Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission Reaction Event Yield Algorithm FREYA 2.0.2

The purpose of this paper is to present the main differences between FREYA versions 1.0 and 2.0.2. FREYA (Fission Reaction Event Yield Algorithm) is a fission event generator which models complete fission events. As such, it automatically includes fluctuations as well as correlations between observables, resulting from conservation of energy and momentum. The main differences between the two versions are: additional fissionable isotopes, angular momentum conservation, Giant Dipole Resonance form factor for the statistical emission of photons, improved treatment of fission photon emission using RIPL database, and dependence on the incident neutron direction. FREYA 2.0.2 has been integrated into the LLNL Fission Library 2.0.2, which has itself been integrated into MCNP6.2, TRIPOLI-4.10, and can be called from Geant4.10.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the competition between Tl + and Ce 3+ scintillation in Tl2LiYCl6:Ce, an elpasolite scintillator

Li-containing elpasolite scintillators are currently investigated for their ability to detect both thermal neutrons and gamma photons with a single inorganic crystal. The scintillation is typically triggered by using an activator such as Ce. However, when Tl, also a luminescent ion, is present in the matrix, competition between the two centers Tl and Ce can occur. In this study, we are using Ce doped Tl 2 LiYCl 6 to investigate this competition. To this end, the Ce (which substitutes Y) concentration is varied from 0 to 1 in the Tl 2 LiY 1-x CexCl 6 composition. In the low concentration range in which Ce remains a dopant, the photo- and radioluminescence spectra show that the scintillation of Tl 2 LiYCl 6 :Ce is mostly dominated by recombination on intrinsic luminescent centers. For cerium concentrations higher than x = 0.02, very different emissions can be easily distinguished from the photo- and radioluminescence of undoped and low Ce doped Tl 2 LiYCl 6 crystals. These emissions are attributed to the formation of a second phase Tl 2 CeCl 5 , identified by X-ray diffraction. We conclude that the intrinsic luminescence related to Tl dominates the scintillation in the range of concentration for which Ce does substitute on the Y-site.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Impact of Nuclear Data Uncertainties in Ultra-high Resolution Gamma Spectroscopy for Isotopic Analysis Using Approximate Bayesian Computation

High purity germanium (HPGe) currently provides the highest readily available resolution gamma detection for a broad range of radiation measurements, but microcalorimetry is a developing option that has considerably higher resolution even than HPGe. Superior microcalorimetry resolution offers the potential to better distinguish closely spaced X-rays and gamma-rays, a common challenge for the low energy spectral region near 100 keV from special nuclear materials, and the higher signal-to-background ratio also confers an advantage in detection limit. As microcalorimetry continues to develop, it is timely to assess the impact of uncertainties in detector and item response functions and in basic nuclear data, such as branching ratios and half-lives, used to interpret spectra in terms of the contributory radioactive isotopes. We illustrate that a new inference option known as approximate Bayesian computation (ABC) is effective and convenient both for isotopic inference and for uncertainty quantification for microcalorimetry. The ABC approach opens a pathway to new and more powerful implementations for practical applications than currently available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Passive Neutron Detection for Interdiction of Nuclear Material at Borders

Radiation portal monitor systems based upon polyvinyl toluene scintillator gamma-ray detectors and pressurized 3He-based neutron detector tubes have been deployed to detect illicit trafficking in radioactive materials at international border crossings. This paper reviews the neutron detection requirements and capabilities of passive, as opposed to active interrogation, detection systems used for screening of high-volume commerce for illicit sources of radiation at international border crossings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from a Prototype MAPS Sensor Telescope and Readout Systemwith Zero Suppression for the Heavy Flavor Tracker at STAR

We describe a three Mimostar-2 Monolithic Active PixelSensor (MAPS) sensor telescope prototype with an accompanying readoutsystem incorporating on-the-fly data sparsification. The system has beencharacterized and we report on the measured performance of the sensortelescope and readout system in beam tests conducted both at the AdvancedLight Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) and inthe STAR experiment at the Relativistic Heavy Ion Collider (RHIC). Thiseffort is part of the development and prototyping work that will lead toa vertex detector for the STAR experiment.

43 PARTICLE ACCELERATORS↗

Gamma-ray coincidence and fast-timing measurements using LaBr{sub 3}(Ce) detectors and gammasphere

The performance of new scintillator detectors based on LaBr{sub 3}(Ce) technology was evaluated in conjunction with the Gammasphere spectrometer. Specifically, the lifetimes of states between 50 ps and 1 ns, populated in the decay of the {sup 177m}Lu isomeric state (T{sub 1/2} = 160 d), have been measured. Even though the decay scheme is rather complex, it is possible to perform precise measurements because of the superior energy resolution of the LaBr{sub 3}(Ce) detectors, compared to that of BaF{sub 2} scintillators, when used in combination with the power of the Gammasphere array to isolate a specific {gamma} cascade

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of energy resolution on the extraction of information content from gamma-ray spectra

Rapid unambiguous identification of illicit radioactive materials is a matter of international concern that has yet to be fully attained. This is particularly true for shielded fissile materials in the presence of background radiation and routinely encountered benign radionuclides. Here, we present a systematic treatment of the effect of detector resolution on the identification of nuclides in simple and complex shielded γ-ray spectra. Case studies of some problematic spectra with 1000 counts suggest that, at moderate count rates, near-unambiguous identification (<1% probability of misidentification) of potential fissile sources requires a detector with an energy resolution of at least 1–2% at 662 keV. While somewhat limited in scope, the study establishes a quantitative basis for the comparative evaluation of detectors of comparable efficiency.

42 ENGINEERING↗

Neutron light output response and resolution functions in EJ-309 liquid scintillation detectors

Here, the neutron light output response functions and detector resolution functions were measured at Ohio University's tandem Van de Graaff generator for three cylindrical EJ-309 liquid scintillator cells, having dimensions 12.7(circle divide)-by-12.7, 7.6-by-7.6, and 7.6-by-5.1 cm. A 7.44 MeV deuteron beam was used on an Al-27 target generating a continuous spectrum over the energy range from a few hundred keV to over 10 MeV. The light output response functions are determined using an exponential fit. Detector resolution functions are obtained for the 12.7-by-12.7 and 7.6-by-7.6 cm detectors. It is demonstrated that the dependence on detector size is important for the light output response functions, but not to the same extent for the resolution function, even when photomultiplier tubes, detector material, and other detector characteristics are carefully matched.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scaler-based data acquisition system for measuring parity-violating asymmetry in deep inelastic scattering

An experiment that measured the parity violating asymmetries in deep inelastic scattering was completed at the Thomas Jefferson National Accelerator Facility in experimental Hall A. From these asymmetries, a combination of the quark weak axial charge could be extracted with a factor of five improvement in precision over world data. To achieve this, asymmetries at the 10^-4 level needed to be measured at event rates up to 500 kHz and the high pion background typical to deep inelastic scattering experiments needed to be rejected efficiently. A specialized data acquisition (DAQ) system with intrinsic particle identification (PID) was successfully developed and used: The pion contamination in the electron samples was controlled at the order of 2 × 10^-4 or below with an electron efficiency of higher than 91% throughout the production period of the experiment, the systematic uncertainty in the measured asymmetry due to DAQ deadtime was below 0.2%, and the statistical quality of the asymmetry measurement agreed with the Gaussian distribution to over five orders of magnitudes. The DAQ system is presented here with an emphasis on its design scheme, the achieved PID performance, deadtime effect and the capability of measuring small asymmetries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron response characterization for an EJ299-33 plastic scintillation detector

Organic scintillation detectors have shown promise as neutron detectors for characterizing special nuclear materials in various arms-control and homeland security applications. Recent advances have yielded a new plastic scintillator - EJ299-33 - with pulse-shape-discrimination (PSD) capability. Plastic scintillators would have a much expanded range of deployment relative to liquids and crystals. Here in this paper, we present a full characterization of pulse height response to fission-energy neutrons for an EJ299-33 detector with 7.62-by-7.62-cm cylindrical active volume, and compare with an EJ309 liquid scintillator in the same assembly. Scintillation light output relations, energy resolutions, and response matrices are presented for both detectors. A Continuous spectrum neutron source, obtained via the bombardment of 27 Al with 7.44-MeV deuterons at the Edwards Accelerator Facility at Ohio University, was used for the measurement. A new procedure for evaluating and comparing PSD performance is presented which accounts for the effect of the light output relation on the ability to detect low energy neutrons. The EJ299-33 is shown to have considerable deficit in matrix condition, and in PSD figure of merit when compared to EJ309, especially when neutron energy is taken into account. Furthermore the EJ299 is likely to bring a modest PSD capability into a array of held applications that are not accessible to liquids or crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of position-sensitive time-of-flight spectrometer for fission fragment research

A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.

2E-2v↗

Laboratory studies on the removal of radon-born lead from KamLAND's organic liquid scintillator

We studied the removal of radioactivity from liquid scintillator in preparation of a low background phase of KamLAND. We describe the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. Lastly, we report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon daughters from liquid scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an advanced antineutrino detector for reactor monitoring

We present the development of a compact antineutrino detector for the purpose of nuclear reactor monitoring, improving upon a previously successful design. Our paper will describe the design improvements of the detector which increases the antineutrino detection efficiency threefold over the previous effort. There are two main design improvements over previous generations of detectors for nuclear reactor monitoring: dual-ended optical readout and single volume detection mass. The dual-ended optical readout eliminates the need for fiducialization and increases the uniformity of the detector's optical response. The containment of the detection mass in a single active volume provides more target mass per detector footprint, a key design criteria for operating within a nuclear power plant. This technology could allow for real-time monitoring of the evolution of a nuclear reactor core, independent of reactor operator declarations of fuel inventories, and may be of interest to the safeguards community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bubble chambers for experiments in nuclear astrophysics

A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning temperatures are dominated by radiative captures, in this experimental scheme we measure the time reversed processes. Such photodisintegrations allow us to compute the radiative capture cross sections when transitions to excited states of the reaction products are negligible. Due to the transformation of phase space, the photodisintegration cross-sections are up to two orders of magnitude higher. The main advantage of the new target-detector system is a density several orders of magnitude higher than conventional gas targets. Also, the detector is virtually insensitive to the gamma-ray beam itself, thus allowing us to detect only the products of the nuclear reaction of interest. The development and the operation as well as the advantages and disadvantages of the bubble chamber are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗