Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Concerted Bimetallic Nanocluster Synthesis and Encapsulation via Induced Zeolite Framework Demetallation for Shape and Substrate Selective Heterogeneous Catalysis

Abstract Bimetallic nanoparticle encapsulation in microporous zeolite crystals is a promising route for producing catalysts with unprecedented reaction selectivities. Herein, a novel synthetic approach was developed to produce PtZn x nanoclusters encapsulated inside zeolite micropores by introducing Pt 2+ cations into a zincosilicate framework via ion exchange, and subsequent controlled demetallation and alloying with framework Zn. The resulting zeolites featured nanoclusters with sizes of approximately 1 nm, having an interatomic structure corresponding to a PtZn x alloy as confirmed by pair distribution function (PDF) analysis. These materials featured simultaneous shape and substrate specificity demonstrated by the selective production of p ‐chloroaniline from the competitive hydrogenation of p ‐chloronitrobenzene and 1,3‐dimethyl‐5‐nitrobenzene.

Iida, Takayuki↗

In-Flight Measurements of Capsule Adiabats in Laser Driven Spherical Implosions

We present the first x-ray Thomson scattering measurements of temperature and density from spherically imploding matter. The shape of the Compton downscattered spectrum provides a first-principles measurement of the electron velocity distribution function, dependent on T{sub e} and the Fermi temperature T{sub F} {approx} n{sub e}{sup 2/3}. In flight compressions of Be and CH targets reach 6-13 times solid density, with T{sub e}/T{sub F} {approx} 0.4-0.7, resulting in minimum adiabats of {approx}1.6-2. These measurements are consistent with low-entropy implosions and predictions by simulations using radiation-hydrodynamic modeling.

42 ENGINEERING↗

Differentiating Structural Changes of Glycoproteins in Solution using Small Angle Scattering Analysis

Alpha 1-Antitrypsin (A1AT) and Fibrinogen are plasma glycoproteins with different, but specific biological functions. A1AT (which forms part of the serpin family) has been shown to have protective roles of lung cells against emphysema, a disease characterized by lung tissue destruction, while fibrinogen is a major factor in the blood clotting process. While biologically distinct, the two proteins present similarities in biophysical studies due to their size and polymerization tendency. Previous approximations, using radius of gyration analysis (shape independent), have shown that there is a phase transition for A1AT under osmotic stress. The goals of this study are to better understand: the stability of A1AT's native conformation when its environment deviates from physiological conditions; and the effects on fibrin's final structure as fibrinogen undergoes polymerization under different conditions. Environmental variables include osmotic stress, crowding, and presence of other molecules (e.g. lipids, catalytic enzyme thrombin, or cholesterol) found in plasma. The method used to assess the stability of the native conformation was to observe changes in the structural envelope of the protein. Static and dynamic small angle x-ray scattering (SAXS) and small angle neutron scattering (SANS) experiments of the proteins in solution were conducted for this purpose. Scattering data was fitted using various shape dependent models in SASView. Pair distance functions (PDF) were used to validate any changes identified by the model fits. Multi-variable phase diagrams were constructed from the fitting results in order to quantify structural and conformational changes of the proteins.

Segally, Taylor N.↗

Fitting theoretical photometric functions to asteroid phase curves

The ways in which variations in the parameters of Hapke's (1981, 1984, 1986) theoretical photometric function for fitting photometric phase data of asteroids can affect the shape of the theoretical curve are considered. It is noted that, between phase angles of 2 and 25 deg, the opposition effect parameters, the roughness parameter, and the single-particle phase function parameter have similar effects on the shape and the photometric curve and are difficult to separate on the basis of disk-integrated data alone. The uniqueness of asteroid surface properties deduced from phase curve observations over a limited phase-angle range is judged to remain questionable.

Domingue, Deborah↗

Low energy electron microscopy and Auger electron spectroscopy studies of Cs-O activation layer on p-type GaAs photocathode

Work function, photoemission yield, and Auger electron spectra were measured on (001) p-type GaAs during negative electron affinity (NEA) surface preparation, surface degradation, and heating processes. The emission current sensitively depends on work function change and its dependence allows us to determine that the shape of the vacuum barrier was close to double triangular. Regarding the NEA surface degradation during photoemission, we discuss the importance of residual gas components the oxygen and hydrogen. We also found that gentle annealing (≤100 °C) of aged photocathodes results in a lower work function and may offer a patch to reverse the performance degradation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Power spectrum of small-scale density irregularities in the interstellar medium

Observations of the interstellar scintillation of radiation from 17 pulsars are reported which are used to place limits on the power spectrum of small-scale electron density irregularities in the interstellar medium. Measurements made at 340, 408, and 450 MHz in the dispersion measure range 3-57/cu cm pc of the time-dependent radio frequency spectrum of interstellar scintillations were analyzed to determine the scintillation index and a scintillation frequency-correlation scale based on the autocorrelation function in radio frequency of the fluctuations in scintillation. The dispersion-measure dependence of the scintillation frequency correlation scale is found to be consistent with both Gaussian model interstellar medium spectra and power-law spectra with indices between 3.0 and 4, while the radio-frequency scaling of the frequency correlation scale is consistent with power law indices between 2.8 and 3.9. However comparison of the shape of the radio-frequency autocorrelation function with model calculations indicates power law models with indices greater than 3.6 are possible. Data are also consistent with a local three-dimensional density spectrum at a wave number of 10 to the -9th/m of 3 x 10 to the 28th to 3 x 10 to the 29th/cu m.

Armstrong, J. W.↗

Changes in left ventricular function as determined by the multi-wire gamma camera at near presyncopal levels of lower body negative pressure

At presyncopal levels of lower body negative pressure (LBNP), we have frequently observed electrocardiographic responses that may be due to changes in cardiac position and/or shape, but could be indicative of altered myocardial function. To further investigate this, we evaluated cardiac function using a nuclear imaging technique in 21 healthy subjects (17 men and 4 women) after 30 minutes of supine rest and near the end of a presyncopal-limited LBNP exposure (LBNP averaged 65 plus or minus 3 mmHg at injection). Cardiac first pass images were obtained with a Multi-Wire Gamma Camera following an intravenous bolus injection of 30-50 millicurries of Tantalum-178. Manual blood pressures and electrocardiograms were obtained throughout the 3 minute graded LBNP protocol. Between rest and injection during LBNP, heart rate increased (P less than 0.01) from 67 plus or minus 3 beats per minute to 99 plus or minus beats per minute, systolic blood pressure decreased (P less than 0.01) from 110 plus or minus 3 mmHg to 107 plus or minus 3 mmHg and left ventricular ejection fraction (EF) decreased (P less than 0.01) from 0.57 plus or minus 0.02 to 0.48 plus or minus 0.02. During LBNP, ST segment depression of at least 0.5 mm occurred in 7 subjects. Subjects with ST depression had greater reductions (P = 0.05) in EF than subjects without ST depression (0.15 plus or minus 0.07 versus 0.005 plus or minus 0.03), but also tolerated greater levels (P less than 0.05) of negative pressure (88 plus or minus mmHg versus 69 plus or minus 5 mmHg). There was a significant relationship between presyncopal LBNP level and EF (R(exp 2) = 0.50, P less than 0.05). Our findings suggest there may be a decrease in systolic myocardial function at high levels of LBNP.

Pintner, R.↗

Bacterial community and arsenic functional genes diversity in arsenic contaminated soils from different geographic locations

To understand how soil microbial communities and arsenic (As) functional genes respond to soil arsenic (As) contamination, five soils contaminated with As at different levels were collected from diverse geographic locations, incubated for 54 days under flooded conditions, and examined by both MiSeq sequencing of 16S rRNA gene amplicons and functional gene microarray (GeoChip 4.0). The results showed that both bacterial community structure and As functional gene structure differed among geographical locations. The diversity of As functional genes correlated positively with the diversity of 16S rRNA genes (P< 0.05). Higher diversities of As functional genes and 16S rRNA genes were observed in the soils with higher available As. Soil pH, phosphate-extractable As, and amorphous Fe content were the most important factors in shaping the bacterial community structure and As transformation functional genes. Geographic location was also important in controlling both the bacterial community and As transformation functional potential. These findings provide insights into the variation of As transformation functional genes in soils contaminated with different levels of As at different geographic locations, and the impact of environmental As contamination on the soil bacterial community.

59 BASIC BIOLOGICAL SCIENCES↗

The correlation function for density perturbations in an expanding universe. II - Nonlinear theory

A formalism is developed to find the two-point and higher-order correlation functions for a given distribution of sizes and shapes of perturbations which are randomly placed in three-dimensional space. The perturbations are described by two parameters such as central density and size, and the two-point correlation function is explicitly related to the luminosity function of groups and clusters of galaxies

Mcclelland, J.↗

Multiscale flat norm signatures for shapes and images

In this paper we begin to explore the application of the multiscale flat norm introduced in Morgan and Vixie to shape and image analysis. In particular, we look at the use of the multiscale flat norm signature for the identification of shapes. After briefly reviewing the multiscale flat norm, the L{sup 1}TV functional and the relation between these two, we introduce multiscale signatures that naturally follow from the multiscale flat norm and its components. A numerical method based on the min-cut, max-flow graph-cut is briefly recalled. We suggest using L{sup 2} minimization, rather than the usual Crofton's formula based approximation, for choosing the required weights. The resulting weights have the dual benefits of being analytically computable and of giving more accurate approximations to the anisotropic TV energy. Finally, we demonstrate the usefulness of the signatures on simple shape classification tasks.

99 GENERAL AND MISCELLANEOUS↗

Modeling the Echelle Spectra Continuum with Alpha Shapes and Local Regression Fitting

Continuum normalization of echelle spectra is an important data analysis step that is difficult to automate. Polynomial fitting requires a reasonably high-order model to follow the steep slope of the blaze function. However, in the presence of deep spectral lines, a high-order polynomial fit can result in ripples in the normalized continuum that increase errors in spectral analysis. Here, we present two algorithms for flattening the spectrum continuum. The Alpha-shape Fitting to Spectrum algorithm is completely data driven, using an alpha shape to obtain an initial estimate of the blaze function. The Alpha-shape and Lab Source Fitting to Spectrum algorithm incorporates a continuum constraint from a laboratory source reference spectrum for the blaze function estimation. These algorithms are tested on a simulated spectrum, where we demonstrate improved normalization compared to polynomial regression for continuum fitting. We show an additional application, using the algorithms for mitigation of spatially correlated quantum efficiency variations and fringing in the charge-coupled device detector of the EXtreme PREcision Spectrometer.

79 ASTRONOMY AND ASTROPHYSICS↗

A Submillimeter Perspective on the GOODS Fields (SUPER GOODS). I. An Ultradeep SCUBA-2 Survey of the GOODS-N

In this first paper in the SUPER GOODS series on powerfully star-forming galaxies in the two GOODS fields, we present a deep SCUBA-2 survey of the GOODS-N at both 850 and 450 μm (central rms noise of 0.28 mJy and 2.6 mJy, respectively). In the central region, the 850 μm observations cover the GOODS-N to near the confusion limit of ∼1.65 mJy, while over a wider 450 arcmin{sup 2} region—well complemented by Herschel far-infrared imaging—they have a median 4σ limit of 3.5 mJy. We present ⩾4σ catalogs of 186 850 μm and 31 450 μm selected sources. We use interferometric observations from the Submillimeter Array (SMA) and the Karl G. Jansky Very Large Array (VLA) to obtain precise positions for 114 SCUBA-2 sources (28 from the SMA, all of which are also VLA sources). We present new spectroscopic redshifts and include all existing spectroscopic or photometric redshifts. We also compare redshifts estimated using the 20 cm/850 μm and the 250 cm/850 μm flux ratios. We show that the redshift distribution increases with increasing flux, and we parameterize the dependence. We compute the star formation history and the star formation rate (SFR) density distribution functions in various redshift intervals, finding that they reach a peak at z=2--3 before dropping to higher redshifts. We show that the number density per unit volume of SFR ≳500 M{sub ⊙} yr{sup −1} galaxies measured from the SCUBA-2 sample does not change much relative to that of lower SFR galaxies from UV selected samples over z=2--5, suggesting that, apart from changes in the normalization, the shape in the number density as a function of SFR is invariant over this redshift interval.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved performance of stellarator coil design optimization

Following up on earlier work which demonstrated an improved numerical stellarator coil design optimization performance by the use of stochastic optimization (Lobsien et al., Nucl. Fusion, vol. 58 (10), 2018, 106013), it is demonstrated here that significant further improvements can be made – lower field errors and improved robustness – for a Wendelstein 7-X test case. This is done by increasing the sample size and applying fully three-dimensional perturbations, but most importantly, by changing the design sequence in which the optimization targets are applied: optimization for field error is conducted first, with coil shape penalties only added to the objective function at a later step in the design process. A robust, feasible coil configuration with a local maximum field error of 3.66 % and an average field error of 0.95 % is achieved here, as compared to a maximum local field error of 6.08 % and average field error of 1.56 % found in our earlier work. These new results are compared to those found without stochastic optimization using the FOCUS and ONSET suites. The relationship between local minima in the optimization space and coil shape penalties is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Objective PDF-Shaping-Based Economic Dispatch for Power Systems with Intermittent Generation Sources via Simultaneous Mean and Variance Minimization

With the ever increased penetration of renewables in power grid, economic power dispatch faces a challenge in terms of min-imizing the generation cost which is increasingly affected by random factors and constraints subjected to random inputs. In this context, the cost functions are random for which the widely used mean value based minimization can only achieve limited profit gain. Indeed, as the probability density function (PDF) is a comprehensive measure of characteristics of any random varia-bles, the desired optimization should address the shaping of the PDF of the generation cost function rather just its mean value. Through a simple case study, this paper firstly reveals the long tail PDF shape of the cost function when the traditional mean-value based optimization is used. This is then followed by the de-velopment of a novel PDF-shaping-based method that optimizes both the mean and variance of the PDF of the cost function. It has been shown that the proposed approach can reshape the PDF of the generation cost function so as to make it as left and as narrow as possible, leading to a significant low risk for high generation cost. Simulation tests have been included to show the effectiveness of the proposed approach and encouraging results have been obtained.

intermittent generation sources, uncertainties, PD↗

Atomic structure and grain shape evolution of nanodiamond during annealing in oxidizing atmosphere from neutron diffraction and MD simulations

In this work, real space pair-distribution function (PDF) analysis in conjunction with molecular dynamics (MD) simulations was applied to characterize crystal structure, shape and surface structure of diamond nanoparticles annealed in air up to 880 °C. MD simulated models of individual nanodiamond particles of various shapes and sizes were used to calculate theoretical radial distribution functions G(r) for powders with different grain size distributions. The calculated curves, showing distinct differences for the explored parameter space, were compared to the experimental G(r) functions obtained from neutron scattering for annealed detonated nanodiamond samples in a search for a model best describing the actual powders. It was found that as-synthesized nanodiamond grains are terminated by equally abundant (100), (110) and (111) crystallographic faces and their structure does not change upon annealing in air up to 280 °C. The shape and size of grains annealed above 480 °C changes due to surface etching. The etching rate differs between crystals faces and depends on temperature, resulting in the observed differences in grain shape. Below 680 °C the share of the (110) facets gradually increases and at 680 °C the grains become rhombic dodecahedra terminated solely by (110) surfaces. Further increase of the annealing temperature promotes formation of (111) surfaces and at 880 °C the preferred grain shape becomes an octahedron terminated by a variant of (111) surfaces possessing three dangling sp3 bonds per atom. At lower temperatures all grains become smaller and the size distribution moves towards the lower values. Furthermore, as the annealing temperature increases, the smallest grains disappear entirely and the average grain size grows back.

36 MATERIALS SCIENCE↗