Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Dynamic Balancing of Isoprene Carbon Sources Reflects Photosynthetic and Photorespiratory Responses to Temperature Stress

The volatile gas isoprene is emitted in teragrams per annum quantities from the terrestrial biosphere and exerts a large effect on atmospheric chemistry. Isoprene is made primarily from recently fixed photosynthate; however, alternate carbon sources play an important role, particularly when photosynthate is limiting. We examined the relative contribution of these alternate carbon sources under changes in light and temperature, the two environmental conditions that have the strongest influence over isoprene emission. Using a novel real-time analytical approach that allowed us to examine dynamic changes in carbon sources, we observed that relative contributions do not change as a function of light intensity. We found that the classical uncoupling of isoprene emission from net photosynthesis at elevated leaf temperatures is associated with an increased contribution of alternate carbon. We also observed a rapid compensatory response where alternate carbon sources compensated for transient decreases in recently fixed carbon during thermal ramping, thereby maintaining overall increases in isoprene production rates at high temperatures. Photorespiration is known to contribute to the decline in net photosynthesis at high leaf temperatures. A reduction in the temperature at which the contribution of alternate carbon sources increased was observed under photorespiratory conditions, while photosynthetic conditions increased this temperature. Feeding [2- 13 C]glycine (a photorespiratory intermediate) stimulated emissions of [ 13 C 1–5 ]isoprene and 13 CO 2 , supporting the possibility that photorespiration can provide an alternate source of carbon for isoprene synthesis. Our observations have important implications for establishing improved mechanistic predictions of isoprene emissions and primary carbon metabolism, particularly under the predicted increases in future global temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of the X-ray coherence properties of an undulator beamline at the Advanced Photon Source

In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory to obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator (`pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. The methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mathematical efficiency calibration with uncertain source geometries using smart optimization

The In Situ Object Counting Software (ISOCS), a mathematical method developed by CANBERRA, is a well established technique for computing High Purity Germanium (HPGe) detector efficiencies for a wide variety of source shapes and sizes. In the ISOCS method, the user needs to input the geometry related parameters such as: the source dimensions, matrix composition and density, along with the source-to-detector distance. In many applications, the source dimensions, the matrix material and density may not be well known. Under such circumstances, the efficiencies may not be very accurate since the modeled source geometry may not be very representative of the measured geometry. CANBERRA developed an efficiency optimization software known as 'Advanced ISOCS' that varies the not well known parameters within user specified intervals and determines the optimal efficiency shape and magnitude based on available benchmarks in the measured spectra. The benchmarks could be results from isotopic codes such as MGAU, MGA, IGA, or FRAM, activities from multi-line nuclides, and multiple counts of the same item taken in different geometries (from the side, bottom, top etc). The efficiency optimization is carried out using either a random search based on standard probability distributions, or using numerical techniques that carry out a more directed (referred to as 'smart' in this paper) search. Measurements were carried out using representative source geometries and radionuclide distributions. The radionuclide activities were determined using the optimum efficiency and compared against the true activities. The 'Advanced ISOCS' method has many applications among which are: Safeguards, Decommissioning and Decontamination, Non-Destructive Assay systems and Nuclear reactor outages maintenance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How Humans versus Bots React to Deceptive and Trusted News Sources: A Case Study of Active Users

Society's reliance on social media as a primary source of news has spawned a renewed focus on the spread of misinformation. In this work, we identify the differences in how social media accounts identified as bots react to news sources of varying credibility, regardless of the veracity of the content those sources have shared. We analyze bot and human responses annotated using a fine-grained model that labels responses as being an answer, appreciation, agreement, disagreement, an elaboration, humor, or a negative reaction. We present key findings of our analysis into the prevalence of bots, the variety and speed of bot and human reactions, and the disparity in authorship of reaction tweets between these two sub-populations. We observe that bots are responsible for 9-15% of the reactions to sources of any given type but comprise only 7-10% of accounts responsible for reaction-tweets; trusted news sources have the highest proportion of humans who reacted; bots respond with significantly shorter delays than humans when posting answer-reactions in response to sources identified as propaganda. Finally, we report significantly different inequality levels in reaction rates for accounts identified as bots vs not.

social media, deception↗

Characterization of Persistent Volatile Contaminant Sources in the Vadose Zone

Remediation activities over time will alter the subsurface distribution of contaminants and likely create significant changes in the source-zone architecture. A field method was demonstrated for use of data collected from multiple individual soil vapor extraction (SVE) system well tests to locate and characterize the distribution of persistent VOC sources in the vadose zone. Operational data collected at the Department of Energy’s Hanford site were used to examine source zone alteration over time due to SVE operation and to illustrate the source-zone characterization approach. Individual well test results confirmed a heterogeneous distribution of permeability and contaminant mass discharge throughout the vadose zone. The trends in mass discharge and concentration were analyzed to determine the location and extent of the primary source zone within a lower-permeability unit at the site. This information is useful to evaluate the performance of SVE operations, and support decisions concerning system alteration or closure based on risk assessments of the impact of vadose-zone sources on groundwater contamination or vapor intrusion.

carbon tetrachloride↗

Latest innovations in large area web coating technology via plasma enhanced chemical vapor deposition source technology

In this article, the authors discuss the latest results of our development of large area plasma enhanced chemical vapor deposition (PECVD) source technologies for flexible substrates. A significant challenge is the economical application of thin films for use as vapor barriers, transparent conductive oxides, and optical interference thin films. Here at General Plasma the authors have developed two innovative PECVD source technologies that provide an economical alternative to low temperature sputtering technologies and enable some thin film materials not accessible by sputtering. The Penning Discharge Plasma (PDP trade mark sign ) source is designed for high rate direct PECVD deposition on insulating, temperature sensitive web [J. Modocks, Proceedings of the Society of Vacuum Coaters, 2003 (unpublished), p. 187]. This technology has been utilized to deposit SiO{sub 2} and SiC:H for barrier applications [V. Shamamian et al. Proceedings of the Flexible Displays and Manufacturing Conferrence, 2006 (unpublished)]. The Plasma Beam Source (PBS trade mark sign ) is a remote plasma source that is more versatile for deposition on not only insulating flexible substrates but also conductive or rigid substrates for deposition of thin films that are sensitive to the high ion bombardment flux inherent to the PDP trade mark sign technology. The authors have developed PBS thin film processes in our laboratory for deposition of SiO{sub 2}, SiC:O, SiN:C, SiN:H, ZnO, FeO{sub x}, and Al{sub 2}O{sub 3}. [M. A. George, Conference Proceedings of the Association of Industrial Metallizers, Coaters, and Laminators (AIMCAL), 2007 (unpublished)]. The authors discuss the design of the patented sources, plasma physics, and chemistry of the deposited thin films.

36 MATERIALS SCIENCE↗

EGSnrc Monte Carlo calculated dosimetry parameters for {sup 192}Ir and {sup 169}Yb brachytherapy sources

This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution surrounding a high dose rate {sup 169}Yb brachytherapy source and 14 high dose rate and pulsed dose rate {sup 192}Ir brachytherapy sources. Energy-weighted spectra of emitted photons, a full set of TG-43 dosimetry parameters, along-away dose tables, and a description of the materials and geometry used for each source are provided. In addition to this, separate tallies are made of the dose contributed from primary, single-scattered, and multiply-scattered photons. Separation of dose in this manner allows one to use convolution/superposition methods to calculate the dose surrounding a brachytherapy source accounting for a non-homogeneous medium. The effect of phantom size on TG-43 dosimetry parameters and scattered dose is also investigated for the {sup 192}Ir microSelectron v2 HDR source. This paper describes the calculation methods and presents the dose rate constants calculated for each source with the full set of dosimetry data being available online at the Carleton Laboratory for Radiotherapy Physics brachytherapy database (http://www.physics.carleton.ca/clrp/seed lowbar database/).

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo characterization of a new Yb-169 high dose rate source for brachytherapy application

Purpose: The objective was to characterize a new Yb-169 high dose rate source for brachytherapy application. Methods: Monte Carlo simulations were performed using the MCNP5 F6 energy deposition tallies placed around the Yb-169 source at different radial distances in both air-vacuum and water environments. The calculations were based on a spherical water phantom with a radius of 50 cm. The output from the simulations was converted into radial dose rate distribution in polar coordinates surrounding the brachytherapy source. Results: The results from Monte Carlo simulations were used to calculate the AAPM Task Group 43 dosimetric parameters: Anisotropy function, radial dose function, air kerma strength, and dose rate constant. The results indicate a dose rate constant of 1.12{+-}0.04 cGy h{sup -1} U{sup -1}, anisotropy function ranging from 0.44 to 1.00 for radial distances of 0.5-10 cm and polar angles of 0 deg. - 180 deg. Conclusions: The data from the Yb-169 HDR source, Model M42, presented in this study show that this source compares favorably with another source of Yb-169, Model 4140, already approved for brachytherapy treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-71: Feasibility Study On MRI-Based BANG3 Gel Dosimetry Using Dual-Source Parallel RF Transmission System

Purpose: In this work, we present the feasibility of use of the parallel RF transmission with multiple RF source (MultiTransmit) imaging in MRI-based polymer gel dosimetry. Methods: The commercially available BANG3 gel was used for gel dosimetry. Spin-spin relaxation rate R2 was used to quantify the absorbed dose. The image quality (signal-to-noise ratio, SNR; image uniformity) and B1 field inhomogeneity between conventional single-source and MultiTransmit MR imaging were compared. Finally, the estimated R2 uncertainty σ(R2) and dosimetric performance (i.e., dose resolution) between conventional single-source and MultiTransmit MR imaging were compared. Results: Image quality and B1 field homogeneity within each calibration vial and large phantom was statistically better in MultiTransmit imaging than in conventional single-source RF transmission imaging (P < 0.005 for all calibration vials). In particular, σ(R2) (defined as the standard uncertainty of R2) was lower on the MultiTransmit images than on the conventional single-source images. Furthermore, the MultiTransmit measurement gives a lower than that obtained using the conventional single-source method. Conclusion: The improved image quality and B1 homogeneity resulted in reduced dose uncertainty (i.e., σ(R2) and dose resolution) in MRI-based polymer gel dosimetry, suggesting that MultiTransmit MR imaging has potential benefits for use in clinical 3D gel dosimetry without the need for the complicated B1 field correction method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-102: Determination of Dose Distributions and Water-Equivalence of MAGIC-F Polymer Gel for 60Co and 192Ir Brachytherapy Sources

Purpose: Analyse the water-equivalence of MAGIC-f polymer gel for {sup 60}Co and {sup 192}Ir clinical brachytherapy sources, through dose distributions simulated with PENELOPE Monte Carlo code. Methods: The real geometry of {sup 60} (BEBIG, modelo Co0.A86) and {sup 192}192Ir (Varian, model GammaMed Plus) clinical brachytherapy sources were modelled on PENELOPE Monte Carlo simulation code. The most probable emission lines of photons were used for both sources: 17 emission lines for {sup 192}Ir and 12 lines for {sup 60}. The dose distributions were obtained in a cubic water or gel homogeneous phantom (30 × 30 × 30 cm{sup 3}), with the source positioned in the middle of the phantom. In all cases the number of simulation showers remained constant at 10{sup 9} particles. A specific material for gel was constructed in PENELOPE using weight fraction components of MAGIC-f: wH = 0,1062, wC = 0,0751, wN = 0,0139, wO = 0,8021, wS = 2,58×10{sup −6} e wCu = 5,08 × 10{sup −6}. The voxel size in the dose distributions was 0.6 mm. Dose distribution maps on the longitudinal and radial direction through the centre of the source were used to analyse the water-equivalence of MAGIC-f. Results: For the {sup 60} source, the maximum diferences in relative doses obtained in the gel and water were 0,65% and 1,90%, for radial and longitudinal direction, respectively. For {sup 192}Ir, the maximum difereces in relative doses were 0,30% and 1,05%, for radial and longitudinal direction, respectively. The materials equivalence can also be verified through the effective atomic number and density of each material: Zef-MAGIC-f = 7,07 e .MAGIC-f = 1,060 g/cm{sup 3} and Zef-water = 7,22. Conclusion: The results showed that MAGIC-f is water equivalent, consequently being suitable to simulate soft tissue, for Cobalt and Iridium energies. Hence, gel can be used as a dosimeter in clinical applications. Further investigation to its use in a clinical protocol is needed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-156: Can Sr-90 Check Sources Replace Co-60 Measurements for Monitoring of Reference Chamber Stability?

Purpose: To determine the ultimate precision of a system for monitoring reference-class ion chamber stability using a commercial Sr-90 check source. Methods: A detailed investigation of a commercial Sr-90 check source (PTW48002) was carried out using a series of Farmer-type ionization chambers. Investigations included: positioning repeatability (angular variation as chamber is rotated in source, variation in ionization current with vertical alignment); chamber settling; short and long term repeatability Results: i) Measurement precision – the ionization current was typically 10 pA, and therefore a high-precision electrometer is required to prevent electrometer noise/resolution/leakage biaising the results. ii) Chamber settling - the chamber response stabilizes after approximately 10 minutes, which is longer than reported for linac beams and is likely due to the low doserate of the source.iii) The measured response depended at the 1 % level on the orientation of the chamber with respect to the source. However, consistent positioning resulted in repeatability at the 0.05 % level. Care was also required to ensure that the chamber was consistently positioned vertically with respect to the source. The sensitivity to vertical position was found to be > 1 % per mm.iv)With a uniform procedure the long-term (> 6 month) repeatability was found to be better than 0.1 % for multiple chamber types and potentially a precision of 0.05 % is achievable. Conclusion: A Sr-90 check source is easy to use and is a viable alternative to Co-60 for monitoring reference chamber stability.

60 APPLIED LIFE SCIENCES↗

SU-F-T-24: Impact of Source Position and Dose Distribution Due to Curvature of HDR Transfer Tubes

Purpose: Brachytherapy is a highly targeted from of radiotherapy. While this may lead to ideal dose distributions on the treatment planning system, a small error in source location can lead to change in the dose distribution. The purpose of this study is to quantify the impact on source position error due to curvature of the transfer tubes and the impact this may have on the dose distribution. Methods: Since the source travels along the midline of the tube, an estimate of the positioning error for various angles of curvature was determined using geometric properties of the tube. Based on the range of values a specific shift was chosen to alter the treatment plans for a number of cervical cancer patients who had undergone HDR brachytherapy boost using tandem and ovoids. Impact of dose to target and organs at risk were determined and checked against guidelines outlined by radiation oncologist. Results: The estimate of the positioning error was 2mm short of the expected position (the curved tube can only cause the source to not reach as far as with a flat tube). Quantitative impact on the dose distribution is still in the process of being analyzed. Conclusion: The accepted positioning tolerance for the source position of a HDR brachytherapy unit is plus or minus 1mm. If there is an additional 2mm discrepancy due to tube curvature, this can result in a source being 1mm to 3mm short of the expected location. While we do always attempt to keep the tubes straight, in some cases such as with tandem and ovoids, the tandem connector does not extend as far out from the patient so the ovoid tubes always contain some degree of curvature. The dose impact of this may be significant.

60 APPLIED LIFE SCIENCES↗

SU-G-201-17: Verification of Dose Distributions From High-Dose-Rate Brachytherapy Ir-192 Source Using a Multiple-Array-Diode-Detector (MapCheck2)

Purpose: To investigate quantitatively the accuracy of dose distributions for the Ir-192 high-dose-rate (HDR) brachytherapy source calculated by the Brachytherapy-Planning system (BPS) and measured using a multiple-array-diode-detector in a heterogeneous medium. Methods: A two-dimensional diode-array-detector system (MapCheck2) was scanned with a catheter and the CT-images were loaded into the Varian-Brachytherapy-Planning which uses TG-43-formalism for dose calculation. Treatment plans were calculated for different combinations of one dwell-position and varying irradiation times and different-dwell positions and fixed irradiation time with the source placed 12mm from the diode-array plane. The calculated dose distributions were compared to the measured doses with MapCheck2 delivered by an Ir-192-source from a Nucletron-Microselectron-V2-remote-after-loader. The linearity of MapCheck2 was tested for a range of dwell-times (2–600 seconds). The angular effect was tested with 30 seconds irradiation delivered to the central-diode and then moving the source away in increments of 10mm. Results: Large differences were found between calculated and measured dose distributions. These differences are mainly due to absence of heterogeneity in the dose calculation and diode-artifacts in the measurements. The dose differences between measured and calculated due to heterogeneity ranged from 5%–12% depending on the position of the source relative to the diodes in MapCheck2 and different heterogeneities in the beam path. The linearity test of the diode-detector showed 3.98%, 2.61%, and 2.27% over-response at short irradiation times of 2, 5, and 10 seconds, respectively, and within 2% for 20 to 600 seconds (p-value=0.05) which depends strongly on MapCheck2 noise. The angular dependency was more pronounced at acute angles ranging up to 34% at 5.7 degrees. Conclusion: Large deviations between measured and calculated dose distributions for HDR-brachytherapy with Ir-192 may be improved when considering medium heterogeneity and dose-artifact of the diodes. This study demonstrates that multiple-array-diode-detectors provide practical and accurate dosimeter to verify doses delivered from the brachytherapy Ir-192-source.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-11: Moving a GPU-OpenCL-Based Monte Carlo (MC) Dose Engine Towards Routine Clinical Use: Automatic Beam Commissioning and Efficient Source Sampling

Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculations for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

Source apportionment of circum-Arctic atmospheric black carbon from isotopes and modeling

Black carbon (BC) contributes to Arctic climate warming, yet source attributions are inaccurate due to lacking observational constraints and uncertainties in emission inventories. Year-round, isotope-constrained observations reveal strong seasonal variations in BC sources with a consistent and synchronous pattern at all Arctic sites. These sources were dominated by emissions from fossil fuel combustion in the winter and by biomass burning in the summer. The annual mean source of BC to the circum-Arctic was 39 ± 10% from biomass burning. Comparison of transport-model predictions with the observations showed good agreement for BC concentrations, with larger discrepancies for (fossil/biomass burning) sources. The accuracy of simulated BC concentration, but not of origin, points to misallocations of emissions in the emission inventories. The consistency in seasonal source contributions of BC throughout the Arctic provides strong justification for targeted emission reductions to limit the impact of BC on climate warming in the Arctic and beyond.

54 ENVIRONMENTAL SCIENCES↗

Electromagnetic radiation from filamentary sources in the presence of axially magnetized cylindrical plasma scatterers

Electromagnetic radiation from filamentary electric-dipole and magnetic-current sources of infinite length in the presence of gyrotropic cylindrical scatterers in the surrounding free space is studied. The scatterers are assumed to be infinitely long, axially magnetized circular plasma columns parallel to the axis of the filamentary source. The field and the radiation pattern of each source are calculated in the case where the source frequency is equal to one of the surface plasmon resonance frequencies of the cylindrical scatterers. It is shown that the presence of even a single resonant magnetized plasma scatterer of small electrical radius or a few such scatterers significantly affects the total fields of the filamentary sources, so that their radiation patterns become essentially different from those in the absence of scatterers or the presence of isotropic scatterers of the same shape and size. It is concluded that the radiation characteristics of the considered sources can efficiently be controlled using their resonance interaction with the neighboring gyrotropic scatterers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An explainable variational autoencoder model for three-dimensional acoustic emission source localization in hollow cylindrical structures

We introduce an explainable variational autoencoder for three-dimensional (3D) localization of acoustic emission sources in hollow cylindrical structures, with an unsupervised approach. This research capitalizes on multi-arrival waveforms generated by helical path propagation in cylindrical geometries to enable efficient two-receiver localization. By integrating the modal characteristics of Lamb modes under multi-path conditions, we demonstrate that two sets of time-of-arrival differences and peak amplitudes extracted from one receiver can serve as effective localization features. This initial approach identifies four potential source locations, highlighting the feasibility of two-receiver source localization using traditional feature extraction methods. However, direct extraction can be challenging when mode overlaps occur, complicating the localization process. To address this, our work proposes a novel waveform-based method. This method leverages the consistent dispersion characteristics within isotropic materials, where each unique combination of mode arrival times and peak amplitudes constructs a distinct waveform. This distinctiveness overcomes the ambiguities associated with mode overlaps, significantly enhancing the method’s precision and robustness. Our approach adopts a data-driven strategy for waveform-based localization using variational autoencoder (VAE). VAE discerns waveform patterns for localization, while also addressing data uncertainties. The VAE’s encoder and decoder networks capture the localization process and the source’s influence on waveform generation, respectively, guiding latent variables to segregate waveforms by source in the latent space. The design of the learning process focuses on specific localization characteristics to enhance result explainability. Localization predictions are generated by projecting test waveforms, not included in the training set, onto a trained latent space. The prediction is determined using a nearest-neighbor approach based on the closest latent representation of a source. Validation with pencil-lead-break tests on a metallic pipe confirmed our method’s effectiveness, achieving an averaged 3D localization accuracy of 0.84.

Lee, Guan-Wei↗

Computational Assessment of Naturally Occurring Neutron and Photon Background Radiation Produced by Extraterrestrial Sources

In this study, a computational assessment of the variation in terrestrial neutron and photon background from extraterrestrial sources is presented. The motivation of this assessment is to evaluate the practicality of developing a tool or database to estimate background in real time (or near–real time) during an experimental measurement or to even predict the background for future measurements. The extraterrestrial source focused on during this assessment is naturally occurring galactic cosmic rays (GCRs). The MCNP6 transport code was used to perform the computational assessment. However, the GCR source available in MCNP6 was not used. Rather, models developed and maintained by NASA were used to generate the GCR sources. The largest variation in both neutron and photon background spectra was found to be caused by changes in elevation on Earth's surface, which can be as large as an order of magnitude. All other perturbations produced background variations on the order of a factor of 3 or less. The most interesting finding was that ~80% and 50% of terrestrial background neutrons and photons, respectively, are generated by interactions in Earth's surface and other naturally occurring and man-made objects near a detector of particles from extraterrestrial sources and their progeny created in Earth's atmosphere. In conclusion, this assessment shows that it will be difficult to estimate the terrestrial background from extraterrestrial sources without a good understanding of a detector's surroundings. Therefore, estimating or predicting background during a measurement environment like a mobile random search will be difficult.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗