Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Mode Damping Measurement for the APS Deflecting Cavity

The Advanced Photon Source has considered using a deflecting-cavity-based scheme to produce short pulse xrays. A deflecting cavity design has been completed. To verify the simulation result on this cavity, a copper prototype of the design has been fabricated for bench measurement. In this paper, we report our measurement results on this cavity. All the cavity modes below 5 GHz were identified by comparing the field distributions with calculations along different beam paths. After adding the damper, the measured Qexts of those modes were consistent with calculated values, which demonstrated that the cavity damping scheme was sufficient to reduce the wake impedances well below the safety thresholds.

Nassiri, A.↗

The Effect of Extending the Length of the Coupling Coils in a MuonIonization Cooling Channel

RF cavities are used to re-accelerate muons that have beencooled by absorbers that are in low beta regions of a muon ionizationcooling channel. A superconducting coupling magnet (or magnets) arearound or among the RF cavities of a muon ionization-cooling channel. Thefield from the magnet guides the muons so that they are kept within theiris of the RF cavities that are used to accelerate the muons. Thisreport compares the use of a single short coupling magnet with anextended coupling magnet that has one or more superconducting coils aspart of a muon-cooling channel of the same design as the muon ionizationcooling experiment (MICE). Whether the superconducting magnet is shortand thick or long and this affects the magnet stored energy and the peakfield in the winding. The magnetic field distribution also affects is themuon beam optics in the cooling cell of a muon coolingchannel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy and system size dependence of phi meson production in Cu+Cu and Au+Au collisions

We study the beam-energy and system-size dependence of {phi} meson production (using the hadronic decay mode {phi} {yields} K{sup +}K{sup -}) by comparing the new results from Cu + Cu collisions and previously reported Au + Au collisions at {radical}s{sub NN} = 62.4 and 200 GeV measured in the STAR experiment at RHIC. Data presented are from midrapidity (|y| < 0.5) for 0.4 < p{sub T} < 5 GeV/c. At a given beam energy, the transverse momentum distributions for {phi} mesons are observed to be similar in yield and shape for Cu + Cu and Au + Au colliding systems with similar average numbers of participating nucleons. The {phi} meson yields in nucleus-nucleus collisions, normalized by the average number of participating nucleons, are found to be enhanced relative to those from p + p collisions with a different trend compared to strange baryons. The enhancement for {phi} mesons is observed to be higher at {radical}s{sub NN} = 200 GeV compared to 62.4 GeV. These observations for the produced {phi}(s{bar s}) mesons clearly suggest that, at these collision energies, the source of enhancement of strange hadrons is related to the formation of a dense partonic medium in high energy nucleus-nucleus collisions and cannot be alone due to canonical suppression of their production in smaller systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Laser-accelerated Ion Beams for a Collimated Neutron Source

High-flux neutrons for imaging and materials analysis applications have typically been provided by accelerator- and reactor-based neutron sources. A novel approach is to use ultraintense (>1018W/cm2) lasers to generate picosecond, collimated neutrons from a dual target configuration. In this article, the production capabilities of present and upcoming laser facilities are estimated while independently maximizing neutron yields and minimizing beam divergence. A Monte-Carlo code calculates angular and energy distributions of neutrons generated by D-D fusion events occurring within a deuterated target for a given incident beam of D+ ions. Tailoring of the incident distribution via laser parameters and microlens focusing modifies the emerging neutrons. Projected neutron yields and distributions are compared to conventional sources, yielding comparable on-target fluxes per discharge, shorter time resolution, larger neutron energies and greater collimation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle

Purpose: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. Methods: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. Results: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. Conclusions: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.

60 APPLIED LIFE SCIENCES↗

Ring formation in self-focusing of electromagnetic beams in plasmas

This article presents a paraxial theory of ring formation as an initially Gaussian beam propagates in a nonlinear plasma, characterized by significant collisional or ponderomotive nonlinearity. Regions in the axial irradiance-(beam width){sup -2} space, for which the ring formation occurs and the paraxial theory is valid, have been characterized; for typical points in these regions the dependence of the beam width parameter and the radial distribution of irradiance on the distance has been specifically investigated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning and benchmarking a 3D dosimetry system for clinical use

Purpose: A 3D dosimetry system is described which consists of two parts: a radiochromic plastic dosimeter PRESAGE (which responds to absorbed dose with a linear change in optical-density) and the Duke large-field-of-view optical-CT scanner (DLOS). The DLOS/PRESAGE system has recently been commissioned and benchmarked for clinical use and, in particular, for verification and commissioning of complex radiation treatments. Methods: DLOS commissioning involved determining the dynamic range, spatial resolution, noise, temporal, and other characteristics of the light source and imaging components. Benchmarking tests were performed on the combined DLOS/PRESAGE system to establish baseline dosimetric performance. The tests consisted of delivering simple radiation treatments to PRESAGE dosimeters, and comparing the measured 3D relative dose distributions with the known gold standard. The gold standard distribution was obtained from machine beam-data or the treatment planning system (TPS). All studies used standardized procedures to ensure consistency. Results: For commissioning, isotropic spatial resolution was submillimeter (MTF > 0.5 for frequencies of 1.5 lp/mm) and the dynamic range was {approx}60 dB. Flood field uniformity was within 10% and stable after 45 min of warm-up. Stray-light is small, due to telecentricity, but even the residual can be removed through deconvolution by a point-spread-function. For benchmarking, the mean 3D passing NDD (normalized dose distribution) rate (3%, 3mm, 5% dose threshold) over the benchmark data sets was 97.3% {+-} 0.6% (range 96%-98%), which is on par with other planar dosimeters used in external beam radiation therapy indicating excellent agreement. Noise was low at <2% of maximum dose (4-12 Gy) for 2 mm reconstructions. The telecentric design was critical to enabling fast imaging with minimal stray-light artifacts. Conclusions: This work presents the first comprehensive benchmarking of a 3D dosimetry system for clinical use. The DLOS/PRESAGE benchmark tests show consistently good agreement to simple known distributions. The system produces accurate isotropic 2 mm dose data over clinical volumes (e.g., 16 cm diameter phantoms, 12 cm height), in under 15 min. It represents a uniquely useful and versatile new tool for commissioning and verification of complex therapy treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relation between the diffraction pattern visibility and dispersion of particle sizes in an ektacytometer

We have calculated the angular distribution of the light intensity in the diffraction pattern arising upon scattering of a laser beam on a suspension of red blood cells in an ektacytometer. We have estimated the diffraction pattern visibility in the region of the first diffraction minimum and the first diffraction maximum as a function of particle size variation. It is shown that in this fragment of the diffraction pattern its visibility decreases already twofold in the case of a standard deviation of the particle size from the average value, equal to 8%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stable harmonic multiplying gyrotron traveling-wave amplifier with distributed wall losses and attenuating severs

Harmonic multiplying gyrotron traveling-wave amplifiers (gyro-TWTs) provide magnetic field reduction and frequency multiplication. However, spurious oscillations may reduce the amplification of the gyro-TWT. Most distributed-loss structures are stabilized in gyro-TWTs that operate at low beam currents. Attenuating severs are added to the interaction circuit of a distributed-loss gyro-TWT to prevent high beam currents that result in mode competition. This study proposes a Ka-band harmonic multiplying gyro-TWT, using distributed wall losses and attenuating severs, to improve the stability of the amplification and the performance of the amplifier. Simulation results reveal that the absolute instabilities are effectively suppressed by wall losses of the lossy and severed sections, especially in the low-k{sub z} and high-order modes. Meanwhile, the severed section, dividing an interaction circuit into several short sections, reduces the effective interaction lengths of the absolute instabilities. The stable harmonic multiplying gyro-TWT is predicted to yield a peak output power of 230 kW at 33.65 GHz with an efficiency of 30%, a saturated gain of 40 dB, and a 3 dB bandwidth of 0.8 GHz for a 60 kV, 13 A electron beam with an axial velocity spread of {delta}v{sub z}/v{sub z}=8%. The power/gain scaling and phase relation between the drive and the output waves are elucidated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear stability of solar type 3 radio bursts. 1: Theory

A theory of the excitation of solar type 3 bursts is presented. Electrons initially unstable to the linear bump-in-tail instability are shown to rapidly amplify Langmuir waves to energy densities characteristic of strong turbulence. The three-dimensional equations which describe the strong coupling (wave-wave) interactions are derived. For parameters characteristic of the interplanetary medium the equations reduce to one dimension. In this case, the oscillating two stream instability (OTSI) is the dominant nonlinear instability, and is stablized through the production of nonlinear ion density fluctuations that efficiently scatter Langmuir waves out of resonance with the electron beam. An analytical model of the electron distribution function is also developed which is used to estimate the total energy losses suffered by the electron beam as it propagates from the solar corona to 1 A.U. and beyond.

Smith, R. A.↗

Nonlinear stability of solar type III radio bursts. I - Theory

A theory of the excitation of solar type III bursts is presented. Electrons initially unstable to the linear bump-in-tail instability are shown to rapidly amplify Langmuir waves to energy densities characteristic of strong turbulence. The three-dimensional equations which describe the strong coupling (wave-wave) interactions are derived. For parameters characteristic of the interplanetary medium the equations reduce to one-dimension. In that case the oscillating two-stream instability (OTSI) is the dominant nonlinear instability. OTSI is stabilized through the production of nonlinear ion density fluctuations that efficiently scatter Langmuir waves out of resonance with the electron beam. An analytical model of the electron distribution function is also developed which is used to estimate the total energy losses suffered by the electron beam as it propagates from the solar corona to 1 AU and beyond.

Smith, R. A.↗

Bunch Length and Impedance Measurements at SPEAR3

Streak camera measurements were made at SPEAR3 to characterize longitudinal coupling impedance. For the nominal optics, data was taken at three rf voltages and a single-bunch current range of 0-20mA. Both bunchcentroid phase shift and bunch lengthening were recorded to extract values for resistive and reactive impedance. An (R+L) and a Q=1 model were then back-substituted into the Haissinski equation and compared with raw profile data. In the short bunch (low-{alpha}) mode, distribution 'bursting' was observed.

43 PARTICLE ACCELERATORS↗

Inter-ion coulomb interactions in a magneto-optical trap ion source

We have investigated the role played by inter-ion Coulomb interactions in a magneto-optical trap ion source (MOTIS). Using a Monte Carlo simulation accounting for all pair-wise ion-ion Coulomb interactions in the source, we have calculated the broadening of the transverse spatial and velocity distributions as well as the increase in emittance over a range of beam currents and extraction electric fields. Using a {sup 7}Li MOTIS, we have experimentally studied the broadening of the spatial distribution as a function of total beam current and extraction electric field by measuring the fraction of the beam current that passes through a 20 {mu}m diameter aperture. The Monte Carlo simulations agree well with the experimental results, indicating that such simulations capture the essential physics of the source. Our results show that while Coulomb interactions can cause a significant increase in emittance in some situations, it is possible to keep the effects to an acceptable level by suitable choice of extraction field and beam current. These considerations are essential to the process of optimizing MOTIS geometry and operating conditions for use in high-resolution focused ion beam applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation and theory for two-dimensional beam-plasma instability

A comparative study of the dynamics of the electron beam-plasma system in two spatial dimensions is carried out by means of particle-in-cell (PIC) simulation and quasilinear theory. In the literature, the beam-plasma instability is usually studied with one-dimensional assumption. Among the few works that include higher-dimensional effects are two- and three-dimensional quasilinear theory and two-dimensional PIC simulations. However, no efforts were made to compare the theory and simulation side by side. The present paper carries out a detailed comparative study of two-dimensional simulation and quasilinear theory. It is found that the quasilinear theory quite adequately accounts for most important features associated with the simulation result. For instance, the particle diffusion time scale, the maximum wave intensity, dynamical development of the electron distribution function, and the change in the wave spectrum all agree quantitatively. However, certain nonlinear effects such as the Langmuir condensation phenomenon are not reproduced by the quasilinear theory. Nevertheless, the present paper verifies that the simple quasilinear theory is quite effective for the study of beam-plasma instability for the present choice of parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of E1 and E2 cross sections of {sup 12}C({alpha},{gamma}){sup 16}O using pulsed {alpha} beams

We have measured the {gamma}-ray angular distribution of the {sup 12}C({alpha},{gamma}){sup 16}O reaction at a center-of-mass energy of E{sub cm} 1.6 MeV and E{sub cm} = 1.4 MeV. In this experiment, we used high efficiency anti-Compton NaI(Tl) spectrometers to detect a {gamma}-ray from the reaction with a large S/N ratio, intense pulsed {alpha} beams to discriminate true events from neutron induced background by using a time-of-flight (TOF) method, and the monitoring system of target thickness. We could pick up true events from the reaction free from intense neutron background with high statistics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Studies of Ions Emission in a Small Plasma Focus Device of Hundreds of Joules

Ion beam emission in plasma focus (PF) discharges was originally investigated to explain the strong forward anisotropy observed in the neutron. Several properties of PF emitted deuteron beams have been measured, including their angular distributions and energy spectra in devices operating with energies from 1 kJ to 1 MJ. At present there is a growing interest in the development of very small PF devices operating under 1 kJ. As part of the characterization program of the very low energy PF devices (<1 kJ) developed at the Chilean Nuclear Energy Commission, the charges particle emission in hydrogen (H{sub 2}) and mixture (H{sub 2}+%Ar) are being studied. In order to obtain an estimation of the ions energy spectrum and ionization grade, by using time of flight method, a graphite collector system operating in the bias ion collector mode was constructed and it is being used. Preliminary results of the ion beams measurements in different experimental conditions, at a plasma focus device of 400 joules (PF-400 J) are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-203: Investigation of 1.5T Magnetic Field Dose Effects On Organs of Different Density

Purpose: For the combined 1.5T/6MV MRI-linac system, the perpendicular magnetic field to the radiation beam results in altered radiation dose distributions. This Monte Carlo study investigates the change in dose at interfaces for common organs neighboring soft tissue. Methods: MCNP6 was used to simulate the effects of a 1.5T magnetic field when irradiating tissues with a 6 MV beam. The geometries used in this study were not necessarily anatomically representative in size in order to directly compare quantitative dose effects for each tissue at the same depths. For this purpose, a 512 cm{sup 3} cubic material was positioned at the center of a 2744 cm{sup 3} cubic soft tissue material phantom. The following tissue materials and their densities were used in this study: lung (0.296 g/cm{sup 3}), fat (0.95), spinal cord (1.038), soft tissue (1.04), muscle (1.05), eye (1.076), trabecular bone (1.40), and cortical bone (1.85). Results: The addition of a 1.5T magnetic field caused dose changes of +46.5%, +2.4%, −0.9%, −0.8%, −1.5%, −6.5%, and −8.8% at the entrance interface between soft tissue and lung, fat, spinal cord, muscle, eye, trabecular bone, and cortical bone tissues respectively. Dose changes of −39.4%, −4.1%, −0.8%, −0.8%, +0.5%, +6.7%, and +10.9% were observed at the second interface between the same tissues respectively and soft tissue. On average, the build-up distance was reduced by 0.6 cm, and a dose increase of 62.7% was observed at the exit interface between soft tissue and air of the entire phantom. Conclusion: The greatest changes in dose were observed at interfaces containing lung and bone tissues. Due to the prevalence and proximity of bony anatomy to soft tissues throughout the human body, these results encourage further examination of these tissues with anatomically representative geometries using multiple beam configurations for safe treatment using the MRI-linac system.

60 APPLIED LIFE SCIENCES↗

SU-E-T-213: Initial Experience with VMAT Plan and Delivery Verification Using a DICOM-RT Framework and Linac Delivery Log Files

Purpose: Mobius3D/MobiusFX (M3D/MFX), a commercial DICOM-RT based plan and delivery verification system, was used to compare calculated and delivered volumetric modulated arc therapy (VMAT) dose distributions using TrueBeam delivery log files (TrajectoryLogs). Methods: M3D/MFX utilizes measured linac commissioning data to generate institution specific beam models for evaluating planned and delivered dose distributions. 30 RapidArc prostate plans and 30 head and neck SmartArc plans were used in this study. For every plan, CT images, contoured structure sets, RT-plan, and RT-dose files were exported to M3D, which recalculated the patients’ planning CT dose distributions using a collapsed-cone-convolutionsuperposition algorithm. MFX utilized the acquired TrajectoryLogs to compute patients’ delivered dose distributions based on actual treatment delivery parameters. The agreement between computed and delivered dose distributions was evaluated utilizing a (3%, 3mm) global 3D-gamma analysis and dose-volume histogram changes for targets and organs at risk. Results: Excellent 3D-gamma agreements were observed for all VMAT plans. On average, for computed and delivered RapidArc and SmartArc plans the gamma passing rates were (99.0%±1.4%) and (96.8%±1.8%), respectively. The average difference for primary target prescription dose percent-coverage between calculated and delivered plans was (− 0.09%±2.52%) for RapidArc and (−2.71%±4.62%) for SmartArc cases. Similarly, the planning target mean dose differences were (1.38%±0.96%) for RapidArc and (1.17%±0.72%) for SmartArc plans. For the prostate plans, the calculated and delivered variations of the maximum dose for a 2cc volume for bladder and rectum were (1.32%±1.26%) and (0.65%±1.44%), respectively. The spinal-cord 2cc maximum dose differences of (3.26%±1.68%) were observed for the SmartArc plans. Conclusions: Clinical quality assurance practice based on linac treatment log files for verification of delivered 3D dose distributions in the patients’ geometries represents a paradigm shift from dose measurements in a phantom. This approach captures treatment planning beam modeling differences as well as the linac uncertainties during treatment delivery of the plan.

60 APPLIED LIFE SCIENCES↗