Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Pantex Forklift Field Measurement Report

The Lawrence Livermore National Laboratory (LLNL) container program requested measurements of forklift handling shock and vibration environments for the Pantex ramp areas to inform container design. LLNL test group personnel directed the instrumentation and measurement of representative metal-framed pallets loaded by a variety of pallet weights according to the released test plan detailed in LLNL document CODT-2018-1253. This report details the testing, data processing, and presents proposed breakpoint values for random vibration and shock environments.

42 ENGINEERING↗

CO2 Acquisition Membrane (CAM)

The objective of CAM is to develop, test, and analyze thin film membrane materials for separation and purification of carbon dioxide (CO2) from mixtures of gases, such as those found in the Martian atmosphere. The membranes are targeted toward In Situ Resource Utilization (ISRU) applications that will operate in extraterrestrial environments and support future unmanned and human space missions. A primary application is the Sabatier Electrolysis process that uses Mars atmosphere CO2 as raw material for producing water, oxygen, and methane for rocket fuel and habitat support. Other applications include use as an inlet filter to collect and concentrate Mars atmospheric argon and nitrogen gases for habitat pressurization, and to remove CO2 from breathing gases in Closed Environment Life Support Systems (CELSS). CAM membrane materials include crystalline faujasite (FAU) zeolite and rubbery polymers such as silicone rubber (PDMS) that have been shown in the literature and via molecular simulation to favor adsorption and permeation of CO2 over nitrogen and argon. Pure gas permeation tests using commercial PDMS membranes have shown that both CO2 permeance and the separation factor relative to other gases increase as the temperature decreases, and low (Delta)P(Sub CO2) favors higher separation factors. The ideal CO2/N2 separation factor increases from 7.5 to 17.5 as temperature decreases from 22 C to -30 C. For gas mixtures containing CO2, N2, and Ar, plasticization decreased the separation factors from 4.5 to 6 over the same temperature range. We currently synthesize and test our own Na(+) FAU zeolite membranes using standard formulations and secondary growth methods on porous alumina. Preliminary tests with a Na(+) FAU membrane at 22 C show a He/SF6 ideal separation factor of 62, exceeding the Knudsen diffusion selectivity by an order of magnitude. This shows that the membrane is relatively free from large defects and associated non-selective (viscous flow) transport mechanisms. The Membrane Test Facility (MTF) has been developed to measure membrane permeance over a wide range of temperature and pressure. The facility uses two volume compartments separated by the membrane that are instrumented to measure temperature, delta pressure across the membrane, and gas composition. A thermal shroud supports and encloses the membrane, and provides temperature control. Methods were developed to determine membrane permeance using the first order decay of the pressure difference between the sealed compartments, using the total pressure for pure gases, and partial pressure of each species in gas mixtures. The technique provides an end-to-end measurement of gas permeance that includes concentration polarization effects. Experiments have shown that in addition to membrane permeance properties, the geometry and design of associated structures play an important role in how membrane systems will function on Mars.

Mason, Larry W.↗

Multiple Laser Tracker Synchronization for the Vibration Analysis

Measuring the mechanical coupling and rigidity of a large apparatus presents unique challenges for 3D metrology. In this case the motion of well separated points attached to a rotor blade must be rapidly and repeatedly measured and the resulting data synchronized. This presentation describes the methodology and results for the mechanical coupling test of the magnetic field mapping system (FMS) for the Mu2e experiment at Fermi National Accelerator Laboratory (Fermilab). Three laser trackers, 2 API Radians and an API TIII, simultaneously measured the position of three cylindrical corner cube reflectors mounted on the FMS while the system was in motion and after coming to rest. The laser trackers took measurements at 83Hz for the T3 and 100Hz for the Radians, with fine spatial resolution, resulting in over 20,000 points measured per instrument in observation cycle. The laser tracker hardware and utilized software are unable to synchronize the three independent data streams directly during the measurement process. Instead a custom software program was developed to perform this synchronization of the data sequences during post-processing using features of the targets motion common to all three fiducial locations.

43 PARTICLE ACCELERATORS↗

NASA's Future Active Remote Sensing Missing for Earth Science

Since the beginning of space remote sensing of the earth, there has been a natural progression widening the range of electromagnetic radiation used to sense the earth, and slowly, steadily increasing the spatial, spectral, and radiometric resolution of the measurements. There has also been a somewhat slower trend toward active measurements across the electromagnetic spectrum, motivated in part by increased resolution, but also by the ability to make new measurements. Active microwave instruments have been used to measure ocean topography, to study the land surface. and to study rainfall from space. Future NASA active microwave missions may add detail to the topographical studies, sense soil moisture, and better characterize the cryosphere. Only recently have active optical instruments been flown in space by NASA; however, there are currently several missions in development which will sense the earth with lasers and many more conceptual active optical missions which address the priorities of NASA's earth science program. Missions are under development to investigate the structure of the terrestrial vegetation canopy, to characterize the earth's ice caps, and to study clouds and aerosols. Future NASA missions may measure tropospheric vector winds and make vastly improved measurements of the chemical components of the earth's atmosphere.

Hartley, Jonathan B.↗

Development of a Coherent Differential Absorption Lidar for Range Resolved Atmospheric CO2 Measurements

A pulsed, 2-m coherent Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) transceiver, developed under the Laser Risk Reduction Program (LRRP) at NASA, is integrated into a fully functional lidar instrument. This instrument will measure atmospheric CO2 profiles (by DIAL) initially from a ground platform, and then be prepared for aircraft installation to measure the atmospheric CO2 column densities in the atmospheric boundary layer (ABL) and lower troposphere. The airborne prototype CO2 lidar can measure atmospheric CO2 column density in a range bin of 1km with better than 1.5% precision at horizontal resolution of less than 50km. It can provide the image of the pooling of CO2 in lowlying areas and performs nighttime mass balance measurements at landscape scale. This sensor is unique in its capability to study the vertical ABL-free troposphere exchange of CO2 directly. It will allow the investigators to pursue subsequent in science-driven deployments, and provides a unique tool for Active Sensing of CO2 Emissions over Night, Days, and Seasons (ASCENDS) validation that was strongly advocated in the recent ASCENDS Workshop.

Yu, Jirong↗

SPIRIT - A high resolution cosmic ray isotope spectrometer for Spacelab

An instrument to measure the isotopic abundances of cosmic ray nuclei with Z in the range 20-30 and A in the range 40-70 has been conceived. The instrument, named SPIRIT (Superconducting Passive Iron Isotope Telescope), will have the mass resolution (sigma less than 0.15 amu) and collecting power (151 sq m ster h for a 10 day flight) to detect and convincingly resolve isotopes as rare as 0.5% of the total abundance of each element. Both range and magnetic rigidity are measured by following tracks through an array of sheets of CR-39, a sensitive new track-recording plastic, which had been kept in fixed position at uniform temperature within the uniform field region of a large superconducting magnet.

Tarle, G.↗

Evaluation of the hyperspectral radiometer (HSR1) at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site

Abstract. The Peak Design Ltd hyperspectral radiometer (HSR1) was tested at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site in Lamont, Oklahoma, for 2 months from May to July 2022. The HSR1 is a prototype instrument that measures total (Ftotal) and diffuse (Fdiffuse) spectral irradiance from 360 to 1100 nm with a spectral resolution of 3 nm. The HSR1 spectral irradiance measurements are compared to nearby collocated spectral radiometers, including two multifilter rotating shadowband radiometers (MFRSRs) and the Shortwave Array Spectroradiometer–Hemispheric (SASHe) radiometer. The Ftotal at 500 nm for the HSR1 compared to the MFRSRs has a mean (relative) difference of 0.01 W m−2 nm−1 (1 %–2 %). The HSR1 mean Fdiffuse at 500 nm is smaller than the MFRSRs' by 0.03–0.04 (10 %) W m−2 nm−1. The HSR1 clear-sky aerosol optical depth (AOD) is also retrieved by considering Langley regressions and compared to collocated instruments such as the Cimel sunphotometer (CSPHOT), MFRSRs, and SASHe. The mean HSR1 AOD at 500 nm is larger than the CSPHOT's by 0.010 (8 %) and larger than the MFRSRs' by 0.007–0.017 (6 %–18 %). In general, good agreement between the HSR1 and other instruments is found in terms of the Ftotal, Fdiffuse, and AODs at 500 nm. The HSR1 quantities are also compared at other wavelengths to the collocated instruments. The comparisons are within ∼ 10 % for the Ftotal and Fdiffuse, except for 940 nm, where there is relatively larger disagreement. The AOD comparisons are within ∼ 10 % at 415 and 440 nm; however, a relatively larger disagreement in the AOD comparison is found for higher wavelengths.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Analysis of the CE-22 Advanced Nozzle Test Facility

This paper presents methods and results of a detailed measurement uncertainty analysis that was performed for the Advanced Nozzle Test Facility, CE-22, located at the NASA Glenn Research Center. Results for the uncertainty in thrust and flow coefficients, in addition to other variables of interest, are provided. Results are presented separately as random uncertainty (characterizing errors inherent to instrument or measurement environment, impacting repeatability), systematic uncertainty (capturing inaccuracies due to measurement process, calibration, installation effects or other sources which may introduce bias), and total combined uncertainty. The statistical methods and engineering judgments used to estimate elemental uncertainties are described. The analysis tool MANTUS (Measurement Analysis Tool for Uncertainty in Systems) was used to quantify instrumentation system uncertainty, and statistical analysis and engineering judgment were used to quantify other random and systematic uncertainty sources. The Monte Carlo method was used to propagate systematic and random elemental uncertainties to determine the uncertainties of various calculated variables of interest.

data quality↗

Global Retrieval of Aerosol Properties from Sources to Sinks By MODIS

Mineral dust and smoke aerosols play an important role in both climate forcing and oceanic productivity throughout the entire year. Due to the relatively short lifetime (a few hours to about a week), the distributions of these airborne particles vary extensively in both space and time. Consequently, satellite observations are needed over both source and sink regions for continuous temporal and spatial sampling of dust and smoke properties. However, despite their importance, the high spatial resolution satellite measurements of these aerosols near their sources have been lacking, In this paper, we will demonstrate the capability of a new satellite algorithm to retrieve aerosol optical thickness and single scattering albedo over bright-reflecting surfaces such as urban areas and deserts. Such retrievals have been difficult to perform using previously available algorithms that use wavelengths from the mid-visible to the near IR because they have trouble separating the aerosol signal from the contribution due to the bright surface reflectance. The new algorithm, called Deep Blue, utilizes blue-wavelength measurements from instruments such as MODIS and SeaWiFS to infer the properties of aerosols, since the surface reflectance over land in the blue part of the spectrum is much lower than for longer wavelength channels. We have validated the satellite retrieved aerosol optical thickness with data from AERONET sunphotometers over land, including desert and semi-desert regions. The comparisons show reasonable agreements between these two. Our results show that the dust plumes lifted from the deserts near India/Pakistan border, and over Afghanistan, and the Arabian Peninsula are often observed by MODIS to be transported along the Indo-Gangetic Basin and mixed with the fine mode pollution particles generated by anthropogenic activities in this region, particularly during the pre-monsoon season (April-May). These new satellite products will allow scientists to determine quantitatively the aerosol properties near sources using high spatial resolution measurements from SeaWiFS and MODIS-like instruments.

Hsu, N. Christina↗

On-Orbit Measurement of the Focal Length of the SNPP VIIRS Instrument

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument is a whiskbroom system with 22 spectral bands split between 16 moderate resolution bands (M-bands), five imagery resolution bands (I-bands) and a panchromatic day-night band. Latitude and Longitude geolocation data are generated for each pixel at the M-band, I-band and day-night band spatial resolutions based upon various instrument parameters including focal length. In this study we measure the focal length of the VIIRS instrument from on-orbit data. This is achieved by simulating VIIRS band I2 using Landsat 8 OLI band 5 utilizing the VIIRS instrument system point spread function (PSF) and geolocation data generated with varying values of focal length. The focal length value that produces the highest spatial correlation between the original and simulated VIIRS data is taken to be the measured instrument focal length.

Image analysis↗

Water Vapor, Temperature, and Ice Particles in Polar Mesosphere as Measured by SABER/TIMED and OSIRIS/Odin Instruments

Although many new details on the properties of mesospheric ice particles that farm Polar Mesospheric Clouds (PMCs) and also cause polar mesospheric summer echoes have been recently revealed, certain aspects of mesospheric ice microphysics and dynamics still remain open. The detailed relation between PMC parameters and properties of their environment, as well as interseasonal and interhemispheric differences and trends in PMC properties that are possibly related to global change, are among those open questions. In this work, mesospheric temperature and water vapor concentration measured by the Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) instrument on board the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) satellite are used to study the properties of PMCs with respect to the surrounding atmosphere. The cloud parameters, namely location, brightness, and altitude, are obtained from the observations made by the Optical Spectrograph and Infrared Imager System (OSIRIS) on the Odin satellite. About a thousand of simultaneous common volume measurements made by SABER and OSIRIS in both hemispheres from 2002 until 2008 are used. The correlation between PMC brightness (and occurrence rate) and temperatures at PMC altitudes and at the mesopause is analysed. The relation between PMC parameters, frost point temperature, and gaseous water vapor content in and below the cloud is also discussed. Interseasonal and interhemispheric differences and trends in the above parameters, as well as in PMC peak altitudes and mesopause altitudes are evaluated.

Feofilov, A. G.↗

Overview of the Solar Ultraviolet Magnetograph Investigation

Traditional magnetographs measure the solar magnetic field at the visible "surface" of the Sun, the photosphere. The Solar Ultraviolet Magnetograph Investigation (SUMI) is a design study for an instrument to measure the solar magnetic field higher in the atmosphere, in the upper chromosphere and in the transition region at the base of the corona. The magnetic pressure at these levels is much stronger than the gas pressure (in contrast to the situation at the photosphere), and so the field is much more dynamic. Observations in this region will significantly improve our understanding of the physical processes driving flares and heating in the Sun's upper atmosphere. The instrument will incorporate new technologies to achieve the polarization efficiencies required to isolate the magnetic lines (Civ at 155nm and MgII at 280nm) to be observed in the UV. We describe the scientific goals, the SUMI baseline design and the optical components that are being developed for a sounding rocket program.

West, Edward A.↗

Temperature Measurement During Polymerization of Bone Cement in Percutaneous Vertebroplasty: An In Vivo Study in Humans

Aim of the study was to 'in vivo' measure temperature, during percutaneous vertebroplasty (PV), within a vertebral body injected with different bone cements. According to the declaration of Helsinki, 22 women (60-80 years; mean, 75 years) with painful osteoporotic vertebral collapse underwent bilateral transpedicular PV on 22 lumbar vertebrae. Two 10-G vertebroplasty needles were introduced into the vertebra under digital fluoroscopy; a 16-G radiofrequency thermoablation needle (Starburst XL; RITA Medical System Inc., USA), carrying five thermocouples, was than coaxially inserted. Eleven different bone cements were injected and temperatures were measured every 30 s until temperatures dropped under 45{sup o}C. After the thermocouple needle was withdrawn, bilateral PV was completed with cement injection through the vertebroplasty needle. Unpaired Student's t-tests, Kruskal-Wallis test, and Wilcoxon signed rank test were used to evaluate significant differences (p < 0.05) in peak temperatures, variations between cements, and clinical outcome. All procedures were completed without complications, achieving good clinical outcomes (p < 0.0001). Regarding average peak temperature, cements were divided into three groups: A (over 60{sup o}C), B (from 50{sup o} to 60{sup o}C), and C (below 50{sup o}C). Peak temperature in Group A (86.7 {+-} 10.7{sup o}C) was significantly higher (p = 0.0172) than that in Groups B (60.5 {+-} 3.7{sup o}C) and C (44.8 {+-} 2.6{sup o}C). The average of all thermocouples showed an extremely significant difference (p = 0.0002) between groups. None of the tested cements maintained a temperature {>=}45{sup o}C for more than 30 min. These data suggest that back-pain improvement is obtained not by thermal necrosis but by mechanical consolidation only. The relative necrotic thermal effect in vertebral metastases seems to confirm that analgesia must be considered the main intent of PV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spun optical fibres: A helical structure of linear birefringence or circular birefringence?

An experiment has been proposed, theoretically substantiated and accomplished which has provided conclusive evidence in favour of one of two models for the behaviour of polarised light in optical fibres fabricated by spinning preforms with a high built-in linear birefringence (spun fibres): a helical structure of the built-in linear birefringence axes and circular birefringence. The experiment, carried out with a reflective fibreoptic dual-polarisation interferometer, has shown that the behaviour of polarisation states in spun fibres can be understood in terms of a helical structure of the built-in linear birefringence axes. (optical fibres)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model mismatch analysis and compensation for modal phase measuring deflectometry

The correspondence residuals due to the discrepancy between the reality and the shape model in use are analyzed for the modal phase measuring deflectometry. Slope residuals are calculated from these discrepancies between the modal estimation and practical acquisition. Since the shape mismatch mainly occurs locally, zonal integration methods which are good at dealing with local variations are used to reconstruct the height residual for compensation. Finally, results of both simulation and experiment indicate the proposed height compensation method is effective, which can be used as a post-complement for the modal phase measuring deflectometry.

47 OTHER INSTRUMENTATION↗

Subsatellite measurements of the lunar magnetic field

The Apollo 15 subsatellite magnetometer data have been used to map the lunar magnetic field over a narrow band of the lunar surface. Within this band the magnetic field is generally stronger and more variable over the farside highlands than the nearside maria. The correspondence between the strong variable lunar field regions and the source regions for limb compressions suggests that limb compressions arise as the result of the deflection of the solar wind just upstream of the terminator by the lunar magnetic field. Using this apparent relationship between field strength and limb compression source regions, it is deduced that the field strength in the northern farside highlands is not as strong as in the southern hemisphere at similar longitudes. Simultaneous measurements of the interplanetary magnetic field obtained by Explorer 35 and the Apollo 15 subsatellite above the dayside hemisphere are essentially identical. Thus, both instruments are measuring the undisturbed interplanetary field.

Russell, C. T.↗