Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Solving the Hele–Shaw flow using the Harrow–Hassidim–Lloyd algorithm on superconducting devices: A study of efficiency and challenges

The development of quantum processors for practical fluid flow problems is a promising yet distant goal. Recent advances in quantum linear solvers have highlighted their potential for classical fluid dynamics. In this study, we evaluate the Harrow–Hassidim–Lloyd (HHL) quantum linear systems algorithm (QLSA) for solving the idealized Hele–Shaw flow. Our focus is on the accuracy and computational cost of the HHL solver, which we find to be sensitive to the condition number, scaling exponentially with problem size. This emphasizes the need for preconditioning to enhance the practical use of QLSAs in fluid flow applications. Moreover, we perform shots-based simulations on quantum simulators and test the HHL solver on superconducting quantum devices, where noise, large circuit depths, and gate errors limit performance. Error suppression and mitigation techniques improve accuracy, suggesting that such fluid flow problems can benchmark noise mitigation efforts. Finally, our findings provide a foundation for future, more complex application of QLSAs in fluid flow simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Density weighted angular redshift fluctuations: a new cosmological observable

We propose the use of angular fluctuations in the galaxy redshift field as a new way to extract cosmological information in the Universe. This new probe $\delta z (\hat{\mathbf {n}})$ consists of the statistics of sky maps built by projecting redshifts under a Gaussian window of width σz centred upon a redshift zobs, and weighted by the galaxy density field. We compute the angular power spectrum of the $\delta z (\hat{\mathbf {n}})$ field in both numerical simulations and in linear perturbation theory. From these, we find that the $\delta z (\hat{\mathbf {n}})$ field (i) is sensitive to the underlying density and peculiar velocity fields; (ii) is highly correlated, at the $\gtrsim 60\, {{\ \rm per\ cent}}$ level, to the line-of-sight projected peculiar velocity field; (iii) for narrow windows (σz < 0.03), it is almost completely uncorrelated to the projected galaxy angular density field under the same redshift window; and (iv) it is largely unaffected by multiplicative and additive systematic errors on the observed number of galaxies that are redshift-independent over ~σz. We conclude that $\delta z (\hat{\mathbf {n}})$ is a simple and robust tomographic measure of the cosmic density and velocity fields, complementary to angular clustering, that will contribute to more complete exploitations of current and upcoming galaxy redshift surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Inverted initial conditions: Exploring the growth of cosmic structure and voids

We introduce and explore “paired” cosmological simulations. A pair consists of an A and B simulation with initial conditions related by the inversion δ A (x,t initial ) = –δ B (x,t initial ) (underdensities substituted for overdensities and vice versa). We argue that the technique is valuable for improving our understanding of cosmic structure formation. The A and B fields are by definition equally likely draws from ΛCDM initial conditions, and in the linear regime evolve identically up to the overall sign. As nonlinear evolution takes hold, a region that collapses to form a halo in simulation A will tend to expand to create a void in simulation B. Applications include (i) contrasting the growth of A-halos and B-voids to test excursion-set theories of structure formation, (ii) cross-correlating the density field of the A and B universes as a novel test for perturbation theory, and (iii) canceling error terms by averaging power spectra between the two boxes. Furthermore, generalizations of the method to more elaborate field transformations are suggested.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-AB-202-01: Daily Lung Tumor Motion Characterization On EPIDs Using a Markerless Tiling Model

Purpose: Tracking lung tumor motion in real time allows for target dose escalation while simultaneously reducing dose to sensitive structures, thus increasing local control without increasing toxicity. We present a novel intra-fractional markerless lung tumor tracking algorithm using MV treatment beam images acquired during treatment delivery. Strong signals superimposed on the tumor significantly reduced the soft tissue resolution; while different imaging modalities involved introduce global imaging discrepancies. This reduced the comparison accuracies. A simple yet elegant Tiling algorithm is reported to overcome the aforementioned issues. Methods: MV treatment beam images were acquired continuously in beam’s eye view (BEV) by an electronic portal imaging device (EPID) during treatment and analyzed to obtain tumor positions on every frame. Every frame of the MV image was simulated by a composite of two components with separate digitally reconstructed radiographs (DRRs): all non-moving structures and the tumor. This Titling algorithm divides the global composite DRR and the corresponding MV projection into sub-images called tiles. Rigid registration is performed independently on tile-pairs in order to improve local soft tissue resolution. This enables the composite DRR to be transformed accurately to match the MV projection and attain a high correlation value through a pixel-based linear transformation. The highest cumulative correlation for all tile-pairs achieved over a user-defined search range indicates the 2-D coordinates of the tumor location on the MV projection. Results: This algorithm was successfully applied to cine-mode BEV images acquired during two SBRT plans delivered five times with different motion patterns to each of two phantoms. Approximately 15000 beam’s eye view images were analyzed and tumor locations were successfully identified on every projection with a maximum/average error of 1.8 mm / 1.0 mm. Conclusion: Despite the presence of strong anatomical signal overlapping with tumor images, this markerless detection algorithm accurately tracks intrafractional lung tumor motions. This project is partially supported by an Elekta research grant.

60 APPLIED LIFE SCIENCES↗

Learning an Algebriac Multrigrid Interpolation Operator Using a Modified GraphNet Architecture

This work, building on previous efforts, develops a suite of new graph neural network machine learning architectures that generate data-driven prolongators for use in Algebraic Multigrid (AMG). Algebraic Multigrid is a powerful and common technique for solving large, sparse linear systems. Its effectiveness is problem dependent and heavily depends on the choice of the prolongation operator, which interpolates the coarse mesh results onto a finer mesh. Previous work has used recent developments in graph neural networks to learn a prolongation operator from a given coefficient matrix. In this paper, we expand on previous work by exploring architectural enhancements of graph neural networks. A new method for generating a training set is developed which more closely aligns to the test set. Asymptotic error reduction factors are compared on a test suite of 3-dimensional Poisson problems with varying degrees of element stretching. Results show modest improvements in asymptotic error factor over both commonly chosen baselines and learning methods from previous work.

97 MATHEMATICS AND COMPUTING↗

Three-dimensional liver motion tracking using real-time two-dimensional MRI

Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact video content representation for video coding using low multi-linear tensor rank approximation with dynamic core tensor order

Tensor is a multi-way representation of an entity that is widely used in many applications of mathematics and physics. The wide range of tensor algebra operations attract the researchers of graphical and vision field to identify unique methods for various applications such as segmentation, compression, indexing and so on. In this paper, low multi-linear rank approximation of a tensor is used for decomposition so as to perform compression on a video that is represented as a 4D tensor. Thus, the encoder has blocks for (1) multilinear rank approximation method so as to aid decomposition, (2) sparsity removal of residual data to reduce the required memory storage to a small level, (3) quantization on the sparse less residual data and (4) LZ77 dictionary coding for the video. The decoder uses a tensor reconstruction block along with residual error correction block that reduces loss/error in the reconstructed video. The size of core tensor is an important factor in rank approximation. It is identified at run time depending on the video contents. This size is determined adaptively using Tikhonov’s regularization method. The best value of core tensor size is identified with the corner of L-curve which preserves the video contents from heavy loss/error. Experimental results of the proposed work on comparison with H.264/AVC compression method indicate that the proposed method achieves up to 10% improvement in compression ratio with the least amount of loss and a maximum signal to noise ratio of 0.14. The proposed system gives better compression ratio than H.265 for videos with more number of frames without compromising quality.

97 MATHEMATICS AND COMPUTING↗

THE JETS OF TeV BLAZARS AT HIGHER RESOLUTION: 43 GHz AND POLARIMETRIC VLBA OBSERVATIONS FROM 2005 TO 2009

We present 23 new VLBA images of the six established TeV blazars Markarian 421, Markarian 501, H 1426+428, 1ES 1959+650, PKS 2155-304, and 1ES 2344+514, obtained from 2005 to 2009. Most images were obtained at 43 GHz (7 mm), and they reveal the parsec-scale structures of three of these sources (1ES 1959+650, PKS 2155-304, and 1ES 2344+514) at factors of 2-3 higher resolution than has previously been attained. These images reveal new morphological details, including a high degree of jet bending in the inner milliarcsecond in PKS 2155-304. This establishes strong apparent jet bending on VLBI scales as a common property of TeV blazars, implying viewing angles close to the line of sight. Most of the remaining images map the linear polarization structures at a lower frequency of 22 GHz (1 cm). We discuss the transverse structures of the jets as revealed by the high-frequency and polarimetric imaging. The transverse structures include significant limb brightening in Mrk 421, and 'spine-sheath' structures in the electric vector position angle and fractional polarization distributions in Mrk 421, Mrk 501, and 1ES 1959+650. We use new measured component positions to update measured apparent jet speeds, in many cases significantly reducing the statistical error over previously published results. With the increased resolution at 43 GHz, we detect new components within 0.1-0.2 mas of the core in most of these sources. No motion is apparent in these new components over the time span of our observations, and we place upper limits on the apparent speeds of the components near the core of <2c. From those limits, we conclude that {Gamma}{sub 2} < ({Gamma}{sub 1}){sup 1/2} at {approx}10{sup 5} Schwarzschild radii, where {Gamma}{sub 1} and {Gamma}{sub 2} are the bulk Lorentz factors in the TeV emitting and 43 GHz emitting regions, respectively, assuming that their velocity vectors are aligned.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrating proteomic or transcriptomic data into metabolic models using linear bound flux balance analysis

Abstract Motivation Transcriptomics and proteomics data have been integrated into constraint-based models to influence flux predictions. However, it has been reported recently for Escherichia coli and Saccharomyces cerevisiae, that model predictions from parsimonious flux balance analysis (pFBA), which does not use expression data, are as good or better than predictions from various algorithms that integrate transcriptomics or proteomics data into constraint-based models. Results In this paper, we describe a novel constraint-based method called Linear Bound Flux Balance Analysis (LBFBA), which uses expression data (either transcriptomic or proteomic) to predict metabolic fluxes. The method uses expression data to place soft constraints on individual fluxes, which can be violated. Parameters in the soft constraints are first estimated from a training expression and flux dataset before being used to predict fluxes from expression data in other conditions. We applied LBFBA to E.coli and S.cerevisiae datasets and found that LBFBA predictions were more accurate than pFBA predictions, with average normalized errors roughly half of those from pFBA. For the first time, we demonstrate a computational method that integrates expression data into constraint-based models and improves quantitative flux predictions over pFBA. Availability and implementation Code is available in the Supplementary data available at Bioinformatics online. Supplementary information Supplementary data are available at Bioinformatics online.

Tian, Mingyuan↗

Modelling galaxy cluster triaxiality in stacked cluster weak lensing analyses

Counts of galaxy clusters offer a high-precision probe of cosmology, but control of systematic errors will determine the accuracy of this measurement. Using Buzzard simulations, we quantify one such systematic, the triaxiality distribution of clusters identified with the redMaPPer optical cluster finding algorithm, which was used in the Dark Energy Survey Year-1 (DES Y1) cluster cosmology analysis. We test whether redMaPPer selection biases the clusters’ shape and orientation and find that it only biases orientation, preferentially selecting clusters with their major axes oriented along the line of sight. Modelling the richness–mass relation as log-linear, we find that the log-richness amplitude ln (A) is boosted from the lowest to highest orientation bin with a significance of 14σ, while the orientation dependence of the richness-mass slope and intrinsic scatter is minimal. We also find that the weak lensing shear-profile ratios of cluster-associated dark haloes in different orientation bins resemble a ‘bottleneck’ shape that can be quantified with a Cauchy function. We test the correlation of orientation with two other leading systematics in cluster cosmology – miscentering and projection – and find a null correlation. The resulting mass bias predicted from our templates confirms the DES Y1 finding that triaxiality is a leading source of bias in cluster cosmology. However, the richness-dependence of the bias confirms that triaxiality does not fully resolve the tension at low-richness between DES Y1 cluster cosmology and other probes. Our model can be used for quantifying the impact of triaxiality bias on cosmological constraints for upcoming weak lensing surveys of galaxy clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiochromic EBT2 film dosimetry for low-energy protontherapy

Purpose: In protontherapy, accessories are used in order to adapt the beam to the surface and to the depth of the target. They are positioned close to the patient in order to avoid perturbation effects related to proton scattering. The level of contamination of the beam caused by these accessories may be assessed by examining the dose maps in parallel planes to the beam incidence. The EBT2 radiochromic film is a suitable tool for this task, as it can be cut into small pieces and immersed in water. Prior to use the EBT2 film for dose measurements, its response when exposed to a proton beam must be analysed. Methods: The measurements were performed at the Centre Antoine Lacassagne, using the hospital-based MEDICYC isochronous cyclotron which provides 65 MeV protons. Monoenergetic as well as polyenergetic beams were used. Small pieces of EBT2 films were irradiated with proton beams in a small water phantom. Films were exposed at various angles close to the beam incidence and received doses ranging from 0.25 to 500 Gy. The optical density (OD) was studied as a function of angle, dose and linear energy transfer (LET). Results: The effective atomic number of the active layer of the film is close to that of water which prevents disturbances of the measurement. However, the high density and the significant thickness of the Mylar substrate surrounding the active layer affect the use of the film in a parallel orientation to the beam. Therefore, the substrate layer may totally or partially slow down the protons. The measurement is then no longer representative to what happens in water. The measurement errors can be corrected by applying a tilt angle of at least 5 deg. between the film and the beam. The dose analysis reveals that the green channel is the most sensitive in the dose range from 1 to 100 Gy. The OD is accurately described by a Weibull function of the dose with four free parameters. The Weibull function is valid for both monoenergetic and polyenergetic beams if the LET is limited to values below 15 MeV g{sup -1} cm{sup 2}. When using a film orientation close to the beam incidence angle, increasing LET values are encountered throughout the film axis gradually with the protons slowing down in water. The EBT2 films show an underestimated response for higher LET values. The comparison of data from the present study to data obtained by other authors for EBT films allows modelling the underestimated response as a function of the LET. The definition improvement of the link between OD and LET requires to integrate more closely the beam energy characteristics. Conclusions: The EBT2 film is a suitable dosimeter for analysing dose plans in planes nearly parallel to the beam orientation by compensating the underestimated dose response due to LET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fifth-kind orthonormal Chebyshev polynomial solutions for fractional differential equations

The principal aim of the current paper is to present and analyze two new spectral algorithms for solving some types of linear and nonlinear fractional-order differential equations. The proposed algorithms are obtained by utilizing a certain kind of shifted Chebyshev polynomials called the shifted fifth-kind Chebyshev polynomials as basis functions along with the application of a modified spectral tau method. The class of fifth-kind Chebyshev polynomials is a special class of a basic class of symmetric orthogonal polynomials which are constructed with the aid of the extended Sturm–Liouville theorem for symmetric functions. An investigation for the convergence and error analysis of the proposed Chebyshev expansion is performed. For this purpose, a new connection formulae between Chebyshev polynomials of the first and fifth kinds are derived. The obtained numerical results ascertain that our two proposed algorithms are applicable, efficient and accurate.

97 MATHEMATICS AND COMPUTING↗

Global reconstructed daily surge levels from the 20th Century Reanalysis (1871–2010)

Studying the effect of global patterns of wind and pressure gradients on the sea level variation (storm surge) is a key issue in understanding the recent climate change effect on the dynamical state of the ocean. The analysis of the spatial and temporal variability of storm surges from observations is a difficult task to accomplish since observations are not homogeneous in time, scarce in space, and moreover, their temporal coverage is limited. A recent global surge database developed by AVISO (DAC, Dynamic Atmospheric Correction) fulfilled the lack of data in terms of spatial coverage, but not regarding time extent, since it only includes the last two decades (1992–2014). In this work, we use the 20th Century Reanalysis V2 (20CR), which spans the years 1871 to 2010, to statistically reconstruct daily maximum surge levels at a global scale. A multivariate linear regression model is fitted between daily mean ERA-interim sea level pressure fields and daily maximum surge levels from DAC. Following, the statistical model is used to reconstruct daily surges using mean sea level pressure fields from 20CR. The verification of the statistical model shows good agreements between DAC levels and the reconstructed surge levels from the 20CR. The validation of the reconstructed surge with tide gauges, distributed throughout the domain, shows good accuracy both in terms of high correlations and small errors. A time series comparison is also depicted at specific tide gauges for the beginning of the 20th century, showing a high concordance. Therefore, this work provides to the scientific community, a daily database of maximum surge levels; which correspond to an extension of the DAC database, from 1871 to 2010. This database can be used to improve the knowledge on historical storm surge conditions, allowing the study of their temporal and spatial variability.

Geology↗

Tracking Accuracy of a Real-Time Fiducial Tracking System for Patient Positioning and Monitoring in Radiation Therapy

Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Technique for Generating Volumetric Cine-Magnetic Resonance Imaging

Purpose: The purpose of this study was to develop a techique to generate on-board volumetric cine-magnetic resonance imaging (VC-MRI) using patient prior images, motion modeling, and on-board 2-dimensional cine MRI. Methods and Materials: One phase of a 4-dimensional MRI acquired during patient simulation is used as patient prior images. Three major respiratory deformation patterns of the patient are extracted from 4-dimensional MRI based on principal-component analysis. The on-board VC-MRI at any instant is considered as a deformation of the prior MRI. The deformation field is represented as a linear combination of the 3 major deformation patterns. The coefficients of the deformation patterns are solved by the data fidelity constraint using the acquired on-board single 2-dimensional cine MRI. The method was evaluated using both digital extended-cardiac torso (XCAT) simulation of lung cancer patients and MRI data from 4 real liver cancer patients. The accuracy of the estimated VC-MRI was quantitatively evaluated using volume-percent-difference (VPD), center-of-mass-shift (COMS), and target tracking errors. Effects of acquisition orientation, region-of-interest (ROI) selection, patient breathing pattern change, and noise on the estimation accuracy were also evaluated. Results: Image subtraction of ground-truth with estimated on-board VC-MRI shows fewer differences than image subtraction of ground-truth with prior image. Agreement between normalized profiles in the estimated and ground-truth VC-MRI was achieved with less than 6% error for both XCAT and patient data. Among all XCAT scenarios, the VPD between ground-truth and estimated lesion volumes was, on average, 8.43 ± 1.52% and the COMS was, on average, 0.93 ± 0.58 mm across all time steps for estimation based on the ROI region in the sagittal cine images. Matching to ROI in the sagittal view achieved better accuracy when there was substantial breathing pattern change. The technique was robust against noise levels up to SNR = 20. For patient data, average tracking errors were less than 2 mm in all directions for all patients. Conclusions: Preliminary studies demonstrated the feasibility of generating real-time VC-MRI for on-board localization of moving targets in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiresolution 3D-DenseNet for Chemical Shift Prediction in NMR Crystallography

We have developed a deep learning algorithm for chemical shift prediction for atoms in molecular crystals that utilizes an atom-centered Gaussian density model for the 3D data representation of a molecule. We define multiple channels that describe different spatial resolutions for each atom type that utilizes cropping, pooling, and concatenation to create a multiresolution 3D-DenseNet architecture (MR-3D-DenseNet). Because the training and testing time scale linearly with the number of samples, the MR-3D-DenseNet can exploit data augmentation that takes into account the property of rotational invariance of the chemical shifts, thereby also increasing the size of the training data set by an order of magnitude without additional cost. We obtain very good agreement for 13 C, 15 N, and 17 O chemical shifts when compared to ab initio quantum chemistry methods, with the highest accuracy found for 1 H chemical shifts that is comparable to the error between the ab initio results and experimental measurements. Principal component analysis (PCA) is used to both understand these greatly improved predictions for 1 H , as well as indicating that chemical shift prediction for 13 C, 15 N, and 17 O, which have far fewer training environments than the 1 H atom type, will improve once more unique training samples are made available to exploit the deep network architecture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AN ALGORITHM FOR RADIATION MAGNETOHYDRODYNAMICS BASED ON SOLVING THE TIME-DEPENDENT TRANSFER EQUATION

We describe a new algorithm for solving the coupled frequency-integrated transfer equation and the equations of magnetohydrodynamics in the regime that light-crossing time is only marginally shorter than dynamical timescales. The transfer equation is solved in the mixed frame, including velocity-dependent source terms accurate to O(v/c). An operator split approach is used to compute the specific intensity along discrete rays, with upwind monotonic interpolation used along each ray to update the transport terms, and implicit methods used to compute the scattering and absorption source terms. Conservative differencing is used for the transport terms, which ensures the specific intensity (as well as energy and momentum) are conserved along each ray to round-off error. The use of implicit methods for the source terms ensures the method is stable even if the source terms are very stiff. To couple the solution of the transfer equation to the MHD algorithms in the ATHENA code, we perform direct quadrature of the specific intensity over angles to compute the energy and momentum source terms. We present the results of a variety of tests of the method, such as calculating the structure of a non-LTE atmosphere, an advective diffusion test, linear wave convergence tests, and the well-known shadow test. We use new semi-analytic solutions for radiation modified shocks to demonstrate the ability of our algorithm to capture the effects of an anisotropic radiation field accurately. Since the method uses explicit differencing of the spatial operators, it shows excellent weak scaling on parallel computers.

79 ASTRONOMY AND ASTROPHYSICS↗