditability harness. Validated against a published covariance release, the toolchain reproduces the released statistical, flux, and muon-energy-scale terms and shows that they account for roughly 63\% of the total variance, with the remainder unreleased. Using this same infrastructure, we then performed a measurement of our own design, the hadronic recoil-energy distribution of low-energy ($E_\nu<2.5$~GeV) charged-current inclusive events, and found data/simulation shape agreement of $\chi^2/\mathrm{ndf}=1.26$. Together these results show that the platform supports original physics and not only reproductions.

Breaux, Auto [Tulane U. (main)]↗

Coherent X-ray diffractive imaging of protein crystals

The technique of coherent X-ray diffraction imaging (CXDI) has recently shown great promise for the study of inorganic nanocrystals. In this work the CXDI method has been applied to the study of micrometer-size protein crystals. Finely sampled diffraction patterns of single crystals were measured and iterative phase-retrieval algorithms were used to reconstruct the two-dimensional shape of the crystal. The density maps have limited reproducibility because of radiation damage, but show clear evidence for crystal facets. Qualitative analysis of a number of single-crystal diffraction peaks indicates the presence of inward surface contraction on 2 {micro}m size crystals. A survey of several hundred diffraction patterns yielded a number of examples with dramatic single-sided streaks, for which a plausible model is constructed.

59 BASIC BIOLOGICAL SCIENCES↗

A hybrid method for quasi-three-dimensional slope stability analysis in a municipal solid waste landfill

Highlights: > A quasi-three-dimensional slope stability analysis method was proposed. > The proposed method is a good engineering tool for 3D slope stability analysis. > Factor of safety from 3D analysis is higher than from 2D analysis. > 3D analysis results are more sensitive to cohesion than 2D analysis. - Abstract: Limited space for accommodating the ever increasing mounds of municipal solid waste (MSW) demands the capacity of MSW landfill be maximized by building landfills to greater heights with steeper slopes. This situation has raised concerns regarding the stability of high MSW landfills. A hybrid method for quasi-three-dimensional slope stability analysis based on the finite element stress analysis was applied in a case study at a MSW landfill in north-east Spain. Potential slides can be assumed to be located within the waste mass due to the lack of weak foundation soils and geosynthetic membranes at the landfill base. The only triggering factor of deep-seated slope failure is the higher leachate level and the relatively high and steep slope in the front. The valley-shaped geometry and layered construction procedure at the site make three-dimensional slope stability analyses necessary for this landfill. In the finite element stress analysis, variations of leachate level during construction and continuous settlement of the landfill were taken into account. The 'equivalent' three-dimensional factor of safety (FoS) was computed from the individual result of the two-dimensional analysis for a series of evenly spaced cross sections within the potential sliding body. Results indicate that the hybrid method for quasi-three-dimensional slope stability analysis adopted in this paper is capable of locating roughly the spatial position of the potential sliding mass. This easy to manipulate method can serve as an engineering tool in the preliminary estimate of the FoS as well as the approximate position and extent of the potential sliding mass. The result that FoS obtained from three-dimensional analysis increases as much as 50% compared to that from two-dimensional analysis implies the significance of the three-dimensional effect for this study-case. Influences of shear parameters, time elapse after landfill closure, leachate level as well as unit weight of waste on FoS were also investigated in this paper. These sensitivity analyses serve as the guidelines of construction practices and operating procedures for the MSW landfill under study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-32: A Feasibility Study of Independent Dose Verification for IMAT

Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose calculation software program (Simple MU Analysis, Triangle Products, JP) was used in this study, which can compute the radiological path length from the surface to the reference point for each control point using patient’s CT image dataset and the MLC aperture shape was simultaneously modeled in reference to the information of MLC from DICOM-RT plan. Dose calculation was performed using a modified Clarkson method considering MLC transmission and dosimetric leaf gap. In this study, a retrospective analysis was conducted in which IMAT plans from 120 patients of the two sites (prostate / head and neck) from four institutes were retrospectively analyzed to compare the Indp to the TPS using patient CT images. In addition, an ion-chamber measurement was performed to verify the accuracy of the TPS and the Indp in water-equivalent phantom. Results: The agreements between the Indp and the TPS (mean±1SD) were −0.8±2.4% and −1.3±3.8% for the regions of prostate and head and neck, respectively. The measurement comparison showed similar results (−0.8±1.6% and 0.1±4.6% for prostate and head and neck). The variation was larger in the head and neck because the number of the segments was increased that the reference point was under the MLC and the modified Clarkson method cannot consider the smooth falloff of the leaf penumbra. Conclusion: The independent verification program would be practical and effective for secondary check for IMAT with the sufficient accuracy in the measurement and CT-based calculation. The accuracy would be improved if considering the falloff of the leaf penumbra.

60 APPLIED LIFE SCIENCES↗

Spectral diagnostics based on Doppler-broadened H{sub α} line shape in a single element of a matrix source

The study is on optical emission spectroscopy diagnostics of a single element of a matrix source of negative hydrogen ions. The method developed for description of the hydrogen atoms behaviour is based on analysis of the Balmer H{sub α} line profile, and it can be readily applied to various low pressure hydrogen discharges. The present observations reveal the existence of thermal as well as of non-thermal fast hydrogen atoms in the discharge. For processing of the experimental data a line shape model, which accounts for details of the plasma kinetics and the fine structure of the Balmer lines is developed. The fit of this model to the recorded at different experimental conditions line shapes results in the temperature of the thermal atoms, the mean energy of the fast atoms, the ratio between the densities of these two group of atoms and the relative populations of the fine structure components of the n = 3 hydrogen state. The present study indicates that the reactions leading to production of fast atoms and the process of energy exchange between thermal and fast atoms may be important for the correct modeling of the plasma kinetics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MeV-ion beam analysis of the interface between filtered cathodic arc-deposited a-carbon and single crystalline silicon

Amorphous carbon (a-C) films were deposited on Si(100) wafers by a filtered cathodicvacuum arc (FCVA) plasma source. A negative electrical bias was applied tothe silicon substrate in order to control the incident energy of carbon ions. Effects ofthe electrical bias on the a-C/Si interface characteristics were investigated by usingstandard Rutherford backscattering spectrometry (RBS) in the channeling modewith 2.1-MeV He2+ ions. The shape of the Si surface peaks of the RBS/channelingspectra reflects the degree of interface disorder due to atomic displacement fromthe bulk position of the Si crystal. Details of the analysis method developed aredescribed. It was found that the width of the a-C/Si interface increases linearlywith the substrate bias voltage but not the thickness of the a-C film.

36 MATERIALS SCIENCE↗

Three-dimensional evaluation of the compression and recovery behavior in a flexible graphite sheet by synchrotron radiation microtomography

The compression and unloading behavior of flexible graphite sheets was investigated using synchrotron radiation microtomography with 1 {mu}m voxel size. The recovery ratio of the flexible graphite sheet was measured accurately by in-situ observation. The three-dimensional strain distribution in the interior of the specimen was obtained using the microstructural tracking method. The inner strain distribution with micrometer scale indicated inhomogeneous deformation. The microstructural tracking analysis revealed that deformation units exist in the flexible graphite sheet. The units seem to deform, affecting the neighboring units with each other. The units had a similar size and shape with compacted exfoliated graphite worms that constitute the flexible graphite sheet. Microscopic deformations during compression and unloading are surely affected by the microstructure of the sheet. Highlights: Black-Right-Pointing-Pointer The compression and recovery behavior was investigated using microtomography. Black-Right-Pointing-Pointer The tracking analysis revealed that deformation units exist in the specimen. Black-Right-Pointing-Pointer Each unit deforms in relation to the neighboring unit.

36 MATERIALS SCIENCE↗

Destabilization of the PCNA trimer mediated by its interaction with the NEIL1 DNA glycosylase

The base excision repair (BER) pathway repairs oxidized lesions in the DNA that result from reactive oxygen species generated in cells. If left unrepaired, these damaged DNA bases can disrupt cellular processes such as replication. NEIL1 is one of the 11 human DNA glycosylases that catalyze the first step of the BER pathway, i.e. recognition and excision of DNA lesions. NEIL1 interacts with essential replication proteins such as the ring-shaped homotrimeric proliferating cellular nuclear antigen (PCNA). We isolated a complex formed between NEIL1 and PCNA (±DNA) using size exclusion chromatography (SEC). This interaction was confirmed using native gel electrophoresis and mass spectrometry. Stokes radii measured by SEC hinted that PCNA in complex with NEIL1 (±DNA) was no longer a trimer. Height measurements and images obtained by atomic force microscopy also demonstrated the dissociation of the PCNA homotrimer in the presence of NEIL1 and DNA, while small-angle X-ray scattering analysis confirmed the NEIL1 mediated PCNA trimer dissociation and formation of a 1:1:1 NEIL1-DNA-PCNA(monomer) complex. Furthermore, ab initio shape reconstruction provides insights into the solution structure of this previously unreported complex. Together, these data point to a potential mechanistic switch between replication and BER.

59 BASIC BIOLOGICAL SCIENCES↗

Squeezed Nanocrystals: Equilibrium Configuration of Metal Clusters Embedded Beneath the Surface of a Layered Material

Shapes of functional metallic nanocrystals, typically synthesized either free in solution or supported on surfaces, are key for controlling properties. Here, we consider a novel new class of metallic nanocrystals, copper clusters embedded near the surface of graphite, which can be considered a model system for metals embedded beneath surfaces of layered materials, or beneath supported membranes. We develop a continuum elasticity (CE) model for the equilibrium shape of these islands, and compare its predictions with experimental data. The CE model incorporates appropriate surface energy, adhesion energies, and strain energy. The agreement between the CE model and the data is—with one exception—excellent, both qualitatively and quantitatively, and is achieved with a single adjustable parameter. The model predicts that the embedded island shape is invariant with size, manifest both by constant side slope and by constant aspect ratio. This prediction is rationalized by dimensional analysis of the relevant energetic contributions. The aspect ratio of an embedded Cu cluster is much larger than that of a supported but non-embedded Cu cluster, due to resistance of the graphene membrane to deformation. Experimental data diverge from the model predictions only in the case of the aspect ratio of small islands, below a critical height of ~10 nm. The divergence may be due to bending strain, which is treated only approximately in the model. Strong support for the CE model and its interpretation is provided by additional data for embedded Fe clusters. Most of these observations and insights should be generally applicable to systems where a metal cluster is embedded beneath a layered material or supported membrane, provided that shape equilibration is possible.

Julien, Scott↗

A posteriori error analysis for a cut cell finite volume method

We study the solution of a diffusive process in a domain where the diffusion coefficient changes discontinuously across a curved interface. We consider discretizations that use regularly-shaped meshes, so that the interface “cuts” through the cells (elements or volumes) without respecting the regular geometry of the mesh. Consequently, the discontinuity in the diffusion coefficients has a strong impact on the accuracy and convergence of the numerical method. This motivates the derivation of computational error estimates that yield accurate estimates for specified quantities of interest. For this purpose, we adapt the well-known adjoint based a posteriori error analysis technique used for finite element methods. In order to employ this method, we describe a systematic approach to discretizing a cut-cell problem that handles complex geometry in the interface in a natural fashion yet reduces to the well-known Ghost Fluid Method in simple cases. We test the accuracy of the estimates in a series of examples.

97 MATHEMATICS AND COMPUTING↗

Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate [Comparison of implosion core shape observations, 10 ps dilation X-ray imager vs 100 ps gated microchannel plate]

The dilation x-ray imager (DIXI) is a high-speed x-ray framing camera that uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps. This is a 10× improvement over conventional framing cameras currently employed on the National Ignition Facility (NIF) (100 ps resolution), and otherwise only achievable with 1D streaked imaging. A side effect of the dramatically reduced gate width is the comparatively lower detected signal level. Therefore we implement a Poisson noise reduction with non-local principal component analysis method to improve the robustness of the DIXI data analysis. Furthermore, we present results on ignition-relevant experiments at the NIF using DIXI. In particular we focus on establishing that/when DIXI gives reliable shape metrics (P 0 , P 2 and P 4 Legendre modes, and their temporal evolution/swings).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗