Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Electron self-injection in the proton-driven-plasma-wakefield acceleration

The self-injection process of plasma electrons in the proton-driven-plasma-wakefield acceleration scheme is investigated using a two-dimensional, electromagnetic particle-in-cell method. Plasma electrons are self-injected into the back of the first acceleration bucket during the initial bubble formation period, where the wake phase velocity is low enough to trap sufficient electrons. Most of the self-injected electrons are initially located within a distance of the skin depth c/ω{sub pe} to the beam axis. A decrease (or increase) in the beam radius (or length) leads to a significant reduction in the total charges of self-injected electron bunch. Compared to the uniform plasma, the energy spread, emittance and total charges of the self-injected bunch are reduced in the plasma channel case, due to a reduced injection of plasma electrons that initially located further away from the beam axis.

43 PARTICLE ACCELERATORS↗

Galactic Potential and Dark Matter Density from Angular Stellar Accelerations

Here, we present an approach to measure the Milky Way (MW) potential using the angular accelerations of stars in aggregate as measured by astrometric surveys like Gaia. Accelerations directly probe the gradient of the MW potential, as opposed to indirect methods using, e.g., stellar velocities. We show that end-of-mission Gaia stellar acceleration data may be used to measure the potential of the MW disk at approximately 3σ significance and, if recent measurements of the solar acceleration are included, the local dark matter density at ~2σ significance. Since the significance of detection scales steeply as t 5/2 for observing time t, future surveys that include angular accelerations in the astrometric solutions may be combined with Gaia to precisely measure the local dark matter density and shape of the density profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Shielding Experiments Under JASMIN Collaboration at Fermilab(III) - Measurement of High-Energy Neutrons Penetrating a Thick Iron Shield from the Antiproton Production Target by AU Activation Method

In an antiproton production (Pbar) target station of the Fermi National Accelerator Laboratory (FNAL), the secondary particles produced by bombarding a target with 120-GeV protons are shielded by a thick iron shield. In order to obtain experimental data on high-energy neutron transport at more than 100-GeV-proton accelerator facilities, we indirectly measured more than 100-MeV neutrons at the outside of the iron shield at an angle of 50{\deg} in the Pbar target station. The measurement was performed by using the Au activation method coupled with a low-background {\gamma}-ray counting system. As an indicator for the neutron flux, we determined the production rates of 8 spallation nuclides (196-Au, 188-Pt, 189-Ir, 185-Os, 175-Hf, 173-Lu, 171-Lu, and 169-Yb) in the Au activation detector. The measured production rates were compared with the theoretical production rates calculated using PHITS. We proved that the Au activation method can serve as a powerful tool for indirect measurements of more than 100-MeV neutrons that play a vital role in neutron transport. These results will be important for clarifying the problems in theoretical calculations of high-energy neutron transport.

43 PARTICLE ACCELERATORS↗

Population transfer HMQC for half-integer quadrupolar nuclei

This work presents a detailed analysis of a recently proposed nuclear magnetic resonance method [Wang et al., Chem. Commun. 49(59), 6653-6655 (2013)] for accelerating heteronuclear coherence transfers involving half-integer spin quadrupolar nuclei by manipulating their satellite transitions. This method, called Population Transfer Heteronuclear Multiple Quantum Correlation (PT-HMQC), is investigated in details by combining theoretical analyses, numerical simulations, and experimental investigations. We find that compared to instant inversion or instant saturation, continuous saturation is the most practical strategy to accelerate coherence transfers on half-integer quadrupolar nuclei. We further demonstrate that this strategy is efficient to enhance the sensitivity of J-mediated heteronuclear correlation experiments between two half-integer quadrupolar isotopes (e.g., {sup 27}Al-{sup 17}O). In this case, the build-up is strongly affected by relaxation for small T{sub 2}′ and J coupling values, and shortening the mixing time makes a huge signal enhancement. Moreover, this concept of population transfer can also be applied to dipolar-mediated HMQC experiments. Indeed, on the AlPO{sub 4}-14 sample, one still observes experimentally a 2-fold shortening of the optimum mixing time albeit with no significant signal gain in the {sup 31}P-({sup 27}Al) experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pseudo-random number generation for Brownian Dynamics and Dissipative Particle Dynamics simulations on GPU devices

Highlights: {yields} Molecular Dynamics codes implemented on GPUs have achieved two-order of magnitude computational accelerations. {yields} Brownian Dynamics and Dissipative Particle Dynamics simulations require a large number of random numbers per time step. {yields} We introduce a method for generating small batches of pseudorandom numbers distributed over many threads of calculations. {yields} With this method, Dissipative Particle Dynamics is implemented on a GPU device without requiring thread-to-thread communication. - Abstract: Brownian Dynamics (BD), also known as Langevin Dynamics, and Dissipative Particle Dynamics (DPD) are implicit solvent methods commonly used in models of soft matter and biomolecular systems. The interaction of the numerous solvent particles with larger particles is coarse-grained as a Langevin thermostat is applied to individual particles or to particle pairs. The Langevin thermostat requires a pseudo-random number generator (PRNG) to generate the stochastic force applied to each particle or pair of neighboring particles during each time step in the integration of Newton's equations of motion. In a Single-Instruction-Multiple-Thread (SIMT) GPU parallel computing environment, small batches of random numbers must be generated over thousands of threads and millions of kernel calls. In this communication we introduce a one-PRNG-per-kernel-call-per-thread scheme, in which a micro-stream of pseudorandom numbers is generated in each thread and kernel call. These high quality, statistically robust micro-streams require no global memory for state storage, are more computationally efficient than other PRNG schemes in memory-bound kernels, and uniquely enable the DPD simulation method without requiring communication between threads.

97 MATHEMATICS AND COMPUTING↗

Predictors for Clinical Outcomes After Accelerated Partial Breast Intensity-Modulated Radiotherapy

Purpose: To correlate the treatment planning parameters with the clinical outcomes in patients treated with accelerated partial breast intensity-modulated radiotherapy. Methods and Materials: A total of 105 patients with Stage I breast cancer were treated between February 2004 and March 2007 in a Phase II prospective trial and had detailed information available on the planning target volume (PTV), ipsilateral breast volume (IBV), PTV/IBV ratio, lung volume, chest wall volume, surgery to radiotherapy interval, follow-up interval, breast pain, and cosmesis. The first 7 of these patients were treated to 34 Gy, and the remaining 98 were treated to 38.5 Gy. All patients were treated twice daily for 5 consecutive days. Univariate and multivariate analyses were performed. Results: The median follow-up was 13 months. No recurrences or deaths were observed. Of the 105 patients, 30 reported mild or moderate breast pain in their most recently recorded follow-up visit. The irradiated lung volume (p < 0.05) and chest wall volume receiving >35 Gy (p < 0.01) were associated with pain. The PTV, but not the PTV/IBV ratio, also correlated with pain (p < 0.01 and p = 0.42, respectively). A total of 72 patients reported excellent, 32 reported good, and 1 reported poor cosmesis. Physician-rated cosmesis reported 90 excellent and 15 good. None of the tested variables correlated with the cosmetic outcomes. Conclusion: Radiotherapy to the chest wall (chest wall volume receiving >35 Gy) and to lung correlated with reports of mild pain after accelerated partial breast intensity-modulated radiotherapy. Also, the PTV, but not the PTV/IBV ratio, was predictive of post-treatment reports of pain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Excitation of {sup 111m}Cd, {sup 113m}In, and {sup 115m}In isomeric states by photons of energy up to 8 MeV

Experimental results on the excitation of isomeric nuclear states in the reactions {sup 111}Cd(γ, γ′){sup 111m}Cd, {sup 113}In(γ, γ′){sup 113m}In, and {sup 115}In(γ, γ′){sup 115m}In studied by the activation method at photon energies of up to 8 MeV are presented. The respective experiments were performed at the LUE-8 linear electron accelerator of the Institute for Nuclear Research (INR, Moscow). A method for calculating cross sections per equivalent photon was developed with the aid of a simulation on the basis of the GEANT-4 code. The data obtained in this way are discussed from the point of view of the possibility of studying collective nuclear excitations of various multipolarity near the threshold.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-547: Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/stereotactic Body Radiotherapy

Purpose: To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. Methods: We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provide a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. We investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. Results: For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm; at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off-isocenter, the deviation was below 1 mm; at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which is 72% higher than the tolerance threshold. Conclusion: These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in of our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to design the treatment plan.

60 APPLIED LIFE SCIENCES↗

HyKKT: a hybrid direct-iterative method for solving KKT linear systems

Here, we propose a solution strategy for the large indefinite linear systems arising in interior methods for nonlinear optimization. The method is suitable for implementation on hardware accelerators such as graphical processing units (GPUs). The current gold standard for sparse indefinite systems is the LBLT factorization where L is a lower triangular matrix and B is 1×1 or 2×2 block diagonal. However, this requires pivoting, which substantially increases communication cost and degrades performance on GPUs. Our approach solves a large indefinite system by solving multiple smaller positive definite systems, using an iterative solver on the Schur complement and an inner direct solve (via Cholesky factorization) within each iteration. Cholesky is stable without pivoting, thereby reducing communication and allowing reuse of the symbolic factorization. We demonstrate the practicality of our approach on large optimal power flow problems and show that it can efficiently utilize GPUs and outperform LBL T factorization of the full system.

97 MATHEMATICS AND COMPUTING↗

Muons in minimum bias events from the first CMS data

Muon signatures are extremely important in the challenging environment of collisions at the LHC. Understanding the observed muon yield from Standard Model processes is the first task for all analyses involving muons. Basic muon kinematical observables are presented for the first CMS data at {radical}(s) = 7 TeV and compared with Monte Carlo expectations. The muon sample composition is studied by using the MC truth in terms of muons from heavy flavours, muons from light hadron decays and hadron punch-through is studied from MC truth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Monte Carlo volumetric-ray-casting estimator for global fluence tallies on GPUs

A Monte Carlo fluence estimator has been designed to take advantage of the computational power of graphical processing units (GPUs). This new estimator, termed the volumetric-ray-casting estimator, is an extension of the expectation estimator. It can be used as a replacement of the track-length estimator for the estimation of global fluence. Calculations for this estimator are performed on the GPU while the Monte Carlo random walk is performed on the central processing unit (CPU). This method lowers the implementation cost for GPU acceleration of existing Monte Carlo particle transport codes as there is little modification of the particle history logic flow. Three test problems have been evaluated to assess the performance of the volumetric-ray-casting estimator for neutron transport on GPU hardware in comparison to the standard track-length estimator on CPU hardware. Evaluation of neutron transport through air in a criticality accident scenario showed that the volumetric-ray-casting estimator achieved 23 times the performance of the track-length estimator using a single core CPU paired with a GPU and 15 times the performance of the track-length estimator using an eight core CPU paired with a GPU. Finally, simulation of a pressurized water reactor fuel assembly showed that the performance improvement was 6 times within the fuel and 7 times within the control rods using an eight core CPU paired with a single GPU.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Accelerator Design Progress for EIC Strong Hadron Cooling

The Electron-Ion Collider will achieve a luminosity of 1034 cm-2 s-1 by incorporating strong hadron cooling to counteract hadron Intra-Beam Scattering, using a coherent electron cooling scheme. An accelerator will deliver the beams with key parameters, such as 1 nC bunch charge, and 1e-4 energy spread. The paper presents the design and beam dynamics simulation results. Methods to minimize beam noise, the challenges of the accelerator design, and the R&D topics being pursued are discussed.

Wang, E.↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. The system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems and in required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled, multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems and the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

43 PARTICLE ACCELERATORS↗

Low level coupling scheme between neutronics and thermal-hydraulics based on Anderson acceleration

The simulation of nuclear reactors is a multiphysics problem mixing, amongst other fields, neutron transport and thermal-hydraulics. The simplest and most used approach in multiphysics simulation is based on the coupling of single-physics codes in a black-box fashion. However, in order to reduce the computational time needed for such simulations, case-dependent optimizations are often required. In this paper, we aim at reducing the computational time required to solve a coupled neutronic/thermal-hydraulic steady-state problem on a simplified Pressurized Water Reactor (PWR) core. The idea is to deal simultaneously with the coupling of the energy groups of the deterministic neutronic description of the core and its thermal-hydraulic description with the Anderson acceleration. By doing so, the fission source terms are directly accelerated instead of the power map as done in most cases. The power method used to solve the k-eigenvalue problem inside the neutronic solver is thus accelerated with the Anderson acceleration. The numerical experimentations conducted in this work are performed using APOLLO3 and THEDI, and indicate that such coupling strategy improves the convergence rates in terms of number of iterations required and the total computational time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Inverse modeling of circular lattices via orbit response measurements in the presence of degeneracy

The number and location of beam position monitors (BPMs) and steerers with respect to the quadrupoles in a circular lattice can lead to degeneracy in the context of fitting linear optics and extracting lattice information from measured closed orbits. Furthermore, the measurement uncertainties due to the imperfection of BPMs and steerers can be propagated by the fitting process in ways that prohibit the successful extraction of discrepancies between lattice elements in the real machine and their description in the corresponding model. We systematically studied the influence of the placement of BPMs and steerers on the reconstruction of linear optics and corresponding lattice information. The derivative of orbit response coefficients with respect to the quadrupole strengths, the Jacobian, is derived as an analytical formula. This analytical version of the Jacobian is used to further derive the theoretical limitations of fitting linear optics from closed orbits in terms of the placement of BPMs and steerers. It is further demonstrated that when evaluating the Jacobian during the fitting procedure, the analytical version can be used in place of the conventional finite-difference computation. This allows for greatly improved efficiency when computing the Jacobian during each iteration of the fitting procedure. The approach is tested with large-scale simulations and the findings are verified by measurement data taken on SIS18 synchrotron at GSI Helmholtz Centre for Heavy Ion Research. The presented methods are of general nature and can be applied to other accelerator lattices as well. The fitting procedure by using the analytical Jacobian is tested in conjunction with various methods for mitigating quasidegeneracy and the results agree with those obtained by using the conventional Jacobian via finite-difference approximation.

47 OTHER INSTRUMENTATION↗

Full-waveform inversion in the time domain with an energy-weighted gradient

When applying full-waveform inversion to surface seismic reflection data, one difficulty is that the deep region of the model is usually not reconstructed as well as the shallow region. We develop an energy-weighted gradient method for the time-domain full-waveform inversion to accelerate the convergence rate and improve reconstruction of the entire model without increasing the computational cost. Three different methods can alleviate the problem of poor reconstruction in the deep region of the model: the layer stripping, depth-weighting and pseudo-Hessian schemes. The first two approaches need to subjectively choose stripping depths and weighting functions. The third one scales the gradient with only the forward propagation wavefields from sources. However, the Hessian depends on wavefields from both sources and receivers. Our new energy-weighted method makes use of the energies of both forward and backward propagated wavefields from sources and receivers as weights to compute the gradient. We compare the reconstruction of our new method with those of the conjugate gradient and pseudo-Hessian methods, and demonstrate that our new method significantly improves the reconstruction of both the shallow and deep regions of the model.

CONVERGENCE↗

Finding Beam Loss Locations at PIP2IT Accelerator With Oscillating Dipole Correctors

The PIP2IT accelerator was assembled in multiple stages in 2014 - 2021 to test concepts and components of the future PIP-II linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA H- beam to 16 MeV. To determine location of the beam loss in the accelerators low-energy part, where radiation monitors are ineffective, a method using oscillating trajectories was implemented. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync, produces a line at the corresponding frequency in spectra of BPM sum signals downstream of the loss point. Comparison of these responses along the beam line allows to find the loss location. The paper describes the method and results of its implementation at PIP2IT.

43 PARTICLE ACCELERATORS↗

Linear Accelerator-Based Radiosurgery Alone for Arteriovenous Malformation: More Than 12 Years of Observation

Purpose: Although radiosurgery is an accepted treatment method for intracranial arteriovenous malformations (AVMs), its long-term therapeutic effects have not been sufficiently evaluated, and many reports of long-term observations are from gamma-knife facilities. Furthermore, there are few reported results of treatment using only linear accelerator (LINAC)-based radiosurgery (LBRS). Methods and Materials: Over a period of more than 12 years, we followed the long-term results of LBRS treatment performed in 51 AVM patients. Results: The actuarial obliteration rates, after a single radiosurgery session, at 3, 5, 10, and 15 years were 46.9%, 54.0%, 64.4%, and 68.0%, respectively; when subsequent radiosurgeries were included, the rates were 46.9%, 61.3%, 74.2%, and 90.3%, respectively. Obliteration rates were significantly related to target volumes ≥4 cm{sup 3}, marginal doses ≥12 Gy, Spetzler-Martin grades (1 vs other), and AVM scores ≥1.5; multivariate analyses revealed a significant difference for target volumes ≥4 cm{sup 3}. The postprocedural actuarial symptomatic radiation injury rates, after a single radiation surgery session, at 5, 10, and 15 years were 12.3%, 16.8%, and 19.1%, respectively. Volumes ≥4 cm{sup 3}, location (lobular or other), AVM scores ≥1.5, and the number of radiosurgery were related to radiation injury incidence; multivariate analyses revealed significant differences associated with volumes ≥4 cm{sup 3} and location (lobular or other). Conclusions: Positive results can be obtained with LBRS when performed with a target volume ≤4 cm{sup 3}, an AVM score ≤1.5, and ≥12 Gy radiation. Bleeding and radiation injuries may appear even 10 years after treatment, necessitating long-term observation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗