Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Particle in cell simulations of fast magnetosonic wave turbulence in the ion cyclotron frequency range

Fully electromagnetic particle in cell simulations of nonlinear waves propagation and interaction are performed in two-dimensional plane geometry in magnetized plasma in ion cyclotron frequency range. A spectrum of fast magnetosonic wave modes with wave numbers parallel and perpendicular to the uniform equilibrium magnetic field is launched into plasma and the nonlinear dynamics of these waves is analyzed. Results show that the wave magnetic energy spectrum cascades to smaller scales. In the low frequency in the magnetohydrodynamic regime, the cascade is basically isotropic. Once entering the high frequency kinetic regime the cascade exhibits strong anisotropy, it extends to much smaller scales in direction perpendicular to the equilibrium magnetic field. The shape of the cascade is established after a few ion cyclotron periods and most of the energy in the cascade stays in the fast wave oscillations. Collisionless damping on electrons is the main dissipation channel in these results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parallel Configuration For Fast Superconducting Strip Line Detectors With Very Large Area In Time Of Flight Mass Spectrometry

We realized a very fast and large Superconducting Strip Line Detector based on a parallel configuration of nanowires. The detector with size 200x200 {mu}m{sup 2} recorded a sub-nanosecond pulse width of 700 ps in FWHM (400 ps rise time and 530 ps relaxation time) for lysozyme monomers/multimers molecules accelerated at 175 keV in a Time of Flight Mass Spectrometer. This record is the best in the class of superconducting detectors and comparable with the fastest NbN superconducting single photon detector of 10x10 {mu}m{sup 2}. We succeeded in acquiring mass spectra as the first step for a scale-up to {approx}mm pixel size for high throughput MS analysis, while keeping a fast response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of reactive high-power impulse magnetron sputtering discharge studied by time- and space-resolved optical emission spectroscopy and fast imaging

Time- and space-resolved optical emission spectroscopy and fast imaging were used for the investigation of the plasma dynamics of high-power impulse magnetron sputtering discharges. 200 {mu}s pulses with a 50 Hz repetition frequency were applied to a Cr target in Ar, N{sub 2}, and N{sub 2}/Ar mixtures and in a pressure range from 0.7 to 2.66 Pa. The power density peaked at 2.2-6 kW cm{sup -2}. Evidence of dominating self-sputtering was found for all investigated conditions. Up to four different discharge phases within each pulse were identified: (i) the ignition phase, (ii) the high-current metal-dominated phase, (iii) the transient phase, and (iv) the low-current gas-dominated phase. The emission of working gas excited by fast electrons penetrating the space in-between the electrodes during the ignition phase spread far outwards from the target at a speed of 24 km s{sup -1} in 1.3 Pa of Ar and at 7.5 km s{sup -1} in 1.3 Pa of N{sub 2}. The dense metal plasma created next to the target propagated in the reactor at a speed ranging from 0.7 to 3.5 km s{sup -1}, depending on the working gas composition and the pressure. In fact, it increased with higher N{sub 2} concentration and lower pressure. The form of the propagating plasma wave changed from a hemispherical shape in Ar, to a droplike shape extending far from the target in N{sub 2}. An important N{sub 2} emission rise in the latter case was detected during the transition at the end of the metal-dominated phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Present status and future prospect of Fast Ignition Realization Experiment (FIREX) Project at ILE, Osaka

Thermonuclear ignition and subsequent burn are key physics for achieving laser fusion. In fast ignition, a highly compressed fusion fuel generated with multiple ns-laser beams is rapidly heated with a large energy, ps-laser pulse in prior to core disassembly. This scheme has a high potential to achieve ignition and burn since driver energy required for high fusion gain is predicted to be about one tenth of that needed for the central ignition scheme. In Japan, Fast Ignition Realization Experiment (FIREX) project has been started to clarify the physics of energy transport and deposition in the core plasma and to demonstrate fuel temperature of above 5 keV. After the success, FIREX-I will be followed by the second phase of the project (FIREX-II) to demonstrate ignition and burn. LFEX laser, designed to deliver a laser pulse of 10 kJ in 10 ps, are operational and the first phase of FIREX experiments has been stated. A new target is proposed to attain dense compression of fuel and improve laser-core coupling efficiency by adopting double-cone structure, a low-density inner liner, low-Z outer coating, and Br-doped fuel shell. In this paper, present status and near term prospects of the FIREX-I project will be reported together with activities on target designing, laser development, and plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast integrator based data acquisition system for the SST-1 Thomson scattering system

An operational transconductance amplifier based fast charge-integrating module (FCIM) is designed and developed for an easy acquisition of fast Thomson scattered and background signal. FCIM based data acquisition technique can be used for the measurement of charge pulses of <20 ns duration. The response of the module is tested using a standard pulsed charge-generating module. The measuring charge range of the module depends on the integrating capacitor. Comparison of the performance of FCIM to commercially available module shows that it has better dynamic range with higher sensitivity and less measurement error. The module is quite cost effective and has many new features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of fast nanoparticles in the solar wind

Dust grains in the nanometer range bridge the gap between atoms and larger grains made of bulk material. Their small size embodies them with special properties. Due to their high relative surface area, they have a high charge-to-mass ratio, so that the Lorentz force in the solar wind magnetic field exceeds the gravitational force and other forces by a large amount, and they are accelerated to a speed of the order of magnitude of the solar wind speed. When such fast nanoparticles impact a spacecraft, they produce craters whose matter vaporises and ionises, yielding transient voltages as high as do much larger grains of smaller speed. These properties are at the origin of their recent detection at 1 AU in the solar wind. We discuss the detection of fast nanoparticles by wave instruments of different configurations, with applications to the recent detections on STEREO/WAVES and CASSINI/RPWS. Finally we discuss the opportunities for nanoparticle detection by wave instruments on future missions and/or projects in the inner heliosphere such as Bepi-Colombo and Solar Orbiter.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast Tomography: A Study Of Image Quality

We present tomographic slices of fast X-ray computed microtomography, focusing on one hand on the comparison of scans with identical scan time but varying experimental settings, on the other hand on comparing scans with total scan times that are two orders of magnitude apart. We show that streaks in the Fourier-space of the transformed images appear when the number of projections is reduced. These streaks exhibit spacing by the same angle as the one that is covered by the sample during the exposure time of one projection. Further a method for the estimation of information loss in fast scans is presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplification of a fast wave by extracting both the kinetic energy and electrostatic potential energy of a large-orbit relativistic electron beam in a coaxial electrostatic wiggler

Nonlinear model and simulation technique of the interaction and energy transfer between a fast wave and a large-orbit relativistic electron beam in a coaxial electrostatic wiggler are presented. Unlike the situations in a magnetostatic-wiggler free-electron laser (MWFEL) and in an electron cyclotron maser (ECM), the electrostatic potential of the electrons plays an important role and participates in the energy exchange between the wave and the electron beam. Compared to MWFEL and ECM, the coaxial electrostatic-wiggler configuration has a distinguishing peculiarity that besides the electron-beam's kinetic energy, its electrostatic potential energy can be effectively transferred to the fast wave. Simulation shows that wave could be amplified with ultrahigh gain by extracting both the kinetic energy and electrostatic potential energy of the electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport study of intense-laser-produced fast electrons in solid targets with a preplasma created by a long pulse laser

The effect of preplasma on fast electron generation and transport has been studied using an intense-laser pulse (I=2x10{sup 18} W/cm{sup 2}) at the Osaka University. An external long pulse laser beam (E<1.5 J) was used to create various levels of preplasmas in front of a planar target for a systematic study. Kalpha x-ray emission from a fluorescence layer (copper) was absolutely counted and its spatial distribution was monitored. Experimental data show Kalpha x-ray signal reduction (up to 60%) with an increase in the preplasma level. In addition, a ring structure of Kalpha x rays was observed with a large preplasma. The underlying physics of the ring structure production was studied by integrating the modeling using a radiation hydrodynamics code and a hybrid particle-in-cell code. Modeling shows that the ring structure is due to the thermoelectric magnetic field excited by the long pulse laser irradiation and an electrostatic field due to the fast electrons in the preplasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Beamline for Fast Polarization Switching at NSLS-II

The first XUV beamline (200-2000 eV) at NSLS-II will have two branches, one optimized for photon hungry experiments requiring high coherent flux and one optimized for studies of polarization sensitive materials and interfaces based on fast polarization switching. We describe here the branch designed for fast polarization switching with frequencies up to 1 kHz, high photon flux, and good energy resolution. The beamline will be served by two canted undulators and is based on the focusing variable line spacing grating monochromator. The two beams will be focused at the same spot of approximately 80x10 {mu}m (hor.xver.). The expected circular polarized flux at the sample from each device up to 1.4 keV will be higher than 10{sup 12} photons/s at a resolving power better than 10{sup 4}. An additional KB focusing system will deliver the two beams to a spot in the {mu}m range.

43 PARTICLE ACCELERATORS↗

500-MHz x-ray counting with a Si-APD and a fast-pulse processing system

We introduce a counting system of up to 500 MHz for synchrotron x-ray high-rate measurements. A silicon avalanche photodiode detector was used in the counting system. The fast-pulse circuit of the amplifier was designed with hybrid ICs to prepare an ASIC system for a large-scale pixel array detector in near future. The fast amplifier consists of two cascading emitter-followers using 10-GHz band transistors. A count-rate of 3.25x10{sup 8} s{sup -1} was then achieved using the system for 8-keV x-rays. However, a baseline shift by adopting AC-coupling in the amplifier disturbed us to observe the maximum count of 4.49x10{sup 8} s{sup -1}, determined by electron-bunch filling into a ring accelerator. We also report that an amplifier with a baseline restorer was tested in order to keep the baseline level to be 0 V even at high input rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray continuum radiation transmitted through metallic filters: An analytical approach to fast electron temperature measurements

A new set of analytic formulas describes the transmission of soft x-ray continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler et al., Rev. Sci. Instrum. 70, 599 (1999)]. The new analytic formulas can improve the interpretation of the experimental results and thus contribute in obtaining fast temperature measurements in between intermittent Thomson scattering data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the response of a fast ion loss detector using orbit tracing techniques in a neutral beam prompt-loss study on the DIII-D tokamak

A numerical model describing the expected measurements of neutral beam prompt-losses by a newly commissioned fast ion loss detector (FILD) in DIII-D is presented. This model incorporates the well understood neutral beam deposition profiles from all eight DIII-D beamlines to construct a prompt-loss source distribution. The full range of detectable ion orbit phase space available to the FILD is used to calculate ion trajectories that overlap with neutral beam injection footprints. Weight functions are applied to account for the level of overlap between these detectable orbits and the spatial and velocity (pitch) properties of ionized beam neutrals. An experimental comparison is performed by firing each neutral beam individually in the presence of a ramping plasma current. Fast ion losses determined from the model are in agreement with measured losses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scintillator-based diagnostic for fast ion loss measurements on DIII-D

A new scintillator-based fast ion loss detector has been installed on DIII-D with the time response (>100 kHz) needed to study energetic ion losses induced by Alfven eigenmodes and other MHD instabilities. Based on the design used on ASDEX Upgrade, the diagnostic measures the pitch angle and gyroradius of ion losses based on the position of the ions striking the two-dimensional scintillator. For fast time response measurements, a beam splitter and fiberoptics couple a portion of the scintillator light to a photomultiplier. Reverse orbit following techniques trace the lost ions to their possible origin within the plasma. Initial DIII-D results showing prompt losses and energetic ion loss due to MHD instabilities are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast and slow magnetosonic waves in two-dimensional spin-1/2 quantum plasma

Using the spin-1/2 resistive quantum magnetohydrodynamics model, linear and nonlinear relations for slow and fast magnetosonic modes are derived. Spin effects are incorporated via spin force and macroscopic spin magnetization current. The plasma resistivity is shown to play a role of dissipation in the system. With the aid of tanh method the traveling wave solution of Kadomstev-Petviashvili-Burgers is obtained. The solution shows a general shock wave profile superposed by a perturbative solitary-wave contribution. The dynamics of fast and slow magnetosonic shock and soliton, respectively, in the presence and absence of dissipation is investigated with respect to electron spin magnetization, quantum diffraction, and plasma statistic. It is found that results obtained from the spin quantum plasmas differ significantly from the nonspin quantum plasmas. The relevance of the present work to dense astrophysical plasmas such as pulsar magnetosphere is pointed out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The response of a fast phosphor screen scintillator (ZnO:Ga) to low energy ions (0-60 keV)

ZnO:Ga is a promising, high time resolution candidate for use as a fast-ion-loss detector in TJ-II. We compare its ionoluminescence with that of the standard fast-ion-loss detector material, SrGa{sub 2}S{sub 4}:Eu (also known as TG-Green), when irradiated by H{sup +} ions with a range of energies E{<=}60 keV using a dedicated laboratory setup. It is found that ZnO:Ga is a reasonably good candidate for detecting low energy (E<60 keV) ions as it has excellent time resolution; however, its sensitivity is about 100 times lower than TG-Green, potentially limiting it to applications with high energy ion loss signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time and space resolved interferometry for laser-generated fast electron measurements

A technique developed to measure in time and space the dynamics of the electron populations resulting from the irradiation of thin solids by ultraintense lasers is presented. It is a phase reflectometry technique that uses an optical probe beam reflecting off the target rear surface. The phase of the probe beam is sensitive to both laser-produced fast electrons of low-density streaming into vacuum and warm solid density electrons that are heated by the fast electrons. A time and space resolved interferometer allows to recover the phase of the probe beam sampling the target. The entire diagnostic is computationally modeled by calculating the probe beam phase when propagating through plasma density profiles originating from numerical calculations of plasma expansion. Matching the modeling to the experimental measurements allows retrieving the initial electron density and temperature of both populations locally at the target surface with very high temporal and spatial resolution ({approx}4 ps,6 {mu}m). Limitations and approximations of the diagnostic are discussed and analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast ion charge exchange spectroscopy adapted for tangential viewing geometry in LHD

A tangential Fast Ion Charge eXchange Spectroscopy is newly applied on a Large Helical Device (LHD) for co/countercirculating fast ions, which are produced by high energy tangential negative-ion based neutral beam injection. With this new observation geometry, both the tangential-neutral beam (NB) and a low-energy radial-NB based on positive ions can be utilized as probe beams of the measurement. We have successfully observed Doppler-shifted H-alpha lights due to the charge exchange process between the probing NB and circulating hydrogen ions of around 100 keV in LHD plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗