Search NASA⌕ Search

SEARCH · Search NASA

Results for “Lab data'”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Comparison of Measured Direct Normal Irradiance Data to Calculated Using the Disc Model for the Texas Panhandle

It is important that we convert from fossil energy to wind and solar energy. Wind energy is currently the cheapest form of renewable energy, but it is usually a poor match to utility electrical generation in the Great Plains of the United States. Concentrating solar power (CSP) plants are a better match to utility electrical loading, but so far none of these plants have been constructed in the Great Plains. Part of the reason no CSP plants have been constructed is lack of confidence in the solar resource data required (direct normal irradiance or DNI for short). There are several models for converting global solar radiation to DNI, and one of them is the DISC model. Both DNI data and global radiation data were collected at the USDA-Agricultural Research Laboratory at Bushland, Texas, for the years 2009 and 2010. Using the DISC model and measured global radiation data, DNI was calculated and compared to measured DNI data. The total annual solar energy estimated with the model was 5% greater than what was actually measured which was fairly close. However, on a monthly or hourly basis, the percentage difference could be as high as 25%. Analysis of individual months and days resulted in some recommendations for improving the DISC model. Some of the poor correlations between measured solar energy and calculated solar energy using the DISC model implied that another model (DIRINDEX) might be better. Therefore, additional work is planned to investigate the DIRINDEX model with the same data set to see if the correlation improves. This work may potentially lead to the increased use of solar energy for electrical generation, which will decrease the use of fossil fuels and the environmental pollution from fossil fuel power plants. Direct normal irradiance (DNI) is required in the performance estimation of concentrating solar energy systems. The objective of this paper is to compare measured and modeled DNI data for a site in the Texas Panhandle (Bushland, Texas) to determine the accuracy of the model and where improvements might be required. The DNI model used was the Direct Insolation Simulation Code (DISC) which was developed at the National Renewable Energy Lab (NREL) in Boulder, Colorado. We have determined that a portion of the DISC standard deviation error is due to inaccurate modeling of the first and last hour of the day, but other inaccuracies of the DISC model are also discussed. The accuracy of the DISC model improves as the time scale increases (e.g. hour to month to year) due to errors cancelling, and for Bushland, Texas, the DISC model during 2009 predicted 5% more solar energy than the measured DNI.

14 SOLAR ENERGY↗

Atmospheric Science: Solving Challenges of Climate Change

PNNL’s atmospheric science research provides data required to make decisions about challenges presented by climate change: Where to site power plants, how to manage water resources, how to prepare for severe weather events and more. Our expertise in fundamental observations and modeling is recognized among the national labs and the world.

54 ENVIRONMENTAL SCIENCES↗

Mind the Gap: Summary of Window Residential Retrofit Solutions

Improving the insulation, solar heat gain, and infiltration characteristics of windows in a home has the potential to significantly improve the overall thermal performance by reducing heat transfer through the window and also by decreasing infiltration of outdoor air into the home. As approximately 43% of existing homes still have single-pane clear windows (~50 million houses) and millions of other homes have only double-pane clear windows (Cort 2013), improving window performance also presents a significant opportunity for energy savings in the residential sector. Today, various energy-saving window retrofit opportunities are available to homeowners, ranging from window coverings and storm panels to highly-insulating triple-pane R-5 window replacements. Many of these technologies have been evaluated in the field, in the “Lab Homes” at Pacific Northwest National Laboratory, and through modeling to prove their cost-effectiveness and performance in different climate regions. Recently, the Pacific Northwest’s Regional Technical Forum approved a utility measure for low- emissivity storm windows based on such data. This action represents a watershed moment for increasing the variety and prevalence of fenestration options in utility programs, especially for the low-income demographic. This paper will review various window retrofit options, the most recent field test and modeling data regarding their performance and cost-effectiveness, and discuss future rating efforts. This information is useful for utilities and energy-efficiency program managers to help effectively implement incentive measures for these technologies.

HVAC↗

Protein Mutation Stability Ternary Classification using Neural Networks and Rigidity Analysis

Discerning how a mutation affects the stability of a protein is central to the study of a wide range of diseases. Machine learning and statistical analysis techniques can inform how to allocate limited resources to the considerable time and cost associated with wet lab mutagenesis experiments. In this work we explore the effectiveness of predicting the change in the stability of a protein due to a mutation using a neural network classfier. Assessing the accuracy of our approach is dependent on the use of experimental data about the effects of mutations performed in vitro. Because the experimental data is prone to discrepancies when similar experiments have been performed by multiple laboratories, the use of the data near the juncture of stabilizing and destabilizing mutations is question- able. We address this later problem via a systematic approach in which we explore the use of a three-way classification scheme with stabilizing, destabilizing, and inconclusive labels. For a systematic search of potential classification cutoff values our classfier achieved 68 percent accuracy on ternary classification for cutoff values of -0.6 and 0.7 with a low rate of classifying stabilizing as destabilizing and vice versa.

Neural Network, Classification, protein stability,↗

Non-linear Multidimensional Optimization for use in Wire Scanner Fitting

To ensure experiment efficiency and quality from the Continuous Electron Beam Accelerator at Jefferson Lab, beam energy, size, and position must be measured. Wire scanners are devices inserted into the beamline to produce measurements which are used to obtain beam properties. Extracting physical information from the wire scanner measurements begins by fitting Gaussian curves to the data. This study focuses on optimizing and automating this curve-fitting procedure. We use a hybrid approach combining the efficiency of Newton Conjugate Gradient (NCG) method with the global convergence of three nature-inspired (NI) optimization approaches: genetic algorithm, differential evolution, and particle-swarm. In this Python-implemented approach, augmenting the locally-convergent NCG with one of the globally-convergent methods ensures the quality, robustness, and automation of curve-fitting. After comparing the methods, we establish that given an initial data-derived guess, each finds a solution with the same chi-square- a measurement of the agreement of the fit to the data. NCG is the fastest method, so it is the first to attempt data-fitting. The curve-fitting procedure escalates to one of the globally-convergent NI methods only if NCG fails, thereby ensuring a successful fit. This method allows for the most optimal signal fit and can be easily applied to similar problems.

Terzic, Balsa↗

60 years of science in ICF: from conception to scientific breakeven on the National Ignition Facility

The recent achievements of a burning plasma, fusion ignition, and scientific energy gain with deuterium-tritium (DT) fuel at Lawrence Livermore National Laboratory’s National Ignition Facility (NIF) represents a major milestone in the development of inertial confinement fusion (ICF) and all of fusion research. In these experiments, fuel pressures well in excess of hundreds of GBars were achieved in the compressed fuel, and robust alpha heating of the fuel, far in excess of the energy provided by the implosion, were demonstrated for the first time. These achievements occurred 60 years after the inception of ICF and the first laser demonstration, and were made possible by more than five decades of research at laser facilities around the world. Advances in laser technology both in wavelength and precision, motivated by improved understanding of laser-plasma interaction physics and the demands of targets; improvements in target fabrication inspired by the need to control and minimize hydrodynamic instabilities in the implosion; and multi-dimensional simulations and diagnostics have been critical to this achievement. This paper will summarize the scientific and technical advances, the surprises, and the challenges that had to be overcome to achieve these goals.

fusion↗

DEFENSE WASTE PROCESSING FACILITY ANALYTICAL METHOD VERIFICATION FOR THE SLUDGE BATCH 5 QUALIFICATION SAMPLE

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs confirmation of the applicability of the digestion method to be used by the DWPF lab for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) receipt samples and SRAT product process control samples. DWPF SRAT samples are typically dissolved using a room temperature HF-HNO3 acid dissolution (i.e., DWPF Cold Chem Method, see Procedure SW4-15.201) and then analyzed by inductively coupled plasma - atomic emission spectroscopy (ICP-AES). This report contains the results and comparison of data generated from performing the Aqua Regia (AR), Sodium Peroxide/Hydroxide Fusion (PF) and DWPF Cold Chem (CC) method digestion of Sludge Batch 5 (SB5) SRAT Receipt and SB5 SRAT Product samples. The SB5 SRAT Receipt and SB5 SRAT Product samples were prepared in the SRNL Shielded Cells, and the SRAT Receipt material is representative of the sludge that constitutes the SB5 Batch composition. This is the sludge in Tank 51 that is to be transferred into Tank 40, which will contain the heel of Sludge Batch 4 (SB4), to form the SB5 Blend composition. The results for any one particular element should not be used in any way to identify the form or speciation of a particular element in the sludge or used to estimate ratios of compounds in the sludge. A statistical comparison of the data validates the use of the DWPF CC method for SB5 Batch composition. However, the difficulty that was encountered in using the CC method for SB4 brings into question the adequacy of CC for the SB5 Blend. Also, it should be noted that visible solids remained in the final diluted solutions of all samples digested by this method at SRNL (8 samples total), which is typical for the DWPF CC method but not seen in the other methods. Recommendations to the DWPF for application to SB5 based on studies to date: (1) A dissolution study should be performed on the WAPS sample by SRNL which consists of the final composition of the sludge (the SB5 Blend); (2) Given the heel of SB4 in Tank 40, the DWPF lab should monitor the aluminum concentration in the first 10 SRAT Receipt batches of SB5 using both CC and sodium peroxide/hydroxide fusion to evaluate the adequacy of aluminum recovery by the CC method for this sludge batch; and (3) SRNL and the DWPF lab should investigate if comparisons between the elemental concentrations of the SME product glass (adjusted for frit addition) obtained by the mixed acid and peroxide fusion digestion and the SRAT Receipt and SRAT Product elemental concentrations obtained via the DWPF CC method provide insight into the adequacy of the CC method for analysis of the SRAT Product. The DWPF lab would need to calcine the SRAT product at 1050 C for the best comparison. If a consistent difference in elemental concentrations is revealed, another type of digestion (i.e. sodium peroxide/hydroxide fusion) should be used to determine the concentration of the element in question. Particular emphasis should be placed on monitoring the aluminum concentration in SB5.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cherenkov and scintillation light separation in organic liquid scintillators

The CHErenkov/Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2 g/L of PPO as a fluor (LAB/PPO). This is the first successful demonstration of Cherenkov light detection from the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 ± 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 ± 3 % and 63 ± 8 % for time- and charge-based separation, respectively, with scintillation contamination of 36 ± 5 % and 38 ± 4 %. LAB/PPO data is consistent with a rise time of τ r = 0.72 ± 0.33 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lab-Scale Development of a Solid Sorbent for CO 2 Capture Process for Coal-Fired Power Plants

It is increasingly clear that CO 2 capture and sequestration (CCS) must play a critical role in curbing worldwide CO 2 emissions to the atmosphere. Development of these technologies to cost-effectively remove CO 2 from coal-fired power plants is very important to mitigating the impact these power plants have within the world’s power generation portfolio. Currently, conventional CO 2 capture technologies, such as aqueous-monoethanolamine based solvent systems, are prohibitively expensive and if implemented could result in a 75 to 100% increase in the cost of electricity for consumers worldwide. Solid sorbent CO 2 capture processes – such as RTI’s 3rd Generation Solid Sorbent CO 2 Capture Process – are promising alternatives to conventional, liquid solvents. Supported amine sorbents – of the nature RTI has developed – are particularly attractive due to their potential for high CO 2 loadings, excellent stability over multiple cycles, reduced corrosivity/volatility and a potential to reduce the regeneration energy needed to carry out CO 2 capture. The remaining challenges for these sorbent processes have provided the framework for the project team’s research and development and target for advancing the technology beyond lab-scale testing. Previous work in this area has failed to adequately address various technology challenges such as sorbent stability and regenerability, sorbent scale-up, improved physical strength and attrition-resistance, proper heat management and temperature control, proper solids handling, as well as the proper coupling of process engineering advancements that are tailored for a promising sorbent technology. Under a cooperative agreement with the US Department of Energy, and part of NETL’s CO 2 Capture Program, RTI has led an effort to address and mitigate the challenges associated with solid sorbent CO 2 capture. The overall objective of this project was to mitigate the technical and economic risks associated with the performance and scale-up of solid sorbent-based CO 2 capture processes, enabling subsequent larger pilot demonstrations and ultimately commercial deployment. An integrated development approach has been a key focus of this project in which sorbent development, process development, and economic analyses have informed each of the other development processes. Development efforts have focused on developing novel hybrid solids-based CO 2 capture sorbents and improving their performance stability, refining process engineering and design, and evaluating the viability of the technology through detailed economic analyses. Sorbent advancements have led to a next generation, commercially-viable CO 2 capture sorbent exhibiting performance stability in various gas environments and a physically strong fluidizable form. The team has reduced sorbent production costs and optimized the production and scale-up of novel metal-organic framework (MOF) hybrid solids-based CO 2 capture sorbents, fluidizable sorbents. Refinement of the process engineering and design at the lab-scale research unit has demonstrated promising CO 2 capture performance in simulated coal-fired flue gas conditions. Long-term testing has informed the project team on the process conditions needed to operate a solids-based system for optimal performance. Data collected from all phases of testing has been used to develop a detailed techno-economic assessment of RTI’s technology. These detailed analyses show that RTI’s technology has significant economic advantages over current amine scrubbing and potential to achieve the DOE’s Carbon Capture Program’s goal of >90% CO 2 capture rate at a cost of almost $40/tonne CO 2 captured by 2025. Through this integrated technology development approach, the project team has advanced RTI’s 3rd generation CO 2 capture technology to TRL-3, according to the DOE/FE definitions for Technology Readiness Levels. At a broader level, this project has advanced the whole of the solid sorbent CO 2 capture field, with advancements in process engineering and design, technical risk mitigation, sorbent scale-up optimization, and an understanding of the commercial viability and applicability of solid sorbent CO 2 capture technologies for the U.S. existing fleet of coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Multipole Field Effects for the Superconducting Parallel-Bar Deflecting/Crabbing Cavities

The superconducting parallel-bar deflecting/crabbing cavity is currently being considered as one of the design options in rf separation for the Jefferson Lab 12 GeV upgrade and for the crabbing cavity for the proposed LHC luminosity upgrade. Knowledge of multipole field effects is important for accurate beam dynamics study of rf structures. The multipole components can be accurately determined numerically using the electromagnetic surface field data in the rf structure. This paper discusses the detailed analysis of those components for the fundamental deflecting/crabbing mode and higher order modes in the parallel-bar deflecting/crabbing cavity.

43 PARTICLE ACCELERATORS↗

Sustainable Campus with PEV and Microgrid

Market penetration of electric vehicles (EVs) is gaining momentum, as is the move towards increasingly distributed, clean and renewable electricity sources. EV charging shifts a significant portion of transportation energy use onto building electricity meters. Hence, integration strategies for energy-efficiency in buildings and transport sectors are of increasing importance. This paper focuses on a portion of that integration: the analysis of an optimal interaction of EVs with a building-serving transformer, and coupling it to a microgrid that includes PV, a fuel cell and a natural gas micro-turbine. The test-case is the Nanyang Technological University (NTU), Singapore campus. The system under study is the Laboratory of Clean Energy Research (LaCER) Lab that houses the award winning Microgrid Energy Management System (MG-EMS) project. The paper analyses three different case scenarios to estimate the number of EVs that can be supported by the building transformer serving LaCER. An approximation of the actual load data collected for the building into different time intervals is performed for a transformer loss of life (LOL) calculation. The additional EV loads that can be supported by the transformer with and without the microgrid are analyzed. The numbers of possible EVs that can be charged at any given time under the three scenarios are also determined. The possibility of using EV fleet at NTU campus to achieve demand response capability and intermittent PV output leveling through vehicle to grid (V2G) technology and building energy management systems is also explored.

Singh, Reshma↗

Tools Assessing Performance (TAP) 2.0

Dmitry Duplyakin will be presenting on the latest research and results in the Tools Assessing Performance (TAP) 2.0 project. This presentation will include updates on the latest data the group has produced, integration of obstacle models in the computational pipeline for distributed wind siting, and the plans for the near-term analysis and validation efforts. The talk will acknowledge the work of collaborators from NREL and three other national labs - ANL, LANL, and PNNL - all contributing to this multi-year project.

distributed wind↗

An improved direct limit on the muon electric dipole moment

A limit on the permanent electric dipole moment (EDM) of the positive muon is presented based on data from the Fermilab Muon g-2 Experiment taken between 2019 and 2020. The tracking detectors measure the average vertical decay angle of positrons from muon decays, enabling a search for an interaction between a possible muon EDM $d_μ$ and the lab-frame magnetic field. The result, $d_μ= (-0.35 \pm 0.19_{\mathrm{stat}} \pm 0.34_{\mathrm{sys}}) \times10^{-19}~e\cdot$cm, is consistent with zero and sets a new direct limit on the muon EDM of $|d_μ|<1.10\times10^{-19}~e\cdot$cm at the 95 percent confidence level.

Aguillard, D. P. [Michigan U.] (ORCID:000000025556↗

Initial approaches in benchmarking and round robin testing for proton exchange membrane water electrolyzers

As ever increasing amounts of renewable electricity enter the energy supply mix on a regional, national and international basis, greater emphasis is being placed on energy conversion and storage technologies to deal with the oscillations, excess and lack of electricity. Hydrogen generation via proton exchange membrane water electrolysis (PEMWE) is one technology that offers a pathway to store large amounts of electricity in the form of hydrogen. The challenges to widespread adoption of PEMWE lie in their high capital and operating costs which both need to be reduced through R&D. An evaluation of reported performance data in literature for PEMWE reveals that there are excessive variations of in situ performance results that make it difficult to draw conclusions on the pathway forward to performance optimization and future R&D directions. In order to enable the meaningful comparison of in-situ performance evaluation across laboratories there is an obvious need for standardization of materials and testing protocols. Herein, we address this need by reporting the results of a round robin test effort conducted at the laboratories of five contributors to the IEA electrolysis annex 30. The effort utilized common sets of test articles, materials, test cells, and employed a set of shared test protocols. The maximum observed deviation between laboratories at 1 A cm-2 at cell temperatures of 60 and 80 degrees C, was 27 and 20 mV, respectively. The deviation of the results from laboratory to laboratory was a factor of 2-3 higher than the lowest deviation observed at one single lab and test station. However, the highest deviations observed were 1/10th of those extracted by a literature survey on similar material sets. The biggest takeaways are that cell temperature control appears to be the most significant source of deviation between results, while care must be taken with respect to break in conditions and cell electrical connections for meaningful performance data.

08 HYDROGEN↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Utah FORGE Hydrothermal Friction-Hydraulic Transmissivity Laboratory Experiments

Submission includes data from laboratory slide-hold-slide tests, combined with flow through tests, conducted on Westerly granite with 30 degree sawcut. Tests were conducted with a constant confining pressure of 30 MPa with an average pore pressure of 10 MPa at temperatures of 23 and 200 degC. Three fluid flow conditions were examined (1) no flow, (2) cycled flow, and (3) continuous flow. Data were collected to asses the effect of temperature and pore fluid on frictional healing rates in granite at geothermal conditions. Data is available in XML and JSON data types.

15 GEOTHERMAL ENERGY↗