Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

REopt: Energy Decision Analysis

The REopt techno-economic decision support platform is used by researchers to optimize energy systems for buildings, campuses, communities, microgrids, and more. REopt recommends the optimal mix of renewable energy, conventional generation, and energy storage technologies to meet cost savings, resilience, emissions reductions, and energy performance goals.

battery↗

Applicability study of Bayesian optimization in core neutronic design using a toy model

At the Japan Atomic Energy Agency (JAEA), an innovative design approach named ARKADIA (Advanced Reactor Knowledge- and AI-aided Design Integration Approach through the whole plant life cycle) for advanced nuclear reactors is currently under development. One task in ARKADIA is to build a system that automatically optimizes core and fuel designs by conducting core neutronic and thermal-hydraulic calculations, fuel integrity evaluations, and plant dynamic analyses. This system will be implemented to automatically find an optimal design that minimizes (or maximizes) objective function defined by core performance while varying the core and fuel design parameters such as fuel pin diameter, core height and diameter. In this study, as the first step of system development, we focused only on core neutronic design and conducted a study of automatic optimization. As the optimization algorithm, Bayesian optimization (BO), an effective method for optimization problems with expensive computational cost of objective function, was utilized. The applicability of BO was studied based on single- and two-objective optimization examples of core neutronic design in a toy model. As a result, in the former, it was shown that BO can give the optimal solution, which matches the reference solution calculated by a brute force calculation well, with a small number of required calculations. Usability on core neutronic designs, where the computational cost per case is high, was confirmed. In the latter, it was found that BO can give a Pareto solutions-set that shows good agreement with the reference solution. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gaining Real-Time Water Leak Detection

Devens Reserve Forces Training Area is a United States Army Reserve (USAR) Installation that struggles with severe water leaks, often causing significant damage to the facility and requiring major renovation. Traditional water use is highly dependent on occupancy, so it can be difficult to benchmark a facility’s water use. It can be exceptionally difficult when occupancy is transient and/or varies. Pacific Northwest National Laboratory (PNNL) collaborated with Devens to implement real-time monitoring of their water consumption by utilizing the smart meter data from their existing 23 water meters. PNNL created a simple algorithm to calculate hourly water consumption and trigger an alert to be instantly emailed to Devens’ personnel when there appears to be a water leak in any building with a smart water meter. Here, this approach is expected to save hundreds of thousands of dollars in unnecessary water consumption costs and damages from leaks and was implemented with little-to-no costs or service disruptions. Next steps for this project include slow leak detection through nighttime monitoring and to extrapolate this water leak approach to the remainder 360 water meters on USAR’s Enterprise Building Control System so USAR sites across the country can be instantly notified of potential water leaks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Electronics and Electric Machines for Advanced Aircraft

Power electronics and electric machines are critical components of efficient, high-performance aircraft - from fixed-wing turbine to electric vertical takeoff and landing aircraft and beyond. Improvements to these components create enormous energy efficiencies, enable cost savings, and ensure fail-safe operations. National Renewable Energy Laboratory researchers are developing innovative power electronics, electric motors, integrated electric traction drives, and thermal management systems to build highly efficient, lightweight, ultrareliable powertrains for aircraft.

42 ENGINEERING↗

ARC-100 Reactor Security-by-Design Summary 2025

This report applies the security-by-design methodology developed in a previous National Nuclear Security Administration–sponsored work to the ARC-100, a sodium-cooled fast reactor (SFR) being developed by ARC Clean Technology, Inc (ARC). The report contains no proprietary information specific to the ARC 100 reactor. The insights developed in this report are high-level, and generally applicable to other sodium fast reactor designs. The information presented here is the result of a qualitative safety-based analysis and would not inform any potential adversary beyond what would be found in a docketed safety analysis report. The scope of this present report covers ARC-100’s reactor core, used fuel storage, used fuel assembly wash station, cesium trap, sodium cold trap, noble gas decay tanks, used fuel dry storage facility, damaged fuel storage facility, and radioactive waste building. These systems are also compared to a generic SFR design assumed in the previous study. The security assessment results show changes in structures, systems, and components (SSCs) safety importance relative to the generic SFR SSCs. Several SSCs have higher importance rankings than others, and it is recommended that protection efforts are prioritized for these SSCs. Results from this work will furnish a technical justification for the feasibility of these solutions for the ARC reactor's design and, where applicable, identify any regulatory benefits conferred by the proactive design aspect within a risk management framework. This initiative will contribute to a more secure design of the ARC reactor and support its licensing process.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

PROMPT DOSE ANALYSIS FOR THE NATIONAL IGNITION FACILITY

Detailed 3-D modeling of the NIF facility is developed to accurately understand the prompt radiation environment within NIF. Prompt dose values are calculated for different phases of NIF operation. Results of the analysis were used to determine the final thicknesses of the Target Bay (TB) and secondary doors as well as the required shield thicknesses for all unused penetrations. Integrated dose values at different locations within the facility are needed to formulate the personnel access requirements within different parts of the facility. The conclusions of this presentation are: (1) The current NIF facility model includes all important features of the Target Chamber, shielding system, and building configuration; (2) All shielding requirements for Phase I operation are met; (3) Negligible dose values (a fraction of mrem) are expected in normally occupied areas during Phase I; (4) In preparation for the Ignition Campaign and Phase IV of operation, all primary and secondary shield doors will be installed; (5) Unused utility penetrations in the Target Bay and Switchyard walls ({approx}50%) will be shielded by 1 foot thick concrete to reduce prompt dose inside and outside the NIF facility; (6) During Phase IV, a 20 MJ shot will produce acceptable dose levels in the occupied areas as well as at the nearest site boundary; (7) A comprehensive radiation monitoring plan will be put in place to monitor dose values at large number of locations; and (8) Results of the dose monitoring will be used to modify personnel access requirements if needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrogen Production: Fundamentals and Case Study Summaries; Preprint

This paper presents a detailed description of the chemical and electrical processes for electrolysis and fuel cells, discusses important terminology, units of measure, constants, and chemical reactions, and suggests recommendations for calculating electrolyzer and fuel cell performance.

08 HYDROGEN↗

Assessing the Impact of Heat Rejection Technology on CSP Plant Revenue: Preprint

This paper explores the impact of cooling technology on revenue for hybrid-cooled plants with varying wet cooling penetration for four representative locations in the American Southwest. The impact of ACC design-point initial temperature difference (ITD - the difference between the condensing steam temperature and ambient dry-bulb) is also included in the analysis.

14 SOLAR ENERGY↗

Management of Knowledge Representation Standards Activities

Ever since the mid-seventies, researchers have recognized that capturing knowledge is the key to building large and powerful AI systems. In the years since, we have also found that representing knowledge is difficult and time consuming. In spite of the tools developed to help with knowledge acquisition, knowledge base construction remains one of the major costs in building an Al system: For almost every system we build, a new knowledge base must be constructed from scratch. As a result, most systems remain small to medium in size. Even if we build several systems within a general area, such as medicine or electronics diagnosis, significant portions of the domain must be represented for every system we create. The cost of this duplication of effort has been high and will become prohibitive as we attempt to build larger and larger systems. To overcome this barrier we must find ways of preserving existing knowledge bases and of sharing, re-using, and building on them. This report describes the efforts undertaken over the last two years to identify the issues underlying the current difficulties in sharing and reuse, and a community wide initiative to overcome them. First, we discuss four bottlenecks to sharing and reuse, present a vision of a future in which these bottlenecks have been ameliorated, and describe the efforts of the initiative's four working groups to address these bottlenecks. We then address the supporting technology and infrastructure that is critical to enabling the vision of the future. Finally, we consider topics of longer-range interest by reviewing some of the research issues raised by our vision.

Patil, Ramesh S.↗

PoE Lighting System Energy Reporting Study, Part 1

The replacement of today’s lighting infrastructure with LED products offers the potential for future connected lighting systems (CLS) that could become a data-collection platform that enables greater energy savings in buildings and cities. Such connected lighting systems can not only drastically improve the energy performance of lighting and other building systems, but also enable a wide array of services, benefits, and revenue streams that would enhance the value of lighting systems. As LED technology matures, maximizing the energy savings from connected LED lighting systems will become increasingly dependent on successful integration into the built environment. That’s why the DOE SSL Program is working closely with industry to identify and collaboratively address the technology development needs of CLS. For several years now, a growing number of wired and wireless network communication technologies have been integrated into commercially available lighting devices. While most commercially available lighting devices continue to require line-voltage AC power, a few new low-voltage DC technologies have also been introduced into the market as options for powering LED devices. More recently, a technology that has long supported non-lighting applications has become increasingly viable for LED lighting. This approach, whereby a single Ethernet cable is used to both provide low-voltage DC power and enable network communication, is generally referred to as Power over Ethernet (PoE). Whereas wireless solutions offer reduced control system installation cost relative to traditional low-voltage alternatives, PoE technology can offer additional cost savings by transmitting power and communications over the same low-voltage cable, while also reducing demand for wireless bandwidth. Although PoE technology was introduced at the start of this century, it was initially of limited applicability to lighting systems to power transmission limits for available Ethernet cabling. However, PoE has become increasingly viable for lighting applications in recent years as Ethernet cabling technology has evolved and relevant standards and specifications have adapted. These gains have been compounded by ongoing improvements to the luminous efficacy of LED technologies, increasing the number of LED luminaires suitable for use with Ethernet switches capable of sourcing PoE. As a result, a growing number of manufacturers have introduced PoE lighting systems in recent years. Connected lighting systems that can report their own energy consumption can deliver increased energy savings over conventional lighting solutions by facilitating data-driven energy management. PoE technology has the potential to be key in bringing this capability to mainstream lighting applications. This study is the first of a multi-part effort to explore the energy reporting capability of commercially-marketed PoE connected lighting systems. It first provides a brief background on the development of the various PoE technologies, ranging from standards-based to proprietary, and illustrates the convergence of PoE power sourcing capabilities and LED luminaire power requirements. It then classifies PoE system devices in relationship to how they are used in systems—introducing new terminology as needed—and briefly describes different PoE system architectures implemented by various lighting manufacturers. A discussion of existing standards and specifications that address energy reporting is provided, and existing test setups and methods germane to characterizing PoE system energy reporting performance are reviewed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Contributing to Net Zero Building: High Energy Efficient EIFS Wall Systems

The team led by Dow Corning collaborated to increase the thermal performance of exterior insulation and finishing systems (EIFS) to reach R-40 performance meeting the needs for high efficiency insulated walls. Additionally, the project helped remove barriers to using EIFS on retrofit commercial buildings desiring high insulated walls. The three wall systems developed within the scope of this project provide the thermal performance of R-24 to R-40 by incorporating vacuum insulation panels (VIPs) into an expanded polystyrene (EPS) encapsulated vacuum insulated sandwich element (VISE). The VISE was incorporated into an EIFS as pre-engineered insulation boards. The VISE is installed using typical EIFS details and network of trained installers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The economics of solar powered absorption cooling

Analytic procedure evaluates cost of combining absorption-cycle chiller with solar-energy system in residential or commercial application. Procedure assumes that solar-energy system already exists to heat building and that cooling system must be added. Decision is whether to cool building with conventional vapor-compression-cycle chiller or to use solar-energy system to provide heat input to absorption chiller.

Bartlett, J. C.↗