Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Improving the Accuracy of Predicting Maximal Oxygen Consumption (VO2pk)

Maximal oxygen (VO2pk) is the maximum amount of oxygen that the body can use during intense exercise and is used for benchmarking endurance exercise capacity. The most accurate method to determineVO2pk requires continuous measurements of ventilation and gas exchange during an exercise test to maximal effort, which necessitates expensive equipment, a trained staff, and time to set-up the equipment. For astronauts, accurate VO2pk measures are important to assess mission critical task performance capabilities and to prescribe exercise intensities to optimize performance. Currently, astronauts perform submaximal exercise tests during flight to predict VO2pk; however, while submaximal VO2pk prediction equations provide reliable estimates of mean VO2pk for populations, they can be unacceptably inaccurate for a given individual. The error in current predictions and logistical limitations of measuring VO2pk, particularly during spaceflight, highlights the need for improved estimation methods.

Downs, Meghan E.↗

Porous Plug Phase Separator and Superfluid Film Flow Suppression System for the Soft X-Ray Spectrometer Onboard Hitomi

When using superfluid helium in low gravity environments, porous plug phase separators are commonly used to vent boiloff gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ~ 30 ug/s, equivalent to ~ 0.7 mW heat load. It is therefore critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 ug/s, corresponding to a loss of cooling capacity of <40 uW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. In this paper, design, on-ground testing results and in-orbit performance are described.

Porous↗

Economic Feasibility Analysis and Engineering System Design Development of Novel Cesium Adsorbents - 18680

Potassium copper hexacyanoferrate-cellulose hydrogel composites (HCF-gels) and potassium copper hexacyanoferrate-embedded poly-citric acid hydrogel film (HPC) were synthesized. In Cs{sup +} removal experiments, HCF-gels exhibited exceptional Cs{sup +} adsorption capacities 2.06-2.32 mmol g{sup -1}. HPC showed a very high Cs{sup +} uptake of 667 mg/g KCuHCF. The adsorbents revealed stable and high Cs{sup +} removal efficiency across a wide pH range. Notably, the adsorbents could adsorb Cs{sup +} selectively in seawater containing Cs{sup +}. The combination of testing and radiation stability results indicated that the performance of the materials are maintained whether irradiated or not. The cost of the HCF-gels and HPC were estimated approximately 13.0055 $/kg and 38.2490 $/kg respectively. This is reasonable cost compared to commercialized Cs{sup +} adsorbents. New pool scrubbing system is designed for engineering system design to apply novel Cs{sup +} adsorbents under severe accident condition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of Deposition Behavior of Supersaturated Silicic Acid around Geological Disposal Facility - 19137

For safety evaluation about the geological disposal system, the leakage of radionuclides with groundwater flow is estimated by considering the groundwater flow through the manmade and natural barriers. In such an estimate, we should also consider the influence of cement materials used for the construction of the disposal facility system. Cement material including high alkalinity alters groundwater condition up to 13 in pH and dissolves numerous silicate materials, which release silicic acid to groundwater. Since this groundwater mixes with natural groundwater downstream, supersaturated silicic acid will be produced with the decrease of pH to 8 around the repository system. Thus, in this study, the behavior of supersaturated silicic acid in a flow system was examined by using the column packed with amorphous silica particles under the condition of constant hydraulic head. The packed length is 20 mm or 40 mm, and the supersaturated silicic acid solution was continuously injected into the column. Here, the supersaturated silicic acid was adjusted by mixing with distilled water of pH 8 just before the solution was injected into the column. In the results, the supersaturated silicic acid quickly deposited in the packed column, and colloidal silicic acid was not detected at the outlet of the column. The deposition amount of supersaturated silicic acid in the column decreased with time, and became larger in the longer column. Besides, the flow rate decreased with the deposition of supersaturated silicic acid. Thus, this study monitored the decrease rate of permeability with the supply amount of silicic acid. In the results, the change rate did not depend on packed length. This suggested that even with a short packed length, by considering the amount of precipitation of supersaturated silicic acid, it is possible to estimate the change in permeability similarly to the case of a long packed length. Such a decrease effect in permeability may contribute to retarding the migration of radionuclides around the repository. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Development of a Testing Protocol for C7 Carbon Fiber Core Conductors

To avoid the high costs and environmental and regulatory challenges of building new lines to meet the power demand, utilities are searching for ways to increase power transmission capacity on existing lines and thereby. This could involve upgrading the network lines with conductors capable of transmitting greater capacity. In recent years, conductor manufacturers have begun producing new conductors that can operate at higher temperatures without violating present electrical clearances to ground and other objects. One new conductor technology is a carbon composite core with PPS polymer matrix and PEEK capping layer composite conductor, manufactured by Southwire Inc. The conductor uses new materials, which have not previously been used for overhead lines. The project made an initial characterization of the composite core to define the material used in the manufacture of the composite. Several analytical procedures were then conducted to evaluate the physical-chemical impacts on the composite as a result of thermal exposure. These procedures included thermogravimetry, dynamic mechanical analysis, thermal mechanical analyses, and optical microscopy. Mechanical three-point flexural tests, tensile tests, creep tests, and dynamic vibration tests were then performed to estimate the potential degradation after thermal aging. The report provides the basis to develop a qualification testing protocol for the carbon composite core at targeted service environments. The work covers the design of the qualification testing protocol and the follow-on validation testing to support the proposed methods. The research includes the following approaches: initial characterization, performance of thermal aging, characterization of the aged material, comparison of aged properties or characteristics to the original, and concluding by the findings through the developed qualification procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Present-day and future Antarctic ice sheet climate and surface mass balance in the Community Earth System Model

Here, we present climate and surface mass balance (SMB) of the Antarctic ice sheet (AIS) as simulated by the global, coupled ocean–atmosphere–land Community Earth System Model (CESM) with a horizontal resolution of ~1° in the past, present and future (1850–2100). CESM correctly simulates present-day Antarctic sea ice extent, large-scale atmospheric circulation and near-surface climate, but fails to simulate the recent expansion of Antarctic sea ice. The present-day Antarctic ice sheet SMB equals 2280 ± 131Gtyear –1 , which concurs with existing independent estimates of AIS SMB. When forced by two CMIP5 climate change scenarios (high mitigation scenario RCP2.6 and high-emission scenario RCP8.5), CESM projects an increase of Antarctic ice sheet SMB of about 70 Gtyear –1 per degree warming. This increase is driven by enhanced snowfall, which is partially counteracted by more surface melt and runoff along the ice sheet’s edges. This intensifying hydrological cycle is predominantly driven by atmospheric warming, which increases (1) the moisture-carrying capacity of the atmosphere, (2) oceanic source region evaporation, and (3) summer AIS cloud liquid water content.

54 ENVIRONMENTAL SCIENCES↗

First storage of ion beams in the Double Electrostatic Ion-Ring Experiment: DESIREE

We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (C{sub n}{sup -}, n= 1, 2, 3, 4) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For 10 keV C{sub 2}{sup -} molecular anions we measure the residual-gas limited beam storage lifetime to be 448 s {+-} 18 s with two independent detector systems. Using the measured storage lifetimes we estimate that the residual gas pressure is in the 10{sup -14} mbar range. When high current ion beams are injected, the number of stored particles does not follow a single exponential decay law as would be expected for stored particles lost solely due to electron detachment in collision with the residual-gas. Instead, we observe a faster initial decay rate, which we ascribe to the effect of the space charge of the ion beam on the storage capacity.

43 PARTICLE ACCELERATORS↗

Structural transformation of macroporous silicon anodes as a result of cyclic lithiation processes

Anodes based on a regular lattice of macroporous silicon with different periods, sizes, and shapes of pore cross sections are studied. The discharge capacity and its degradation during cycling (embedding and extraction of lithium) are examined. Scanning electron microscopy is used to analyze changes in the electrode structure upon the lithiation/delithiation of Si and to evaluate the elemental composition of the porous material. An ex situ morphological analysis of the electrodes demonstrates that, on the whole, the porous structure is preserved upon cycling and the thickness of silicon walls increases. The degree of Si-wall destruction depends on their initial thickness. Estimates show that the electrolyte reduction process mainly occurs according to the two-electron mechanism, with inorganic salts of lithium formed as a result.

36 MATERIALS SCIENCE↗

A Novel Continuous Ultrasound-Assisted Leaching Process for Rare Earth Element Extraction: Environmental and Economic Assessment

Rare earth elements (REEs) make up integral components in personal electronics, healthcare instrumentation, and modern energy technologies. REE leaching with organic acids is an environmentally friendly alternative to traditional extraction methods. Our previous study demonstrated that batch ultrasound-assisted organic acid leaching of REEs can significantly decrease environmental impacts compared to traditional bioleaching. The batch method is limited to small volumes and is unsuitable for industrial implementation. This study proposes a novel approach to increase reaction volume using a continuous ultrasound-assisted organic acid leaching method. Laboratory experiments showed that continuous ultrasound-assisted leaching increased the leaching rate (µg/h) 11.3–24.5 times compared to our previously reported batch method. Techno-economic analysis estimates the cost of the continuous approach using commercially purchased organic acids is $\$$9465/kg of extracted REEs and $\$$4325/kg of extracted REEs, using gluconic acid and citric acid, respectively. The sensitivity analysis reveals that substituting commercially purchased organic acids with microbially produced biolixiviant can reduce the process cost by approximately 99% while minimally increasing energy consumption. Environmental assessment shows that most of the emissions stemmed from the energy required to power the ultrasound reactor. We concluded that increased leaching capacity using a continuous ultrasound-assisted approach is feasible, but process modifications are needed to reduce the environmental impact.

54 - ENVIRONMENTAL SCIENCES/GLOBAL CLIMATE CHANGE ↗

Melting of iron by significant structure theory

From Eyring's method of significant structures, a partition function is derived for liquid iron. The solid at high temperature is described in the Einstein approximation. Magnetic and electronic contributions to the thermodynamic properties of both the liquid and solid phases are considered. The model is compatible with properties (thermal expansion, compressibility, heat capacity, entropy of melting, and volume change on melting) at one atm. The melting temperature at high pressure is found by satisfying the requirement that the Gibbs free energies of the liquid and solid phases are equal at the melting temperature. Under conditions at the earth's core-mantle boundary, the melting temperature of iron is greater than approximately 5000 K, and under inner-outer core conditions the melting temperature is greater than approximately 7000 K. These estimates are consistent with the Lindemann melting law, but not with the Kraut-Kennedy melting law.

Leppaluoto, D. A.↗

Influence of Ductility on the Performance of Lunar Habitat Structures Under Recurrent Disturbances

This research examines how ductility affects the durability of lunar surface structures against recurring disturbances like moonquakes, micrometeorite impacts, and thermal cycles over an extended period. The structural performance at various levels of ductility was determined by adjusting material parameters and the thickness of a reference multilayered dome structure. Moonquake and micrometeorite impact-induced lateral displacements were estimated using a reduced-order model under a control-oriented dynamic computational modeling framework. The study considered the degradation of the metallic dome’s strength properties over time due to thermal cycles. Fragility curves were generated by assessing the likelihood of reaching three predefined damage levels as a result of multiple hazards. Additionally, a discounted cash flow analysis was conducted to incorporate a financial aspect into the performance comparison. The findings revealed that structures with sufficient ductility capacity have a lower probability of sustaining severe damage or collapsing within a shorter time frame. Hence, having ductile structures in lunar environments is advantageous as it allows the postponement of maintenance and repair actions, thereby conserving scarce resources for more urgent tasks. Moreover, the financial analysis demonstrated that lunar habitats with higher ductile capacities result in larger net present values, offering a higher return on the initial investment.

Arsalan Majlesi↗

System impacts of accelerated transfer of used nuclear fuel to dry storage - 15220

In the wake of the September 11, 2001 terror attacks, and again after the March 11, 2011, accident at the Fukushima Dai-Ichi station from the Great East Japan Earthquake/tsunami, concern was expressed regarding security of current spent fuel storage practices in the United States. An approach recurrently proposed to reduce the potential for fire and the release of radionuclides in an accident or sabotage scenario is to reduce the loading of the reactor fuel pools, which are frequently maintained near their full capacity at many reactor sites in the U.S. We assess the impact on the waste management system of different scenarios for accelerating the schedule of used nuclear fuel (UNF) transfer from reactor pools to dry storage casks. We consider scenarios where the spent fuel pools are drawn down to 50% or 25% of full capacity over 5- or 10-year schedules. The scenarios include status quo, where UNF continues to remain in dry storage at the reactor sites, as well as scenarios with UNF transfer to interim storage and eventually to a mined geologic repository. The primary purpose is to evaluate how the different scenarios for accelerating the transfer of UNF to at-reactor dry storage would affect the performance of the entire UNF management system. Areas that were considered include an estimate of the additional system costs that could be incurred and where the existing infrastructure at the reactor sites would come under stress from the transfer demands. This study considered only the fuel-handling logistics and rough-order-of-magnitude cost at reactor sites, interim storage facility, and operations to package UNF into disposal canisters. The effects of minimum fuel age that could be transferred and the accelerated transfer starting date are also examined, but found to have relatively little effect. Impacts on safety and worker dose are not evaluated quantitatively, although effects can be inferred from increases in handling operations, etc. from the scenarios considered. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Development of an Unmanned Mobile Current Turbine Platform: Preprint

The design and development of a prototype unmanned mobile floating platform, equipped with a custom low-flow marine current turbine for autonomously seeking and harnessing tidal/coastal currents is described. The platform is an unmanned surface vehicle in the form of a catamaran with two electric outboard motors and capabilities for autonomous navigation. An undershot water wheel, aided by a custom flow concentrator, has been selected as the basic design for the marine current turbine, which is mounted on the stern of the unmanned surface vehicle platform. The concept of operation is that the platform would navigate to a designated marine current resource, autonomously anchor at the location, align itself in the current and deploy the current turbine using a custom cable-lift deployment mechanism. As the turbine harnesses the local current, an onboard power-take-off device converts the harnessed mechanical energy to electricity which is stored in onboard batteries. Considerations of deployment in tidal and coastal waters required obtaining the necessary environmental permits for conducting in-water testing; developing required mitigation measures in protecting local wildlife and their habitats; and identifying potential in-water test sites and surveying them for their suitability in terms of the current resource, bottom type, water depth, and local boat traffic. The design and development of the turbine and the results of initial in-water testing are discussed. The potential for scaling up the system for extended capacity is presented.

ENGINEERING,TIDAL AND WAVE POWER↗

Assessing the effects of seawater temperature and pH on the bioaccumulation of emerging chemical contaminants in marine bivalves

Highlights: • Temperature and pH effects on emerging contaminants' bioaccumulation were assessed. • Increased temperature promoted the bioaccumulation of Dec 602, Dec 604 and TBBPA. • Lower pH increased Dec's bioaccumulation, but also iAs and PFCs' elimination. • Human exposure to some compounds may increase with climate change. Emerging chemical contaminants [e.g. toxic metals speciation, flame retardants (FRs) and perfluorinated compounds (PFCs), among others], that have not been historically recognized as pollutants nor their toxicological hazards, are increasingly more present in the marine environment. Furthermore, the effects of environmental conditions (e.g. temperature and pH) on bioaccumulation and elimination mechanisms of these emerging contaminants in marine biota have been poorly studied until now. In this context, the aim of this study was to assess, for the first time, the effect of warmer seawater temperatures (Δ = + 4 °C) and lower pH levels (Δ = − 0.4 pH units), acting alone or combined, on the bioaccumulation and elimination of emerging FRs (dechloranes 602, 603 and 604, and TBBPA), inorganic arsenic (iAs), and PFCs (PFOA and PFOS) in two estuarine bivalve species (Mytilus galloprovincialis and Ruditapes philippinarum). Overall, results showed that warming alone or combined with acidification promoted the bioaccumulation of some compounds (i.e. dechloranes 602, 604, TBBPA), but also facilitated the elimination of others (i.e. iAs, TBBPA). Similarly, lower pH also resulted in higher levels of dechloranes, as well as enhanced iAs, PFOA and PFOS elimination. Data also suggests that, when both abiotic stressors are combined, bivalves' capacity to accumulate contaminants may be time-dependent, considering significantly drastic increase observed with Dec 602 and TBBPA, during the last 10 days of exposure, when compared to reference conditions. Such changes in contaminants' bioaccumulation/elimination patterns also suggest a potential increase of human health risks of some compounds, if the climate continues changing as forecasted. Therefore, this first study pointed out the urgent need for further research on the effects of abiotic conditions on emerging contaminants kinetics, to adequately estimate the potential toxicological hazards associated to these compounds and develop recommendations/regulations for their presence in seafood, considering the prevailing environmental conditions expected in tomorrow's ocean.

54 ENVIRONMENTAL SCIENCES↗

Optimizing the Orientation of Solar Photovoltaic Systems Considering the Effects of Irradiation and Cell Temperature Models with Dust Accumulation

To cope with the growing installation capacities of solar photovoltaic (PV) systems in desert areas, it is necessary to revisit the energy production models and the optimal angles of PV panels given the significant impacts of ambient temperature, wind speed, dust accumulation, and cleaning frequency. In this study, these four factors are examined for four PV technologies (polycrystalline, microcrystalline, monocrystalline, and thin-film) at three cities in Jordan, Egypt, and Tunisia using precise ground-level meteo-solar measurements. Different models are compared to estimate the diffuse irradiance, as well as account for the effects of operating temperature, wind speed, and dust accumulation on energy production and optimal tilt and azimuth angles of the panels. The results reveal 1.5 % higher energy production estimates using the isotropic model, compared to the anisotropic model in the summer months. Considering the cooling effect of wind speed decreases the operating cell temperature drops by up to 7.05 % for thin film panels. The annually produced energy decreases by 24 % when the panels are cleaned bi-monthly. When the dust accumulation rate doubles, the energy production decreases by ~10 % for all studied cases. Also, the variations in optimal tilt and azimuth angles with dust accumulation rate are within ~3.0 degrees .

14 SOLAR ENERGY↗

Understanding the Nature of Capacity Decay and Interface Properties in Li//LiNi 0.5 Mn 1.5 O 4 Cells by Cycling Aging and Titration Techniques

The spinel structure LiNi 0.5 Mn 1.5 O 4 (LNMO) is a propitious cathode material for next-generation lithium-ion batteries for fast charge–discharge applications, but its capacity decay mechanism and rate-limiting process are not yet well understood. In this work, electrochemical impedance spectroscopy (EIS) with galvanostatic intermittent titration (GITT) and cycling aging techniques were employed to investigate the nature of capacity decay in disordered-phase LNMO. Different resistive components were separated after every 10 cycles. Cell overvoltages (ΔVs) due to ohmic conduction, charge transfer (CT), and concentration polarization (CP) were individually determined. Results revealed that the cell exhibited a higher ΔV at a higher discharged state. However, the ΔV value for CP was higher at a higher state of charge (SOC), and the overall LNMO/electrolyte interface played a major role in the rate-determining step. Battery life was estimated based on the results. Battery calendar life was found to be more vulnerable than cycle life. Furthermore, results also indicated that the working SOC range could be optimized based on the resistance analysis by avoiding those SOCs that have the most detrimental impact (e.g., heat generation and fire hazard).

25 ENERGY STORAGE↗