Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Functionalized Hydroperoxide Formation from the Reaction of Methacrolein-Oxide, an Isoprene-Derived Criegee Intermediate, with Formic Acid: Experiment and Theory

Methacrolein oxide (MACR-oxide) is a four-carbon, resonance-stabilized Criegee intermediate produced from isoprene ozonolysis, yet its reactivity is not well understood. This study identifies the functionalized hydroperoxide species, 1-hydroperoxy-2-methylallyl formate (HPMAF), generated from the reaction of MACR-oxide with formic acid using multiplexed photoionization mass spectrometry (MPIMS, 298 K = 25 °C, 10 torr = 13.3 hPa). Electronic structure calculations indicate the reaction proceeds via an energetically favorable 1,4-addition mechanism. The formation of HPMAF is observed by the rapid appearance of a fragment ion at m/z 99, consistent with the proposed mechanism and characteristic loss of HO2 upon photoionization of functional hydroperoxides. The identification of HPMAF is confirmed by comparison of the appearance energy of the fragment ion with theoretical predictions of its photoionization threshold. The results are compared to analogous studies on the reaction of formic acid with methyl vinyl ketone oxide (MVK-oxide), the other four-carbon Criegee intermediate in isoprene ozonolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Targeted Quantification of Protein Phosphorylation and Its Contributions towards Mathematical Modeling of Signaling Pathways

Post-translational modifications (PTMs) are key regulatory mechanisms that can control protein function. Of these, phosphorylation is the most common and widely studied. Because of its importance in regulating cell signaling, precise and accurate measurements of protein phosphorylation across wide dynamic ranges are crucial to understanding how signaling pathways function. Although immunological assays are commonly used to detect phosphoproteins, their lack of sensitivity, specificity, and selectivity often make them unreliable for quantitative measurements of complex biological samples. Recent advances in Mass Spectrometry (MS)-based targeted proteomics have made it a more useful approach than immunoassays for studying the dynamics of protein phosphorylation. Selected reaction monitoring (SRM)—also known as multiple reaction monitoring (MRM)—and parallel reaction monitoring (PRM) can quantify relative and absolute abundances of protein phosphorylation in multiplexed fashions targeting specific pathways. In addition, the refinement of these tools by enrichment and fractionation strategies has improved measurement of phosphorylation of low-abundance proteins. The quantitative data generated are particularly useful for building and parameterizing mathematical models of complex phospho-signaling pathways. Potentially, these models can provide a framework for linking analytical measurements of clinical samples to better diagnosis and treatment of disease.

mathematical modeling↗

A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber

This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.

47 OTHER INSTRUMENTATION↗

Development and Assessment of SNP Genotyping Arrays for Citrus and Its Close Relatives

Rapid advancements in technologies provide various tools to analyze fruit crop genomes to better understand genetic diversity and relationships and aid in breeding. Genome-wide single nucleotide polymorphism (SNP) genotyping arrays offer highly multiplexed assays at a relatively low cost per data point. We report the development and validation of 1.4M SNP Axiom® Citrus HD Genotyping Array (Citrus 15AX 1 and Citrus 15AX 2) and 58K SNP Axiom® Citrus Genotyping Arrays for Citrus and close relatives. SNPs represented were chosen from a citrus variant discovery panel consisting of 41 diverse whole-genome re-sequenced accessions of Citrus and close relatives, including eight progenitor citrus species. SNPs chosen mainly target putative genic regions of the genome and are accurately called in both Citrus and its closely related genera while providing good coverage of the nuclear and chloroplast genomes. Reproducibility of the arrays was nearly 100%, with a large majority of the SNPs classified as the most stringent class of markers, “PolyHighResolution” (PHR) polymorphisms. Concordance between SNP calls in sequence data and array data average 98%. Phylogenies generated with array data were similar to those with comparable sequence data and little affected by 3 to 5% genotyping error. Both arrays are publicly available.

59 BASIC BIOLOGICAL SCIENCES↗

Integrating Radio-Over-Fiber Communication System and BOTDR Sensor System

In this paper, we propose and experimentally demonstrate for the first time, the integration of a radio-over-fiber (RoF) communication system and a Brillouin optical time-domain reflectometry (BOTDR) distributed sensor system using a single optical fiber link. In this proof-of-concept integrated system, the communication system is composed of three modulation formats of quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM) and 64-QAM, which are modulated onto an orthogonal frequency division multiplexing (OFDM) signal. Whereas, the BOTDR sensor system is used for strain and/or temperature monitoring over the fiber distance with a spatial resolution of 5 m using a 25 km single-mode silica fiber. The error vector magnitude (EVM) is analyzed in three modulation formats in the presence of various BOTDR input pump powers. Using QPSK modulation, optimized 18 dBm sensing and 10 dBm data power, the measured EVM values with and without bandpass filter are 3.5% and 14.5%, respectively. The proposed system demonstrates a low temperature measurement error (±0.49 °C at the end of 25 km) and acceptable EVM values, which were within the 3GPP requirements. The proposed integrated system can be effectively applied for practical applications, which significantly reduces the fiber infrastructure cost by effective usage of a single optical fiber link.

42 ENGINEERING↗

An Adaptable, Portable Microarray Reader for Biodetection

We have developed an inexpensive portable microarray reader that can be applied to standard microscope slide-based arrays and other array formats printed on chemically modified surfaces. Measuring only 19 cm in length, the imaging device is portable and may be applicable to both triage and clinical settings. For multiplexing and adaptability purposes, it can be modified to work with multiple excitation/emission wavelengths. Our device is shown to be comparable to a commercial laser scanner when detecting both streptavidin-biotin and antibody interactions. This paper presents the development and characterization of a handheld microarray imager and directly compares it with a commercial scanner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Lactobacilli Phage Endolysins and Their Functional Domains–Potential Live Biotherapeutic Testing Reagents

Phage endolysin-specific binding characteristics and killing activity support their potential use in biotechnological applications, including potency and purity testing of live biotherapeutic products (LBPs). LBPs contain live organisms, such as lactic acid bacteria (LAB), and are intended for use as drugs. Our approach uses the endolysin cell wall binding domains (CBD) for LBP potency assays and the endolysin killing activity for purity assays. CBDs of the following five lactobacilli phage lysins were characterized: CL1, Jlb1, Lj965, LL-H, and ΦJB. They exhibited different bindings to 27 LAB strains and were found to bind peptidoglycan or surface polymers. Flow cytometry based on CBD binding was used to enumerate viable counts of two strains in the mixture. CL1-lys, jlb1-lys, and ΦJB-lys and their enzymatic domains (EADs) exhibited cell wall digestive activity and lytic activity against LAB. Jlb1-EAD and ΦJB-EAD were more sensitive than their respective hololysins to buffer pH and NaCl changes. The ΦJB-EAD exhibited stronger lytic activity than ΦJB-lys, possibly due to ΦJB-CBD-mediated sequestration of ΦJB-lys by cell debris. CBD multiplex assays indicate that these proteins may be useful LBP potency reagents, and the lytic activity suggests that CL1-lys, jlb1-lys, and ΦJB-lys and their EADs are good candidates for LBP purity reagent development.

60 APPLIED LIFE SCIENCES↗

Full-Length ASFV B646L Gene Sequencing by Nanopore Offers a Simple and Rapid Approach for Identifying ASFV Genotypes

African swine fever (ASF) is an acute, highly hemorrhagic viral disease in domestic pigs and wild boars. The disease is caused by African swine fever virus, a double stranded DNA virus of the Asfarviridae family. ASF can be classified into 25 different genotypes, based on a 478 bp fragment corresponding to the C-terminal sequence of the B646L gene, which is highly conserved among strains and encodes the major capsid protein p72. The C-terminal end of p72 has been used as a PCR target for quick diagnosis of ASF, and its characterization remains the first approach for epidemiological tracking and identification of the origin of ASF in outbreak investigations. Recently, a new classification of ASF, based on the complete sequence of p72, reduced the 25 genotypes into only six genotypes; therefore, it is necessary to have the capability to sequence the full-length B646L gene (p72) in a rapid manner for quick genotype characterization. Here, we evaluate the use of an amplicon approach targeting the whole B646L gene, coupled with nanopore sequencing in a multiplex format using Flongle flow cells, as an easy, low cost, and rapid method for the characterization and genotyping of ASF in real-time.

Virology↗

SDSS-V Algorithms: Fast, Collision-free Trajectory Planning for Heavily Overlapping Robotic Fiber Positioners

Robotic fiber positioner (RFP) arrays are becoming heavily adopted in wide-field massively multiplexed spectroscopic survey instruments. RFP arrays decrease nightly operational overheads through rapid reconfiguration between fields and exposures. In comparison to similar instruments, SDSS-V has selected a very dense RFP packing scheme where any point in a field is typically accessible to three or more robots. This design provides flexibility in target assignment. However, the task of collisionless trajectory planning is especially challenging. We present two multiagent distributed control strategies that are highly efficient and computationally inexpensive for determining collision-free paths for RFPs in heavily overlapping workspaces. We demonstrate that a reconfiguration path between two arbitrary robot configurations can be efficiently found if a “folded” state, in which all robot arms are retracted and aligned in a lattice-like orientation, is inserted between the initial and final states. Although developed for SDSS-V, the approach we describe is generic and thus applicable to a wide range of RFP designs and layouts. Robotic fiber positioner technology continues to advance rapidly, and in the near future ultra-densely packed RFP designs may be feasible. Our algorithms are especially capable in routing paths in very crowded environments, where we see efficient results even in regimes significantly more crowded than the SDSS-V RFP design.

42 ENGINEERING↗

The Stability of Fiber Spectrographs in the Faint-source Regime

The use of optical fibers in astronomical instrumentation offers high-multiplex and light-gathering flexibility. However, with most previous fiber spectrographs optimized for large fields of view on modest-aperture telescopes, the performance of fibers in the context of faint targets on large telescopes remains largely untested. In this paper, we evaluate aspects of fiber stability, especially as they apply in the context of precision sky subtraction of faint sources at modest spectral resolution ($R$ ~ 3000). After introducing a framework for describing potential systematic errors, we use publicly available data from existing instruments, including instrumentation used by the fourth-generation Sloan Digital Sky Survey’s MaNGA project (MaNGA: Mapping Nearby Galaxies at Apache Point Observatory) and the Very Large Telescope’s FLAMES: Fiber Large Array Multi Element Spectrograph. We isolate sources of fiber systematics and estimate the observed amplitude of persistent residuals as well as stochastic noise contributions resulting from changing fiber stresses. Comparing these levels against their impact on various sky subtraction schemes demonstrates that 0.1% precision sky subtraction with fiber instruments is possible. As a demonstration, we show that the MaNGA instrument can deliver 0.2% residuals on bright near-IR sky lines with nonlocal sky subtraction, if pseudo-slit limitations are addressed by allocating 50% of its fibers to sky. We further highlight recently published deep exposures that achieved a 1$σ$ background level of 27.6 AB per square arc second, equivalent to a precision of 0.2% of the sky background continuum.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring Fiber Positioning Accuracy and Throughput with Fiber Dithering for the Dark Energy Spectroscopic Instrument

Highly multiplexed, fiber-fed spectroscopy is enabling surveys of millions of stars and galaxies. The performance of these surveys depends on accurately positioning fibers in the focal plane to capture target light. We describe a technique to measure the positioning accuracy of fibers by dithering fibers slightly around their ideal locations. This approach also enables measurement of the total system throughput and point-spread function delivered to the focal plane. We then apply this technique to observations from the Dark Energy Survey Instrument (DESI), and demonstrate that DESI positions fibers to within 0farcs08 of their targets (5% of a fiber diameter) and achieves a system throughput within about 7% of expectations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting Turbulence-induced Errors in Fiber Positioning for the Dark Energy Spectroscopic Instrument

Highly multiplexed, robotic, fiber-fed spectroscopic surveys are observing tens of millions of stars and galaxies. For many systems, accurate positioning relies on imaging the fibers in the focal plane and feeding that information back to the robotic positioners to correct their positions. Inhomogeneities and turbulence in the air between the focal plane and the imaging camera can affect the measured positions of fibers, limiting the accuracy with which fibers can be placed on targets. For the Dark Energy Spectroscopic Instrument, we dramatically reduced the effect of turbulence on measurements of positioner locations in the focal plane by taking advantage of stationary positioners and the correlation function of the turbulence. We were able to reduce positioning errors from 7.3 to 3.5 μm, speeding the survey by 1.6% under typical conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Spectroscopy with DESI for Photometric Redshift Training and Calibration

Deep spectroscopic samples can improve photometric redshift (photo-z) estimates and reduce uncertainties on redshift distributions. Such improvements can increase the cosmological constraining power of large imaging-based experiments such as the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and mitigate what may be a limiting systematic effect. We present results from the “DESI-Deep pilot” program, which was designed to assess the capability of the Dark Energy Spectroscopic Instrument (DESI) on the 4m Mayall telescope to measure redshifts of galaxies as faint as expected lensing samples for early LSST data (m i ≤ 24.5). We find that DESI is remarkably efficient at this task, with redshift success rates comparable to the results of observations from 10 m class telescopes with only ∼2 × longer integration time (rather than ∼8 × longer as would be expected from aperture-area scaling), while simultaneously achieving ∼30 times larger multiplexing. We also find that the signal-to-noise ratio of the spectra scales as expected for background-limited observations even for the longest exposure times (∼7 hr) and faintest targets in the program. These results demonstrate that DESI could provide the definitive redshift sample for the early years of LSST with a modest investment of observing time. Based upon the results of this program, we provide updated predictions for the time required to collect benchmark samples for photo-z training and calibration using a variety of spectroscopic facilities. Finally, we describe a potential “DESI-Deep” survey designed to train and calibrate photo-z’s for imaging experiments, and provide forecasts of its impact on cosmological inference.

Dey, Biprateep [University of Toronto; University ↗

The Complete Calibration of the Color–Redshift Relation (C3R2) Survey: Survey Overview and Data Release 1

A key goal of the Stage IV dark energy experiments Euclid , LSST, and WFIRST is to measure the growth of structure with cosmic time from weak lensing analysis over large regions of the sky. Weak lensing cosmology will be challenging: in addition to highly accurate galaxy shape measurements, statistically robust and accurate photometric redshift (photo- z ) estimates for billions of faint galaxies will be needed in order to reconstruct the three-dimensional matter distribution. Here we present an overview of and initial results from the Complete Calibration of the Color–Redshift Relation (C3R2) survey, which is designed specifically to calibrate the empirical galaxy color–redshift relation to the Euclid depth. These redshifts will also be important for the calibrations of LSST and WFIRST . The C3R2 survey is obtaining multiplexed observations with Keck (DEIMOS, LRIS, and MOSFIRE), the Gran Telescopio Canarias (GTC; OSIRIS), and the Very Large Telescope (VLT; FORS2 and KMOS) of a targeted sample of galaxies that are most important for the redshift calibration. We focus spectroscopic efforts on undersampled regions of galaxy color space identified in previous work in order to minimize the number of spectroscopic redshifts needed to map the color–redshift relation to the required accuracy. We present the C3R2 survey strategy and initial results, including the 1283 high-confidence redshifts obtained in the 2016A semester and released as Data Release 1.

79 ASTRONOMY AND ASTROPHYSICS↗

Comprehensive Measurements of the Volume-phase Holographic Gratings for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will be employed on the Mayall 4 m Telescope to study the expansion history of the universe. In the era of massively multiplexed fiber-fed spectrographs, DESI will push the boundaries of fiber spectroscopy with a design capable of taking 5000 simultaneous spectra over 360 to 980 nm. The instrument utilizes a suite of three-channel spectrographs, where volume-phase holographic (VPH) gratings provide dispersions. Thirty-six VPH gratings were produced and their performances were evaluated at the Lawrence Berkeley National Laboratory. We present the design and the evaluation tests for the production run of the VPH gratings, verifying the incidence angle, area-weighted efficiency, and wavefront errors (WFEs). We also present the specialized test set-up developed on-site to assess the grating performances. Measurements of the VPH gratings show high consistency in area-weighted efficiency to within an rms of 2% for the red and near-infrared and 6.2% for the blue gratings. Measured WFEs also showed high consistency per bandpass. Comprehensive evaluations show that the VPH gratings meet DESI performance requirements and have been approved for integration.

79 ASTRONOMY AND ASTROPHYSICS↗

The Stars of the HETDEX Survey. I. Radial Velocities and Metal-poor Stars from Low-resolution Stellar Spectra

The Hobby–Eberly Telescope Dark Energy Experiment (HETDEX) is an unbiased, massively multiplexed spectroscopic survey, designed to measure the expansion history of the universe through low-resolution ( R ~ 750) spectra of Ly α emitters. In its search for these galaxies, HETDEX will also observe a few times 10 5 stars. In this paper, we present the first stellar value-added catalog within the internal second data release of the HETDEX Survey (HDR2). The new catalog contains 120,571 low-resolution spectra for 98,736 unique stars between 10 < G < 22 spread across the HETDEX footprint at relatively high ( b ~ 60°) Galactic latitudes. With these spectra, we measure radial velocities (RVs) for ~42,000 unique FGK-type stars in the catalog and show that the HETDEX spectra are sufficient to constrain these RVs with a 1 σ precision of 28.0 km s -1 and bias of 3.5 km s -1 with respect to the Large Sky Area Multi-Object Fibre Spectroscopic Telescope surveys and 1 σ precision of 27.5 km s -1 and bias of 14.0 km s -1 compared to the Sloan Extension for Galactic Understanding and Exploration survey. Since these RVs are for faint ( G ≥ 16) stars, they will be complementary to Gaia. Using t-Distributed Stochastic Neighbor Embedding (tSNE), we also demonstrate that the HETDEX spectra can be used to determine a star’s T eff , and log g and its [Fe/H]. With the tSNE projection of the FGK-type stars with HETDEX spectra we also identify 416 new candidate metal-poor ([Fe/H] < -1 dex) stars for future study. These encouraging results illustrate the utility of future low-resolution stellar spectroscopic surveys.

Astronomy & Astrophysics↗

Probing the Environment around GW170817 with DESI: Insights on Galaxy Group Peculiar Velocities for Standard Siren Measurements

We present a new measurement of the Hubble constant, H 0 , following the gravitational-wave event GW170817 and Dark Energy Spectroscopic Instrument (DESI) observations. A standard siren measurement with a nearby (luminosity distance ∼40 Mpc) event such as GW170817 is typically sensitive to the peculiar motion of the host galaxy owing to local dynamics. Previous measurements from this event have taken advantage of peculiar velocity measurements of nearby galaxies, including a handful of objects in the galaxy group that the host of the event, NGC 4993, has been associated with. Still, the group’s properties and NGC 4993’s membership were debated. We present DESI observations of thousands of galaxies in the vicinity of NGC 4993, resulting in 39 group galaxies and a fivefold increase in galaxies compared to previous observations, with many contributing to a peculiar velocity measurement. Examining the local dynamics, our observations support the presence of a galaxy group of which NGC 4993 is a part with a halo mass of order ∼10 13 M ⊙ . Using peculiar velocity measurements from our fundamental plane galaxy observations, we find $H_0 = 70.9^{+6.4}_{-8.5}$ km s −1 Mpc −1 . In addition, using a peculiar velocity measurement for NGC 4993 from surface brightness fluctuations in Cosmicflows-4, we find $H_0 = 73.4^{+3.3}_{-3.9}$ km s −1 Mpc −1 . We study the impact of different galaxy selection criteria on the determination of the peculiar velocity and, in turn, on the H 0 measurement. Our results demonstrate the value of multiplexed spectroscopic observations for probing the local environments of gravitational-wave events used in standard siren measurements.

Amsellem, A. J. [Carnegie Mellon University, Pitts↗

The EBEX Balloon-borne Experiment—Optics, Receiver, and Polarimetry

The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background (CMB) polarimeter that flew over Antarctica in 2012. We describe the experiment's optical system, receiver, and polarimetric method and discuss their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make effective use of limited mass and space, we created a 115 cm 2 sr high-throughput optical system that had two ambient temperature mirrors and four antireflection-coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). This is the first use of an SMB in astrophysics. Rotation stability was 0.45% over a period of 10 hr, and angular position accuracy was 0$^{°}_{.}$1. The measured modulation efficiency was above 90% for all bands. To our knowledge the 109% fractional bandwidth of the AHWP was the broadest implemented to date. The receiver, composed of one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K, performed according to specifications, giving focal plane temperature stability with a fluctuation power spectrum that had a 1/f knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters, including high-throughput optical systems, and large arrays of transition edge sensor bolometric detectors with multiplexed readouts.

polarization↗