Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Using the {delta}{sub 3} statistic to test for missed levels in mixed sequence neutron resonance data

The {delta}{sub 3}(L) statistic is studied as a tool to detect missing levels in the neutron resonance data where two sequences are present. These systems are problematic because there is no level repulsion, and the resonances can be too close to resolve. {delta}{sub 3}(L) is a measure of the fluctuations in the number of levels in an interval of length L on the energy axis. The method used is tested on ensembles of mixed Gaussian orthogonal ensemble spectra, with a known fraction of levels (x%) randomly depleted, and can accurately return x. The accuracy of the method as a function of spectrum size is established. The method is used on neutron resonance data for 11 isotopes with either s-wave neutrons on odd-A isotopes, or p-wave neutrons on even-A isotopes. The method compares favorably with a maximum likelihood method applied to the level spacing distribution. Nuclear data ensembles were made from 20 isotopes in total, and their {delta}{sub 3}(L) statistics are discussed in the context of random matrix theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity and uncertainty in the effective delayed neutron fraction ({beta}{sub eff})

Precise knowledge of effective delayed neutron fraction ({beta}{sub eff}) and of the corresponding uncertainty is important for reactor safety analysis. The interest in developing the methodology for estimating the uncertainty in {beta}{sub eff} was expressed in the scope of the UAM project of the OECD/NEA. A novel approach for the calculation of the nuclear data sensitivity and uncertainty of the effective delayed neutron fraction is proposed, based on the linear perturbation theory. The method allows the detailed analysis of components of {beta}{sub eff} uncertainty. The procedure was implemented in the SUSD3D sensitivity and uncertainty code applied to several fast neutron benchmark experiments from the ICSBEP and IRPhE databases. According to the JENDL-4 covariance matrices and taking into account the uncertainty in the cross sections and in the prompt and delayed fission spectra the total uncertainty in {beta}eff was found to be of the order of {approx}2 to {approx}3.5 % for the studied fast experiments. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IMPROVED COMPUTATIONAL NEUTRONICS METHODS AND VALIDATION PROTOCOLS FOR THE ADVANCED TEST REACTOR

The Idaho National Laboratory (INL) is in the process of modernizing the various reactor physics modeling and simulation tools used to support operation and safety assurance of the Advanced Test Reactor (ATR). Key accomplishments so far have encompassed both computational as well as experimental work. A new suite of stochastic and deterministic transport theory based reactor physics codes and their supporting nuclear data libraries (HELIOS, KENO6/SCALE, NEWT/SCALE, ATTILA, and an extended implementation of MCNP5) has been installed at the INL. Corresponding models of the ATR and ATRC are now operational with all five codes, demonstrating the basic feasibility of the new code packages for their intended purpose. Of particular importance, a set of as-run core depletion HELIOS calculations for all ATR cycles since August 2009 was successfully completed during 2011. This demonstration supported a decision late in the year to proceed with the phased incorporation of the HELIOS methodology into the ATR fuel cycle management process beginning in 2012. On the experimental side of the project, new hardware was fabricated, measurement protocols were finalized, and the first four of six planned physics code validation experiments based on neutron activation spectrometry were conducted at the ATRC facility. Data analysis for the first three experiments, focused on characterization of the neutron spectrum in one of the ATR flux traps, has been completed. The six experiments will ultimately form the basis for a flexible, easily-repeatable ATR physics code validation protocol that is consistent with applicable ASTM standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New developments and prospects on COSI, the simulation software for fuel cycle analysis

COSI, software developed by the Nuclear Energy Direction of the CEA, is a code simulating a pool of nuclear power plants with its associated fuel cycle facilities. This code has been designed to study various short, medium and long term options for the introduction of various types of nuclear reactors and for the use of associated nuclear materials. In the frame of the French Act for waste management, scenario studies are carried out with COSI, to compare different options of evolution of the French reactor fleet and options of partitioning and transmutation of plutonium and minor actinides. Those studies aim in particular at evaluating the sustainability of Sodium cooled Fast Reactors (SFR) deployment and the possibility to transmute minor actinides. The COSI6 version is a completely renewed software released in 2006. COSI6 is now coupled with the last version of CESAR (CESAR5.3 based on JEFF3.1.1 nuclear data) allowing the calculations on irradiated fuel with 200 fission products and 100 heavy nuclides. A new release is planned in 2013, including in particular the coupling with a recommended database of reactors. An exercise of validation of COSI6, carried out on the French PWR historic nuclear fleet, has been performed. During this exercise quantities like cumulative natural uranium consumption, or cumulative depleted uranium, or UOX/MOX spent fuel storage, or stocks of reprocessed uranium, or plutonium content in fresh MOX fuel, or the annual production of high level waste, have been computed by COSI6 and compared to industrial data. The results have allowed us to validate the essential phases of the fuel cycle computation, and reinforces the credibility of the results provided by the code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TREAT Multi-SERTTA Neutronics Design and Analysis Support

Transient Reactor Experiment Test (TREAT) experiment vehicle design is necessary in preparation for TREAT facility restart and the resumption of transient testing to support current Accident Tolerant Fuel (ATF) characterization needs and future fuels testing requirements. Currently the most mature vehicle design is the Multi-SERTTA (Static Environments Rodlet Transient Test Apparatuses), which can accommodate up to four concurrent rodlet-sized specimens under separate environmental conditions. Development of this robust test vehicle design requires neutronics analyses to support optimization of the Power Coupling Factor (PCF) to efficiently maximize energy generation in the fuel rodlets and to perform essential safety analyses. Current Multi-SERTTA calculations support final design of this vehicle, the design process for other TREAT vehicles, and the development of analyses practices for upcoming transient testing experiments. Models of the preliminary design Multi-SERTTA vehicle with rodlets were prepared and neutronics calculations were performed using MCNP6.1 with ENDF/B-VII.1 nuclear data libraries. Discussion of results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Parallel Computing in SCALE

The SCALE computational architecture has remained basically the same since its inception 30 years ago, although constituent modules and capabilities have changed significantly. This SCALE concept was intended to provide a framework whereby independent codes can be linked to provide a more comprehensive capability than possible with the individual programs - allowing flexibility to address a wide variety of applications. However, the current system was designed originally for mainframe computers with a single CPU and with significantly less memory than today's personal computers. It has been recognized that the present SCALE computation system could be restructured to take advantage of modern hardware and software capabilities, while retaining many of the modular features of the present system. Preliminary work is being done to define specifications and capabilities for a more advanced computational architecture. This paper describes the state of current SCALE development activities and plans for future development. With the release of SCALE 6.1 in 2010, a new phase of evolutionary development will be available to SCALE users within the TRITON and NEWT modules. The SCALE (Standardized Computer Analyses for Licensing Evaluation) code system developed by Oak Ridge National Laboratory (ORNL) provides a comprehensive and integrated package of codes and nuclear data for a wide range of applications in criticality safety, reactor physics, shielding, isotopic depletion and decay, and sensitivity/uncertainty (S/U) analysis. Over the last three years, since the release of version 5.1 in 2006, several important new codes have been introduced within SCALE, and significant advances applied to existing codes. Many of these new features became available with the release of SCALE 6.0 in early 2009. However, beginning with SCALE 6.1, a first generation of parallel computing is being introduced. In addition to near-term improvements, a plan for longer term SCALE enhancement activities has been developed to provide an integrated framework for future methods development. Some of the major components of the SCALE parallel computing development plan are parallelization and multithreading of computationally intensive modules and redesign of the fundamental SCALE computational architecture.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Subcritical Noise Measurements with a Nickel-Reflected Plutonium Sphere

Subcritical measurements were conducted with an a-phase plutonium sphere reflected by nickel hemishells using the 252Cf Source-Driven Noise Analysis (CSDNA) method to provide criticality safety benchmark data. Measured configurations included a bare plutonium sphere as well as the plutonium sphere reflected by the following nickel thicknesses: 1.27, 2.54, 3.81, 5.08, and 7.62 cm. A certain ratio of spectral quantities was measured for each configuration which varies linearly with the keff of the system. In addition, two types of Monte Carlo calculations were employed: a modified version of MCNP to calculate the ratio of spectral quantities and a KCODE calculation. From the measured and computed quantities the multiplication of each configuration can be approximated. A comprehensive uncertainty analysis was then performed that includes uncertainties in the geometry and materials present in the system in addition to the uncertainties in the method and nuclear data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of SAMMY for Non-Destructive Characterization of Irradiated Samples Using Neutron Transmission Measurements at VENUS

This report presents the application of SAMMY (Larson 2008), an R-matrix Bayesian fitting system, for analyzing neutron transmission data to enable non-destructive isotopic identification. Transmission measurements were conducted at the VENUS (Bilheux et al. 2023) beamline of the Spallation Neutron Source (SNS) using samples with unknown or partially characterized compositions. Through the application of SAMMY’s R-matrix Bayesian fitting capabilities to the measured transmission spectra and comparison against evaluated nuclear data libraries, isotopic constituents can be quantitatively determined based on their characteristic neutron resonance signatures. This methodology demonstrates significant potential for applications in nuclear safeguards, forensics, and post-irradiation examination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison Of A Neutron Kinetics Parameter For A Polyethylene Moderated Highly Enriched Uranium System

This paper examines the comparison of MCNP® code’s capability to calculate kinetics parameters effectively for a thermal system containing highly enriched uranium (HEU). The Rossi-α parameter was chosen for this examination because it is relatively easy to measure as well as easy to calculate using MCNP®’s kopts card. The Rossi-α also incorporates many other parameters of interest in nuclear kinetics most of which are more difficult to precisely measure. The comparison looks at two different nuclear data libraries for comparison to the experimental data. These libraries are ENDF/BVI (.66c) and ENDF/BVII (.80c).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Machine Learning to Predict MCNP Bias

For many real-world applications in radiation transport where simulations are compared to experimental measurements, like in nuclear criticality safety, the bias (simulated - experimental k eff ) in the calculation is an extremely important quantity used for code validation. The objective of this project is to accurately predict the bias of MCNP6 [1] criticality calculations using machine learning (ML) algorithms, with the intention of creating a tool that can complement the current nuclear criticality safety methods. In the latest release of MCNP6, the Whisper tool is available for criticality safety analysts and includes a large catalogue of experimental benchmarks, sensitivity profiles, and nuclear data covariance matrices. This data, coming from 1100+ benchmark cases, is used in this study of ML algorithms for criticality safety bias predictions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

MCNP6 Status

We, the development teams for MCNP, NJOY, and parts of ENDF, would like to invite you to a proposed 3 day workshop October 30, 31 and November 1 2012, to be held at Los Alamos National Laboratory. At this workshop, we will review new and developing missions that MCNP6 and the underlying nuclear data are being asked to address. LANL will also present its internal plans to address these missions and recent advances in these three capabilities and we will be interested to hear your input on these topics. Additionally we are interested in hearing from you additional technical advances, missions, concerns, and other issues that we should be considering for both short term (1-3 years) and long term (4-6 years)? What are the additional existing capabilities and methods that we should be investigating? The goal of the workshop is to refine priorities for mcnp6 transport methods, algorithms, physics, data and processing as they relate to the intersection of MCNP, NJOY and ENDF.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modernization at the Y-12 National Security Complex: A Case for Additional Experimental Benchmarks

Efforts are underway at the Y-12 National Security Complex (Y-12) to modernize the recovery, purification, and consolidation of un-irradiated, highly enriched uranium metal. Successful integration of advanced technology such as Electrorefining (ER) eliminates many of the intermediate chemistry systems and processes that are the current and historical basis of the nuclear fuel cycle at Y-12. The cost of operations, the inventory of hazardous chemicals, and the volume of waste are significantly reduced by ER. It also introduces unique material forms and compositions related to the chemistry of chloride salts for further consideration in safety analysis and engineering. The work herein briefly describes recent investigations of nuclear criticality for 235UO2Cl2 (uranyl chloride) and 6LiCl (lithium chloride) in aqueous solution. Of particular interest is the minimum critical mass of highly enriched uranium as a function of the molar ratio of 6Li to 235U. The work herein also briefly describes recent investigations of nuclear criticality for 235U metal reflected by salt mixtures of 6LiCl or 7LiCl (lithium chloride), KCl (potassium chloride), and 235UCl3 or 238UCl3 (uranium tri-chloride). Computational methods for analysis of nuclear criticality safety and published nuclear data are employed in the absence of directly relevant experimental criticality benchmarks.

36 MATERIALS SCIENCE↗

BENCHMARK EVALUATION OF THE START-UP CORE REACTOR PHYSICS MEASUREMENTS OF THE HIGH TEMPERATURE ENGINEERING TEST REACTOR

The benchmark evaluation of the start-up core reactor physics measurements performed with Japan’s High Temperature Engineering Test Reactor, in support of the Next Generation Nuclear Plant Project and Very High Temperature Reactor Program activities at the Idaho National Laboratory, has been completed. The evaluation was performed using MCNP5 with ENDF/B-VII.0 nuclear data libraries and according to guidelines provided for inclusion in the International Reactor Physics Experiment Evaluation Project Handbook. Results provided include updated evaluation of the initial six critical core configurations (five annular and one fully-loaded). The calculated keff eigenvalues agree within 1s of the benchmark values. Reactor physics measurements that were evaluated include reactivity effects measurements such as excess reactivity during the core loading process and shutdown margins for the fully-loaded core, four isothermal temperature reactivity coefficient measurements for the fully-loaded core, and axial reaction rate measurements in the instrumentation columns of three core configurations. The calculated values agree well with the benchmark experiment measurements. Fully subcritical and warm critical configurations of the fully-loaded core were also assessed. The calculated keff eigenvalues for these two configurations also agree within 1s of the benchmark values. The reactor physics measurement data can be used in the validation and design development of future High Temperature Gas-cooled Reactor systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear characterization of a general-purpose instrumentation and materials testing location in TREAT

The Transient Reactor Test facility (TREAT) was constructed in the late 1950s, provided thousands of transient irradiations before being placed in standby in 1994, and resumed operations in 2017 in order to reclaim its crucial role in nuclear-heated safety research. The latter half of TREAT’s historic operation was best known for integral-scale testing of fuel specimens under postulated reactor plant accident conditions, while TREAT’s earlier history included extensive simpler phenomena identification tests that elucidated fundamental behaviors and paved the way for these integral-scale tests. Advances in modern computational capabilities and a resurgence of interest in novel reactor technology have created an opportunity for emphasizing modernized science-based and separate effects test capabilities once again at TREAT. An innovative approach to this type of testing has been developed to leverage minor radioactivity built-in during brief TREAT irradiations in low activation hardware to facilitate handling for materials and instrumentation testing. This capability, termed the Minimal Activation Retrievable Capsule Holder (MARCH) irradiation vehicle system, will be used for inaugural fueled experiments in TREAT’s modern era as well as novel approaches to study materials undergoing neutron irradiation and instrumentation development and qualifications. This paper describes a comprehensive nuclear characterization, obtained via computational modeling, of the test position in the MARCH system. Though directly applicable to the MARCH system, the results also provide general quantification of the nuclear performance of the reactor and potential test materials, crucial for evaluating potential experiment design and response in TREAT. The neutron and photon flux environment was calculated via MCNP with ENDF/B-VII.1 nuclear data. Wire heating rate and DPA calculations were also performed and evaluated using historic TREAT test data. Furthermore, these calculations were performed to provide steady-state baseline reference values typical in both half- and full-slotted TREAT core configurations, enabling design scoping analysis prior to development of more specific design testing needs and transient testing experimentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data-Driven and Precursor-Group Uncertainty Propagation of Lattice Kinetic Parameters in UAM Benchmark

A new data-driven sampling-based framework was developed for uncertainty quantification (UQ) of the homogenized kinetic parameters calculated by lattice physics codes such as TRITON and Polaris. In this study, extension of the database for the delayed neutron data (DND) is performed by exploring more delayed neutron experiments and adding additional isotopes/actinides to the data libraries. Afterwards, the framework is utilized to obtain a deeper knowledge of the kinetic parameters’ sensitivity and uncertainty. The kinetic parameters include precursor-group-wise delayed neutron fraction (DNF) and decay constant. Input uncertainties include nuclear data (i.e., cross-sections) and DND (i.e., precursor group parameters and fractional delayed neutron yield). It is found that kinetic parameters, especially DNFs, have large uncertainties. The DNF uncertainty is driven by the cross-section uncertainties for LWR designs, while decay constant uncertainty is dominated by the DND uncertainties. The usage of correlated U-235 thermal DND in the UQ process significantly reduces the DND uncertainty contribution on the kinetic parameters. Large void fraction and presence of neutron absorber (e.g., control rod) increase the DNF uncertainty due to the hardening of neutron spectrum. High correlation between the DNF groups ( β 1 , . . , β 6 ) is observed, while the decay constant groups ( λ 1 , . . , λ 6 ) show weak correlation to each other and also to DNF groups. The DNF uncertainties of the dominant precursor group 4 for PWR, BWR, and VVER are about 7.5%, 9.4%, and 7.6%, respectively. The DNF uncertainty grows to larger values after fuel burnup. Kinetic parameters’ values and uncertainties provided here can be efficiently used in subsequent core calculations, point reactor kinetics, and other applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Manhattan Project 1940s research on the prompt fission neutron spectrum

We describe how the prompt fission neutron spectrum (PFNS) was determined for the Manhattan Project at Los Alamos. Early work before World War II at American and British universities is described, together with theoretical work by Feather at Cambridge and Bethe at Los Alamos. As the Manhattan Project was being planned in 1942, two experiments on natural uranium were commissioned that proved to be influential: 1) An integral experiment at Chicago by Christy and Manley that accurately determined the average PFNS spectrum energy, 2.2 ± 0.2 MeV; 2) Bloch and Staub’s Stanford cyclotron measurement of the PFNS spectrum, which obtained an average energy of 1.70 ± 0.34 MeV. These two papers, previously unavailable outside of Los Alamos, are reproduced in the Supplementary Appendix. From these data, at the beginning of the project in 1943 Serber estimated an average 235 U PFNS energy of 2 MeV, and indeed this agrees with today’s best estimate. The challenges facing the scientists involved both the availability of only very small samples of enriched uranium and plutonium targets, and fast neutron detection technologies. During the project, 235 U and 239 Pu PFNS were measured by Nicodemus and Staub. These also proved to be quite accurate and gave an average spectrum energy of 2 MeV for 235 U. [This is not reproduced in the Appendix because it was published after the war in Physical Review 89, 1288 (1953)]. New methods were developed to enable more accurate measurements, and this paper describes how the PFNS was determined surprisingly well by 1945. We end by describing the post-war measurements in the 50s, including the PFNS data used by Ford and Wheeler in their simulations in 1951, the Bonner 1952 data, the seminal 1952 Watt paper with a new empirical parametrization of the PFNS, and the accurate PFNS measurement undertaken at Los Alamos by Cranberg et al. in 1956. We compare the measurements with our best understanding today as embodied in the Evaluated Nuclear Data File ENDF/B-VIII.0. Some images from historical documents in our Los Alamos National Security Research Center (NSRC) archives are shown.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗