Search NASA⌕ Search

SEARCH · Search NASA

Results for “Parallelism”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Memory-Aware External Facelist Calculation: A Data-Parallel Atomic Hash Counting Approach

Unstructured volumetric meshes serve as fundamental data representations in various scientific simulations and analyses. They play a crucial role in representing complex computational domains and are essential for important numerical techniques, such as finite element analysis. Whenever such a mesh is read from a file, streamed in-situ, or generated by algorithms, scientific visualization libraries rely on calculating the external surface of a geometry, named “external facelist”, to produce a polygonal mesh for rendering. Consequently, external facelist calculation has become one of the most widely used algorithms in the scientific visualization domain, necessitating optimal performance. In this paper, we explore relevant work on external facelist calculation algorithms in two common visualization libraries, VTK and Viskores, assess their performance and memory constraints, and introduce a novel memory-aware external facelist calculation algorithm employing an atomic hash counting approach. This algorithm fully leverages Viskores' data-parallel primitive operations, facilitating its execution across diverse many-core architectures. Our algorithm features the lowest memory footprint on the GPU and the second-lowest on the CPU among all evaluated methods, and it also delivers the fastest performance on both CPU and GPU. It has been made available under an open-source license in the VTK and Viskores visualization systems.

Tsalikis, Spiros [Kitware] (ORCID:0000000151137195↗

Tutorial: Parallel simulation on supercomputers

This tutorial introduces typical hardware and software characteristics of extant and emerging supercomputing platforms, and presents issues and solutions in executing large-scale parallel discrete-event simulation scenarios on such high performance computing systems. Covered topics include synchronization, model organization, example applications, and observed performance from illustrative large-scale runs.

Perumalla, Kalyan S.↗

Development of a Stiffness-Based Chemistry Load Balancing Scheme, and Optimization of Input/Output and Communication, to Enable Massively Parallel High-Fidelity Internal Combustion Engine Simulations

A closed-cycle gasoline compression ignition engine simulation near top dead center (TDC) was used to profile the performance of a parallel commercial engine computational fluid dynamics code, as it was scaled on up to 4096 cores of an IBM Blue Gene/Q supercomputer. The test case has 9 million cells near TDC, with a fixed mesh size of 0.15 mm, and was run on configurations ranging from 128 to 4096 cores. Profiling was done for a small duration of 0.11 crank angle degrees near TDC during ignition. Optimization of input/output performance resulted in a significant speedup in reading restart files, and in an over 100-times speedup in writing restart files and files for post-processing. Improvements to communication resulted in a 1400-times speedup in the mesh load balancing operation during initialization, on 4096 cores. An improved, “stiffness-based” algorithm for load balancing chemical kinetics calculations was developed, which results in an over 3-times faster run-time near ignition on 4096 cores relative to the original load balancing scheme. With this improvement to load balancing, the code achieves over 78% scaling efficiency on 2048 cores, and over 65% scaling efficiency on 4096 cores, relative to 256 cores.

CFD, Mira, Supercomputing, High Performance Comput↗

Optimization of a parallel hole collimator/CdZnTe gamma-camera architecture for scintimammography

Purpose: Small field-of-view CdZnTe (CZT) gamma cameras are increasingly studied for breast lesion detection to complement mammography or ultrasonographic findings. However, in classical collimation configurations, they remain limited by the trade-off between spatial resolution and sensitivity. The HiSens architecture was proposed to overcome these limitations. Using an accurate 3D localization of the interactions inside the detector, this architecture leads to a gain in sensitivity without loss in spatial resolution. In this article, the relevance of the HiSens architecture for planar scintimammography is studied. Methods: A detective quantum efficiency (DQE) computation method is developed and used to optimize the dimensioning of a parallel hole collimator dedicated to scintimammography. Based on the DQE curves, the impact of the collimator-to-detector distance is studied. Two algorithms are proposed to combine data acquired with different collimator-to-detector distances. Results: It is shown that CZT detector virtual pixelization increases system sensitivity by 3.3 while preserving a standard LEHR spatial resolution. The introduction of a gap between the CZT detector and the collimator is useful to modulate the DQE curve shape. The combination of data acquired using different gaps in the image formation process leads to enhanced restoration of the frequency content of the images, resulting in image contrast and spatial resolution improvements. Conclusions: Acquisition duration or injected activity could be markedly reduced if the HiSens architecture with an appropriate collimator-detector gap were used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a pixelated GSO gamma camera system with tungsten parallel hole collimator for single photon imaging

Purpose: In small animal imaging using a single photon emitting radionuclide, a high resolution gamma camera is required. Recently, position sensitive photomultiplier tubes (PSPMTs) with high quantum efficiency have been developed. By combining these with nonhygroscopic scintillators with a relatively low light output, a high resolution gamma camera can become useful for low energy gamma photons. Therefore, the authors developed a gamma camera by combining a pixelated Ce-doped Gd{sub 2}SiO{sub 5} (GSO) block with a high quantum efficiency PSPMT. Methods: GSO was selected for the scintillator, because it is not hygroscopic and does not contain any natural radioactivity. An array of 1.9 mm x 1.9 mm x 7 mm individual GSO crystal elements was constructed. These GSOs were combined with a 0.1-mm thick reflector to form a 22 x 22 matrix and optically coupled to a high quantum efficiency PSPMT (H8500C-100 MOD8). The GSO gamma camera was encased in a tungsten gamma-ray shield with tungsten pixelated parallel hole collimator, and the basic performance was measured for Co-57 gamma photons (122 keV). Results: In a two-dimensional position histogram, all pixels were clearly resolved. The energy resolution was {approx}15% FWHM. With the 20-mm thick tungsten pixelated collimator, the spatial resolution was 4.4-mm FWHM 40 mm from the collimator surface, and the sensitivity was {approx}0.05%. Phantom and small animal images were successfully obtained with our developed gamma camera. Conclusions: These results confirmed that the developed pixelated GSO gamma camera has potential as an effective instrument for low energy gamma photon imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-71: Feasibility Study On MRI-Based BANG3 Gel Dosimetry Using Dual-Source Parallel RF Transmission System

Purpose: In this work, we present the feasibility of use of the parallel RF transmission with multiple RF source (MultiTransmit) imaging in MRI-based polymer gel dosimetry. Methods: The commercially available BANG3 gel was used for gel dosimetry. Spin-spin relaxation rate R2 was used to quantify the absorbed dose. The image quality (signal-to-noise ratio, SNR; image uniformity) and B1 field inhomogeneity between conventional single-source and MultiTransmit MR imaging were compared. Finally, the estimated R2 uncertainty σ(R2) and dosimetric performance (i.e., dose resolution) between conventional single-source and MultiTransmit MR imaging were compared. Results: Image quality and B1 field homogeneity within each calibration vial and large phantom was statistically better in MultiTransmit imaging than in conventional single-source RF transmission imaging (P < 0.005 for all calibration vials). In particular, σ(R2) (defined as the standard uncertainty of R2) was lower on the MultiTransmit images than on the conventional single-source images. Furthermore, the MultiTransmit measurement gives a lower than that obtained using the conventional single-source method. Conclusion: The improved image quality and B1 homogeneity resulted in reduced dose uncertainty (i.e., σ(R2) and dose resolution) in MRI-based polymer gel dosimetry, suggesting that MultiTransmit MR imaging has potential benefits for use in clinical 3D gel dosimetry without the need for the complicated B1 field correction method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A visual evaluation of the spatial resolution using the x-ray test pattern indicated that the resolution was 1.8 lp/mm at the IFP and 1.2 lp/mm at heights of −100 and 100 mm from the IFP. The authors demonstrated that a spatial resolution of 1.2–1.8 lp/mm could be obtained within heights of 200 mm of the IFP. The slice sensitivity varied between 11.1 and 13.8 mm for heights between −50 and 100 mm, and there was no critical change in the slice sensitivity within a height range of 150 mm around the IFP. The phantom results demonstrated that tomosynthesis and long-view images could be reconstructed. Conclusions: PS-TS-F provides tomosynthesis images while using low-cost systems that have no tomographic scanning function, such as tableside-controlled universal R/F systems or universal radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Biochemical parallels between catabolic pathways for lignin-associated aromatic dimers

Lignin is one of the most common biopolymers on Earth. In nature, lignin is primarily deconstructed by fungi into mixtures of aromatic compounds that are then assimilated by bacteria and fungi. Industrially, lignin is primarily generated as a byproduct of pulp and paper production and burned for process heat. However, if the appropriate assimilatory pathways were identified, deconstructed lignin could be funneled into value-added products using engineered bacteria. Foundational work has described pathways for assimilation of diverse monomeric aromatic compounds such as protocatechuate, ferulate, and syringate, as well as select dimers including those with β-O-4 and 5-5 interunit linkages. Recent advances have elucidated additional pathways for dimer assimilation, including pathways for new substrates as well as parallel pathways for previously characterized substrates. Comparing these dimer assimilation pathways can illuminate the underlying biochemical logic of assimilation for lignin-associated aromatic dimers and provide opportunities for metabolic engineering to enhance lignin valorization.

Sphingomonas↗

Massively Parallel Fitness Profiling Reveals Multiple Novel Enzymes in Pseudomonas putida Lysine Metabolism

Despite intensive study for 50 years, the biochemical and genetic links between lysine metabolism and central metabolism in Pseudomonas putida remain unresolved. To establish these biochemical links, we leveraged r andom b arcode t ra n sposon seq uencing (RB-TnSeq), a genome-wide assay measuring the fitness of thousands of genes in parallel, to identify multiple novel enzymes in both L - and D -lysine metabolism. We first describe three pathway enzymes that catabolize L -2-aminoadipate ( L -2AA) to 2-ketoglutarate (2KG), connecting D -lysine to the TCA cycle. One of these enzymes, P. putida 5260 (PP_5260), contains a DUF1338 domain, representing a family with no previously described biological function. Our work also identified the recently described coenzyme A (CoA)-independent route of L -lysine degradation that results in metabolization to succinate. We expanded on previous findings by demonstrating that glutarate hydroxylase CsiD is promiscuous in its 2-oxoacid selectivity. Proteomics of selected pathway enzymes revealed that expression of catabolic genes is highly sensitive to the presence of particular pathway metabolites, implying intensive local and global regulation. This work demonstrated the utility of RB-TnSeq for discovering novel metabolic pathways in even well-studied bacteria, as well as its utility a powerful tool for validating previous research. IMPORTANCE P. putida lysine metabolism can produce multiple commodity chemicals, conferring great biotechnological value. Despite much research, the connection of lysine catabolism to central metabolism in P. putida remained undefined. Here, we used random barcode transposon sequencing to fill the gaps of lysine metabolism in P. putida We describe a route of 2-oxoadipate (2OA) catabolism, which utilizes DUF1338-containing protein P. putida 5260 (PP_5260) in bacteria. Despite its prevalence in many domains of life, DUF1338-containing proteins have had no known biochemical function. We demonstrate that PP_5260 is a metalloenzyme which catalyzes an unusual route of decarboxylation of 2OA to D -2-hydroxyglutarate ( D -2HG). Our screen also identified a recently described novel glutarate metabolic pathway. We validate previous results and expand the understanding of glutarate hydroxylase CsiD by showing that can it use either 2OA or 2KG as a cosubstrate. Our work demonstrated that biological novelty can be rapidly identified using unbiased experimental genetics and that RB-TnSeq can be used to rapidly validate previous results.

59 BASIC BIOLOGICAL SCIENCES↗

A point radiator parallel to a plane layer with negative refractive index

Focusing of an electromagnetic wave radiated by a point source and transmitted through a plane layer filled with a medium with negative refractive index is considered. An elementary electric Hertzian dipole located in the air (or vacuum) parallel to the boundaries of the layer is considered as a point source of radiation. It is rigorously shown that, after transmitting through a layer with negative refractive index, the electromagnetic wave of the dipole is focused into a certain domain. The dimensions of the focusing region are investigated. The results of the investigation show that the use of homogeneous materials with negative refraction does not allow one to overcome the diffraction limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electronic topological transition in an n-BiSb semiconductor alloy in the quantum limit range of magnetic fields for H-parallel C{sub 2}

The galvanomagnetic properties of single-crystal samples of the Bi{sub 0.93}Sb{sub 0.07} semiconductor alloy with the electron density n = 1.6 x 10{sup 17} cm{sup -3} in magnetic fields up to 14 T at T = 1.6 K have been investigated. The resistivity {rho} and Hall coefficient R have been measured as functions of the magnetic field directed along the binary axis of a crystal for a current flowing through a sample along the bisector axis; i.e., the components {rho}{sub 22} and R{sub 32,1} have been measured. The strong anisotropy of the electron spectrum of the samples makes it possible to separately observe quantum oscillations of the magnetoresistance {rho}{sub 22}(H) for H -parallel C{sub 2} in low magnetic fields for two equivalent ellipsoids with small extremal cross sections (secondary ellipsoids) and in high magnetic fields for electrons of the ellipsoid with a large extremal cross section (main ellipsoid). An increase in the energy of the electrons of secondary ellipsoids in the quantum limit magnetic fields is accompanied by the flow of electrons to the main ellipsoid; i.e., an electronic topological transition occurs from the three-valley electron spectrum to the single-valley one. After the flow stops, the Fermi energy E{sub F} increases from 18 meV to 27.8 meV. With an increase in the quantizing magnetic field, the Fermi energy of the electrons decreases both in the region of quantum oscillations of the resistance that are attributed to the electrons of the secondary ellipsoids and in the region of oscillations associated with the electrons of the main ellipsoid. The Hall coefficient R{sub 32,1} decreases in high magnetic fields; this behavior indicates the absence of the electron magnetic freezing effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of metallic surface microroughness on the probability and spectrum of plasmon excitation by a fast charged particle moving parallel to the surface

The Green's function of the electric field of plasmons is determined in a semi-infinite medium with an abrupt plasma boundary where nonequilibrium conduction electrons either undergo elastic reflection from the boundary or 'stick' to it and give rise to a stationary surface charge. The angular reflection of elastically scattered electrons can be either specular or diffuse. The Green's function is used to find the singleevent spectrum of energy loss by a fast electron moving parallel to the boundary. The effect of electronboundary scattering parameters on the structure of bulk and surface plasmon resonances is analyzed. The probability of transition radiation of bulk plasmon by an electron moving in vacuum is examined. A new type of surface resonance is found under conditions of perfectly elastic scattering of conduction electrons from the plasma boundary, similar in structure to a tangential surface plasmon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parametric electroconvection in a weakly conducting fluid in a horizontal parallel-plate capacitor

We study the flows of a nonuniformly heated weakly conducting fluid in an ac electric field of a horizontal parallel-plate capacitor. Analysis is carried out for fluids in which the charge formation is governed by electroconductive mechanism associated with the temperature dependence of the electrical conductivity of the medium. Periodic and chaotic regimes of fluid flow are investigated in the limiting case of instantaneous charge relaxation and for a finite relaxation time. Bifurcation diagrams and electroconvective regimes charts are constructed. The regions where fluid oscillations synchronize with the frequency of the external field are determined. Hysteretic transitions between electroconvection regimes are studied. The scenarios of transition to chaotic oscillations are analyzed. Depending on the natural frequency of electroconvective system and the external field frequency, the transition from periodic to chaotic oscillations can occur via quasiperiodicity, a subharmonic cascade, or intermittence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The light wave flow effect in a plane-parallel layer with a quasi-zero refractive index under the action of bounded light beams

It is shown that external optical radiation in the 450–1200 nm range can be efficiently transformed under the action of bounded light beams to a surface wave that propagates along the external and internal boundaries of a plane-parallel layer with a quasi-zero refractive index. Reflection regimes with complex and real angles of refraction in the layer are considered. The layer with a quasi-zero refractive index in this boundary problem is located on a highly reflective metal substrate; it is shown that the uniform low reflection of light is achieved in the wavelength range under study.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dependence of energy resolution of a plane-parallel HPGe detector on bias voltage upon registration of low-energy X-rays

In this study, we theoretically analyze the processes in a plane-parallel high-purity germanium (HPGe) detector. The generating function of factorial moments describing the process of registration of low-energy X-rays by the HPGe detector with consideration of capture of charge carriers by traps is obtained. It is demonstrated that the coefficients of expansion of the average signal amplitude and variance in power series over the quantity inversely proportional to the bias voltage of the detector allow one to determine the Fano factor, the product of the charge carrier lifetime and mobility, and other characteristics of the semiconductor material of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression of electron magnetotunneling between parallel two-dimensional GaAs/InAs electron systems by the correlation interaction

Magnetotunneling between two-dimensional GaAs/InAs electron systems in vertical resonant tunneling GaAs/InAs/AlAs heterostructures is studied. A new-type of singularity in the tunneling density of states, specifically a dip at the Fermi level, is found; this feature is drastically different from that observed previously for the case of tunneling between two-dimensional GaAs tunnel systems in terms of both the kind of functional dependence and the energy and temperature parameters. As before, this effect manifests itself in the suppression of resonant tunneling in a narrow range near zero bias voltage in a high magnetic field parallel to the current direction. Magnetic-field and temperature dependences of the effect's parameters are obtained; these dependences are compared with available theoretical and experimental data. The observed effect can be caused by a high degree of disorder in two-dimensional correlated electron systems as a result of the introduction of structurally imperfect strained InAs layers.

36 MATERIALS SCIENCE↗

Friction Force and Radiative Heat Exchange in a System of Two Parallel Plates in Relative Motion: Corollaries of the Levine–Polevoi–Rytov Theory

It has been shown that the fundamental results obtained in the works by Levine–Polevoi–Rytov (1980) and Rytov (1990) adequately describe the rate of radiative heat exchange and frictional force in a system of two thick parallel plates in relative motion, in full agreement with the results obtained by other authors later. A numerically calculated friction force for Drude metals turns out to be higher by a factor of 10{sup 7} than the early result obtained by Polevoi. In addition, the friction force significantly increases with increasing the conductivity of the plates or increasing the relaxation time of electrons with decreasing temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗