Search NASA⌕ Search

SEARCH · Search NASA

Results for “Basic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

SU-F-T-463: Light-Field Based Dynalog Verification

Purpose: To independently verify leaf positions in so-called dynalog files for a Varian iX linac with a Millennium 120 MLC. This verification provides a measure of confidence that the files can be used directly as part of a more extensive intensity modulated radiation therapy / volumetric modulated arc therapy QA program. Methods: Initial testing used white paper placed at the collimator plane and a standard hand-held digital camera to image the light and shadow of a static MLC field through the paper. Known markings on the paper allow for image calibration. Noise reduction was attempted with removal of ‘inherent noise’ from an open-field light image through the paper, but the method was found to be inconsequential. This is likely because the environment could not be controlled to the precision required for the sort of reproducible characterization of the quantum noise needed in order to meaningfully characterize and account for it. A multi-scale iterative edge detection algorithm was used for localizing the leaf ends. These were compared with the planned locations from the treatment console. Results: With a very basic setup, the image of the central bank A leaves 15–45, which are arguably the most important for beam modulation, differed from the planned location by [0.38±0.28] mm. Similarly, for bank B leaves 15–45 had a difference of [0.42±0.28] mm Conclusion: It should be possible to determine leaf position accurately with not much more than a modern hand-held camera and some software. This means we can have a periodic and independent verification of the dynalog file information. This is indicated by the precision already achieved using a basic setup and analysis methodology. Currently, work is being done to reduce imaging and setup errors, which will bring the leaf position error down further, and allow meaningful analysis over the full range of leaves.

60 APPLIED LIFE SCIENCES↗

SU-F-T-479: Estimation of the Accuracy in Respiratory-Gated Radiotherapy

Purpose: Irregular respiratory patterns affects dose outputs in respiratorygated radiotherapy and there is no commercially available quality assurance (QA) system for it. We designed and developed a patient specific QA system for respiratory-gated radiotherapy to estimate irradiated output. Methods: Our in-house QA system for gating was composed of a personal computer with the USB-FSIO electronic circuit connecting to the linear accelerator (ONCOR-K, Toshiba Medical Systems). The linac implements a respiratory gating system (AZ-733V, Anzai Medical). During the beam was on, 4.2 V square-wave pulses were continually sent to the system. Our system can receive and count the pulses. At first, our system and an oscilloscope were compared to check the performance of our system. Next, basic estimation models were generated when ionization-chamber measurements were performed in gating using regular sinusoidal wave patterns (2.0, 2.5, 4.0, 8.0, 15 sec/cycle). During gated irradiation with the regular patterns, the number of the pulses per one gating window was measured using our system. Correlation between the number of the pulses per one gating and dose per the gating window were assessed to generate the estimation model. Finally, two irregular respiratory patterns were created and the accuracy of the estimation was evaluated. Results: Compared to the oscilloscope, our system worked similarly. The basic models were generated with the accuracy within 0.1%. The results of the gated irradiations with two irregular respiratory patterns show good agreement within 0.4% estimation accuracy. Conclusion: Our developed system shows good estimation for even irregular respiration patterns. The system would be a useful tool to verify the output for respiratory-gated radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-AB-207A-03: Image Quality, Dose, and Clinical Applications

Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: Understand the function and impact of major components of X-ray tube on the image quality. Understand the function and impact of major components of CT detector on the image quality. Be familiar with the basic procedure of CT image reconstruction. Understand the effect of image reconstruction on CT image quality and artifacts. Understand the root causes of common CT image artifacts. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. Be familiar with various CT dose metrics and their interaction with acquisition parameters. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.

60 APPLIED LIFE SCIENCES↗

TU-D-201-01: 2016 Economics Update

The purpose of this session is to introduce attendees to the healthcare reimbursement system and how it applies to the clinical work of a medical physicist. This will include general information about the different categories of payers and payees, how work is described by CPT codes, and how various payers set values for this work in different clinical settings. 2016 is another year of significant changes to the payment system. This presentation will describe the work encompassed in these codes and will give attendees an overview of the changes for 2016 as they apply to radiation oncology. Finally, some insight into what can be expected during 2017 will be presented. This includes what information is typically released by the Centers for Medicaid and Medicare Services (CMS) during the year and how we as an organization respond. This will include ways members can interact with the AAPM professional economics committee and other resources members may find helpful. Learning objectives1) Basics of how Medicare is structured and how reimbursement rates are set.2) Basic understanding of proposed changes to the 2016 Medicare rules.3) Describe economics and policy resources that are available from the AAPM and how to interact with the professional economics committee.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

TH-C-204-00: Medical Physics Workshop: An Update On the Journal’s Improvement Activities and Guidance On Writing and Reviewing Papers

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-01: Vision for Medical Physics and Status of Current Initiatives

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-02: Improving Manuscript Quality Via Structured Reviews, Enhanced Scientific Category Taxonomy, and Outreach

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-C-204-03: Writing Good Scientific Papers and Responding to Critiques

In this presentation, the Editors will outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. A major focus will be the transition to a new publisher in 2017 following a more than 40-year association with American Institute of Physics Publishing (AIPP). Vision for Medical Physics and status of current initiatives: Jeff Williamson, Editor-in-Chief The broad vision of Medical Physics is “to continue the Journal’s tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be the preeminent forum for exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; and (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities, we face are: electronic-only and open access publishing; competition from new radiological science journals; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. Recently implemented and ongoing initiatives include: Revised Table of Contents (TOC) and more contemporary topical submission categories Structured review template in HTML format Comprehensive hierarchical taxonomy for identifying reviewer expertise Formal process for soliciting high quality and impact Review and Vision 20/20 Articles We have recruited four Review Article Co-editors: John Rowlands and Ingrid Reiser (imaging physics) and Joao Seco and Tim Zhu (therapy physics). The Co-Editors will identify timely topics and solicit high profile authors to submit review manuscripts. To submit an article, authors will need to work with an assigned Co-Editor to develop a mutually acceptable outline and abstract. 5) A new and exciting class of articles: Medical Physics Dataset Articles (MPDAs) MPDAs describe scientifically or clinically valuable open-access datasets with high potential for contributing to the research of medical physicists working on related problems. In contrast to Research Articles, MPDAs should not include hypothesis testing; or data analyses supporting generalizable conclusions. The publically accessible dataset must be permanently archived before the MPDA can be published. This initiative is being led by Joe Deasy. Update on new publisher transition: The transition of AAPM scientific publishing operations to a major publishing house is a major opportunity to expand Medical Physics readership and its scholarly impact. The advantages include: (a) common manuscript management and web hosting platforms for Medical Physics and its sister journal, JACMP; (b) greater than 4-fold expansion of subscribing institutions; and (c) resources to mount data-driven, highly targeted marketing campaigns to enhance citation and download rates. A transition update of this epochal development, which has only begun as of this writing (3/31/16), will be given. Improving manuscript quality via structured reviews, enhanced scientific category taxonomy, and outreach: Shiva Das, Therapy Physics Editor Medical Physics is committed to continuous improvement with the ultimate goal of improving the potential impact of accepted manuscripts. In order to do so, Medical Physics must be able to tap into important/emerging areas and be able to select high quality contributions consistently via discerning reviews. Improving the quality of reviews is crucial to selecting high quality manuscripts and also to improving manuscript impact via feedback in the review process. With this in mind, Medical Physics is in the process of: (a) fostering outreach to important areas that are currently underrepresented in Medical Physics; (b) implementing a structured template review form; and (c) implementing a comprehensive scientific category taxonomy to identify reviewers who are best suited to an article. Outreach efforts have begun to various scientific areas. Strategies to increase submissions from these areas will be discussed. As a consequence of this effort, a special issue on particle therapy is under development. A review template was implemented in late 2014 on a limited test basis. Based on reviewer feedback, the template was restructured and shortened to capture essential review elements. The restructured template is due to be released shortly. The new scientific category taxonomy is in the process of being deployed to reviewers and associate editors. Salient aspects of the structured review template and scientific category taxonomy will be discussed in this talk. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections of manuscripts, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics manuscripts must include clear and concise statements of the novelty and clinical and/or scientific importance of the authors’ work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; and first demonstration that an existing engineering solution solves a clinical problem. Please note that we encourage authors of recently published conference proceedings (e.g., SPIE, IEEE) papers on novel medical physics related work to submit more substantial versions of that work to our journal. All submissions must include: sufficient background information and rationale; enough detail for others to reproduce the authors’ work; sufficient statistical analysis to refute or validate the authors’ hypotheses; a description of how the present work compares to, is distinct from, and improves upon others’ work; and sections devoted to the limitations of the study and future directions. Writing should be polished. Poor wording, grammar and composition frustrate the review process. Our journal does not have copyeditors for revising manuscripts. When authors receive critiques from the referees and associate editor, the authors should provide a detailed point-by-point response to each comment. The authors’ rebuttal should include the text of the original criticism, the authors’ response, and a pasted copy of the modified text along with the line numbers in the revised article. The new text should be highlighted in a different font color in the revised submission. Following these recommendations will improve submissions and facilitate the review process.

60 APPLIED LIFE SCIENCES↗

TH-F-202-02: Current Applications of MRI in Radiotherapy

MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MR physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai.

60 APPLIED LIFE SCIENCES↗

TH-F-202-03: Advances in MRI for Radiation Therapy

MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MR physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai.

60 APPLIED LIFE SCIENCES↗

TH-F-202-00: MRI for Radiation Therapy

MRI has excellent soft tissue contrast and can provide both anatomical and physiological information. It is becoming increasingly important in radiation therapy for treatment planning, image-guided radiation therapy, and treatment assessment. It is critically important at this time point to educate and update our medical physicists about MRI to prepare for the upcoming surge of MRI applications in radiation therapy. This session will review important basics of MR physics, pulse sequence designs, and current radiotherapy application, as well as showcase exciting new developments in MRI that can be potentially useful in radiation therapy. Learning Objectives: To learn basics of MR physics and understand the differences between various pulse sequences To review current applications of MRI in radiation therapy.To discuss recent MRI advances for future MRI guided radiation therapy Partly supported by NIH (1R21CA165384).; W. Miller, Research supported in part by Siemens Healthcare; G. Li, My clinical research is in part supported by NIH U54CA137788. I have a collaborative research project with Philips Healthcare.; J. Cai, jing cai.

60 APPLIED LIFE SCIENCES↗

Supersaturated calcium carbonate solutions are classical

We will present a description of nucleation phenomena in the condensed phase that takes into account non-ideal solution effects associated with cluster-cluster interaction. To do this we employ aggregation-volume bias Monte Carlo simulation, making the estimation of free-energy of large pre-critical clusters of sizes 10-20 tractable. We will compare and contrast empirical potential and electronic structure (e.g. Density functional theory) based descriptions of molecular interaction associated with the nucleation of CaCO 3 , highlighting free-energy trends and qualitative differences in populations of pre-critical clusters as a function of supersaturation. The influence of how the precise local interaction influences the non-ideal solution behavior on the nucleation and growth processes will be highlighted. This research was supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences.

Henzler, Katja (ORCID:0000000335905005)↗

Lactose-Inducible System for Metabolic Engineering of Clostridium ljungdahlii

The development of tools for genetic manipulation of Clostridium ljungdahlii has increased its attractiveness as a chassis for autotrophic production of organic commodities and biofuels from syngas and microbial electrosynthesis and established it as a model organism for the study of the basic physiology of acetogenesis. In an attempt to expand the genetic toolbox for C. ljungdahlii, the possibility of adapting a lactose-inducible system for gene expression, previously reported for Clostridium perfringens, was investigated. The plasmid pAH2, originally developed for C. perfringens with a gusA reporter gene, functioned as an effective lactose-inducible system in C. ljungdahlii. Lactose induction of C. ljungdahlii containing pB1, in which the gene for the aldehyde/alcohol dehydrogenase AdhE1 was downstream of the lactose-inducible promoter, increased expression of adhE1 30-fold over the wild-type level, increasing ethanol production 1.5-fold, with a corresponding decrease in acetate production. Lactose-inducible expression of adhE1 in a strain in which adhE1 and the adhE1 homolog adhE2 had been deleted from the chromosome restored ethanol production to levels comparable to those in the wild-type strain. Inducing expression of adhE2 similarly failed to restore ethanol production, suggesting that adhE1 is the homolog responsible for ethanol production. Lactose-inducible expression of the four heterologous genes necessary to convert acetyl coenzyme A (acetyl-CoA) to acetone diverted ca. 60% of carbon flow to acetone production during growth on fructose, and 25% of carbon flow went to acetone when carbon monoxide was the electron donor. These studies demonstrate that the lactose-inducible system described here will be useful for redirecting carbon and electron flow for the biosynthesis of products more valuable than acetate. Furthermore, this tool should aid in optimizing microbial electrosynthesis and for basic studies on the physiology of acetogenesis.

Banerjee, A↗

Structural Basis of a Thiol-Disulfide Oxidoreductase in the Hedgehog-Forming Actinobacterium Corynebacterium matruchotii

ABSTRACT The actinobacterium Corynebacterium matruchotii has been implicated in nucleation of oral microbial consortia leading to biofilm formation. Due to the lack of genetic tools, little is known about basic cellular processes, including protein secretion and folding, in this organism. We report here a survey of the C. matruchotii genome, which encodes a large number of exported proteins containing paired cysteine residues, and identified an oxidoreductase that is highly homologous to the Corynebacterium diphtheriae thiol-disulfide oxidoreductase MdbA (MdbA Cd ). Crystallization studies uncovered that the 1.2-Å resolution structure of C. matruchotii MdbA (MdbA Cm ) possesses two conserved features found in actinobacterial MdbA enzymes, a thioredoxin-like fold and an extended α-helical domain. By reconstituting the disulfide bond-forming machine in vitro , we demonstrated that MdbA Cm catalyzes disulfide bond formation within the actinobacterial pilin FimA. A new gene deletion method supported that mdbA is essential in C. matruchotii . Remarkably, heterologous expression of MdbA Cm in the C. diphtheriae Δ mdbA mutant rescued its known defects in cell growth and morphology, toxin production, and pilus assembly, and this thiol-disulfide oxidoreductase activity required the catalytic motif CXXC. Altogether, the results suggest that MdbA Cm is a major thiol-disulfide oxidoreductase, which likely mediates posttranslocational protein folding in C. matruchotii by a mechanism that is conserved in Actinobacteria . IMPORTANCE The actinobacterium Corynebacterium matruchotii has been implicated in the development of oral biofilms or dental plaque; however, little is known about the basic cellular processes in this organism. We report here a high-resolution structure of a C. matruchotii oxidoreductase that is highly homologous to the Corynebacterium diphtheriae thiol-disulfide oxidoreductase MdbA. By biochemical analysis, we demonstrated that C. matruchotii MdbA catalyzes disulfide bond formation in vitro . Furthermore, a new gene deletion method revealed that deletion of mdbA is lethal in C. matruchotii . Remarkably, C. matruchotii MdbA can replace C. diphtheriae MdbA to maintain normal cell growth and morphology, toxin production, and pilus assembly. Overall, our studies support the hypothesis that C. matruchotii utilizes MdbA as a major oxidoreductase to catalyze oxidative protein folding.

Luong, Truc Thanh↗