Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Free stream noise and transition measurements in a Mach 3.5 pilot quiet tunnel

Free stream fluctuating pressures are determined from hot-wire measurements in a Mach 3.5 pilot quiet nozzle over a unit Reynolds number range from 10-60 million per meter. Further, the transition Reynolds numbers on a sharp tip 5 degree half-angle cone at zero angle of attack are obtained over the same range of unit Reynolds numbers from equilibrium temperature measurements on the cone. Results show that the nozzle provides noise levels in the upstream regions of the test rhombus that are substantially lower than in conventional nozzles. The normalized rms levels of the fluctuating static pressures are found to vary from extremely low values of less than 0.03% up to about 0.8% depending on the unit Reynolds number, the axial location in the test rhombus, and the bleed slot flow. By opening the boundary-layer bleed flow, the wall boundary layers over upstream regions of the nozzle become laminar and the absence of high frequency radiated noise then results in cone transition Reynolds numbers that are in the range of free-flight data. As the unit Reynolds numbers are increased, the nozzle wall boundary layers become transitional and turbulent, and the noise increases to peak levels of about 0.5% with significant energy up to 150 KHz. The cone transition Reynolds numbers then decrease to values that are in the range of those measured in conventional wind tunnels.

Beckwith, I. E.↗

IMRT Reirradiation of Head and Neck Cancer-Disease Control and Morbidity Outcomes

Purpose: Institutional and cooperative group experience has demonstrated the feasibility of reirradiation for head and neck cancer. Limited data are available regarding the use of intensity-modulated radiotherapy (IMRT) for this indication. We reviewed our initial experience using IMRT for previously irradiated head and neck cancer patients. Methods and Materials: Records of 78 consecutive patients reirradiated with IMRT for head and neck cancer between 1999 and 2004 were reviewed; 74 cases were analyzed. Reirradiation was defined as any overlap between original and new radiation treatment volumes regardless of the time interval between initial and subsequent treatment. Severe reirradiation-related toxicity was defined as toxic events resulting in hospitalization, corrective surgery, or patient death. Longitudinal estimates of survival were calculated by Kaplan-Meier technique. Results: Twenty (27%) patients underwent salvage surgical resection and 36 (49%) patients received chemotherapy. Median follow-up from reirradiation was 25 months. Median time interval between initial radiation and reirradiation was 46 months. Median reirradiation dose was 60 Gy. Median lifetime radiation dose was 116.1 Gy. The 2-year overall survival and locoregional control rates were 58% and 64%, respectively. Severe reirradiation related toxicity occurred in 15 patients (20%); one treatment-related death was observed. Conclusions: The use of IMRT for reirradiation of recurrent or second primary head and neck cancers resulted in encouraging local control and survival. Reirradiation-related morbidity was significant, but may be less severe than previously published reports using conventional techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiative strength functions from the energy-localized Brink-Axel hypothesis

Radiative strength functions (RSFs) model the bulk electromagnetic response of highly excited nuclei and are critical inputs for statistical reaction codes. In this paper, we present a definition of the RSF that is consistent with Hauser-Feshbach reaction codes and that can be efficiently computed with the shell model using the Lanczos strength-function (LSF) method. Here, we introduce a variant of the shell-model LSF method that exploits the energy-localized Brink-Axel hypothesis, which makes it possible to compute both electric and magnetic RSFs across all energies relevant to capture reactions. We verify agreement with the conventional definition of RSFs with benchmark calculations of 24 Mg and then present novel results for 56 Fe. For 56 Fe we find that (i) the 𝑀⁢1 RSF shape evolves smoothly with excitation energy, consistent with the energy-localized Brink-Axel hypothesis; (ii) both 𝑀⁢1 and 𝐸⁢1 transitions contribute significantly to the radiative strength below the photoabsorption threshold; and (iii) within the sdpf model space, the strength below 3 MeV observed in Oslo-type experiments cannot be fully reproduced. These results pave the way for a coherent microscopic description of RSFs and further motivate the use of energy-dependent RSFs in modern reaction codes.

Physics - Nuclear physics and radiation physics↗

SU-F-T-538: CyberKnife with MLC for Treatment of Large Volume Tumors: A Feasibility Study

Purpose: CyberKnife is a well-documented modality for SRS and SBRT treatments. Typical tumors are small and 1–5 fractions are usually used. We determined the feasibility of using CyberKnife, with an InCise multileaf collimator option, for larger tumors undergoing standard dose and fractionation. The intent was to understand the limitation of using this modality for other external beam radiation treatments. Methods: Five tumors from different anatomical sites with volumes from 127.8 cc to 1,320.5 cc were contoured and planned on a Multiplan V5.1 workstation. The target average diameter ranged from 7 cm to 13 cm. The dose fractionation was 1.8–2.0 Gy/fraction and 25–45 fractions for total doses of 45–81 Gy. The sites planned were: pancreas, head and neck, prostate, anal, and esophagus. The plans were optimized to meet conventional dose constraints based on various RTOG protocols for conventional fractionation. Results: The Multiplan treatment planning system successfully generated clinically acceptable plans for all sites studied. The resulting dose distributions achieved reasonable target coverage, all greater than 95%, and satisfactory normal tissue sparing. Treatment times ranged from 9 minutes to 38 minutes, the longest being a head and neck plan with dual targets receiving different doses and with multiple adjacent critical structures. Conclusion: CyberKnife, with the InCise multileaf collimation option, can achieve acceptable dose distributions in large volume tumors treated with conventional dose and fractionation. Although treatment times are greater than conventional accelerator time; target coverage and dose to critical structures can be kept within a clinically acceptable range. While time limitations exist, when necessary CyberKnife can provide an alternative to traditional treatment modalities for large volume tumors.

60 APPLIED LIFE SCIENCES↗

Dark progression reveals slow timescales for radiation damage between T = 180 and 240 K

Between T = 180 and 240 K, radiation damage progresses on minute timescales when the X-rays are off, suggesting that a fraction of damage at higher temperatures may be outrun using currently available sources and detectors. Can radiation damage to protein crystals be ‘outrun’ by collecting a structural data set before damage is manifested? Recent experiments using ultra-intense pulses from a free-electron laser show that the answer is yes. Here, evidence is presented that significant reductions in global damage at temperatures above 200 K may be possible using conventional X-ray sources and current or soon-to-be available detectors. Specifically, ‘dark progression’ (an increase in damage with time after the X-rays have been turned off) was observed at temperatures between 180 and 240 K and on timescales from 200 to 1200 s. This allowed estimation of the temperature-dependent timescale for damage. The rate of dark progression is consistent with an Arrhenius law with an activation energy of 14 kJ mol{sup −1}. This is comparable to the activation energy for the solvent-coupled diffusive damage processes responsible for the rapid increase in radiation sensitivity as crystals are warmed above the glass transition near 200 K. Analysis suggests that at T = 300 K data-collection times of the order of 1 s (and longer at lower temperatures) may allow significant reductions in global radiation damage, facilitating structure solution on crystals with liquid solvent. No dark progression was observed below T = 180 K, indicating that no important damage process is slowed through this timescale window in this temperature range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proton-minibeam radiation therapy: A proof of concept

Purpose: This Monte Carlo simulation work aims at studying a new radiotherapy approach called proton-minibeam radiation therapy (pMBRT). The main objective of this proof of concept was the evaluation of the possible gain in tissue sparing, thanks to the spatial fractionation of the dose, which could be used to deposit higher and potentially curative doses in clinical cases where tissue tolerances are a limit for conventional methods. Methods: Monte Carlo simulations (GATE v.6) have been used as a method to calculate the ratio of the peak-to-valley doses (PVDR) for arrays of proton minibeams of 0.7 mm width and several center-to-center distances, at different depths in a water phantom. The beam penumbras were also evaluated as an important parameter for tissue sparing, for example, in the treatment of non-cancer diseases like epilepsy. Two proton energies were considered in this study: a clinically relevant energy (105 MeV) and a very high energy (1 GeV), to benefit from a reduced lateral scattering. For the latter case, an interlaced geometry was also evaluated. Results: Higher or similar PVDR than the ones obtained in x-rays minibeam radiation therapy were achieved in several pMBRT configurations. In addition, for the two energies studied, the beam penumbras are smaller than in the case of Gamma Knife radiosurgery. Conclusions: The high PVDR obtained for some configurations and the small penumbras in comparison with existing radiosurgery techniques, suggest a potential gain in healthy tissue sparing in this new technique. Biological studies are warranted to assess the effects of pMBRT on both normal and tumoral tissues.

60 APPLIED LIFE SCIENCES↗

Automated treatment planning for a dedicated multi-source intra-cranial radiosurgery treatment unit accounting for overlapping structures and dose homogeneity

Purpose: The purpose of this work is to advance the two-step approach for Gamma Knife{sup ®} Perfexion™ (PFX) optimization to account for dose homogeneity and overlap between the planning target volume (PTV) and organs-at-risk (OARs).Methods: In the first step, a geometry-based algorithm is used to quickly select isocentre locations while explicitly accounting for PTV-OARs overlaps. In this approach, the PTV is divided into subvolumes based on the PTV-OARs overlaps and the distance of voxels to the overlaps. Only a few isocentres are selected in the overlap volume, and a higher number of isocentres are carefully selected among voxels that are immediately close to the overlap volume. In the second step, a convex optimization is solved to find the optimal combination of collimator sizes and their radiation duration for each isocentre location.Results: This two-step approach is tested on seven clinical cases (comprising 11 targets) for which the authors assess coverage, OARs dose, and homogeneity index and relate these parameters to the overlap fraction for each case. In terms of coverage, the mean V{sub 99} for the gross target volume (GTV) was 99.8% while the V{sub 95} for the PTV averaged at 94.6%, thus satisfying the clinical objectives of 99% for GTV and 95% for PTV, respectively. The mean relative dose to the brainstem was 87.7% of the prescription dose (with maximum 108%), while on average, 11.3% of the PTV overlapped with the brainstem. The mean beam-on time per fraction per dose was 8.6 min with calibration dose rate of 3.5 Gy/min, and the computational time averaged at 205 min. Compared with previous work involving single-fraction radiosurgery, the resulting plans were more homogeneous with average homogeneity index of 1.18 compared to 1.47.Conclusions: PFX treatment plans with homogeneous dose distribution can be achieved by inverse planning using geometric isocentre selection and mathematical modeling and optimization techniques. The quality of the obtained treatment plans are clinically satisfactory while the homogeneity index is improved compared to conventional PFX plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertically Integrated Circuits at Fermilab

The exploration of the vertically integrated circuits, also commonly known as 3D-IC technology, for applications in radiation detection started at Fermilab in 2006. This paper examines the opportunities that vertical integration offers by looking at various 3D designs that have been completed by Fermilab. The emphasis is on opportunities that are presented by through silicon vias (TSV), wafer and circuit thinning and finally fusion bonding techniques to replace conventional bump bonding. Early work by Fermilab has led to an international consortium for the development of 3D-IC circuits for High Energy Physics. The consortium has submitted over 25 different designs for the Fermilab organized MPW run organized for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiparticle Simulation of Intrabeam Scattering for SuperB

In this communication we present the structure of a multiparticle tracking code to investigate intrabeam scattering effects in low emittance colliders. Simulation results obtained with particular reference to the SuperB parameters are compared with those of conventional IBS theories.and with those of a novel semi-analythical model able to predict IBS effect in terms of emittance growths. Intrabeam scattering (IBS) is associated with multiple small angle scattering events leading to emittance growth. In most electron storage rings, the growth rates arising from IBS are usually much longer than damping times due to synchrotron radiation, and its effect is not observed. However, IBS growth rates increase with bunch charge density, and for machines such as SuperB, that operate with high bunch charges and very low emittances, the IBS growth rates can be large enough to observe significant emittance increase. Several formalisms have been developed for calculating IBS growth rates in storage rings, notably those by Piwinski, Bjorken and Mtingwa, and their high energy approximations. Calculations show that IBS should be manageable in both SuperB rings. However these analytical models, based on Gaussian bunch distributions, cannot investigate some interesting aspects of IBS such as its impact during the damping process and its effect on the beam distribution. We developed a multiparticle tracking code, based on the Zenkevich-Bolshakov algorithm, to investigate these effects. In this communication we present the structure of the code and some simulation results obtained with particular reference to the SuperB parameters. Simulation results are compared with those of conventional IBS theories.

43 PARTICLE ACCELERATORS↗

Production of 35S for a Liquid Semiconductor Betavoltaic

The specific energy density from radioactive decay is five to six orders of magnitude greater than the specific energy density in conventional chemical battery and fuel cell technologies. We are currently investigating the use of liquid semiconductor based betavoltaics as a way to directly convert the energy of radioactive decay into electrical power and potentially avoid the radiation damage that occurs in solid state semiconductor devices due to non-ionizing energy loss. Sulfur-35 was selected as the isotope for the liquid semiconductor demonstrations because it can be produced in high specific activity and it is chemically compatible with known liquid semiconductor media.

30 DIRECT ENERGY CONVERSION↗

Hyperparathyroidism After Irradiation for Childhood Malignancy

Purpose: To examine the occurrence of hyperparathyroidism in a cohort of patients undergoing combined parathyroid and thyroid surgery after previous head-and-neck irradiation for childhood malignancy. Methods and Materials: This is a retrospective cohort study for the years 1996 to 2007. The study group comprised patients undergoing surgery in University of Sydney Endocrine Surgical Unit who had received previous head-and-neck irradiation in childhood and who were identified as having pathologic thyroid and parathyroid characteristics. Results: A total of 53 patients were identified in whom head-and-neck irradiation for the treatment of childhood malignancy had been documented. In each of the cases, thyroid disease was the primary reason for referral for surgery. Five of these patients (10%) were found to exhibit coexisting hyperparathyroidism. The latency period for hyperparathyroidism was less than 20 years in 4 of the 5 cases. There were four conventional parathyroid adenomas and one parathyroid lipoadenoma. All patients exhibited a significant decrease in postoperative calcium levels after surgery. Conclusions: To our knowledge, this is the first study to document the significant risk of hyperparathyroidism after radiation exposure for childhood malignancy. The timeframe for development of disease is much shorter than that published for individuals who have undergone irradiation for benign diseases. High doses of therapeutic radiation at a young age make childhood survivors of malignancy at especially high risk for developing hyperparathyroidism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiosurgery for Treatment of Spinal Metastases Recurring in Close Proximity to Previously Irradiated Spinal Cord

Purpose: As the spinal cord tolerance often precludes reirradiation with conventional techniques, local recurrence within a previously irradiated field presents a treatment challenge. Methods and Materials: We retrospectively reviewed 51 lesions in 42 patients treated from 2002 to 2008 whose spinal metastases recurred in a previous radiation field (median previous spinal cord dose of 40 Gy) and were subsequently treated with stereotactic radiosurgery (SRS). Results: SRS was delivered to a median marginal dose of 20 Gy (range, 10-30 Gy) in 1-5 fractions (median, 2), targeting a median tumor volume of 10.3 cm{sup 3} (range, 0.2-128.6 cm{sup 3}). Converting the SRS regimens with the linear quadratic model ({alpha}/{beta} = 3), the median spinal cord maximum single-session equivalent dose (SSED) was 12.1 Gy{sub 3} (range, 4.7-19.3 Gy{sub 3}). With a median follow-up of 7 months (range, 2-47 months), the Kaplan-Meier local control and overall survival rates at 6/12 months were 87%/73% and 81%/68%, respectively. A time to retreatment of {<=}12 months and the combination of time to retreatment of {<=}12 months with an SSED of <15 Gy{sub 10} were significant predictors of local failure on univariate and multivariate analyses. In patients with a retreatment interval of <12 months, 6/12 month local control rates were 88%/58%, with a SSED of >15 Gy{sub 10}, compared to 45%/0% with <15 Gy{sub 10}, respectively. One patient (2%) experienced Grade 4 neurotoxicity. Conclusion: SRS is safe and effective in the treatment of spinal metastases recurring in previously irradiated fields. Tumor recurrence within 12 months may correlate with biologic aggressiveness and require higher SRS doses (SSED >15 Gy{sub 10}). Further research is needed to define the partial volume retreatment tolerance of the spinal cord and the optimal target dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative study of fatigue properties of Ti-6Al-4V specimens built by electron beam melting (EBM) and selective laser melting (SLM)

Highlights: • EBM and SLM parts have similar fatigue properties, equivalent to cast alloys. • Surface defects are more critical than unmelted zones and internal small defects. • HIP treatment largely improves lifetimes compared to as-built specimens. - Abstract: Electron Beam Melting (EBM) and Selective Laser Melting (SLM) are two of the most developed powder bed fusion based additive manufacturing processes. In this paper, fatigue properties of Ti-6Al-4V specimens built by EBM and SLM are compared. Several parameters are assessed: processes, manufacturing direction, surface roughness, HIP treatment. Fatigue properties are analyzed in relation with the crack initiation mechanisms identified on each specimen's post-mortem micrographs. Machined specimens show better fatigue properties as surface defects are removed. HIP treatment improves fatigue properties by decreasing the defects size. Small differences in lifetime are observed between horizontal and vertical building directions because of different defect shapes regarding the loading axis. Finally, EBM and SLM parts have approximately the same fatigue properties, which are equivalent to conventional casting processes.

36 MATERIALS SCIENCE↗

Enhanced luminescence properties of YBO{sub 3}:Eu{sup 3+} phosphors by Li-doping

Different concentrations of Li-doped YBO{sub 3}:Eu{sup 3+} phosphors have been prepared by the conventional solid state reaction method and were characterized by X-ray diffraction, field emission scanning electron microscopy, photoluminescence excitation and emission measurements. An intense reddish orange emission is observed under UV excitation and the emitted radiation was dominated by an orange peak at 594 nm resulted from the {sup 5}D{sub 0} {yields} {sup 7}F{sub 1} transitions of Eu{sup 3+} ions. The brightness of the YBO{sub 3}:Eu{sup 3+} phosphor was found greatly improved with Li-doping accompanied by slight improvement in the purity of the color which might be attributed to improvement in crystallinity, grain sizes and creation of oxygen vacancies with Li-doping. The observed results have been discussed in comparison with similar reported works.

36 MATERIALS SCIENCE↗

A study of thermal properties of sodium titanate nanotubes synthesized by microwave-assisted hydrothermal method

Highlights: • The microwave-assisted hydrothermal route was used for titanate nanotubes synthesis. • Conversion to single-phase nanotube morphology completes after 8 h reaction time. • The nanotube morphology is stable up to 600 °C, as determined by in-situ XRD and SEM. • Sodium ions migrate to the surface due to thermal motion and structure condensation. - Abstract: Sodium titanate nanotubes (NaTiNTs) were synthesized by microwave-assisted hydrothermal treatment of commercial TiO{sub 2}, at constant temperature (135 °C) and different irradiation times (15 min, 1, 4, 8 and 16 h). The products were characterized by X-ray diffraction, scanning electron microscopy, transmission electron microscopy, differential scanning calorimetry and specific surface area measurements. The irradiation time turned out to be the key parameter for morphological control of the material. Nanotubes were observed already after 15 min of microwave irradiation. The analyses of the products irradiated for 8 and 16 h confirm the complete transformation of the starting TiO{sub 2} powder to NaTiNTs. The nanotubes are open ended with multi-wall structures, with the average outer diameter of 8 nm and specific surface area up to 210 m{sup 2}/g. The morphology, surface area and crystal structure of the sodium titanate nanotubes synthesized by microwave-assisted hydrothermal method were similar to those obtained by conventional hydrothermal method.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Photoacoustic phasoscopy super-contrast imaging

Phasoscopy is a recently proposed concept correlating electromagnetic (EM) absorption and scattering properties based on energy conservation. Phase information can be extracted from EM absorption induced acoustic wave and scattered EM wave for biological tissue characterization. In this paper, an imaging modality, termed photoacoustic phasoscopy imaging (PAPS), is proposed and verified experimentally based on phasoscopy concept with laser illumination. Both endogenous photoacoustic wave and scattered photons are collected simultaneously to extract the phase information. The PAPS images are then reconstructed on vessel-mimicking phantom and ex vivo porcine tissues to show significantly improved contrast than conventional photoacoustic imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automated laser-based barely visible impact damage detection in honeycomb sandwich composite structures

Nondestructive evaluation (NDE) for detection and quantification of damage in composite materials is fundamental in the assessment of the overall structural integrity of modern aerospace systems. Conventional NDE systems have been extensively used to detect the location and size of damages by propagating ultrasonic waves normal to the surface. However they usually require physical contact with the structure and are time consuming and labor intensive. An automated, contactless laser ultrasonic imaging system for barely visible impact damage (BVID) detection in advanced composite structures has been developed to overcome these limitations. Lamb waves are generated by a Q-switched Nd:YAG laser, raster scanned by a set of galvano-mirrors over the damaged area. The out-of-plane vibrations are measured through a laser Doppler Vibrometer (LDV) that is stationary at a point on the corner of the grid. The ultrasonic wave field of the scanned area is reconstructed in polar coordinates and analyzed for high resolution characterization of impact damage in the composite honeycomb panel. Two methodologies are used for ultrasonic wave-field analysis: scattered wave field analysis (SWA) and standing wave energy analysis (SWEA) in the frequency domain. The SWA is employed for processing the wave field and estimate spatially dependent wavenumber values, related to discontinuities in the structural domain. The SWEA algorithm extracts standing waves trapped within damaged areas and, by studying the spectrum of the standing wave field, returns high fidelity damage imaging. While the SWA can be used to locate the impact damage in the honeycomb panel, the SWEA produces damage images in good agreement with X-ray computed tomographic (X-ray CT) scans. The results obtained prove that the laser-based nondestructive system is an effective alternative to overcome limitations of conventional NDI technologies.

36 MATERIALS SCIENCE↗

Variation of photoluminescence features in Pr{sup 3+} doped lithium-fluoro-borate glass by changing different modifier oxides (MgO, CaO, CdO and PbO)-Judd-Ofelt theory application

Pr{sup 3+} (1.0 mol%) doped different modifier oxide based six lithium-fluoro-borate glasses with chemical composition of 49Li{sub 2}B{sub 4}O{sub 7}-20BaF{sub 2}-10NaF-20MO (where M= Mg, Ca, Cd and Pb), 49Li{sub 2}B{sub 4}O{sub 7}-20BaF{sub 2}-10NaF-10MgO-10CaO and 49Li{sub 2}B{sub 4}O{sub 7}-20BaF{sub 2}-10NaF-10CdO-10PbO were prepared by conventional melt quenching technique. Judd-Ofelt theory has been applied for evaluating the Judd-Ofelt intensity parameters for Pr{sup 3+} ion in these glass compositions and are in turn to used to predict radiative properties such as radiative transition probabilities (A{sub T}), branching ratios (β) and stimulated emission cross-section (σ{sub P}). Stimulated emission cross-section (σ{sub p}) of prominent emission transitions, {sup 3}P{sub 0}→{sup 3}H{sub 4} and {sup 1}D{sub 2}→{sup 3}H{sub 4} of Pr{sup 3+} ion in all lithium-fluoro-borate glasses were calculated. Among all the emission transitions, {sup 3}P{sub 0}→{sup 3}H{sub 4} posseses higher branching ratio and stimulated emission cross-section in Mg-Ca glass, which leads to the best laser excitation at 487 nm wavelength.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗