Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

From Remotely-Sensed SIF to Ecosystem Structure, Function, and Service: Part I - Harnessing Theory

Solar-induced chlorophyll fluorescence (SIF) is a remotely sensed optical signal emitted during the light reactions of photosynthesis. The past two decades have witnessed an explosion in availability of SIF data at increasingly higher spatial and temporal resolutions, sparking applications in diverse research sectors (e.g., ecology, agriculture, hydrology, climate, and socioeconomics). These applications must deal with complexities caused by tremendous variations in scale and the impacts of interacting and superimposing plant physiology and three-dimensional vegetation structure on the emission and scattering of SIF. At present, these complexities have not been overcome. To advance future research, the two companion reviews aim to (1) develop an analytical framework for inferring terrestrial vegetation structures and function that are tied to SIF emission, (2) synthesize progress and identify challenges in SIF research via the lens of multi-sector applications, and (3) map out actionable solutions to tackle these challenges and offer our vision for research priorities over the next 5–10 years based on the proposed analytical framework. This paper is the first of the two companion reviews, and theory oriented. It introduces a theoretically rigorous yet practically applicable analytical framework. Guided by this framework, we offer theoretical perspectives on three overarching questions: (1) The forward (mechanism) question—How are the dynamics of SIF affected by terrestrial ecosystem structure and function? (2) The inference question: What aspects of terrestrial ecosystem structure, function, and service can be reliably inferred from remotely sensed SIF and how? (3) The innovation question: What innovations are needed to realize the full potential of SIF remote sensing for real-world applications under climate change? The analytical framework elucidates that process complexity must be appreciated in inferring ecosystem structure and function from the observed SIF; this framework can serve as a diagnosis and inference tool for versatile applications across diverse spatial and temporal scales.

carbon fluxes↗

Comparison of the Optical Connectivity Method to X-Ray spray measurements in the near field of a diesel injector

For diesel sprays, the primary breakup processes are only rarely understood due to the high optical density and the resulting difficulties to measure them with extremely high spatial and sufficient temporal resolution. The Optical Connectivity Method (OCM) has been proposed in the last years to allow the determination of the breakup length of the connected liquid core, thus giving a measurement quantity of the primary breakup. In this research, an improved optical setup of the OCM is applied to a three-hole test injector nozzle where several measurement techniques are compared currently under well-defined conditions up to 100 MPa injection pressure. In this work, the direct comparison with X-Ray measurements done at the Advanced Photon Source of the Argonne National Laboratory will be described. This allows an evaluation of the OCM technique and a comparison of the different measurement quantities in the first 500 μm range of the spray. The structure of the spray is measured by X-Ray phase contrast imaging and the fuel mass distribution is measured by X-Ray absorption imaging. A detailed comparison of the two X-Ray techniques and the OCM technique has been possible for the first time. It is found that the measurement data of the spray near field are very congruent with all three methods. Due to this comparison, the measurement of the non-perturbed length, which describes the distance from the nozzle orifice up to the point where the formation of surface disturbances is starting, by the OCM is validated for the first time. Within this non-perturbed length of the spray, the OCM signal is weak before it starts to illuminate from the scattering of the perturbed surface. Hence, the OCM technique can deliver two characteristic length scales, the non-perturbed length and the breakup length , characterizing the primary spray breakup.

33 ADVANCED PROPULSION SYSTEMS↗

From remotely sensed solar-induced chlorophyll fluorescence to ecosystem structure, function, and service: Part I—Harnessing theory

Solar-induced chlorophyll fluorescence (SIF) is a remotely sensed optical signal emitted during the light reactions of photosynthesis. The past two decades have witnessed an explosion in availability of SIF data at increasingly higher spatial and temporal resolutions, sparking applications in diverse research sectors (e.g., ecology, agriculture, hydrology, climate, and socioeconomics). These applications must deal with complexities caused by tremendous variations in scale and the impacts of interacting and superimposing plant physiology and three-dimensional vegetation structure on the emission and scattering of SIF. At present, these complexities have not been overcome. To advance future research, the two companion reviews aim to (1) develop an analytical framework for inferring terrestrial vegetation structures and function that are tied to SIF emission, (2) synthesize progress and identify challenges in SIF research via the lens of multi-sector applications, and (3) map out actionable solutions to tackle these challenges and offer our vision for research priorities over the next 5-10 years based on the proposed analytical framework. This paper is the first of the two companion reviews, and theory oriented. It introduces a theoretically rigorous yet practically applicable analytical framework. Guided by this framework, we offer theoretical perspectives on three overarching questions: (1) The forward (mechanism) question—How are the dynamics of SIF affected by terrestrial ecosystem structure and function? (2) The inference question: What aspects of terrestrial ecosystem structure, function, and service can be reliably inferred from remotely sensed SIF and how? (3) The innovation question: What innovations are needed to realize the full potential of SIF remote sensing for real-world applications under climate change? In conclusion, the analytical framework elucidates that process complexity must be appreciated in inferring ecosystem structure and function from the observed SIF; this framework can serve as a diagnosis and inference tool for versatile applications across diverse spatial and temporal scales.

59 BASIC BIOLOGICAL SCIENCES↗

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

Pre-Launch GOES-R Risk Reduction Activities for the Geostationary Lightning Mapper

The GOES-R Geostationary Lightning Mapper (GLM) is a new instrument planned for GOES-R that will greatly improve storm hazard nowcasting and increase warning lead time day and night. Daytime detection of lightning is a particularly significant technological advance given the fact that the solar illuminated cloud-top signal can exceed the intensity of the lightning signal by a factor of one hundred. Our approach is detailed across three broad themes which include: Data Processing Algorithm Readiness, Forecast Applications, and Radiance Data Mining. These themes address how the data will be processed and distributed, and the algorithms and models for developing, producing, and using the data products. These pre-launch risk reduction activities will accelerate the operational and research use of the GLM data once GOES-R begins on-orbit operations. The GLM will provide unprecedented capabilities for tracking thunderstorms and earlier warning of impending severe and hazardous weather threats. By providing direct information on lightning initiation, propagation, extent, and rate, the GLM will also capture the updraft dynamics and life cycle of convective storms, as well as internal ice precipitation processes. The GLM provides information directly from the heart of the thunderstorm as opposed to cloud-top only. Nowcasting applications enabled by the GLM data will expedite the warning and response time of emergency management systems, improve the dispatch of electric power utility repair crews, and improve airline routing around thunderstorms thereby improving safety and efficiency, saving fuel and reducing delays. The use of GLM data will assist the Bureau of Land Management (BLM) and the Forest Service in quickly detecting lightning ground strikes that have a high probability of causing fires. Finally, GLM data will help assess the role of thunderstorms and deep convection in global climate, and will improve regional air quality and global chemistry/climate modeling. The GLM has a robust design that benefits and improves upon its strong heritage of NASA-developed LEO predecessors, the Optical Transient Detector (OTD) and the Lightning Imaging Sensor (LIS). GLM will have a substantially larger number of pixels within the focal plane, two lens systems, and multiple Real-Time Event Processors REPS for on-board event detection and data compression to provide continuous observations of the Americas and adjacent oceans.

Goodman, S. J.↗

A simple differential steady-state method to measure the thermal conductivity of solid bulk materials with high accuracy

Accurate measurements of thermal conductivity are of great importance for materials research and development. Steady-state methods determine thermal conductivity directly from the proportionality between heat flow and an applied temperature difference (Fourier Law). Although theoretically simple, in practice, achieving high accuracies with steady-state methods is challenging and requires rather complex experimental setups due to temperature sensor uncertainties and parasitic heat loss. We developed a simple differential steady-state method in which the sample is mounted between an electric heater and a temperature-controlled heat sink. Our method calibrates for parasitic heat losses from the electric heater during the measurement by maintaining a constant heater temperature close to the environmental temperature while varying the heat sink temperature. This enables a large signal-to-noise ratio which permits accurate measurements of samples with small thermal conductance values without an additional heater calibration measurement or sophisticated heater guards to eliminate parasitic heater losses. Additionally, the differential nature of the method largely eliminates the uncertainties of the temperature sensors, permitting measurements with small temperature differences, which is advantageous for samples with high thermal conductance values and/or with strongly temperature-dependent thermal conductivities. In order to accelerate measurements of more than one sample, the proposed method allows for measuring several samples consecutively at each temperature measurement point without adding significant error. We demonstrate the method by performing thermal conductivity measurements on commercial bulk thermoelectric Bi 2 Te 3 samples in the temperature range of 30–150 °C with an error below 3%.

47 OTHER INSTRUMENTATION↗

Fiber Pulling Apparatus

The fiber optics industry has grown into a multi-billion marketplace that will continue to grow into the 21st century. Optical fiber communications is currently dominated by silica glass technology. Successful efforts to improve upon the low loss transmission characteristics of silica fibers have propelled the technology into the forefront of the communications industry. However, reaching the theoretical transmission capability of silica fiber through improved processing has still left a few application areas in which other fiber systems can provide an influential role due to specific characteristics of high theoretical transmission in the 2 - 3 micron wavelength region. One of the other major materials used for optical fibers is the systems based upon Heavy Metal Fluoride Glass (HMFG). Commercial interest is driven primarily by the potential for low loss repeaterless infrared fibers. An example of the major communications marketplace which would benefit from the long distance repeaterless capability of infrared fibers is the submarine cables which link the continents. When considering commercial interests, optical fiber systems provide a healthy industrial position which continues to expand. Major investments in the systems used for optical fiber communications have continued to increase each year and are predicted to continue well into the next century. Estimates of 8.5% compounded annually are predicted through 1999 for the North American market and 1 1 % worldwide. The growth for the optical fiber cable itself is expected to continue between 44 and 50 per cent of the optical fiber communications budget through 1999. The total budget in 1999 world-wide is expected to be in the neighborhood of $9 billion. Another survey predicts that long haul telecommunications represents 15% of a world-wide fiber optics market in 1998. The actual amount allotted to cable was not specified. However, another market research had predicted that the cable costs alone represents more than 50% of the total budget each year through 1998. A newly emerging activity is the commercial development of doped optical fibers which can be pumped by laser diodes to provide amplification of the communication signals. This technology is newly emerging and will be developed for commercial interests in the United States by Galileo Electro-optical Incorporated in Sturbridge, MA on a license from British Telecom. Long repeaterless communication links provide the biggest stimulus for this technology. As an example of the of the revenues involved in the optical fiber communications 3 industry, the current trade journal lists that for the fiscal years, 1991 - 1994, 185 separate undersea links were established. In addition, another 105 links are planned through 1998. The distribution of revenues involved in the undersea installations is roughly $8.5 billion through 1993 and another $13 billion planned through 1998. A large portion of the future activity (34%) is planned for Southeast Asia and the Pacific Region. Other examples of the commercial utility of optical fiber networks is given in a recent scientific symposium in which the outlook for HMFG infrared fiber was determined to be very bright.Another area of interest lies in the use of fiber optics for laser surgery delivery systems.

Workman, Gary L.↗

Optical delay encoding for fast timing and detector signal multiplexing in PET

Purpose: The large number of detector channels in modern positron emission tomography (PET) scanners poses a challenge in terms of readout electronics complexity. Multiplexing schemes are typically implemented to reduce the number of physical readout channels, but often result in performance degradation. Novel methods of multiplexing in PET must be developed to avoid this data degradation. The preservation of fast timing information is especially important for time-of-flight PET. Methods: A new multiplexing scheme based on encoding detector interaction events with a series of extremely fast overlapping optical pulses with precise delays is demonstrated in this work. Encoding events in this way potentially allows many detector channels to be simultaneously encoded onto a single optical fiber that is then read out by a single digitizer. A two channel silicon photomultiplier-based prototype utilizing this optical delay encoding technique along with dual threshold time-over-threshold is demonstrated. Results: The optical encoding and multiplexing prototype achieves a coincidence time resolution of 160 ps full width at half maximum (FWHM) and an energy resolution of 13.1% FWHM at 511 keV with 3 × 3 × 5 mm{sup 3} LYSO crystals. All interaction information for both detectors, including timing, energy, and channel identification, is encoded onto a single optical fiber with little degradation. Conclusions: Optical delay encoding and multiplexing technology could lead to time-of-flight PET scanners with fewer readout channels and simplified data acquisition systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-resolution energy spectra from neutron direct-geometry spectrometers

Neutron direct-geometry time-of-flight chopper spectroscopy is instrumental in studying fundamental excitations of vibrational and/or magnetic origin. We report here that techniques in super-resolution optical imagery (which is in real-space) can be adapted to enhance resolution and reduce noise for a neutron spectroscopy (an instrument for mapping excitations in reciprocal space). The procedure to reconstruct super-resolution energy spectra of phonon density of states relies on a realization of multiframe registration, accurate determination of the energy-dependent point spread function, asymmetric nature of instrument resolution broadening, and iterative reconstructions. Applying these methods to phonon density of states data for a graphite sample demonstrates contrast enhancement, noise reduction, and ~5-fold improvement over nominal energy resolution. The data were collected at three different incident energies measured at the wide angular-range chopper spectrometer at the Spallation Neutron Source.

47 OTHER INSTRUMENTATION↗

ALMA Observations of α Centauri First Detection of Main-Sequence Stars at 3 mm Wavelength

The precise mechanisms that provide the non-radiative energy for heating the chromosphere and the corona of the Sun and those of other stars constitute an active field of research. By studying stellar chromospheres one aims at identifying the relevant physical processes. Defining the permittable extent of the parameter space can also serve as a template for the Sun-as-a-star. This feedback will probably also help identify stars that potentially host planetary systems that are reminiscent of our own. Earlier observations with Herschel and APEX have revealed the temperature minimum of Alpha Cen, but these were unable to spatially resolve the binary into individual components. With the data reported in this Letter, we aim at remedying this shortcoming. Furthermore, these earlier data were limited to the wavelength region between 100 and 870 um. In the present context, we intend to extend the spectral mapping (SED) to longer wavelengths, where the contrast between stellar photospheric and chromospheric emission becomes increasingly evident. The Atacama Large Millimeter submillimeter Array (ALMA) is particularly suited to point sources, such as unresolved stars. ALMA provides the means to achieve our objectives with both its high sensitivity of the collecting area for the detection of weak signals and the high spatial resolving power of its adaptable interferometer for imaging close multiple stars. This is the first detection of main-sequence stars at a wavelength of 3 mm. Furthermore, the individual components of the binary Alpha CenAB are clearly detected and spatially well resolved at all ALMA wavelengths. The high signal-to-noise ratios of these data permit accurate determination of their relative flux ratios, i.e., S(sub y(sup B)) / S(sub y(sup A))> = 0.54 +/- 0.04 at 440 μm, = 0.46 +/- 0.01 at 870 μm, and = 0.47 +/- 0.006 at 3.1 mm, respectively.. The previously obtained flux ratio of 0.44+/-0.18, which was based on measurements in the optical and at 70 μm, is consistent with the present ALMA results, albeit with a large error bar. The observed 3.1 mm emission greatly exceeds what is predicted from the stellar photospheres, and undoubtedly arises predominantly as free-free emission in the ionized chromospheric plasmas of both stars. Given the distinct difference in their cyclic activity, the similarity of their submm SEDs appears surprising.

Herschel↗

State-selective probing of CO 2 autoionizing inner valence Rydberg states with attosecond extreme ultraviolet four-wave-mixing spectroscopy

Nonlinear spectroscopies can disentangle spectra that are congested due to inhomogeneous broadening. Here, in conjunction with theoretical calculations, attosecond extreme ultraviolet (XUV) four-wave-mixing (FWM) spectroscopy is utilized to probe the dynamics of autoionizing inner valence excited Rydberg states of the polyatomic molecule, CO 2 . This tabletop nonlinear technique employs a short attosecond XUV pulse train and two noncollinear, few-cycle near-infrared pulses to generate background-free XUV wave-mixing signals. FWM emission is observed from the n=5-7 states of the Henning sharp ndσ g Rydberg series that converges to the ionic $\widetilde{B}$ 2 Σ$^{+}_{u}$ state. However, these transient emission signals decay with lifetimes of 33 ± 6, 53 ± 2, and 94 ± 2 fs, respectively, which calculations show are consistent with the lifetimes of the short-lived n=6-8 members of the nsσ g character Henning diffuse Rydberg series. The oscillator strengths of transitions between states involved in all possible resonant FWM processes are calculated, verifying that the nonlinear spectra are dominated by pathways described by an initial excitation to the diffuse nsσ g Rydberg series and emission from the sharp ndσ g Rydberg series. The results substantiate not only that attosecond XUV FWM spectroscopy produces rigorous and meaningful measurements of ultrafast dynamics in polyatomic systems, but also that nonlinear spectroscopic techniques are versatile tools to selectively probe dynamics that are otherwise difficult to access.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Graph Neural Networks for low-energy event classification & reconstruction in IceCube

IceCube, a cubic-kilometer array of optical sensors built to detect atmospheric and astrophysical neutrinos between 1 GeV and 1 PeV, is deployed 1.45 km to 2.45 km below the surface of the ice sheet at the South Pole. The classification and reconstruction of events from the in-ice detectors play a central role in the analysis of data from IceCube. Reconstructing and classifying events is a challenge due to the irregular detector geometry, inhomogeneous scattering and absorption of light in the ice and, below 100 GeV, the relatively low number of signal photons produced per event. To address this challenge, it is possible to represent IceCube events as point cloud graphs and use a Graph Neural Network (GNN) as the classification and reconstruction method. The GNN is capable of distinguishing neutrino events from cosmic-ray backgrounds, classifying different neutrino event types, and reconstructing the deposited energy, direction and interaction vertex. Based on simulation, we provide a comparison in the 1 GeV–100 GeV energy range to the current state-of-the-art maximum likelihood techniques used in current IceCube analyses, including the effects of known systematic uncertainties. For neutrino event classification, the GNN increases the signal efficiency by 18% at a fixed background rate, compared to current IceCube methods. Alternatively, the GNN offers a reduction of the background (i.e. false positive) rate by over a factor 8 (to below half a percent) at a fixed signal efficiency. For the reconstruction of energy, direction, and interaction vertex, the resolution improves by an average of 13%–20% compared to current maximum likelihood techniques in the energy range of 1 GeV–30 GeV. The GNN, when run on a GPU, is capable of processing IceCube events at a rate nearly double of the median IceCube trigger rate of 2.7 kHz, which opens the possibility of using low energy neutrinos in online searches for transient events.

47 OTHER INSTRUMENTATION↗

Elucidating the Interfacial Barriers in Lanthanide Back-Extraction: From Water to Oil and Back Again

Recovery of critical rare earth elements from complex mixtures has long been realized via solvent extraction, where ions in an aqueous phase are separated into an organic phase using amphiphilic ligands. While a great deal of effort has been placed on understanding this forward reaction, substantial knowledge gaps in the back-extraction process remain. This includes the mechanism of interfacial dissociation and transport back into a highly acidic aqueous phase for further processing. In this work, we connect back-extraction kinetics made in realistic solvent extraction systems to salient interfacial chemistry and structure that represent bottlenecks in the back-extraction of lanthanide ions. We show that the interface between the two liquid phases varies dramatically based on the composition of both phases. Water stretching signals are shown to report on the population of lingering interfacial complexes and are thus used as a reporter of competitive adsorption from excess free ligands in solution for limited interfacial vacancies. We show that excess free ligands, often used to improve forward extractions, set up interfacial blockades inhibiting back-extraction both kinetically and thermodynamically. In conclusion, this insight opens up avenues to tune interfacial properties to facilitate a more dynamic, exchangeable interface to speed up back-extractions while using less energy intensive chemical swings.

Interfaces↗

Enhancing Nanoparticle Detection in Interferometric Scattering (iSCAT) Microscopy Using a Mask R-CNN

Interferometric scattering microscopy (iSCAT) is a label-free optical microscopy technique that enables imaging of individual nano-objects such as nanoparticles, viruses, and proteins. Essential to this technique is the suppression of background scattering and identification of signals from nano-objects. In the presence of substrates with high roughness, scattering heterogeneities in the background, when coupled with tiny stage movements, cause features in the background to be manifested in background-suppressed iSCAT images. Traditional computer vision algorithms detect these background features as particles, limiting the accuracy of object detection in iSCAT experiments. Here, in this paper, we present a pathway to improve particle detection in such situations using supervised machine learning via a mask region-based convolutional neural network (mask R-CNN). Using a model iSCAT experiment of 19.2 nm gold nanoparticles adsorbing to a rough layer-by-layer polyelectrolyte film, we develop a method to generate labeled datasets using experimental background images and simulated particle signals and train the mask R-CNN using limited computational resources via transfer learning. We then compare the performance of the mask R-CNN trained with and without inclusion of experimental backgrounds in the dataset against that of a traditional computer vision object detection algorithm, Haar-like feature detection, by analyzing data from the model experiment. Results demonstrate that including representative backgrounds in training datasets improved the mask R-CNN in differentiating between background and particle signals and elevated performance by markedly reducing false positives. The methodology for creating a labeled dataset with representative experimental backgrounds and simulated signals facilitates the application of machine learning in iSCAT experiments with strong background scattering and thus provides a useful workflow for future researchers to improve their image processing capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron beam fluorescence measurements in the Boeing hypersonic shock tunnel

The Calspan electron beam fluorescence (EBF) measurement system is described along with the results of measurements made in hypersonic flow. Numerous self-emitting metallic species were identified, many of which may be associated with an aging/erosion process within the B30HST. Because there were only 16 tunnel runs, it was only possible to obtain spectral measurements over a limited range of wavelengths and time sampling periods. Many spectral features of the flow remain uninvestigated. Because flow self-emission is important to all optical diagnostic techniques, it is recommended that additional spectral studies by performed. The three electron beam-excited species that were identified are nitrogen, helium, and nitric oxide. The high metallic radiation background interfered with attempts to obtain the time-wise variation of N2 density and He radiation with the optical fiber/PMT channels. In the case of the N2 density measurements the result of interference was increased uncertainty. Unfortunately, the interference caused the time-wise He measurements to fail completely. It is recommended that the electron beam be modulated to provide discrimination against the background radiation in future N2 density measurements. Careful data reduction produced useful measurements of N2 vibrational temperature, even though the high background from metallic species significantly increased measurement uncertainty. Perhaps the recommended additional spectral studies would reveal N2(+) First Negative System band-pair regions having less background. Detection of the He arrival was easily accomplished with the spectrometer/array detector system. Because of this, it is recommended that this means of detecting He arrival be used in the future. With proper calibrations of the system an He number density could be obtained. Although the flow conditions were out of limits for the run in which the NO spectrum was recorded, the usefulness of the NO spectrum for determination of free-stream rotational temperature was demonstrated and should be exploited in future experiments. Indeed, based on the strong NO signals, it is recommended that lower resolution NO spectra be obtained to provide a measure of NO vibrational temperature in the same manner that the N2 temperature was obtained.

Price, Linwood L.↗

Phytoplankton-Fluorescence-Lifetime Vertical Profiler

A battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency

Fernandez, Salvador M.↗

B{yields}X{sub s}{gamma} constraints on the top quark anomalous t{yields}c{gamma} coupling

Observation of the top quark flavor changing neutral process t{yields}c+{gamma} at the LHC would be the signal of physics beyond the standard model. If anomalous t{yields}c{gamma} coupling exists, it will affect the precisely measured B(B{yields}X{sub s}{gamma}). In this paper, we study the effects of a dimension 5 anomalous tc{gamma} operator in B{yields}X{sub s}{gamma} decay to derive constraints on its possible strength. It is found that, for real anomalous t{yields}c{gamma} coupling {kappa}{sub tcR}{sup {gamma}}, the constraints correspond to the upper bounds B(t{yields}c+{gamma})<6.54x10{sup -5} (for {kappa}{sub tcR}{sup {gamma}}>0) and B(t{yields}c+{gamma})<8.52x10{sup -5} (for {kappa}{sub tcR}{sup {gamma}}<0), respectively, which are about the same order as the 5{sigma} discovery potential of ATLAS (9.4x10{sup -5}) and slightly lower than that of CMS (4.1x10{sup -4}) with 10 fb{sup -1} integrated luminosity operating at {radical}(s)=14 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature and impurity concentration effects on Mg{sub (1-x)}Co{sub x}Ga{sub 2}O{sub 4} photoluminescence

Ceramic materials doped with magnetic ions that present emission in the visible and near-infrared spectral regions are very attractive due to their inherent tunability. Possible applications include their utilization as optoelectronic and display devices, as spintronic material, in signal transmission and information storage, in the fabrication of special papers, as dosimetric materials and room temperature solid state lasers. Materials doped with tetrahedrally coordinated Co{sup 2+} present wide bands originated from electronic transitions in the ionic unfilled 3d electronic shell. The Co{sup 2+} 3d electrons are outside of the ion core and therefore their optical properties are directly affected by static and dynamic properties of ligand anions. The magnesium gallate MgGa{sub 2}O{sub 4} is a partially inverted spinel described as a AB{sub 2}O{sub 4} material with two possible positions for A{sup 2+} and B{sup 3+} cations. Polycrystalline MgGa{sub 2}O{sub 4} : Co{sup 2+} samples were produced by solid-state reactions between ultra-pure raw oxides MgO, {beta}-Ga{sub 2}O{sub 3} and the desired CoCO{sub 3} quantities. Photoluminescence data at room temperature and 77 K of MgGa{sub 2}O{sub 4} polycrystalline samples doped with 0.1 and 1.0% of Co{sup 2+} are presented. The visible emission observed is attributed to the {sup 4}T{sub 1}({sup 4}P) {yields}{sup 4}A{sub 2}({sup 4}F) spin-allowed transition of Co{sup 2+} ions tetrahedrally coordinated by O{sup 2-} ions. The photoluminescence intensity decreases with temperature, but 90% of the 77 K emission integrated intensity remains at room temperature. Moreover, from lifetime results we estimate that Co{sup 2+} emission quantum efficiency is about 1.0 at room temperature. We also observe that between 0.1 and 1.0% of Co{sup 2+} the luminescence intensity decreases. For 1.0% of Co{sup 2+} the luminescence intensity is 37% of the obtained for 0.1%. This fact is attributed to non-radiative transfer processes of impurity ion relaxation that become competitive at 1.0% of Co{sup 2+} and show that there is a strongly impurity-concentration luminescence dependence. We also observed that for the higher concentration the band is slightly shifted to the infrared region. Due to low impurity ion concentration it would not be expected an energy transfer between Co{sup 2+} ions, therefore non-radiative decay processes are responsible by temperature luminescence quenching.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗