Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT-VI algorithms might have varying accuracy depending on the underlying cause of ventilation abnormality. This research was supported by a National Health and Medical Research Council (NHMRC) Australia Fellowship, an Cancer Institute New South Wales Early Career Fellowship 13-ECF-1/15 and NHMRC scholarship APP1038399. No commercial funding was received for this work.

60 APPLIED LIFE SCIENCES↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automating High-Precision X-Ray and Neutron Imaging Applications with Robotics

Los Alamos National Laboratory and the University of Texas at Austin recently implemented a robotically controlled nondestructive testing (NDT) system for X-ray and neutron imaging. This system is intended to address the need for accurate measurements for a variety of parts and, be able to track measurement geometry at every imaging location, and is designed for high-throughput applications. This system was deployed in a beam port at a nuclear research reactor and in an operational inspection X-ray bay. The nuclear research reactor system consisted of a precision industrial seven-axis robot, 1.1-MW TRIGA research reactor, and a scintillator-mirror-camera-based imaging system. The X-ray bay system incorporated the same robot, a 225-keV microfocus X-ray source, and a custom flat panel digital detector. The robotic positioning arm is programmable and allows imaging in multiple configurations, including planar, cylindrical, as well as other user defined geometries that provide enhanced engineering evaluation capability. The imaging acquisition device is coupled with the robot for automated image acquisition. The robot can achieve target positional repeatability within 17 μm in the 3-D space. Flexible automation with nondestructive imaging saves costs, reduces dosage, adds imaging techniques, and achieves better quality results in less time. Specifics regarding the robotic system and imaging acquisition and evaluation processes are presented. In conclusion, this paper reviews the comprehensive testing and system evaluation to affirm the feasibility of robotic NDT, presents the system configuration, and reviews results for both X-ray and neutron radiography imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-170: Evaluation of Rotational Errors in Proton Therapy Planning of Lung Cancer

Purpose: To investigate the impact of rotational (roll, yaw, and pitch) errors in proton therapy planning of lung cancer. Methods: A lung cancer case treated at our center was used in this retrospective study. The original plan was generated using two proton fields (posterior-anterior and left-lateral) with XiO treatment planning system (TPS) and delivered using uniform scanning proton therapy system. First, the computed tomography (CT) set of original lung treatment plan was re-sampled for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. Second, 12 new proton plans were generated in XiO using the 12 re-sampled CT datasets. The same beam conditions, isocenter, and devices were used in new treatment plans as in the original plan. All 12 new proton plans were compared with original plan for planning target volume (PTV) coverage and maximum dose to spinal cord (cord Dmax). Results: PTV coverage was reduced in all 12 new proton plans when compared to that of original plan. Specifically, PTV coverage was reduced by 0.03% to 1.22% for roll, by 0.05% to 1.14% for yaw, and by 0.10% to 3.22% for pitch errors. In comparison to original plan, the cord Dmax in new proton plans was reduced by 8.21% to 25.81% for +2.5° to +5° pitch, by 5.28% to 20.71% for +2.5° to +5° yaw, and by 5.28% to 14.47% for −2.5° to −5° roll. In contrast, cord Dmax was increased by 3.80% to 3.86% for −2.5° to −5° pitch, by 0.63% to 3.25% for −2.5° to −5° yaw, and by 3.75% to 4.54% for +2.5° to +5° roll. Conclusion: PTV coverage was reduced by up to 3.22% for rotational error of 5°. The cord Dmax could increase or decrease depending on the direction of rotational error, beam angles, and the location of lung tumor.

60 APPLIED LIFE SCIENCES↗

SU-E-T-198: Hippocampal-Sparing Radiotherapy (HSRT) for Patients with Head and Neck Cancer (HNC) Using Intensity-Modulated Radiation Therapy (IMRT)

Purpose: There is increasing evidence that decline in cognitive function following brain radiotherapy (RT) is related to the radiation dose delivered to the hippocampi. In this work we evaluate the feasibility of using IMRT to generate HSRT plans in HNC. Methods: A planning study was undertaken for ten representative patients with HNC previously treated with radical (chemo)-RT using standard IMRT techniques. The hippocampi were delineated according to the RTOG hippocampal contouring atlas, on a T1w- MRI scan that was registered with the RT planning CT. LINAC-based, clinically acceptable, HSRT plans were generated and assessed using the Pinnacle3 treatment planning system. Results: Using a VMAT technique, a reduction in hippocampal dose was achievable in six cases. For these cases, the EQD2-D40% of the bilateral hippocampi was significantly reduced by HSRT (p = 0.006) from a median of 18.8Gy (range 14.4–34.6) to 6.5 Gy (4.2–9.5) for the delivered and HSRT plans respectively. Plans were also generated using a fixed-field IMRT technique with non-coplanar beams that were designed to avoid the bilateral hippocampi, resulting in a median EQD2-D40% of 11.2Gy (8.0–14.5). Both HSRT techniques also resulted in lower doses to the whole brain, brain stem, and cerebellum. The HSRT plans resulted in higher doses to some regions of non-contoured normaltissue, but the magnitude of these dose differences is unlikely to be of clinical significance in terms of acute and late toxicity. Conclusion: This study has demonstrated that it is possible, in many cases, to adapt treatment plans for HNC to significantly reduce dose to the hippocampi. This reduction in dose would be predicted to Resultin a significant reduction in the probability of subsequent decline in cognitive function following RT. Our results point towards the need for the collection of prospective data on cognitive outcomes for the HNC patient population treated with radical (chemo)-RT.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-02: Incorporating Uncertainty Analysis in Plan Comparison of VMAT, Double Scattering Proton Plan and IMPT for Lung Irradiation

Purpose: We investigate the effect of residual setup and motion errors in lung irradiation for VMAT, double scattering (DS) proton beams and spot scanning (IMPT) in a case study. Methods: The CT image and contour sets of a lung patient treated with 6 MV VMAT is re-planned with DS as well as IMPT subject to the same constraints; V20(lung), V10(lung) and V5(lung)< 15%, 20% and 25% respectively, V20(heart)<25% and V100%(PTV)≥95%. In addition, uncertainty analysis in the form of isocenter shifts (±1–3mm) was incorporated in the DVH calculations to assess the plan robustness. Results: Only the IMPT plan satisfies all the specified constraints. The 3D-conformal DS proton plan is able to achieve better sparing of the lung and heart dose compared to VMAT. For the lung, V20, V10 and V5 are 13%, 19% and 25% respectively for IMPT, 18%, 23% and 30% respectively for DS, and 20%, 30% and 42% respectively for VMAT. For heart: 0.6% for IMPT, 2.4% for DS and 30% for VMAT. When incorporating isocenter shifts in DVH calculations, the maximum changes in V20, V10 and V5 for lung are 14%, 21% and 28% respectively for IMPT. The corresponding max changes are19%, 24% and 32% respectively for DS, and 22%, 32% and 44% respectively for VMAT. The largest change occurs in the PTV coverage. For IMPT, V100%(PTV) varies between 88–96%, while V100%(PTV) for VMAT suffers a larger change compared to DS (Δ=5.5% vs 3.3%). Conclusion: While only IMPT satisfies the stringent dose-volume constraints for the lung irradiation, it is not as robust as the 3D conformal DS plan. DS also has better sparing in lung and heart compared to VMAT and similar PTV coverage. By including isocenter shifts in dose-volume calculations in treatment planning of lung, DS appears to be more robust than VMAT.

60 APPLIED LIFE SCIENCES↗

TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗

Flash Thermal Diffusivity Measurements and Inspection of Additively Manufactured Ti-6Al-4V Specimens with Varying Process Parameters

Flash thermal diffusivity measurements were obtained on additively manufactured Ti-6Al-4V disk shaped specimens with various process parameters. For additively manufactured metal parts, processing parameters such as laser power and scanning speed are critical to ensure the desired microstructure. For this study, the laser powder bed fusion process parameters were changed at various angular sections on a 21 mm diameter and 3.0 mm thick disk. The measurement of thermal diffusivity was performed by fitting a 1-dimensional thermal model to the data pixel by pixel to produce an inspection image. The image revealed the detection of defects such as lack of fusion porosity and areas of aggregated porosity. The thermal diffusivity imagery was compared to immersion scan ultrasonic and X-ray computed tomography (CT) measurements for validation. Based on these results, additional samples were investigated using a single side thermal inspection technique to detect lack of fusion porosity and near surface voids.

thermal nondestructive evaluation↗

SU-E-J-19: An Intra-Institutional Study of Cone-Beam CT Dose for Image-Guided Radiation Therapy

Purpose: To determine the variability of Cone-Beam CT Dose Index (CB-CTDI) across multiple on-board imaging (OBI) systems within a single institution, and compare this to manufacturer provided data. Methods: The CB-CTDI was measured on three Trilogy and three TrueBeam Varian OBI systems, for six different clinically used scan protocols. Measurements were taken using a 10 cm long CT ionization chamber in either a 16 cm (head-simulating) or 32 cm (body-simulating) diameter, acrylic, cylindrical, 15 cm long CTDI phantom. We assessed the variation in CB-CTDI between the OBI systems and compared our measured values to the data provided by the manufacturer. Results: The standard error in the CB-CTDI measured for all protocols was found to be within ±2% and ±5% of the mean for TrueBeam and Trilogy, respectively. For all head scan protocols, the measured TrueBeam values were lower than the manufacturer’s reported values, with a maximum difference of 13.9% and an average difference of 11%. For the body scan protocols, the TrueBeam measured values were 3% and 13% greater than the manufacturer’s reported values for two out of three protocols, and 38% lower than reported for the third protocol. In total, 7/18 CB-CTDI measurements fell within the manufacturers specified range (±10%). Across all scans the Truebeam machines were found to have a lower CB-CTDI than Trilogy, particularly the head scan protocols, which show decreases of up to 30% . Conclusion: The intra-institutional variation of CB-CTDI was found to be clinically acceptable at less than 5%. For the TrueBeam OBI system, over half of the measured scans failed to fall with in the manufactured quoted range of 10%, however, all measured values were within 15% of the manufacturer’s reported values. For accurate assessment and reporting of imaging dose to radiotherapy patients, our results indicate a need for standardization in CB-CTDI measurement technique.

60 APPLIED LIFE SCIENCES↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prospective estimation of organ dose in CT under tube current modulation

Purpose: Computed tomography (CT) has been widely used worldwide as a tool for medical diagnosis and imaging. However, despite its significant clinical benefits, CT radiation dose at the population level has become a subject of public attention and concern. In this light, optimizing radiation dose has become a core responsibility for the CT community. As a fundamental step to manage and optimize dose, it may be beneficial to have accurate and prospective knowledge about the radiation dose for an individual patient. In this study, the authors developed a framework to prospectively estimate organ dose for chest and abdominopelvic CT exams under tube current modulation (TCM). Methods: The organ dose is mainly dependent on two key factors: patient anatomy and irradiation field. A prediction process was developed to accurately model both factors. To model the anatomical diversity and complexity in the patient population, the authors used a previously developed library of computational phantoms with broad distributions of sizes, ages, and genders. A selected clinical patient, represented by a computational phantom in the study, was optimally matched with another computational phantom in the library to obtain a representation of the patient’s anatomy. To model the irradiation field, a previously validated Monte Carlo program was used to model CT scanner systems. The tube current profiles were modeled using a ray-tracing program as previously reported that theoretically emulated the variability of modulation profiles from major CT machine manufacturers Li et al., [Phys. Med. Biol. 59, 4525–4548 (2014)]. The prediction of organ dose was achieved using the following process: (1) CTDI{sub vol}-normalized-organ dose coefficients (h{sub organ}) for fixed tube current were first estimated as the prediction basis for the computational phantoms; (2) each computation phantom, regarded as a clinical patient, was optimally matched with one computational phantom in the library; (3) to account for the effect of the TCM scheme, a weighted organ-specific CTDI{sub vol} [denoted as (CTDI{sub vol}){sub organ,weighted}] was computed for each organ based on the TCM profile and the anatomy of the “matched” phantom; (4) the organ dose was predicted by multiplying the weighted organ-specific CTDI{sub vol} with the organ dose coefficients (h{sub organ}). To quantify the prediction accuracy, each predicted organ dose was compared with the corresponding organ dose simulated from the Monte Carlo program with the TCM profile explicitly modeled. Results: The predicted organ dose showed good agreements with the simulated organ dose across all organs and modulation profiles. The average percentage error in organ dose estimation was generally within 20% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. For an average CTDI{sub vol} of a CT exam of 10 mGy, the average error at full modulation strength (α = 1) across all organs was 0.91 mGy for chest exams, and 0.82 mGy for abdominopelvic exams. Conclusions: This study developed a quantitative model to predict organ dose for clinical chest and abdominopelvic scans. Such information may aid in the design of optimized CT protocols in relation to a targeted level of image quality.

60 APPLIED LIFE SCIENCES↗

Angioarchitectural Changes in Subacute Cerebral Venous Thrombosis. A Synchrotron-based Micro- and Nano-CT Study

It is well known that recanalization of thrombosed cerebral sinuses occurs early but without marked influence on the long-term outcome and on final venous infarct volume on magnetic resonance imaging. To better understand the possible microvascular mechanisms behind these clinical observations, we evaluated the sequels of subacute superior sagittal sinus (SSS) thrombosis in rats using micro- and nano-CT imaging of the same specimen to provide large volume and high resolution CT image data respectively. SSS thrombosis was induced in 11 animals which were euthanized after 6 h (n = 4) or 6 weeks (n = 7). Eight sham-operated rats served as controls. After infusion of contrast into the vasculature of the brains, these were isolated and scanned using micro-, nano-, and synchrotron-based micro-CT ((8 {mu}m{sup 3}), (900 nm){sup 3}, and (1.9 {mu}m{sup 3}) voxel sizes). The cross-sectional area of the superior sagittal sinus, microvessels and cortical veins were quantified. Tissue sections were stained against VEGF antigen. Immunohistochemistry was confirmed using quantitative rtPCR. SSS thrombosis led to a congestion of the bridging veins after 6 h. After 6 weeks, a network of small vessels surrounding the occluded SSS was present with concurrent return towards the diameter of the draining bridging veins of controls. This microvascular network connected to cortical veins as demonstrated by nano- and synchrotron-based micro-CT. Also the volume fraction and number of cortical veins increased significantly. Immunohistochemistry in the region of the microsvascular network demonstrated a strong immunoreactivity against VEGF, confirmed by rtPCR. The sequel of subacute SSS thrombosis induced a network of microvessels ('venogenesis') draining the bridging veins. Also the volume fraction of cortical veins increased significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A rapid noninvasive characterization of CT x-ray sources

Purpose: The aim of this study is to generate spatially varying half value layers (HVLs) that can be used to construct virtual equivalent source models of computed tomography (CT) x-ray sources for use in Monte Carlo CT dose computations. Methods: To measure the spatially varying HVLs, the authors combined a cylindrical HVL measurement technique with the characterization of bowtie filter relative attenuation (COBRA) geometry. An apparatus given the name “HVL Jig” was fabricated to accurately position a real-time dosimeter off-isocenter while surrounded by concentric cylindrical aluminum filters (CAFs). In this geometry, each projection of the rotating x-ray tube is filtered by an identical amount of high-purity (type 1100 H-14) aluminum while the stationary radiation dose probe records an air kerma rate versus time waveform. The CAFs were progressively nested to acquire exposure data at increasing filtrations to calculate the HVL. Using this dose waveform and known setup geometry, each timestamp was related to its corresponding fan angle. Data were acquired using axial CT protocols (i.e., rotating tube and stationary patient table) at energies of 80, 100, and 120 kVp on a single CT scanner. These measurements were validated against the more laborious conventional step-and-shoot approach (stationary x-ray tube). Results: At each energy, HVL data points from the COBRA-cylinder technique were fit to a trendline and compared with the conventional approach. The average relative difference in HVL between the two techniques was 1.3%. There was a systematic overestimation in HVL due to scatter contamination. Conclusions: The described method is a novel, rapid, accurate, and noninvasive approach that allows one to acquire the spatially varying fluence and HVL data using a single experimental setup in a minimum of three scans. These measurements can be used to characterize the CT beam in terms of the angle-dependent fluence and energy spectra along the bowtie filter direction, which can serve as input for accurate CT dose computations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance

Purpose: Statistical model based iterative reconstruction (MBIR) methods have been introduced to clinical CT systems and are being used in some clinical diagnostic applications. The purpose of this paper is to experimentally assess the unique spatial resolution characteristics of this nonlinear reconstruction method and identify its potential impact on the detectabilities and the associated radiation dose levels for specific imaging tasks. Methods: The thoracic section of a pediatric phantom was repeatedly scanned 50 or 100 times using a 64-slice clinical CT scanner at four different dose levels [CTDI{sub vol} =4, 8, 12, 16 (mGy)]. Both filtered backprojection (FBP) and MBIR (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for image reconstruction and results were compared with one another. Eight test objects in the phantom with contrast levels ranging from 13 to 1710 HU were used to assess spatial resolution. The axial spatial resolution was quantified with the point spread function (PSF), while the z resolution was quantified with the slice sensitivity profile. Both were measured locally on the test objects and in the image domain. The dependence of spatial resolution on contrast and dose levels was studied. The study also features a systematic investigation of the potential trade-off between spatial resolution and locally defined noise and their joint impact on the overall image quality, which was quantified by the image domain-based channelized Hotelling observer (CHO) detectability index d′. Results: (1) The axial spatial resolution of MBIR depends on both radiation dose level and image contrast level, whereas it is supposedly independent of these two factors in FBP. The axial spatial resolution of MBIR always improved with an increasing radiation dose level and/or contrast level. (2) The axial spatial resolution of MBIR became equivalent to that of FBP at some transitional contrast level, above which MBIR demonstrated superior spatial resolution than FBP (and vice versa); the value of this transitional contrast highly depended on the dose level. (3) The PSFs of MBIR could be approximated as Gaussian functions with reasonably good accuracy. (4) Thez resolution of MBIR showed similar contrast and dose dependence. (5) Noise standard deviation assessed on the edges of objects demonstrated a trade-off with spatial resolution in MBIR. (5) When both spatial resolution and image noise were considered using the CHO analysis, MBIR led to significant improvement in the overall CT image quality for both high and low contrast detection tasks at both standard and low dose levels. Conclusions: Due to the intrinsic nonlinearity of the MBIR method, many well-known CT spatial resolution and noise properties have been modified. In particular, dose dependence and contrast dependence have been introduced to the spatial resolution of CT images by MBIR. The method has also introduced some novel noise-resolution trade-off not seen in traditional CT images. While the benefits of MBIR regarding the overall image quality, as demonstrated in this work, are significant, the optimal use of this method in clinical practice demands a thorough understanding of its unique physical characteristics.

60 APPLIED LIFE SCIENCES↗

SU-E-E-12: Validation of the Implementation of Different CT Scanners in Proton Treatment Planning

Purpose: To quantify the impact of the relationship of CT number and Relative Stopping Power (RSP) among different CT-scanners in the evaluation of dose distribution, for different tumor sites and proton therapy modalities like Pencil Beam and Uniform Scanning. Methods: The same tissue characterization phantom was used to analyze the difference in the X-rays energy spectra of 2 CT scanners of the same vendor. One CT is for planning and the other for treatment verification. The Hounsfield unit (HU) variations and associated dosimetric uncertainty were investigated in uniform scanning and pencil beam treatment plans of different sites. At the same time comparisons of the CT calibration curve were done using the same acquisition protocols. The phantom was imaged on a 16 multi-row CT scanner, with energies of 120 and 140 kVp,currents of 263 and 245 mA and slice thickness of 2 and 3mm respectively. The dosimetric uncertainty of the plans was evaluated in a homogeneus phantom comparing DVHs, gamma index criteria 3% 3mm, and range between them. Results: The variation of HU was within the standard deviation of the average for each tissue substitute. The curves fitted with a bilinear interpolation show a maximum deviation in high density materials like cortical bone and solid water, where the HU values deviated more than 0,6% for the 120kVp protocol. For the others curves the deviation was more than 2% for low densities materials. The gamma index uncertainty criteria passed in all the cases. Conclusion: The HU variations for the different scanners were ≤3%. Lower than the 3,5% uncertainties considered in our treatment planning system. The dosimetric analysis shows that the X-ray spectrum has a small effect on the HU-RSP curve, allowing the use of a single tissue characterization curve in our proton treatment planning system for plans verifications.

60 APPLIED LIFE SCIENCES↗

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗