Alternative Auditing Approaches
This presentation for the 2017 Energy Exchange in Tampa, Florida, offers information about advanced auditing technologies and techniques including alternative auditing approaches and considerations and caveats.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This presentation for the 2017 Energy Exchange in Tampa, Florida, offers information about advanced auditing technologies and techniques including alternative auditing approaches and considerations and caveats.
Presentation describes how to build an energy-efficient data center on research facility campuses.
This poster for the 2019 Advanced Manufacturing Office Peer Review covers the high-performance computing model development for applications in Liquid Desiccant Air Conditioners. Conventional compressor-based cooling has undergone incremental changes over the past 100 years. Further improvements in efficiency require evermore complex systems, especially under humid conditions. Microporous membranes offer unique opportunities for efficient humidity control in buildings using an absorbent desiccant solution, but membranes are not designed for this purpose. This project used molecular dynamic (MD) simulations to determine the effect of membrane properties on important metrics for these air-conditioning applications, focusing on the membrane properties at the membrane/liquid/air interface. Improved membranes can enable smaller, more durable, and less costly designs for these membrane air conditioning systems.
This presentation summarizes the items discussed during the End-use Load Profiles for the U.S. Building Stock: Technical Advisory Group Meeting #3 on June 18, 2019.
This presentation summarizes the items discussed during the End-use Load Profiles for the U.S. Building Stock: Technical Advisory Group Meeting #2 on March 5, 2019.
Explore the source record for details and available documents.
This document summarizes the findings of a Pacific Northwest National Laboratory analysis on how whole-building energy data aggregation thresholds statistically affect customer privacy.
Advanced district thermal energy systems have the potential to achieve significant energy savings and facilitate the integration of renewable thermal resources and waste heat, contributing to reductions in carbon emissions. Such systems, also known as fifth generation district heating and cooling (5GDHC) systems, circulate water at temperatures close to ambient, and leverage electrically-driven water-source heat pumps located at connected buildings to further temper the water. However, barriers exist to the adoption of 5GDHC systems, including the factorial growth in potential network configurations as a function of the number of considered buildings. Topology optimization, which seeks to answer the questions, “Which is the best subset of buildings, if any, to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?” can accelerate the adoption of 5GDHC systems. This study is part of an effort to develop a topology optimization framework for district thermal energy systems. In this study, a heuristic for one aspect of the topology optimization problem---the use of the minimal spanning tree network to connect a given set of buildings at the least life cycle cost---is validated.
This fact sheet summarizes a plug load management system called ATLIS, or automatic type and location identification system. ATLIS was developed by the National Renewable Energy Laboratory and is being considered for commercial building applications.
PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.
Explore the source record for details and available documents.
Reactor containment performance is a critical defense-in- depth barrier for the prevention of radioactive release in the event of a nuclear accident. One of the functions of the containment is to assist in the decontamination of aerosolized radioactive particles through both 'passive' or natural processes and 'active' or mechanical processes. Current United States Nuclear Regulatory Commission (NRC) guidance (Reg. guide 1.183) allows the use of aerosol natural deposition correlations to quantify postaccident nuclear containment decontamination factors. Large Light Water Reactor (LLWR) correlations have previously been developed to quantify the contribution of natural phenomena to post-accident aerosol decontamination. Specific correlations must similarly be developed to support the safety analyses of Small Modular Reactors (SMRs). For LLWR plants, decontamination is achieved 'actively' by mechanical systems such as containment sprays and 'passively' via natural phenomena such as gravitational settling, condensation, impaction, thermophoresis, diffusiophoresis and hygroscopic effects. Integrated pressurized water reactor (iPWR) SMR designs do not have containment sprays; therefore, they rely primarily on passive natural phenomena for decontamination in the integrated reactor vessel. Analytical studies and inferences from LLWR test data suggest that the smaller containment vessel volume to surface area ratio, coupled with the thermal hydraulic properties of iPWR plants, would significantly enhance decontamination factors for these smaller designs. The research aims to quantify the amount of decontamination from natural phenomena for the range of iPWR physical and thermal hydraulic characteristics. A preliminary assessment has shown that diffusiophoresis, thermophoresis and hygroscopic effects are the major areas with a research gap for iPWR plants; hence these areas are the foci of the research. These first-of-a-kind experiments will be described and preliminary analytical results will be presented that show the expected effects of SMR-specific correlations on passive decontamination of aerosolized radionuclides.
The Energy Technology Innovation Partnership Project (ETIPP) worked with the University of Hawaii at Manoa to determine the technological and market feasibility of shallow geothermal heat exchanger technology for building cooling and energy efficiency applications.
California is a leader in automating demand response (DR) to promote low-cost, consistent, and predictable electric grid management tools. Over 250 commercial and industrial facilities in California participate in fully-automated programs providing over 60 MW of peak DR savings. This paper presents a summary of Open Automated DR (OpenADR) implementation by each of the investor-owned utilities in California. It provides a summary of participation, DR strategies and incentives. Commercial buildings can reduce peak demand from 5 to 15percent with an average of 13percent. Industrial facilities shed much higher loads. For buildings with multi-year savings we evaluate their load variability and shed variability. We provide a summary of control strategies deployed, along with costs to install automation. We report on how the electric DR control strategies perform over many years of events. We benchmark the peak demand of this sample of buildings against their past baselines to understand the differences in building performance over the years. This is done with peak demand intensities and load factors. The paper also describes the importance of these data in helping to understand possible techniques to reach net zero energy using peak day dynamic control capabilities in commercial buildings. We present an example in which the electric load shape changed as a result of a lighting retrofit.
The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a new construction test house in the mixed-humid climate zone of Silver Spring, MD in June 2011. The goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark through an optimized energy solutions package design that could be constructed on a production basis. This report outlines the features of this house, discusses the energy efficient design, and reports on short-term testing results.
The Philadelphia Housing Authority worked with the U.S. Department of Energy’s Building America Program to integrate energy-efficiency measures into the refurbishment process that each unit normally goes through between occupancies.
In moderate climates night ventilation is an effective and energy-efficient approach to improve the indoor thermal environment for office buildings during the summer months, especially for heavyweight construction. However, is night ventilation a suitable strategy for office buildings with lightweight construction located in cold climates? In order to answer this question, the whole energy-consumption analysis software EnergyPlus was used to simulate the indoor thermal environment and energy consumption in typical office buildings with night mechanical ventilation in three cities in northern China. The summer outdoor climate data was analyzed, and three typical design days were chosen. The most important factors influencing night ventilation performance such as ventilation rates, ventilation duration, building mass and climatic conditions were evaluated. When night ventilation operation time is closer to active cooling time, the efficiency of night ventilation is higher. With night ventilation rate of 10 ach, the mean radiant temperature of the indoor surface decreased by up to 3.9 C. The longer the duration of operation, the more efficient the night ventilation strategy becomes. The control strategies for three locations are given in the paper. Based on the optimized strategies, the operation consumption and fees are calculated. The results show that more energy is saved in office buildings cooled by a night ventilation system in northern China than ones that do not employ this strategy. (author)
Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.