Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

A Hierarchical Control Architecture: Utilization of Behind-the-Meter Appliances with Increased Visibility and Controllability

Optimal operations of distribution systems to enhance reliability and resiliency can be achieved if information with higher fidelity can be accessed from grid premise devices. This paper discusses a hierarchical control architecture that can introduce higher visibility and controllability by utilizing the estimated injection and absorption of different behind-the-meter controllable loads, and DERs, including EVs, within a premise. The acquired information is used to make control decisions for scheduling the premise appliances to reduce energy consumptions. The premise controller can also optimize the consumptions on a day-to-day basis in addition to taking input signals from the utility operators to support grid-service events (e.g., peak shaving). The entire control architecture is designed in a modular and scalable fashion that provides benefits to the utility from the reuse of existing infrastructure while creating opportunities for various grid services to be enabled by the operation of premise controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Human-System Interface Risk Analysis Based on Redundancy-guided Systems-theoretic Hazard Analysis and Human Reliability Analysis

Human-system interfaces (HSIs) play an important role in enabling operators to communicate with the nuclear power plant (NPP) side. Getting the information required to understand a NPP’s current status or perform necessary actions for responding to a given operational context are representative operator tasks performed using HSIs. To date, HSIs have been mainly evaluated in the context of human reliability analysis (HRA). However, the current HSI evaluation that occurs during HRA may be challengeable on two fronts: (1) reflecting the unique characteristics of HSI systems and (2) considering situations in which HSIs are poorly operated due to software/hardware malfunctions. Accordingly, this study proposes an approach for specifically evaluating HSIs for digital instrumentation and controls (DI&C) systems, using Redundancy-guided Systems-theoretic Hazard Analysis (RESHA) and HRA. RESHA is a method for analyzing DI&C systems with redundancy features. In this study, we investigate how HSIs are evaluated in existing HRA methods, and what challenges exist in the current approaches. To better evaluate HSIs for DI&C systems, this study modifies the existing HSI evaluation process by additionally modeling the HSI back- and front- ends. In this paper, a HSI fault tree for the APR1400 DI&C system is introduced through a piping and instrumentation diagram. It then touches upon what aspects of the suggested method must be further researched.

99 GENERAL AND MISCELLANEOUS↗

Risk-informed Graded Approach for Reliability and Performance Assessment of Machine Learning and Artificial Intelligence for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

97 - MATHEMATICS AND COMPUTING↗

Risk-informed Graded Approach for Reliability and Performance Assessment for Advanced Condition Monitoring Techniques

With the shift away from time-based maintenance and toward condition-based maintenance, and to reduce overall maintenance costs, there has been an upsurge in the usage and development of advanced condition monitoring (ACM) techniques for real-time monitoring of nuclear power plant (NPP) components. ACM is particularly useful in the development of digital twins, which are designed to predict the failure or degradation of plant components. Successful implementation of ACM requires an assessment to inform the development of a risk-informed approach to evaluate the use of ACM to meet Nuclear Regulatory Committee (NRC) regulations for in-service testing (IST) programs. This includes the monitoring and diagnostics of reactor components and systems in current, new, and advanced reactors. A key component in ACM is the usage of machine learning (ML) and artificial intelligence (AI) algorithms that can employ real-time data from instrumentation and sensors to detect and predict reactor component degradations. Such predictive capabilities enable early detection of component degradation so as to help plant personnel plan and execute necessary maintenance. For successful implementation of ML/AI in ACM such that regulatory requirements are met, a risk-informed graded approach is needed to assess the reliability and performance of ML/AI for ACM. The American Society for Mechanical Engineers (ASME) developed their Operations and Maintenance (O&M) Code to provide guidance on safe, reliable O&M of NPPs. The IST section of the O&M Code specifically establishes requirements for IST and examination to gauge operational readiness of components in water-cooled NPPs. This paper presents a state-of-the-art review of how reliability and risk assessment can be integrated with ACM to assess component performance by non-nuclear industries. This is followed by different methodologies and approaches for conducting performance and reliability assessments so as to meet IST requirements for NPP components.

99 - GENERAL AND MISCELLANEOUS↗

Human Performance Analysis Depending on Operator Expertise (Student vs. Operator) and Simulator Complexity (Rancor Microworld vs. Compact Nuclear Simulator)

Human reliability analysis (HRA) evaluates human errors and provides human error probabilities (HEPs) for application in probabilistic safety assessment (PSA), which is a comprehensive safety assessment method for nuclear power plants (NPPs). Generally, HRA methods estimate HEPs based on human reliability data collected from actual historical measurement, simulator experiments, or expert judgement. Most recent HRA data collection studies focus on collecting data via full-scope main control room (MCR) simulators with actual licensed reactor operators. Contrary to this, Idaho National Laboratory (INL) has adopted a different approach, which attempts to collect HRA data based on experiment using simplified simulators and student participants by following the Simplified Human Error Experimental Program (SHEEP). This approach has a couple of advantages compared to full-scope data collection. Representatively, it has relatively low entry point for collecting HRA data, and secures large sample sizes with reasonable cost and labor. In the previous studies, we developed the SHEEP framework, then verified whether the data collected through the framework could support a representative full-scope data collection study, i.e., the Human Reliability Data Extraction (HuREX) study. Also, we analyzed human performance measurements depending on participant type (i.e., student vs. operator). In this paper, we analyze human performance data collected from an experiment comparing operator expertise and simulator complexity when using the more simplified simulator developed by INL, i.e., Rancor Microworld and the less simplified simulator, i.e., Compact Nuclear Simulator (CNS) developed by Korea Atomic Energy Research Institute (KAERI). Analysis of variance (ANOVA) tests and correlation analysis are used for analyzing the experimental data.

99 GENERAL AND MISCELLANEOUS↗

Enabling reliability assessments of pre-commercial perovskite photovoltaics with lessons learned from industrial standards [Enabling reliability of pre-commercial perovskite photovoltaics with lessons learned from industrial standards]

Here, photovoltaic modules are expected to operate in the field for more than 25 years, so reliability assessment is critical for the commercialization of new photovoltaic technologies. In early development stages, understanding and addressing the device degradation mechanisms are the priorities. However, any technology targeting large-scale deployment must eventually pass industry-standard qualification tests and undergo reliability testing to validate the module lifetime. In this Perspective, we review the methodologies used to assess the reliability of established photovoltaics technologies and to develop standardized qualification tests. We present the stress factors and stress levels for degradation mechanisms currently identified in pre-commercial perovskite devices, along with engineering concepts for mitigation of those degradation modes. Recommendations for complete and transparent reporting of stability tests are given, to facilitate future inter-laboratory comparisons and to further the understanding of field-relevant degradation mechanisms, which will benefit the development of accelerated stress tests.

14 SOLAR ENERGY↗

Performance Validation of Endcap Timing Layer Detector Modules for CMS Phase-2 Upgrade

The High-Luminosity Large Hadron Collider (HL-LHC) will operate up to 200 simultaneous collisions per bunch crossing, which is a significant jump from the current value of about 30 collisions per bunch crossing, producing significant pileup that challenges accurate event reconstruction. To address this, the Compact Muon Solenoid (CMS) experiment is implementing the Endcap Timing Layer (ETL), a precision timing detector designed to provide timing measurements with a resolution of approximately 50 ps per hit and 35 ps per reconstructed track. This project focuses on the characterization and validation of ETL detector modules using laboratory laser test data. ETL performance is evaluated by analyzing key quantities such as Bunch Crossing Identification (BCID), Time-of-Arrival (TOA), Time-over-Threshold (TOT), Noise Stability etc. The resulting analysis provides insight into the timing performance and operational stability of ETL modules, contributing to the quality assurance process req uired before their installation in the CMS experiment and ensure that the modules can meet the long-term reliability requirements of approximately 10 years of operation without replacement.

Chipara, Munashe [Fermilab]↗

Integration of optimal operational dispatch and controller determined dynamics for microgrid survivability

We present that the reliability and resilience of the electrical power grids are essential to industry, economy and society. Microgrids that are able to island from the bulk electrical grid are one technology that may vastly improve electrical power service to customer loads. To achieve these improvements, an islanded microgrid should be able to operate through the loss of one of its generators without shedding electrical load. The loss of one generator will typically result in significant additional loads, including transient overloads, being placed on the remaining generators. There is also the possibility of additional generator tripping during these processes (i.e. cascading failures), which would likely result in the collapse of the microgrid. The novelty of our work consists in incorporating dynamic models of generator controllers into a microgrid optimal dispatch formulation with the ultimate goal to avoid operational failures and ensure the “survivability” of all-inverter microgrids to generator loss and transient overloads. The integration of generator and controller dynamics into the optimal dispatch formulation significantly increases the computational complexity. As we develop algorithms to restore speed of the optimization, our method can be readily implemented into a new operational strategy capable of an unprecedented level of reliability against generator contingencies. In addition, we quantitatively illustrate the effect of the survivability constraints on the microgrid operating costs and how the related trade-off between capital and operating costs should be taken into account at the design stage. Finally, the methods developed here also apply to the dispatch of off-grid microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OPTIMAL DESIGN AND OPERATION OF HELIUM REFRIGERATION SYSTEMS USING THE GANNI CYCLE

The constant pressure ratio process, as implemented in the floating pressure - Ganni cycle, is a new variation to prior cryogenic refrigeration and liquefaction cycle designs that allows for optimal operation and design of helium refrigeration systems. This cycle is based upon the traditional equipment used for helium refrigeration system designs, i.e., constant volume displacement compression and critical flow expansion devices. It takes advantage of the fact that for a given load, the expander sets the compressor discharge pressure and the compressor sets its own suction pressure. This cycle not only provides an essentially constant system Carnot efficiency over a wide load range, but invalidates the traditional philosophy that the (‘TS’) design condition is the optimal operating condition for a given load using the as-built hardware. As such, the Floating Pressure- Ganni Cycle is a solution to reduce the energy consumption while increasing the reliability, flexibility and stability of these systems over a wide operating range and different operating modes and is applicable to most of the existing plants. This paper explains the basic theory behind this cycle operation and contrasts it to the traditional operational philosophies presently used.

42 ENGINEERING↗

Investigation of the Effect of Gate Oxide Screening with Adjustment Pulse on Commercial SiC Power MOSFETs

This paper presents a method to recover the negative threshold voltage shift during high field gate oxide screening of 1.2 kV 4H-SiC MOSFETs with an additional adjustment gate voltage pulse. To reduce field failure rates of the MOSFETs in operation, manufacturers perform a screening treatment to remove devices with extrinsic defects in the oxide. Current gate oxide screening procedures are limited to oxide fields at or below ~9 MV/cm for short durations (<1 s), which is not enough to remove all the devices with extrinsic defects. The results show that by implementing a lower field gate pulse, the threshold voltage shift can be partially recovered, and therefore the maximum screening field and time can be increased. However, both the initial screening pulse and the adjustment pulse require careful calibration to prevent significant degradation of the device threshold voltage, on-resistance, interface state density, or intrinsic lifetime. With a well calibrated set of pulses, higher screening fields can be utilized without significantly damaging the devices. This leads to an improvement in the overall screening efficiency of the process, reducing the number of devices with extrinsic oxide defects entering the field, and improving the reliability of the SiC MOSFETs in operation.

42 ENGINEERING↗

Resilient Solar and Storage Roadmap

Resilience to natural disasters is imperative for safe, economically productive cities. In the immediate aftermath of an earthquake, flood, or other disaster, one key element of resilience is continued operation of shelters and critical emergency management facilities. Operation of these facilities depends on reliable emergency power. Traditional emergency power systems use diesel generators with storage tanks, which provide power for only a few days in the absence of the electric or gas grid. However, a recent study has shown that gas and electric networks can require days or weeks to recover from a disaster, leaving facilities with generators at risk of running out of fuel. This has already been experienced in New York City after Hurricane Sandy where a combination of lengthy outages and high flood waters compromised the traditional diesel storage and generator backup infrastructure at hospitals and shelters. With the risk of natural disasters increasing due to climate change, we must turn to more resilient solutions for providing backup power to shelters, medical centers, and emergency operations centers. From 2015 to 2017, the City and County of San Francisco Solar and Storage for Resilience Project examined the use of microgrids and stand-alone solar electric generation with battery storage to provide resilient post-disaster power to critical facilities. The project evaluated 1,263 potential congregation and shelter sites across the city, 67 of which were identified as shelter sites with power requirements and opportunities to develop resilient infrastructure through solar and storage. Site visits were conducted for 18 of these buildings, spanning all 11 supervisor districts in San Francisco and a range of normal and emergency use types. The project team used observations from these site visits to create representative emergency power profiles for all 67 shelters in San Francisco. Using these profiles, the team found that 8.2 megawatts (MW) of photovoltaic panels and 12.9 MW of battery storage would be required to provide resilient backup power for San Francisco’s shelters following a disaster. Given the high capital cost of deploying this large resource, the project team investigated various financing options — a public-private partnership was found to be a viable pathway for financing resilient solar and storage. Given the added benefit of energy cost savings in normal operation, a public-private partnership financing model would save the City and County of San Francisco 6% over a traditional design-bid-build approach over a 20-year portfolio lifetime. This roadmap documents the project’s steps of identifying critical facilities, surveying power requirements, assessing renewable potential, evaluating financing options to develop the solar and storage systems for resiliency, and modeling individual sites for solar and storage installation. This roadmap also examines the challenges critical facilities face in providing resilient power, such as key technical, political, and financing barriers, as well as the opportunities and policy recommendations to further advance resilient solar and storage development in San Francisco. While this report focuses on a detailed study of San Francisco, the methods and outcomes are applicable to any city or town.

14 SOLAR ENERGY↗

Operation of a Flexible Dynamic Boundary Microgrid with Multiple Islands

A microgrid with dynamic boundary can expand or shrink its boundary depending on available local distributed energy resources (DER). Compared to conventional microgrid with fixed boundary, it can lead to better DER utilization and improved reliability. Previous literature has only considered the operation of a microgrid with a single island that is energized by stable voltage sources. This paper introduces control function designs that can effectively synchronize islands inside a dynamic boundary microgrid, depending on the operation status of each voltage source inside the islands. An overview of the components and rationale within the control function designs is provided, and hardware-in-the-loop simulation results are analyzed to demonstrate the effectiveness of the control functions.

Zhen, Shuying↗

Enabling Situation Awareness Under High Levels of Automation: Results From An Experimental Study

The Department of Energy’s Advanced Reactor Technologies (ART) program sponsors research, development and deployment activities through its Next Generation Nuclear Plant, Advanced Reactor Concepts, and Advanced Small Modular Reactor (aSMR) programs to promote safety, technical, economical, and environmental advancements of innovative Generation IV nuclear energy technologies. The Human Automation Collaboration (HAC) research project is located under the aSMR program, which identifies developing advanced instrumentation and controls and human-machine interfaces as one of four key research areas. New nuclear plants are expected to employ significantly more advanced technology than the systems in the current reactor fleet as well as utilize automation to a greater extent. However, advancing technology and increasing automation does not necessarily imply improved efficiency and safety of the plant. Instead, a number of concerns about how these technologies will affect human performance and the overall safety of the plant need to be addressed. More specifically, it is important to investigate how the operator and the automation work as a team to ensure effective and safe plant operation, also known as the human-automation collaboration (HAC). The HAC project at INL, investigates collaboration methods between a system’s automation and human operators and how that collaboration impacts the performance and reliability of overall system performance. Some well documented human performance issues associated with typical human automation collaboration methods include reduced operator situation awareness (SA), complacency, and over reliance on the system automation (Endsley, 1995, 1996, 1997; Endsley & Kaber, 1999; Kaber & Endsley, 1997, 2004; Parasuraman et al., 2000; Sheridan, 2002; Wickens & Hollands, 2000; Wright & Kaber, 2005). The HAC research effort addresses how to best design the collaboration between the operators and the automated systems in a manner that has the greatest positive impact on overall plant performance and reliability, hence addressing many of the documented issues. The ultimate goal of the HAC research effort is to develop design guidance that supports optimal interaction between humans and automated systems.

99 GENERAL AND MISCELLANEOUS↗

Passive Safety System Reliability Analysis: Methodology, Application, and Results

Many advanced reactor designs rely on passive systems to provide assurance that certain safety functions, such as reactivity control and reactor heat removal, are maintained during transient scenarios. The performance of these systems is sensitive to boundary and environmental conditions and can lead to functional failure, which is the inability of the system to perform as intended even without any physical failures. Additionally, conditions can cause the passive systems to operate in an intermediate or degraded state. These operational modes of passive systems and their overall reliability can be difficult to capture in traditional probabilistic frameworks where discrete operating modes are assumed or time-dependent boundary conditions are not accounted for. Novel strategies and methods are needed to be able to capture the reliability of these passive systems and their impact on facility safety. The current abstract provides a summary of such a methodology and examples of its use in a case study, the GE Hitachi (GEH) PRISM probabilistic safety assessment (PSA), and the U.S. Department of Energy (USDOE) Versatile Test Reactor (VTR) PSA.

Bucknor, M.↗

Research and Experiment on the Key Technologies of the Spent Fuel Storage in HTR-PM - 18486

High Temperature Reactor demonstration project of China (HTR-PM) is one of the major national science and technology projects, some key technologies for the design and operation of the demonstration project are formed to research according to the main technology. The spent fuel storage system is one of the main systems of the HTR-PM. In order to solve the technical problems related to the operation of spent fuel, several experiments have been conducted, including: spent fuel loading, getting back, spent fuel canister hoisting, storage well cover hoisting, storage canister drop and so on. In the study process, the test facility has been set up to carry on the operation and the experiment verification to ensure the reliability and safety of the spent fuel storage system. Spent fuel storage system undertakes spent fuel receiving, spent fuel canister transfer, storage, lifting and other functions in HTR-PM, the project research need to solve several major technical problems related to the spent fuel operation, which mainly include: Develop the transportable spent fuel canister for HTR-PM, the canister is corrosion resistance, impact resistance, and is in subcritical condition when loaded with fuel. Develop the spent fuel canister hoister, which could hoist the spent fuel canister safely and reliably. Develop the spent fuel storage well cover hoister, which could hoist the well cover safely and reliably. Study the small probability of the spent fuel canister in extreme condition of canister hoist falling accidents, to ensure the radiation protect safety and residual heat removal safety of the canister in case of the canister drop when lifting. Develop the spent fuel charging device and return device, which could load the spent fuel elements into the spent fuel canister, and could take out the fuel elements from the canister. The key technology and equipment of the spent fuel storage system in HTR-PM would be solved through the research of the project. Project research is very important for the implementation and safe operation of the HTR-PM project. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grid-Friendly Renewable Energy: Solar and Wind Participation in Automatic Generation Control Systems

This paper focuses on emerging technological and regulatory considerations of using solar and wind generators to provide essential reliability services through participation in area-wide automatic generation control (AGC) systems. AGC systems enable a grid operator to centrally and automatically manage the output of interconnected generators, storage devices, and controllable loads to maintain reliable and safe system operations. The paper highlights recent experiences of solar and wind on AGC, as well as recent developments that may enable VRE to participate in AGC in the near future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Rancor-HUNTER: Using a Simulator Engine for Realistic Human Performance Modeling of Nuclear Power Operations

The Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) is a software system to simulate human performance in support of human reliability analysis (HRA) in nuclear power plants. This paper summarizes recent work to integrate HUNTER with a plant simulator, namely the Rancor Microworld Simulator. Rancor is an offshoot of earlier work at Idaho National Laboratory (INL) to support plant modernization. The graphical software tools used to mimic digital human-system interface upgrades at INL’s Human Systems Simulation Laboratory were linked to the Rancor Microworld Simulator, an INL-developed simplified plant model. HUNTER becomes a “virtual operator” coupled to the Rancor simulator, thereby allowing a tight coupling between a digital human twin and a digital twin of the plant. Rancor-HUNTER may be run through Monte Carlo iterations across a dynamic range of performance shaping factors, thereby producing distributions of human performance in terms of procedure paths, errors instantiations, and task durations. This paper overviews the various unique features of Rancor-HUNTER and presents an example run of Rancor-HUNTER for a startup scenario.

99 - GENERAL AND MISCELLANEOUS↗

Decarbonizing Cooking Appliances With Hydrogen

A novel hydrogen compatible heterogeneous burner prototype was engineered, fabricated, and evaluated for applications in cooking appliances. The key features targeted and accomplished under this effort included fuel flexibility, tolerance to high hydrogen concentrations (up to 85% in atmospheric design and 100% in premixed design), wide range of thermal power ratings, thermal cycling, reliability, and most importantly safety. The burner was operated in the range of 3000 – 12,000 Btu/h under all practical operating conditions (cold start, hot restart, fuel concentration variance). The heterogeneous oxidation burner technology was evaluated for overall performance targeting safety, reliability, emissions, fuel flexibility, and energy efficiency in a commercial RV and residential cooking range appliance prototypes. The burner demonstrated safe and reliable performance generating infrared heating energy without the consumption of any parasitic energy while using low-cost materials. Performance evaluation testing of the novel IR burner demonstrated fuel flexibility with hydrogen blended natural gas while significantly eliminating air pollutants like NOx and methane and increasing the energy efficiency by up to 20%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗