Idaho National Laboratory Materials and Fuels Complex Natural Phenomena Hazards Flood Assessment

This report presents the results of flood hazards analyses performed for the Materials and Fuels Complex (MFC) and the adjacent Transient Reactor Experiment and Test Facility (TREAT) located at Idaho National Laboratory. The requirements of these analyses are provided in the U.S. Department of Energy Order 420.1B and supporting Department of Energy (DOE) Natural Phenomenon Hazard standards. The flood hazards analyses were performed by Battelle Energy Alliance and Pacific Northwest National Laboratory. The analyses addressed the following: • Determination of the design basis flood (DBFL) • Evaluation of the DBFL versus the Critical Flood Elevations (CFEs) for critical existing structures, systems, and components (SSCs).

99 GENERAL AND MISCELLANEOUS↗

Commentary on A Conceptual Design of Transport Lines for a Heavy-Ion Inertial-Fusion Power Plant

Some major system features are not stated but can be inferred. For example this is probably an engineering test facility, not a power plant driver, because the standoff from target to final magnet is only 5.0 m. The fusion target takes two-sided illumination with indirect drive using a total of 60 beam pulses: 10 pre-pulses (3.0 GeV) + 20 main pulses (4.0 GeV) from each side. On page 12 it's stated that the charge per beam pulse is 26.8 {micro}C, so we calculate pre-pulse: 20 x 3 GeV x 26.8 {micro}C = 1.608MJ, main pulse: 40 x 4 GeV x 26.8 {micro}C = 4.288MJ, total beam energy 5.896MJ. The beam ion mass ks 200 amu, so the species is Hg{sup +}. Therefore the mid-pulse velocities are: pre-pulse v = .1773c = 5.316 x 10{sup 7} m/s, main pulse v = .2040c = 6.114 x 10{sup 7} m/s, On page 12 it is stated that the pre-compression pulse length is L{sub 0} = 10.0m, and compression is by a 'factor of order 20'. They infer a final pulse length of about .5 m and final durations pre-pulse {tau} {approx} .5/5.316 x 10{sup 7} = 9.4 ns; main pulse {tau} {approx} .5/6.114 x 10{sup 7} = 8.2 ms. The magnetic rigidity of the beam ions is [B{rho}] = {gamma}m v/e = {l_brace} 112.0 T-m - prepulse/129.5 T-m - mainpulse{r_brace}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Literature Review on the Effects of Prescription Fire on theEcology of Site 300

Lawrence Livermore National Laboratory has historically conducted prescription burns across approximately 2,000 acres of Site 300 on an annual basis to safeguard test facilities and operations from the risk of wildfire encroachment. Prescription burns began in 1960, and although fire frequency varies among the designated burn areas, all have been burned at least once. A patchwork of native perennial grassland communities and associated special-status plant and animal populations occur onsite in many areas that have been receiving these treatments. Because the size and locations of prescription burns may shift in coming years, an evaluation is warranted to determine how these shifts may affect listed biota, including rare plants, and the distinct ecological conditions present on the site. This report presents the results of a literature review conducted by ICF International (ICF) to collect basic information on native perennial grasslands in California, the influence of fire on these grasslands, and management tools for restoring and maintaining them. The objective of this study was to review the scientific literature on California native grasslands and summarize the current state of knowledge pertaining to the possible effects -- both beneficial and detrimental -- of prescribed fire on the ecology of Site 300. The results of this review are intended to inform future management practices that may be carried out at Site 300 to maintain the plant and wildlife communities and to ensure that the ecological conditions benefit the special-status species that inhabit the Site. This review is also intended to identify a study approach to investigate changes over the next 10 years in the burned areas and in areas where burning will be discontinued.

54 ENVIRONMENTAL SCIENCES↗

Data Collection Plan to Populate the Light Water Reactor Sustainability Failure Mode Degradation Library

Interest in implementing advanced Prognostic Health Management (PHM) systems in commercial nuclear power plants (NPPs) has increased rapidly in recent years, with an overarching goal of implementing of improving the safety, reliability, and economics/profitability of the aging nuclear fleet and extending their service life in the most cost-effective manner. The PHM system utilizes prognostic tools to estimate the remaining useful life (RUL) of a component or system of components based on current and predicted operating conditions. An effective implementation of the PHM system will anticipate and identify unique age-dependent degradation modes to provide early warning of emerging problems. Selection of the components and structures to be monitored is a crucial step for successful PHM implementation in NPPs. A selection framework is recommended for risk significant components (both safety-related and non-safety related) based on the Fussell-Vesely (F-V) Importance Measure and the Risk Achievement Worth (RAW) measure. For the selected components, a failure mode degradation library will be developed consisting of data corresponding to different failure/degradation modes. In lieu of constructing an expensive scaled test facility, several data sources are identified for populating the failure mode degradation library, including various national laboratories, universities, agencies, and industries.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes

This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new manufactured homes procured with minimal energy-efficiency specifications typical of existing homes in the region, and sited on the PNNL campus. The Lab Homes serve as a flexible test facility (the first of its kind in the Pacific Northwest) to rapidly evaluate energy-efficient and grid-smart technologies that are applicable to residential construction.

54 ENVIRONMENTAL SCIENCES↗

NWTC Controllable Grid Interface (Fact Sheet)

NREL's Controllable Grid Interface tests wind turbines off-line from the grid, verifies compliance with standards, and provides grid operators with the performance information they need for a faction of the time and cost it would take to test the turbine in the field.

17 WIND ENERGY↗

Reflector Technology Development and System Design for Concentrating Solar Power Technologies

Alcoa began this program in March of 2008 with the goal of developing and validating an advanced CSP trough design to lower the levelized cost of energy (LCOE) as compared to existing glass based, space-frame trough technology. In addition to showing a pathway to a significant LCOE reduction, Alcoa also desired to create US jobs to support the emerging CSP industry. Alcoa's objective during Phase I: Concept Feasibility was to provide the DOE with a design approach that demonstrates significant overall system cost savings without sacrificing performance. Phase I consisted of two major tasks; reflector surface development and system concept development. Two specific reflective surface technologies were investigated, silver metallized lamination, and thin film deposition both applied on an aluminum substrate. Alcoa prepared samples; performed test validation internally; and provided samples to the NREL for full-spectrum reflectivity measurements. The final objective was to report reflectivity at t = 0 and the latest durability results as of the completion of Phase 1. The target criteria for reflectance and durability were as follows: (1) initial (t = 0), hemispherical reflectance >93%, (2) initial spectral reflectance >90% for 25-mrad reading and >87% for 7-mrad reading, and (3) predicted 20 year durability of less than 5% optical performance drop. While the results of the reflective development activities were promising, Alcoa was unable to down-select on a reflective technology that met the target criteria. Given the progress and potential of both silver film and thin film technologies, Alcoa continued reflector surface development activities in Phase II. The Phase I concept development activities began with acquiring baseline CSP system information from both CSP Services and the DOE. This information was used as the basis to develop conceptual designs through ideation sessions. The concepts were evaluated based on estimated cost and high-level structural performance. The target criteria for the concept development was to achieve a solar field cost savings of 25%-50% thereby meeting or exceeding the DOE solar field cost savings target of $\$$350/m 2 . After evaluating various structural design approaches, Alcoa down-selected to a monocoque, dubbed Wing Box, design that utilizes the reflective surface as a structural, load carrying member. The cost and performance potential of the Wing Box concept was developed via initial finite element analysis (FEA) and cost modeling. The structural members were sized through material utilization modeling when subjected to representative loading conditions including wind loading. Cost modeling was utilized to refine potential manufacturing techniques that could be employed to manufacture the structural members. Alcoa concluded that an aluminum intensive collector design can achieve significant cost savings without sacrificing performance. Based on the cost saving potential of this Concept Feasibility study, Alcoa recommended further validation of this CSP approach through the execution of Phase II: Design and Prototype Development. Alcoa Phase II objective was to provide the DOE with a validated CSP trough design that demonstrates significant overall system cost savings without sacrificing performance. Phase II consisted of three major tasks; Detail System Design, Prototype Build, and System Validation. Additionally, the reflector surface development that began in Phase I was continued in Phase II. After further development work, Alcoa was unable to develop a reflective technology that demonstrated significant performance or cost benefits compared to commercially available CSP reflective products. After considering other commercially available reflective surfaces, Alcoa selected Alano's MIRO-SUN product for use on the full scale prototype. Although MIRO-SUN has a lower specular reflectivity compared to other options, its durability in terms of handling, cleaning, and long-term reflectivity was deemed the most important attribute to successfully validate Alcoa's advanced trough architecture. To validate the performance of the Wing Box trough, a 6 meter aperture by 14 meter long prototype trough was built. For ease of shipping to and assembly at NREL's test facility, the prototype was fabricated in two half modules and joined along the centerline to create the Wing Box trough. The trough components were designed to achieve high precision of the reflective surface while leveraging high volume manufacturing and assembly techniques.

14 SOLAR ENERGY↗

Shock-driven fluid-structure interaction for civil design

The multiphysics fluid-structure interaction simulation of shock-loaded structures requires the dynamic coupling of a shock-capturing flow solver to a solid mechanics solver for large deformations. The Virtual Test Facility combines a Cartesian embedded boundary approach with dynamic mesh adaptation in a generic software framework of flow solvers using hydrodynamic finite volume upwind schemes that are coupled to various explicit finite element solid dynamics solvers (Deiterding et al., 2006). This paper gives a brief overview of the computational approach and presents first simulations that utilize the general purpose solid dynamics code DYNA3D for complex 3D structures of interest in civil engineering. Results from simulations of a reinforced column, highway bridge, multistory building, and nuclear reactor building are presented.

42 ENGINEERING↗

A Comparison of "Total Dust" and Inhalable Personal Sampling for Beryllium Exposure

In 2009, the American Conference of Governmental Industrial Hygienists (ACGIH) reduced the Beryllium (Be) 8-hr Time Weighted Average Threshold Limit Value (TLV-TWA) from 2.0 μg/m 3 to 0.05 μg/m 3 with an inhalable 'I' designation in accordance with ACGIH's particle size-selective criterion for inhalable mass. Currently, per the Department of Energy (DOE) requirements, the Lawrence Livermore National Laboratory (LLNL) is following the Occupational Health and Safety Administration (OSHA) Permissible Exposure Limit (PEL) of 2.0 μg/m 3 as an 8-hr TWA, which is also the 2005 ACGIH TLV-TWA, and an Action Level (AL) of 0.2 μg/m 3 and sampling is performed using the 37mm (total dust) sampling method. Since DOE is considering adopting the newer 2009 TLV guidelines, the goal of this study was to determine if the current method of sampling using the 37mm (total dust) sampler would produce results that are comparable to what would be measured using the IOM (inhalable) sampler specific to the application of high energy explosive work at LLNL's remote experimental test facility at Site 300. Side-by-side personal sampling using the two samplers was performed over an approximately two-week period during chamber re-entry and cleanup procedures following detonation of an explosive assembly containing Beryllium (Be). The average ratio of personal sampling results for the IOM (inhalable) vs. 37-mm (total dust) sampler was 1.1:1 with a P-value of 0.62, indicating that there was no statistically significant difference in the performance of the two samplers. Therefore, for the type of activity monitored during this study, the 37-mm sampling cassette would be considered a suitable alternative to the IOM sampler for collecting inhalable particulate matter, which is important given the many practical and economic advantages that it presents. However, similar comparison studies would be necessary for this conclusion to be applied to other types of activities, where earlier studies have shown that the IOM sampler tends to collect higher concentrations of Be compared to the 37-mm cassette, which could complicate compliance with what is already an extremely low exposure limit.

99 GENERAL AND MISCELLANEOUS↗

High-Temperature Split-Flow Recompression Brayton Cycle Initial Test Results

Supercritical CO 2 (S-CO 2 ) power plants offer the potential for better economics because of their small size, use of standard materials, and improved electrical power conversion efficiency at modest temperature (400–750°C). Sandia National Laboratories (SNL or Sandia) and the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) are operating a supercritical CO 2 Brayton cycle power system—the Generation IV (Gen IV) split-flow S-CO 2 compressor test loop—currently located in Arvada Colorado, at Barber Nichols, Inc., under contract to Sandia. A photograph of the upgraded loop is shown in Figure E-1. This system is one of the first S-CO 2 power-producing Brayton cycles operating in the world. This report provides a summary of the newly installed hardware and briefly describes some of the test results that were performed in the upgraded split-flow Brayton loop during June and July of 2011. The Gen IV S-CO 2 split-flow Brayton loop was reconfigured to operate as a simple heated recuperated Brayton loop for the testing in this report period. The test loop had just concluded a phase of construction that substantially increased the capability of the loop by adding heaters, a high-temperature (HT) recuperator, more waste heat removal capability, high-power load banks, larger diameter piping with more bends to reduce thermal stress, and more capable scavenging pumps to reduce windage and friction within the turbomachinery and provide greater cooling capabilities. With these additions, the loop greatly increased its capacity for electrical power generation (30–80 kWe per generator, depending on the loop configuration) and its ability to reach high temperatures (up to 810 K [1000°F]). In recent weeks of testing, the test facility began to realize this potential by achieving new records in turbine inlet temperature (615 K [650°F]), shaft speed (52,000 rpm), pressure ratio (1.65), flow rate (2.7 kg/s), and electrical power generated (20 kWe). These operating conditions still remain short of design conditions for each turbine—an inlet temperature of 810 K (1000°F), a pressure ratio of 1.8, a shaft speed of 75,000 rpm, a flow rate of 3.5 kg/s, and a maximum generator power of 125 kWe—but they are beginning to be approached. Not all planned upgrades were implemented due to the limited funding profile of FY2010. Only 520 kW of heater power were installed—not the total 780 kW. Furthermore, because one of the heater controllers was not functioning, only 390 kW of heater power were available. Similarly, the 3-in. piping was installed only in the high-pressure leg of the loop, not in the low-pressure leg, as was originally planned. We also had to rely on the new load bank capability for rapid shutdown situations, and were not able to install a dedicated shutdown resistor. Nevertheless, in spite of these limitations, we operated the loop at record operating conditions and were largely limited only by the facility and support equipment—not the turbomachinery.

Wright, Steven Alan↗

Oxygen-Fired CO 2 Recycle for Application to Direct CO 2 Capture form Coal-Fired Power Plants

The Southern Research/Southern Company 1 MWth Pilot-Scale Coal-Fired Test Facility was successfully retrofit to fire in either the traditional air-fired mode or with 100% oxygen and recycled flue gas, with a fully integrated feedback and control system, including oxygen and recycled flue gas modulation during startup, transfer, and shutdown, safety and operational interlocks, and data acquisition. A MAXON Staged Oxygen Burner for Oxy-Coal Applications produced a stable flame over a significant range of firing turn-down, staging, and while firing five different U.S. coal types. The MAXON burner design produces lower flame temperatures than for air firing, which will enable (A) Safe operation, (B) Reduction of recycle flow without concern about furnace flame temperatures, and (C) May likely be affective at reducing slagging and fouling in the boiler and super heater at full-scale Power Plants. A CFD model of the Oxy-fired Combustion Research Facility (OCRF) was used to predict the flame geometry and temperatures in the OCRF and make a comparison with the air-fired case. The model predictions were consistent with the experimental data in showing that the MAXON burner fired with oxygen produced lower flame temperatures than the air-fired burner while firing with air.

01 COAL, LIGNITE, AND PEAT↗

Temperature and Burnup Correlated FCCI in U-10Zr Metallic Fuel

Metallic fuels are proposed for use in advanced sodium cooled fast reactors. The experience basis for metallic fuels is extensive and includes development and qualification of fuels for the Experimental Breeder Reactor I, the Experimental Breeder Reactor II, FERMI-I, and the Fast Flux Test Facility (FFTF) reactors. Metallic fuels provide a number of advantages over other fuel types in terms of fabricability, performance, recyclability, and safety. Key to the performance of all nuclear fuel systems is the resistance to “breach” and subsequent release of fission products and fuel constituents to the primary coolant system of the nuclear power plant. In metallic fuel, the experience is that significant fuel-cladding chemical (FCCI) interaction occurs and becomes prevalent at high power-high temperature operation and ultimately leads to fuel pin breach and failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HTTF Core Stress Analysis

In accordance with the need to determine whether cracking of the ceramic core disks which will be constructed and used in the High Temperature Test Facility (HTTF) for heatup and cooldown experiments, a set of calculation were performed using Abaqus to investigate the thermal stresses levels and likelihood for cracking. The calculations showed that using the material properties provided for the Greencast 94F ceramic, cracking is predicted to occur. However, this modeling does not predict the size or length of the actual cracks. It is quite likely that cracks will be narrow with rough walls which would impede the flow of coolant gases entering the cracks. Based on data recorded at Oregon State University using Greencast 94F samples that were heated and cooled at prescribed rates, it was concluded that the likelihood that the cracks would be detrimental to the experimental objectives is small.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of HQ01e magnetic measurements

The magnetic measurements of HQ01e, a 1 m long LHC Accelerator Research Program (LARP) high-gradient quadrupole model, were performed at 4.4 K and above 40 K at the magnet test facility of LBNL in July 2011. The 120 mm aperture cos2 θ Nb 3 Sn magnet was designed with accelerator magnet features including alignment and field quality. Conductor-limited gradient was 195 T/m at 4.4 K. During the measurement, a ramp rate of 10 A/s was used and measurements at the nominal current of 14.2 kA (82% of short-sample limit with a gradient of 160 T/m) were performed using the 250 mm long printed-circuit board rotating probe developed by FNAL. At 14.2 kA, 2.7 units of b 6 and 0.7 units of b 10 were measured. Large persistent current contribution and strong dynamic effects were observed.

43 PARTICLE ACCELERATORS↗

Energy Recovery Linac: 5 Cell 704 MHz SRF Cavity

One of the key components for the superconducting RF Energy Recovery Linac, (ERL) under development in the Collider Accelerator Department at Brookhaven National Laboratory, is the Linac cavity and cryomodule. The cavity is a 5 cell accelerating cavity designed to operate at 703.75 MHz, and to accelerate 2 MeV electrons from the photoinjector up to 15-20 MeV, allow them to make a single pass around the ERL loop and then decelerate them back down to 2 MeV prior to sending them to the beam dump. This cavity was designed by Rama Calaga and Ilan Ben-Zvi at BNL and fabricated by Advanced Energy Systems in Medford, NY. The cavity was then delivered to Thomas Jefferson Laboratory in VA for chemical processing, testing and assembly of the hermetic string assembly suitable for shipment back to BNL. Once at BNL it was built into a complete cryomodule, installed in the ERL test facility and commissioned. This paper will review the key components of the cavity and cryomodule and discuss the present status of the cryomodule commissioning.

43 PARTICLE ACCELERATORS↗

Novel Polymer Membrane Process for Pre-Combustion CO 2 Capture from Coal-Fired Syngas

This final report describes work conducted for the Department of Energy (DOE NETL) on development of a novel polymer membrane process for pre-combustion CO 2 capture from coalfired syngas (award number DE-FE0001124). The work was conducted by Membrane Technology and Research, Inc. (MTR) from September 15, 2009, through December 14, 2011. Tetramer Technologies, LLC (Tetramer) was our subcontract partner on this project. The National Carbon Capture Center (NCCC) at Wilsonville, AL, provided access to syngas gasifier test facilities. The main objective of this project was to develop a cost-effective membrane process that could be used in the relatively near-term to capture CO 2 from shifted syngas generated by a coal-fired Integrated Gasification Combined Cycle (IGCC) power plant.