Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,637 records · Page 91

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

Quantum-Classical Science for the Plasma-Material Interface in NSTXU (Final Technical Report)

Plasma facing surfaces (PFS) have a profound influence on plasma performance and choice of material for PFSs is a burning issue for tokamak reactors. Using lithium wall conditioning in NSTX has resulted in a beneficial influence on plasma behavior including control of hydrogen recycling and improvements in energy confinement, longer confinement times, edge density control, and the elimination of Edge Localized Modes. A major challenge for the NSTX-U (increased power flux, increased campaign time) as well as for other magnetic fusion devices is to extend high-performance plasmas for very long durations, and to integrate this high performance with plasma facing components (PFCs) that can withstand very high heat and particle fluxes while maintaining structural integrity with minimal retention of fusion fuel. This project directly contributed to filling up the knowledge gaps and data for the dynamics of the plasma-facing interfaces in the NSTX-U at nano and nano-to-micro scales. This was achieved by both deciphering the poorly understood nanoscale phenomenology of plasma-surface interactions and providing the connection and comparison with the experiments which provide understanding at the mesoscopic scales. We modelled the dynamic response and evolution of a mixed material surfaces (D, Li, C, B, O) to bombardment by plasma particles, and investigated microstructure changes, erosion, surface chemistry, deuterium implantation and permeation. The main objectives of the project are i) a comparison of Li and B effects when deposited on carbon, and ii) the role of oxygen and other impurities (e.g. carbon, boron) in the lithium performance. In addition to predicting and understanding the phenomenology of the processes, the project achieved deliverables on the i) plasma induced erosion rates of PFCs (outer wall, divertor, etc.), including chemical and physical sputtering yields at various temperatures (300-700K), ii) deuterium uptake/recycling rates, and iii) accurate probability rates for the processes and reactions in i-ii which were used to understand the experimental results of the J.P. Allain and B. Koel NSTX-U projects. Lithium was a distinctive focus of the project. It easily charges in contact with other fusion material atoms, giving partially or fully its external electron cloud to other atoms in its vicinity and polarizing the mixed material. Our research strategy used experimentally validated multiscale theory applied to the large, multicomponent material surface systems. With the use of US supercomputing facilities we simulated evolution of atomic charges, chemistry, retention of deuterium, sputtering and morphology by introducing the corrections to the classical molecular dynamics, like are electronegativity equalization method (EEM) and quantum-classical molecular dynamics (QCMD). The goal was to understand and quantify the dynamics of the creation and evolution of the plasma-material interface under irradiation by atoms and molecules at boronized carbon, lithiated carbon, and boronized-lithiated carbon for both solid and self-healing liquid-metal divertor.

36 MATERIALS SCIENCE↗

The role of Frenkel defect diffusion in dynamic annealing in ion-irradiated Si

The formation of stable radiation damage in crystalline solids often proceeds via complex dynamic annealing processes, involving migration and interaction of ballistically-generated point defects. The dominant dynamic annealing processes, however, remain unknown even for crystalline Si. Here, we use a pulsed ion beam method to study defect dynamics in Si bombarded in the temperature range from -20 to 140 °C with 500 keV Ar ions. Results reveal a defect relaxation time constant of ~10–0.2 ms, which decreases monotonically with increasing temperature. The dynamic annealing rate shows an Arrhenius dependence with two well-defined activation energies of 73 ± 5 meV and 420 ± 10 meV, below and above 60 °C, respectively. Rate theory modeling, bench-marked against this data, suggests a crucial role of both vacancy and interstitial diffusion, with the dynamic annealing rate limited by the migration and interaction of vacancies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine Learning-Driven Reliability Estimation of PV Inverters Considering Alert-Ambient Variability

Weather-induced spatio-temporal degradation limits outdoor PV inverter lifetime and reliability, necessitating advanced data analysis. This study employs a top-down, data-driven approach utilizing multiple machine learning (ML) algorithms to estimate inverter reliability in a 1.4 MW PV power plant, considering factors such as irradiance, humidity, temperature, time of day, and weather conditions. An extensive alert dataset from 17 identical inverters, including alert types, propagation, and frequency, reveals significant correlations with environmental factors and inverter output power, enabling the construction of a performance reliability model. Dual-stage supervised-ML models are evaluated for accuracy, with the ‘classification-regression’ model by an artificial neural network (ANN) tested on the averaged “Alert-Ambient” dataset, which is outperformed by ‘clustering-regression’ models using random forest (RF) and K-Nearest Neighbors (KNN) on individual inverter datasets. K-means clustering applies principal component analysis to reduce dimensions, achieving improved accuracy beyond the 80% achieved by ANN on the averaged dataset. Second-stage regression estimates inverter reliability with a mean square error of 0.0195 on the averaged dataset and as low as 0.002 on individual inverter datasets using RF. Furthermore, these findings highlight the method's suitability for estimating PV inverter output reliability under ambient conditions, essential for digital twin development and related applications.

14 SOLAR ENERGY↗

Cell Type-dependent Gene Transcription Profile in Three Dimensional Human Skin Tissue Model Exposed to Low Doses of Ionizing Radiation: Implications for Medical Exposures

The concern over possible health risks from exposures to low doses of ionizing radiation has been driven largely by the increase in medical exposures, the routine implementation of X-ray backscatter devices for airport security screening, and, most recently, the nuclear incident in Japan. Due to a paucity of direct epidemiological data at very low doses, cancer risk must be estimated from high dose exposure scenarios. However, there is increasing evidence that low and high dose exposures result in different signaling events and may have different mechanisms of cancer induction. We have examined the radiation induced temporal response of an in vitro three dimensional (3D) human skin tissue model using microarray-based transcriptional profiling. Our data shows that exposure to 100 mGy of X-rays is sufficient to affect gene transcription. Cell type specific analysis showed significant changes in gene expression with the levels of > 1400 genes altered in the dermis and > 400 genes regulated in the epidermis. The two cell types rarely exhibited overlapping responses at the mRNA level. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) measurements validated the microarray data in both regulation direction and value. Key pathways identified relate to cell cycle regulation, immune responses, hypoxia, reactive oxygen signaling, and DNA damage repair. We discuss in particular the role of proliferation and emphasizing how the disregulation of cellular signaling in normal tissue may impact progression towards radiation induced secondary diseases.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of calibration curves and energy dependence GafChromic{sup TM} XR-QA2 model based radiochromic film dosimetry system

Purpose: The authors investigated the energy response of XR-QA2 GafChromic{sup TM} film over a broad energy range used in diagnostic radiology examinations. The authors also made an assessment of the most suitable functions for both reference and relative dose measurements. Methods: Pieces of XR-QA2 film were irradiated to nine different values of air kerma in air, following reference calibration of a number of beam qualities ranging in HVLs from 0.16 to 8.25 mm Al, which corresponds to effective energy range from 12.7 keV to 56.3 keV. For each beam quality, the authors tested three functional forms (rational, linear exponential, and power) to assess the most suitable function by fitting the delivered air kerma in air as a function of film response in terms of reflectance change. The authors also introduced and tested a new parameterχ = netΔR·e{sup m} {sup netΔR} that linearizes the inherently nonlinear response of the film. Results: The authors have found that in the energy range investigated, the response of the XR-QA2 based radiochromic film dosimetry system ranges from 0.222 to 0.420 in terms of netΔR at K{sub air}{sup air} = 8 cGy. For beam qualities commonly used in CT scanners (4.03–8.25 mm Al), the variation in film response (netΔR at K{sub air}{sup air} = 8 cGy) amounts to ± 5%, while variation in K{sub air}{sup air} amounts to ± 14%. Conclusions: Results of our investigation revealed that the use of XR-QA2 GafChromic{sup TM} film is accompanied by a rather pronounced energy dependent response for beam qualities used for x-ray based diagnostic imaging purposes. The authors also found that the most appropriate function for the reference radiochromic film dosimetry would be the power function, while for the relative dosimetry one may use the exponential response function that can be easily linearized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dual-Responsive Macromolecular Surfaces with Binary Patterns

The development of nanopatterned interfaces incorporating multiple stimuli-responsive polymers has great potential for advancing smart sensors and molecular capture devices, yet it remains challenging due to limitations in patterning techniques and “grafting from” methods. Here, we present a binary-patterned surface featuring honeycomb-shaped photothermal polypyrrole (PPy) and thermally responsive poly(ethylene glycol methyl ether acrylate-co-poly(ethylene glycol) methyl ether acrylate) [poly(EGMEA-co-PEGMEA)] brushes within the cavities, fabricated using colloidal lithography and surface-initiated photoinduced electron transfer-reversible addition–fragmentation chain transfer (SI-PET-RAFT) polymerization. The morphology of the surface can be precisely tuned by adjusting the height of each domain. This design integrates unique topographical features with the stimuli-responsiveness of the polymer, enabling the collapse of the copolymer brushes through direct heating or photothermal conversion of PPy under near-IR light. In conclusion, this innovative system offers potential capture-release functionality, providing versatility for diverse applications and enhancing adaptability across different functional scenarios.

Copolymers↗

Physical mechanisms of SiN{sub x} layer structuring with ultrafast lasers by direct and confined laser ablation

In the production process of silicon microelectronic devices and high efficiency silicon solar cells, local contact openings in thin dielectric layers are required. Instead of photolithography, these openings can be selectively structured with ultra-short laser pulses by confined laser ablation in a fast and efficient lift off production step. Thereby, the ultrafast laser pulse is transmitted by the dielectric layer and absorbed at the substrate surface leading to a selective layer removal in the nanosecond time domain. Thermal damage in the substrate due to absorption is an unwanted side effect. The aim of this work is to obtain a deeper understanding of the physical laser-material interaction with the goal of finding a damage-free ablation mechanism. For this, thin silicon nitride (SiN{sub x}) layers on planar silicon (Si) wafers are processed with infrared fs-laser pulses. Two ablation types can be distinguished: The known confined ablation at fluences below 300 mJ/cm{sup 2} and a combined partial confined and partial direct ablation at higher fluences. The partial direct ablation process is caused by nonlinear absorption in the SiN{sub x} layer in the center of the applied Gaussian shaped laser pulses. Pump-probe investigations of the central area show ultra-fast reflectivity changes typical for direct laser ablation. Transmission electron microscopy results demonstrate that the Si surface under the remaining SiN{sub x} island is not damaged by the laser ablation process. At optimized process parameters, the method of direct laser ablation could be a good candidate for damage-free selective structuring of dielectric layers on absorbing substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Helium bubble size effects on the surface morphological response of plasma-facing tungsten

Abstract We report a simulation study on the effects of helium (He) bubble size on the morphological evolution and pattern formation on the surface of tungsten used as a plasma-facing component (PFC) in nuclear fusion devices. We have carried out a systematic investigation based on self-consistent dynamical simulations of surface morphological evolution according to an atomistically-informed, 3D continuum-scale model that captures well the relevant length and time scales of surface nanostructure formation in PFC tungsten. The model accounts for PFC surface diffusion, driven by the biaxial compressive stress originating from the over-pressurized He bubbles in the near-surface region of PFC tungsten as a result of He plasma exposure, combined with the formation of self-interstitial atoms in tungsten that diffuse toward the PFC surface and the flux of surface adatoms generated as a result of surface vacancy-adatom pair formation upon He implantation; this transport of surface adatoms contributes to the anisotropic growth of surface nanostructural features due to the different rates of adatom diffusion along and across step edges of islands on the tungsten surface. Our detailed analysis reveals that varying the average He bubble size plays an important role in the PFC surface growth kinetics as well as the resulting surface topography. Specifically, we find that an increase in the He bubble size leads to a deceleration in the growth rate of the tungsten nanotendrils that emanate from the PFC surface. We also find that the separation distance between the resulting surface features increases with increasing He bubble size, as well as over time. This coarsening effect is a thermally activated process resulting in an accurate description of the temperature dependence of the average surface feature separation by an Arrhenius relation.

36 MATERIALS SCIENCE↗

Conceptual magnet design study for fusion nuclear science facility [Magnet design study for fusion nuclear science facility]

The Fusion Nuclear Science Facility (FNSF) is a nuclear confinement device to provide the integrated fusion environment with fusion reactor components. The FNSF is the stepping stone to bridge the technical gaps of burning plasma and nuclear science between the International Thermal Nuclear Experimental Reactor (ITER), currently under construction in the south of France, and the demonstration power plant (DEMO). For the next-step fusion reactors, resistive copper magnet cannot be a sustainable solution due to large power consumption in coils of large size needed. Both Low temperature superconductor (LTS) and high temperature superconductor (HTS) are considered for the FNSF magnet design based on the state-of-the-art fusion superconducting magnet technology. Input parameters to FNSF magnet design include magnetic field of 7.5 T at plasma center with a major radius of 4.8 m and minor radius of 1.2 m, and a peak field of over 16 T on the TF coils. The high magnetic field can be achieved by using the high performance ternary Restack Rod Process (RRP) Nb3Sn strands for toroidal field (TF) magnets and a high aspect ratio rectangular cable-in-conduit conductor (CICC) design. The conductor design concept and TF coil winding pack composition and dimension are discussed based on the horizontal maintenance scheme. Neutron radiation limits for the LTS and HTS conductors and electrical insulation materials are reviewed based on the available materials previously tested. The material radiation limits for FNSF magnets are defined as part of the conceptual design studies. In conclusion, the global structural analysis of FNSF magnets based on the radial build was performed to validate feasibility for the plant layout toward horizontal maintenance and global structural integrity of its magnet system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A protocol for EBT3 radiochromic film dosimetry using reflection scanning

Purpose: To evaluate the performance of the EBT3 radiochromic film dosimetry system using reflection measurements and to suggest a calibration protocol for precise and accurate reflection film dosimetry. Methods: A set of 14 Gafchromic EBT3 film pieces were irradiated to various doses ranging from 0 to 8 Gy and subsequently scanned using both the reflection and transmission mode. Scanning resolution varied from 50 to 508 dpi (0.5–0.05 mm/pixel). Both the red and green color channels of scanned images were used to relate the film response to the dose. A sensitivity, uncertainty, and accuracy analysis was performed for all scanning modes and color channels. The total uncertainty, along with the fitting and experimental uncertainty components, was identified and analyzed. A microscope resolution target was used to evaluate possible resolution losses under reflection scanning. The calibration range was optimized for reflection scanning in the low (<2 Gy) and high (>2 Gy) dose regions based on the reported results. Results: Reflection scanning using the red channel exhibited the highest sensitivity among all modes, being up to 150% higher than transmission mode in the red channel for the lowest dose level. Furthermore, there was no apparent loss in resolution between the two modes. However, higher uncertainties and reduced accuracy were observed for the red channel under reflection mode, especially at dose levels higher than 2 Gy. These uncertainties were mainly attributed to saturation effects which were translated in poor fitting results. By restricting the calibration to the 0–2 Gy dose range, the situation is reversed and the red reflection mode was superior to the transmission mode. For higher doses, the green channel in reflection mode presented comparable results to the red transmission. Conclusions: A two-color reflection scanning protocol can be suggested for EBT3 radiochromic film dosimetry using the red channel for doses less than 2 Gy and the green channel for higher doses. The precision and accuracy are significantly improved in the low dose region following such a protocol.

60 APPLIED LIFE SCIENCES↗

Radiative cooling resource maps for the contiguous United States

Passive cooling devices take advantage of the partially transparent properties of the atmosphere in the longwave spectral band from 8 to 13 μ m (the so-called “atmospheric window”) to reject radiation to outer space. Spectrally designed thermophotonic devices have raised substantial attention recently for their potential to provide passive and carbon-free alternatives to air conditioning. However, the level of transparency of the atmospheric window depends on the local content of water vapor in the atmosphere and on the optical depth of clouds in the local sky. Thus, the radiative cooling capacity of solar reflectors not only depends on the optical properties of their surfaces but also on local meteorological conditions. In this work, detailed radiative cooling resource maps for the contiguous United States are presented with the goal of determining the best climates for large-scale deployment of passive radiative cooling technologies. The passive cooling potential is estimated based on ideal optical properties, i.e., zero shortwave absorptance (maximum reflectance) and blackbody longwave emittance. Both annual and season-averaged maps are presented. Daytime and nighttime cooling potential are also computed and compared. The annual average cooling potential over the contiguous United States is 50.5 m -2 . The southwestern United States has the highest annual averaged cooling potential, over 70 W m -2 , due to its dry and mostly clear sky meteorological conditions. The southeastern United States has the lowest potential, around 30 W m -2 , due to frequent humid and/or overcast weather conditions. In the spring and fall months, the Arizona and New Mexico climates provide the highest passive cooling potential, while in the summer months, Nevada and Utah exhibit higher potentials. Passive radiative cooling is primarily effective in the western United States, while it is mostly ineffective in humid and overcast climates elsewhere.

Thermo optic effects↗

Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beams

Purpose: This work investigates the energy response and dose-response curve determinations for XR-QA2 radiochromic film dosimetry system used for synchrotron radiation work and for quality assurance in diagnostic radiology, in the range of effective energies 18–46.5 keV. Methods: Pieces of XR-QA2 films were irradiated, in a plane transverse to the beam axis, with a monochromatic beam of energy in the range 18–40 keV at the ELETTRA synchrotron radiation facility (Trieste, Italy) and with a polychromatic beam from a laboratory x-ray tube operated at 80, 100, and 120 kV. The film calibration curve was expressed as air kerma (measured free-in-air with an ionization chamber) versus the net optical reflectance change (netΔR) derived from the red channel of the RGB scanned film image. Four functional relationships (rational, linear exponential, power, and logarithm) were tested to evaluate the best curve for fitting the calibration data. The adequacy of the various fitting functions was tested by using the uncertainty analysis and by assessing the average of the absolute air kerma error calculated as the difference between calculated and delivered air kerma. The sensitivity of the film was evaluated as the ratio of the change in net reflectance to the corresponding air kerma. Results: The sensitivity of XR-QA2 films increased in the energy range 18–39 keV, with a maximum variation of about 170%, and decreased in the energy range 38–46.5 keV. The present results confirmed and extended previous findings by this and other groups, as regards the dose response of the radiochromic film XR-QA2 to monochromatic and polychromatic x-ray beams, respectively. Conclusions: The XR-QA2 radiochromic film response showed a strong dependence on beam energy for both monochromatic and polychromatic beams in the range of half value layer values from 0.55 to 6.1 mm Al and corresponding effective energies from 18 to 46.5 keV. In this range, the film response varied by 170%, from a minimum sensitivity of 0.0127 to a maximum sensitivity of 0.0219 at 10 mGy air kerma in air. The more suitable function for air kerma calibration of the XR-QA2 radiochromic film was the power function. A significant batch-to-batch variation, up to 55%, in film response at 120 kV (46.5 keV effective energy) was observed in comparison with published data.

61 RADIATION PROTECTION AND DOSIMETRY↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

Board Level Proton Testing Book of Knowledge for NASA Electronic Parts and Packaging Program

This book of knowledge (BoK) provides a critical review of the benefits and difficulties associated with using proton irradiation as a means of exploring the radiation hardness of commercial-off-the-shelf (COTS) systems. This work was developed for the NASA Electronic Parts and Packaging (NEPP) Board Level Testing for the COTS task. The fundamental findings of this BoK are the following. The board-level test method can reduce the worst case estimate for a board's single-event effect (SEE) sensitivity compared to the case of no test data, but only by a factor of ten. The estimated worst case rate of failure for untested boards is about 0.1 SEE/board-day. By employing the use of protons with energies near or above 200 MeV, this rate can be safely reduced to 0.01 SEE/board-day, with only those SEEs with deep charge collection mechanisms rising this high. For general SEEs, such as static random-access memory (SRAM) upsets, single-event transients (SETs), single-event gate ruptures (SEGRs), and similar cases where the relevant charge collection depth is less than 10 μm, the worst case rate for SEE is below 0.001 SEE/board-day. Note that these bounds assume that no SEEs are observed during testing. When SEEs are observed during testing, the board-level test method can establish a reliable event rate in some orbits, though all established rates will be at or above 0.001 SEE/board-day. The board-level test approach we explore has picked up support as a radiation hardness assurance technique over the last twenty years. The approach originally was used to provide a very limited verification of the suitability of low cost assemblies to be used in the very benign environment of the International Space Station (ISS), in limited reliability applications. Recently the method has been gaining popularity as a way to establish a minimum level of SEE performance of systems that require somewhat higher reliability performance than previous applications. This sort of application of the method suggests a critical analysis of the method is in order. This is also of current consideration because the primary facility used for this type of work, the Indiana University Cyclotron Facility (IUCF) (also known as the Integrated Science and Technology (ISAT) hall), has closed permanently, and the future selection of alternate test facilities is critically important. This document reviews the main theoretical work on proton testing of assemblies over the last twenty years. It augments this with review of reported data generated from the method and other data that applies to the limitations of the proton board-level test approach. When protons are incident on a system for test they can produce spallation reactions. From these reactions, secondary particles with linear energy transfers (LETs) significantly higher than the incident protons can be produced. These secondary particles, together with the protons, can simulate a subset of the space environment for particles capable of inducing single event effects (SEEs). The proton board-level test approach has been used to bound SEE rates, establishing a maximum possible SEE rate that a test article may exhibit in space. This bound is not particularly useful in many cases because the bound is quite loose. We discuss the established limit that the proton board-level test approach leaves us with. The remaining possible SEE rates may be as high as one per ten years for most devices. The situation is actually more problematic for many SEE types with deep charge collection. In cases with these SEEs, the limits set by the proton board-level test can be on the order of one per 100 days. Because of the limited nature of the bounds established by proton testing alone, it is possible that tested devices will have actual SEE sensitivity that is very low (e.g., fewer than one event in 1 × 10(exp 4) years), but the test method will only be able to establish the limits indicated above. This BoK further examines other benefits of proton board-level testing besides hardness assurance. The primary alternate use is the injection of errors. Error injection, or fault injection, is something that is often done in a simulation environment. But the proton beam has the benefit of injecting the majority of actual SEEs without risk of something being missed, and without the risk of simulation artifacts misleading the SEE investigation.

Guertin, Steven M.↗

Dosimetric and delivery efficiency investigation for treating hepatic lesions with a MLC-equipped robotic radiosurgery–radiotherapy combined system

Purpose: The CyberKnife M6 (CK-M6) Series introduced a multileaf collimator (MLC) for extending its capability from stereotactic radiosurgery/stereotactic radiotherapy (SBRT) to conventionally fractionated radiotherapy. This work is to investigate the dosimetric quality of plans that are generated using MLC-shaped beams on the CK-M6, as well as their delivery time, via comparisons with the intensity modulated radiotherapy plans that were clinically used on a Varian Linac for treating hepatic lesions. Methods: Nine patient cases were selected and divided into three groups with three patients in each group: (1) the group-one patients were treated conventionally (25 fractions); (2) the group-two patients were treated with SBRT-like hypofractionation (5 fractions); and (3) the group-three patients were treated similar to group-one patients, but with two planning target volumes (PTVs) and two different prescription dose levels correspondingly. The clinically used plans were generated on the ECLIPSE treatment planning system (TPS) and delivered on a Varian Linac (E-V plans). The multiplan (MP) TPS was used to replan these clinical cases with the MLC as the beam device for the CK-M6 (C-M plans). After plans were normalized to the same PTV dose coverage, comparisons between the C-M and E-V plans were performed based on D{sub 99%} (percentage of prescription dose received by 99% of the PTV), D{sub 0.1cm{sup 3}} (the percentage of prescription dose to 0.1 cm{sup 3} of the PTV), and doses received by critical structures. Then, the delivery times for the C-M plans will be obtained, which are the MP TPS generated estimations assuming having an imaging interval of 60 s. Results: The difference in D{sub 99%} between C-M and E-V plans is +0.6% on average (+ or − indicating a higher or lower dose from C-M plans than from E-V plans) with a range from −4.1% to +3.8%, and the difference in D{sub 0.1cm{sup 3}} was −1.0% on average with a range from −5.1% to +2.9%. The PTV conformity index (CI) for the C-M plans ranges from 1.07 to 1.29 with a mean of 1.19, slightly inferior to the E-V plans, in which the CI ranges from 1.00 to 1.15 with a mean of 1.07. Accounting for all nine patients in three groups, 45% of the critical structures received a lower mean dose for the C-M plans as compared with the E-V plans, and similarly, 48% received a lower maximum dose. Furthermore, the average difference of the mean critical structure dose between the C-M and E-V plans over all critical structures for all patients showed only +2.10% relative to the prescription dose and the similar comparison finds the average difference of the maximum critical structure dose of only +1.24%. The estimated delivery times for the C-M plans on the CK-M6 range from 18 to 24 minutes while they are from 7 to 13.7 min for the E-V plans on the Varian Linac. Conclusions: For treating hepatic lesions, for the C-M plans that are comparable to E-V plans in quality, the times needed to deliver these C-M plans on the CK-M6 are longer than the delivery time for the E-V plans on the Varian Linac, but may be clinically acceptable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving the energy response of external beam therapy (EBT) GafChromic{sup TM} dosimetry films at low energies (≤100 keV)

Purpose: Purpose of this work is to investigate the effects of varying the active layer composition of external beam therapy (EBT) GafChromic{sup TM} films on the energy dependence of the film, as well as try to develop a new prototype with more uniform energy response at low photon energies (⩽100 keV). Methods: First, the overall energy response (S{sub AD,} {sub W}(Q)) of different commercial EBT type film models that represent the three different generations produced to date, i.e., EBT, EBT2, and EBT3, was investigated. Pieces of each film model were irradiated to a fixed dose of 2 Gy to water for a wide range of beam qualities and the corresponding S{sub AD,} {sub W}(Q) was measured using a flatbed document scanner. Furthermore, the DOSRZnrc Monte Carlo code was used to determine the absorbed dose to water energy dependence of the film, f(Q). Moreover, the intrinsic energy dependence, k{sub bq}(Q), for each film model was evaluated using the corresponding S{sub AD,} {sub W}(Q) and f(Q). In the second part of this study, the authors investigated the effects of changing the chemical composition of the active layer on S{sub AD,} {sub W}(Q). Finally, based on these results, the film manufacturer fabricated several film prototypes and the authors evaluated their S{sub AD,} {sub W}(Q). Results: The commercial EBT film model shows an under response at all energies below 100 keV reaching 39% ± 4% at about 20 keV. The commercial EBT2 and EBT3 film models show an under response of about 27% ± 4% at 20 keV and an over response of about 16% ± 4% at 40 keV.S{sub AD,} {sub W}(Q) of the three commercial film models at low energies show strong correlation with the corresponding f{sup −1}(Q) curves. The commercial EBT3 model with 4% Cl in the active layer shows under response of 22% ± 4% at 20 keV and 6% ± 4% at about 40 keV. However, increasing the mass percent of chlorine makes the film more hygroscopic which may affect the stability of the film's readout. The EBT3 film prototype with 7.5% Si shows a significant improvement in the energy response at very low energies compared to the commercial EBT3 films with 4% Cl. It shows under response of 15% ± 5% at about 20 keV to 2% ± 5% at about 40 keV. However, according to the manufacturer, the addition of 7.5% Si as SiO{sub 2} adversely affected the viscosity of the active fluid and therefore affected the potential use in commercial machine coating. The latest commercial EBT3 film model with 7% Al as Al{sub 2}O{sub 3} shows an overall improvement in S{sub AD,} {sub W}(Q) compared to previous commercial EBT3 films. It shows under response at all energies <100 keV, varying from 20% ± 4% at 20 keV to 6% ± 4% at 40 keV. Conclusions: The energy response of films in the energy range <100 keV can be improved by adjusting the active layer chemical composition. Removing bromine eliminated the over response at about 40 keV. The under response at energies ≤30 keV is improved by adding 7% Al to the active layer in the latest commercial EBT3 film models.

61 RADIATION PROTECTION AND DOSIMETRY↗