Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

The Time of Flight Upgrade for CLAS at 12 GeV

The Time of Flight (TOF) system is a detection system within the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson National Accelerator Facility. CLAS, being a magnetic toroidal multi-gap spectrometer, is used in the detection of particles and their varying properties. Jefferson National Accelerator Facility is providing an incoming electron beam of energy 6 GeV that is used to probe the structure and production of these particles. The CLAS detector is currently adapted to energies of up to 6 GeV, but with recent approval it will now upgrade to energies of 12 GeV. CLAS consists of drift chambers to determine the charged particle paths, gas Cherenkov counters for electron discrimination, TOF scintillators for particle identification, and an electromagnetic calorimeter for identifying showering electrons and photons. The TOF system, which is our focus, is composed of scintillation counters at the forward angle, and covers an area of 206 meters squared. Therefore, we look to upgrade and construct the TOF system of CLAS and outline strategies of current construction, purpose for design, and outlook for the TOF system upgrade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Free electron lasers driven by plasma accelerators: status and near-term prospects

Owing to their ultra-high accelerating gradients, combined with injection inside micrometer-scale accelerating wakefield buckets, plasma-based accelerators hold great potential to drive a new generation of free-electron lasers (FELs). Indeed, the first demonstration of plasma-driven FEL gain was reported recently, representing a major milestone for the field. Several groups around the world are pursuing these novel light sources, with methodology varying in the use of wakefield driver (laser-driven or beam-driven), plasma structure, phase-space manipulation, beamline design, and undulator technology, among others. This paper presents our best attempt to provide a comprehensive overview of the global community efforts towards plasma-based FEL research and development.

47 OTHER INSTRUMENTATION↗

Roofline model toolkit: A practical tool for architectural and program analysis

We present preliminary results of the Roofline Toolkit for multicore, many core, and accelerated architectures. This paper focuses on the processor architecture characterization engine, a collection of portable instrumented micro benchmarks implemented with Message Passing Interface (MPI), and OpenMP used to express thread-level parallelism. These benchmarks are specialized to quantify the behavior of different architectural features. Compared to previous work on performance characterization, these microbenchmarks focus on capturing the performance of each level of the memory hierarchy, along with thread-level parallelism, instruction-level parallelism and explicit SIMD parallelism, measured in the context of the compilers and run-time environments. We also measure sustained PCIe throughput with four GPU memory managed mechanisms. By combining results from the architecture characterization with the Roofline model based solely on architectural specifications, this work offers insights for performance prediction of current and future architectures and their software systems. To that end, we instrument three applications and plot their resultant performance on the corresponding Roofline model when run on a Blue Gene/Q architecture.

97 MATHEMATICS AND COMPUTING↗

Advanced light source-Upgrade accumulator-ring gas bremsstrahlung production

Lawrence Berkeley National Laboratory is designing a new electron synchrotron for scientific research using synchrotron radiation. An upgrade of the Advanced Light Source (ALS) would position the nation to retain its international competitiveness in the soft X-ray sciences. The ALS is a 1.9 GeV storage ring operating at 500 mA of beam current. It is optimized to produce intense beams of soft X-rays, which offer spectroscopic contrast, nanometer-scale resolution, and broad temporal sensitivity. Upgrading the ALS storage ring from a triple-bend-achromat to a multibend-achromat (MBA) lattice design will provide a soft X-ray source that is up to 100–1,000 times brighter than today’s ALS and will provide a significantly higher fraction of coherent light in the soft X-ray region than is currently available at the ALS. Further, the upgraded ALS will offer the highest coherent flux of any existing or planned storage-ring facility, worldwide, up to a photon energy of 3.5 keV. The addition of an accumulator ring that enables on-axis, swap-out, recovery, and exchange of bunch trains is required to achieve this coherence and brightness. Analysis of the radiation generated and shielding required by the addition of this new accelerator is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-Nuclei identification with PAMELA space telescope: preliminary in-flight results

The observational objectives of the PAMELA space telescope, launched the 15th of June 2006, are to measure the spectra of antiprotons, positrons and nuclei in a wide range of energies, to search for primordial antimatter as well as the determination of light nuclei fluxes from hydrogen to oxygen in a wide energy range and with very high statistics. Data gathered with the PAMELA instrument will deal with a wide range of fundamental issues like the understanding of the acceleration, propagation and trapping mechanism of cosmic rays in our Galaxy. In this paper preliminary results on the charge discrimination capabilities of PAMELA for light nuclei will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The GlueX Detector

The GlueX detector is being built along with the new experimental Hall D at Jefferson lab as part of the 12 GeV upgrade project which received CD-3 approval in fall 2008. GlueX is a fixed target experiment built around a 2 Tesla superconducting solenoid having charged particle tracking and calorimetry with large acceptance. A high rate DAQ system consisting of pipeline electronics will allow the detector to operate at high luminosity (10{sup 8} tagged {lambda}/sec on target). Details on the photon beam and GlueX detector are given including capabilities in resolutions and rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The materials science X-ray beamline BL8 at the DELTA storage ring

The instrumentation of the hard X-ray beamline BL8 at the 1.5 GeV Dortmund Electron Accelerator DELTA is described, and the properties of the X-ray optical elements are presented together with experimental data of different fields of research. The beamline, which makes use of the photons emitted by a superconducting asymmetric wiggler, is dedicated to X-ray studies--especially X-ray absorption spectroscopy (XAS)--in the spectral range from about 1 keV to ca. 25 keV photon energy using three different monochromators, namely YB{sub 66}(400), Si(111) and Si(311). The endstation comprises a 6-axis diffractometer that is capable of carrying heavy loads related to non-ambient sample environments such as high pressure cells, cryostats or even complete ultrahigh vacuum systems. X-ray absorption spectra from several reference compounds illustrate the performance of the beamline optics concerning e.g. energy range, energy resolution and beam stability. Fluorescence detection enables the investigation of dilute sample systems, and surface sensitive reflection mode experiments are possible for thin film studies.

36 MATERIALS SCIENCE↗

Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

07 ISOTOPE AND RADIATION SOURCES↗

A new compact, high sensitivity neutron imaging system

We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of neutron capture cross section of Li-7 at J-PARC / MLF / ANNRI

We have measured the {sup 7}Li(n,γ){sup 8}Li reaction at Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) installed at the Material and Life science experimental Facility in the Japan Proton Accelerator Research Complex (J-PARC / MLF). In this experiment, we used intense pulsed neutron beam provided by J-PARC / MLF and high performance Ge spectrometer, which is one of the main detectors of the ANNRI. We clearly detected γ rays from the {sup 7}Li(n,γ){sup 8}Li reaction with sufficient signal-to-noise ratio.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Illuminating seafloor faults and ocean dynamics with dark fiber distributed acoustic sensing

Distributed fiber-optic sensing technology coupled to existing subsea cables (dark fiber) allows observation of ocean and solid earth phenomena. We used an optical fiber from the cable supporting the Monterey Accelerated Research System during a 4-day maintenance period with a distributed acoustic sensing (DAS) instrument operating onshore, creating a ~10,000-component, 20-kilometer-long seismic array. Recordings of a minor earthquake wavefield identified multiple submarine fault zones. Ambient noise was dominated by shoaling ocean surface waves but also contained observations of in situ secondary microseism generation, post–low-tide bores, storm-induced sediment transport, infragravity waves, and breaking internal waves. DAS amplitudes in the microseism band tracked sea-state dynamics during a storm cycle in the northern Pacific. These observations highlight this method’s potential for marine geophysics.

Lindsey, Nathaniel J.↗

Individual NSLS-II Multipole Magnet Alignment by Laser Trackers

The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.

36 MATERIALS SCIENCE↗

Workflows Community Summit 2022: A Roadmap Revolution

Scientific workflows have become integral tools in broad scientific computing use cases. Science discovery is increasingly dependent on workflows to orchestrate large and complex scientific experiments that range from the execution of a cloud-based data preprocessing pipeline to multi-facility instrument-to-edge-to-HPC computational workflows. Given the changing landscape of scientific computing (often referred to as a computing continuum) and the evolving needs of emerging scientific applications, it is paramount that the development of novel scientific workflows and system functionalities seek to increase the efficiency, resilience, and pervasiveness of existing systems and applications. Specifically, the proliferation of machine learning/artificial intelligence (ML/AI) workflows, need for processing large-scale datasets produced by instruments at the edge, intensification of near real-time data processing, support for long-term experiment campaigns, and emergence of quantum computing as an adjunct to HPC, have significantly changed the functional and operational requirements of workflow systems. Workflow systems now need to, for example, support data streams from the edge-to-cloud-to-HPC, enable the management of many small-sized files, allow data reduction while ensuring high accuracy, orchestrate distributed services (workflows, instruments, data movement, provenance, publication, etc.) across computing and user facilities, among others. Further, to accelerate science, it is also necessary that these systems implement specifications/standards and APIs for seamless (horizontal and vertical) integration between systems and applications, as well as enable the publication of workflows and their associated products according to the FAIR principles.

97 MATHEMATICS AND COMPUTING↗

Renewable Energy and Efficiency Technologies in Scenarios of U.S. Decarbonization in Two Types of Models: Comparison of GCAM Modeling and Sector-Specific Modeling

Energy system projections from analytic models inform actions ranging from short-term and local decisions, such as technology and infrastructure deployment, to global and long-term negotiations and targets. Computational limits require the designers of these models to trade off between coverage and resolution. Some models, such as the Global Change Analysis Model (GCAM), represent all energy sources and uses but at a relatively coarse level of resolution. GCAM balances global supply and demand of all energy carriers by endogenously projecting prices for energy sources and costs of greenhouse gas mitigation while capturing interlinkages between the energy system, water, agriculture and land use, the economy, and the climate. This global model was used to frame the Long-Term Strategy released by the White House in 2021 and has been used to inform national and global economy-wide decarbonization discussions and strategy development for decades. Other models instead focus on a portion of the energy sector with greater detail and resolution. The Regional Energy Deployment System (ReEDS) electricity-sector model, for example, projects capacity expansion with an emphasis on integration of variable renewable energy into the grid of the future. The Transportation Energy and Mobility Pathway Options (TEMPO) transportation-sector model enables analysis of household choices in adoption, charging, and use of electric vehicles. The Scout buildings-sector model supports detailed consideration of the policies and markets that can accelerate the adoption of energy conservation measures in buildings. Such sector-specific models are instrumental in informing technology research, sectoral planning strategies, and sector-specific aspects of greenhouse gas (GHG) mitigation strategies in the United States. These global and sector-specific modeling approaches can complement each other. The global approach ensures consistent, endogenous energy pricing and resource allocation, which can substantially diverge from current conditions in transformative scenarios, while the sector-specific approach facilitates representation of granular details across spatial, temporal, technological, and market dimensions that enable exploration of particular interactions and trade-offs. This report presents the results of recent work to explore the differences and tradeoffs between these approaches by comparing GCAM with the sector-specific ReEDS, TEMPO, and Scout models. The report compares both model structures and results, and discusses their potential relevance and applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overview of recent trends and developments for BPM systems

Beam position monitoring (BPM) systems are the workhorse of beam diagnostics for almost any kind of charged particle accelerator: linear, circular or transport-lines, operating with leptons, hadrons or heavy ions. BPMs are essential for beam commissioning, accelerator fault analysis and trouble shooting, machine optics, as well as lattice measurements, and finally, for accelerator optimization, in order to achieve the ultimate beam quality. This presentation summarizes the efforts of the beam instrumentation community on recent developments and advances on BPM technologies, i.e. BPM pickup monitors and front-end electronics (analog and digital). Principles, examples, and state-of-the-art status on various BPM techniques, serving hadron and heavy ion machines, sync light synchrotron's, as well as electron linacs for FEL or HEP applications are outlined.

43 PARTICLE ACCELERATORS↗

Compact in situ probe for magnetotransport measurements of 2D materials under variable tensile strain

The recent development of freestanding oxide membranes has opened new opportunities for strain engineering of transition metal oxides beyond values accessible in bulk samples. While a number of studies have been performed with fixed strain, the ability to dynamically control the strain state during measurement would be greatly enabling. To this end, we present an in situ uniaxial strain probe optimized for transport measurements of tensile-strained 2D or quasi-2D materials down to 2 K. Utilizing a flexible polyimide substrate as the stress transfer medium, our platform simplifies the sample preparation process and allows precise alignment of strain fields relative to the crystalline axes. An in situ optical microscope monitors the macroscopic strain state operando and makes it possible to complete an entire magnetotransport study at cryogenic temperatures under continuous strain variations. We demonstrate the capabilities of the probe on a freestanding LaNiO 3 membrane, where we induce tensile strain up to 8% and observe a corresponding strong transport anisotropy. In view of the rapid developments in low-dimensional materials synthesis and the plethora of novel quantum phenomena they exhibit, this strain probe provides general instrumentation for examining and controlling these properties via strain.

2D materials↗

Operational Radiation Protection in High-Energy Physics Accelerators

An overview of operational radiation protection (RP) policies and practices at high-energy electron and proton accelerators used for physics research is presented. The different radiation fields and hazards typical of these facilities are described, as well as access control and radiation control systems. The implementation of an operational RP programme is illustrated, covering area and personnel classification and monitoring, radiation surveys, radiological environmental protection, management of induced radioactivity, radiological work planning and control, management of radioactive materials and wastes, facility dismantling and decommissioning, instrumentation and training.

43 PARTICLE ACCELERATORS↗