Transparent Conductive Adhesives for Tandem Solar Cells Using Polymer-Particle Composites

Transparent conductive adhesives (TCAs) can enable conductivity between two substrates, which is useful for a wide range of electronic devices. Here, we have developed a TCA composed of a polymer-particle blend with ethylene-vinyl acetate as the transparent adhesive and metal-coated flexible poly(methyl methacrylate) microspheres as the conductive particles that can provide conductivity and adhesion regardless of the surface texture. This TCA layer was designed to be nearly transparent, conductive in only the out-of-plane direction, and of practical adhesive strength to hold the substrates together. The series resistance was measured at 0.3 and 0.8 O cm2 for 8 and 0.2% particle coverage, respectively, while remaining over 92% was transparent in both cases. For applications in photovoltaic devices, such as mechanically stacked multijunction III-V/Si cells, a TCA with 1% particle coverage will have less than 0.5% power loss due to the resistance and less than 1% shading loss to the bottom cell.

14 SOLAR ENERGY↗

Charge carrier transport in thin conjugated polymer films: influence of morphology and polymer/substrate interactions

The performance of conjugated polymer (CP)-based electronic devices relies on optimal charge carrier mobilities, which are determined by monomeric architecture, degree of polymerization, chain conformation, and the nano- and mesoscale morphologies. With regard to the latter, we discuss two effects that have received limited attention in the literature, yet important for device performance optimization: (1) the role of morphological disorder and of CP/substrate interactions on the in-plane and out-of-plane carrier transport in CPs; (2) the impact of morphological disorder on charge transfer at the CP/substrate interface. The emergence of film thickness-dependent carrier mobilities, varying over two orders of magnitude within a length scale of 200 nm, and band-bending phenomena, extending tens of nanometers within the CP, are associated with these effects. These findings suggest areas for further research in order to enable widespread applications of next-generation CP-based devices.

36 MATERIALS SCIENCE↗

Oxidation performance and limitations of additively manufactured SiC/Si-O-C composites at elevated temperatures

Here, SiC preforms were infiltrated with polycarbosiloxane preceramic polymer to create low-cost SiC—Si x O y C z matrix composites for possible high temperature application. The effect of specimen annealing conditions on the steam and air oxidation resistance was analyzed. Air exposures from 900–1500°C showed stability of the Si x O y C z matrix phase with moderate oxidation resistance. After 900°C exposures, oxidation of the composite is primarily limited to the matrix phase, and only at 1200 and 1500°C was SiC consumption visualized. Steam cycle exposures at 1200°C resulted in rapid linear oxidation of the composites with induced specimen swelling from volume expansion associated with internal oxidation. Specimens annealed in argon were found to be the most oxidation resistant due to increased matrix crystallinity and carbon retention. The results of this work were used to develop clear strategies for improving the high-temperature properties of SiC—Si x O y C z composites.

36 MATERIALS SCIENCE↗

Improving Cooperative Interactions Between Halogenated Aromatic Additives and Aromatic Side Chain Acceptors for Realizing 19.22% Efficiency Polymer Solar Cells

Processing additive plays an important role in the standard operation procedures for fabricating top performing polymer solar cells (PSCs) through efficient interactions with key photovoltaic materials. However, improving interaction study of acceptor materials to high performance halogenated aromatic additives such as diiodobenzene (DIB) is a widely neglected route for molecular engineering toward more efficient device performances. Here, in this work, two novel Y-type acceptor molecules of BTP-TT and BTP-TTS with different aromatic side chains on the outer positions are designed and synthesized. The resulting aromatic side chains significantly enhanced the interactions between the acceptor molecules and DIB through an arene/halogenated arene interaction, which improved the crystallinity of the acceptor molecules and induced a polymorph with better photovoltaic performances. Thus, high power conversion efficiencies (PCEs) of 18.04% and 19.22% are achieved in binary and ternary blend devices using BTP-TTS as acceptor and DIB as additive. Aromatic side chain engineering for improving additive interactions is proved to be an effective strategy for achieving much higher performance photovoltaic materials and devices.

36 MATERIALS SCIENCE↗

Morphology, Modification and Characterisation of Electrospun Polymer Nanofiber Adsorbent Material Used in Metal Ion Removal

Among a wide range of technologies available to separate metal ions, adsorption is a major treatment technique for removing or recovering metals from aqueous solutions. Electrospun nanofiber adsorbents have attracted research consideration due to the distinctive properties such as their high surface area, high porosity and high adsorption capacity which makes nanofibers a good choice for selective metal recovery applications. Thus, the modification of electrospun nanofiber adsorbents by functionalisation with suitable ligands for selective metal extraction is a growing area of scientific research aiming to improve the selectivity of the adsorption process. This study reviews and summarises available information related to the different nanofiber modification processes for increasing adsorption efficiency, functionality and selectivity of modified nanofiber adsorbents as well as improving their durability and stability during use. The surface properties of an adsorbent is an essential control factor for its metal ion adsorption efficiency. The various techniques available for characterisation of specific properties of nanofiber adsorbents are also considered. Lastly, the recovery of the metal ions after adsorption by regenerating adsorbent materials and understanding the kinetics of nanofiber adsorption processes is summarised and recommendations made for further studies in order to address existing weaknesses of these materials.

36 MATERIALS SCIENCE↗

Gelatin as a new humidity sensing material: Characterization and limitations

The goal of this work is to assert the utility of collagen and its denatured counterpart gelatin as cost-effective alternatives to existing sensing layers comprised of polymers. Rather than producing a material that will need to be discarded or recycled, collagen, as a by-product of the meat and leather industry, could be repurposed. This work examines the feasibility of using collagen as a sensing layer. Planar electrodes were patterned with lift-off process to work with the natural characteristics of gelatin by utilizing metal vapor deposition, spin coating, and photolithography. Characterization methods have also been optimized through the creation of specialized humidity chambers that isolate specific characteristics such as response time, accuracy, and hysteresis. Collagen-based sensors are found to have a sensitivity to moisture in the range of 0.065 pF/%RH. Diffusion characteristics were also analyzed with the diffusion coefficient found to be 2.5 × 10{sup −5} cm{sup 2}/s. Absorption and desorption times were found to be 20 seconds and 8 seconds, respectively. Hysteresis present in the data is attributed to temperature cross-sensitivity. Ultimately, the utility of collagen as a dielectric sensing material is, in part, due to its fibrous macrostructures as well its hydrophilic sites along the peptide chains. Gelatin was patterned between and below interdigitated copper electrodes and tested as a relative humidity sensor. This work shows that gelatin, which is inexpensive, widely available, and easy to process, can be an effective dielectric sensing polymer for capacitive-type relative humidity sensors.

36 MATERIALS SCIENCE↗

Pentiptycene-based ladder polymers with configurational free volume for enhanced gas separation performance and physical aging resistance

Significance Gas separation membranes are an emerging energy-efficient alternative toward conventional, energy-intensive separation technologies such as cryogenic distillation. Ladder polymers with intrinsic microporosity show exceptional promise toward redefining state-of-the-art gas separation membranes due to their high permeability (throughput) and selectivity (separation efficiency). However, they are typically inhibited by major reductions in permeability over time due to collapsing membrane free volume (open space between polymer chains), forfeiting their greatest asset. This work explores a route toward enhanced aging resistance and overall separation performance by incorporating pentiptycene (an H-shaped scaffold containing five fused arene rings) into ladder-like polymers to incorporate natural, more permanent “micropores” that aren’t susceptible to densification of polymer chains that occurs over time in traditional microporous polymers.

36 MATERIALS SCIENCE↗

$\mathrm{ATR}$-$\mathrm{FTIR}$ spectroscopy as a probe for metal ion binding onto immobilized ligands

ATR-FTIR spectroscopy is shown to be useful in probing metal ion binding to ligands immobilized on polymer beads. Lu(III) is the metal ion, phosphinic and sulfonic acids are the immobilized ligands, and polystyrene beads crosslinked at low and high levels are the support. Analysis is based on ligand band positions and intensities before and after complexation as a function of time. ATR spectra of the phosphinic acid show two types of binding sites with different accessibilities: surface ligands that bind Lu(III) from solution and interior ligands that gain ions by diffusion from the surface. Initially bound Lu(III) ions are mobile within the solid phase and their movement is accompanied by the breaking of hydrogen bonds among the phosphinic acid ligands to form Lu(III) phosphinate complexes. Competition between hydrogen bonding and bond-making with Lu(III) contributes to slow sorption rates compared to results from the sulfonic acid ligand whose strong acidity and ionizability allows rapid Lu(III) sorption. Comparing ATR spectra of the phosphinic acid bound to lightly- and highly-crosslinked polystyrene shows how the extent of crosslinking affects the transport mechanism.

36 MATERIALS SCIENCE↗

Metal–Ligand Based Mechanophores Enhance Both Mechanical Robustness and Electronic Performance of Polymer Semiconductors

The backbone of diketopyrrolopyrrole-thiophene-vinylene-thiophene-based polymer semiconductors (PSCs) is modified with pyridine (Py) or bipyridine ligands to complex Fe(II) metal centers, allowing the metal–ligand complexes to act as mechanophores and dynamically crosslink the polymer chains. Here, mono- and bi-dentate ligands are observed to exhibit different degrees of bond strengths, which subsequently affect the mechanical properties of these Wolf-type-II metallopolymers. The counter ion also plays a crucial role, as it is observed that Py-Fe mechanophores with non-coordinating BPh 4 – counter ions (Py-FeB) exhibit better thin film ductility with lower elastic modulus, as compared to the coordinating chloro ligands (Py-FeC). Interestingly, besides mechanical robustness, the electrical charge carrier mobility can also be enhanced concurrently when incorporating Py-FeB mechanophores in PSCs. This is a unique observation among stretchable PSCs, especially that most reports to date describe a decreased mobility when the stretchability is improved. Next, it is determined that improvements to both mobility and stretchability are correlated to the solid-state molecular ordering and dynamics of coordination bonds under strain, as elucidated via techniques of grazing-incidence X-ray diffraction and X-ray absorption spectroscopy techniques, respectively. This study provides a viable approach to enhance both the mechanical and the electronic performance of polymer-based soft devices.

36 MATERIALS SCIENCE↗

SU-E-T-70: Commissioning a Multislice CT Scanner for X-Ray CT Polymer Gel Dosimetry

Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the single slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering Research Council of Canada (NSERC)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental and computational analysis of failure mechanisms in unidirectional carbon fiber reinforced polymer laminates under longitudinal compression loading

Here, his study investigates the failure mechanisms of notched unidirectional (UD) carbon fiber reinforced polymer (CFRP) laminates subjected to longitudinal compressive loading. A sequence of failure initiation and propagation is observed based on optical microscopy images of specimens during failure. The micrographs reveal that the main failure mechanism in UD laminates is fiber kinking failure. The influence of manufacturing defects and voids on fiber kinking mechanisms is also analyzed. The results show that the voids in the resin-rich area lead to kink-band splitting, while in some cases the voids cause the kink-band to deflect in a new direction depending on the location of the voids. The next focus of this study is to propose a computational micromechanics model considering local fiber waviness to study the fiber kinking failure mechanism. The computational results on kink-band formation and stress-strain response show good consistency with our experimental analysis. Lastly, the failure envelopes of σ 11 -σ 22 and σ 11 -τ 12 subjected to combined loading conditions are obtained from the computational model, which provide essential inputs for future theoretical failure criteria.

36 MATERIALS SCIENCE↗

Sodium bromide electron-extraction layers for polymer bulk-heterojunction solar cells

Inexpensive and non-toxic sodium bromide (NaBr) was introduced into polymer solar cells (PSCs) as the cathode buffer layer (CBL) and the electron extraction characteristics of the NaBr CBL were investigated in detail. The PSCs based on NaBr CBL with different thicknesses (i.e., 0 nm, 0.5 nm, 1 nm, and 1.5 nm) were prepared and studied. The optimal thickness of NaBr was 1 nm according to the photovoltaic data of PSCs. The open-circuit voltage (V{sub oc}), short-circuit current density (J{sub sc}), fill factor (FF), and power conversion efficiency (PCE) of the PSC with 1 nm NaBr were evaluated to be 0.58 V, 7.36 mA/cm{sup 2}, 0.63, and 2.70%, respectively, which were comparable to those of the reference device with the commonly used LiF. The optimized photovoltaic performance of PSC with 1 nm NaBr was ascribed to the improved electron transport and extraction capability of 1 nm NaBr in PSCs. In addition, the NaBr CBL could prevent the diffusion of oxygen and water vapor into the active layer and prolong the lifetime of the devices to some extent. Therefore, NaBr layer could be considered as a promising non-toxic CBL for PSCs in future.

36 MATERIALS SCIENCE↗

Molecular orientation distributions during injection molding of liquid crystalline polymers: Ex situ investigation of partially filled moldings

The development of molecular orientation in thermotropic liquid crystalline polymers (TLCPs) during injection molding has been investigated using two-dimensional wide-angle X-ray scattering coordinated with numerical computations employing the Larson-Doi polydomain model. Orientation distributions were measured in 'short shot' moldings to characterize structural evolution prior to completion of mold filling, in both thin and thick rectangular plaques. Distinct orientation patterns are observed near the filling front. In particular, strong extension at the melt front results in nearly transverse molecular alignment. Far away from the flow front shear competes with extension to produce complex spatial distributions of orientation. The relative influence of shear is stronger in the thin plaque, producing orientation along the filling direction. Exploiting an analogy between the Larson-Doi model and a fiber orientation model, we test the ability of process simulation tools to predict TLCP orientation distributions during molding. Substantial discrepancies between model predictions and experimental measurements are found near the flow front in partially filled short shots, attributed to the limits of the Hele-Shaw approximation used in the computations. Much of the flow front effect is however 'washed out' by subsequent shear flow as mold filling progresses, leading to improved agreement between experiment and corresponding numerical predictions.

36 MATERIALS SCIENCE↗

Fuel Cell Tech Team Meeting: Engineered Nano-scale Ceramic Supports for PEM Fuel Cells [Slides]

Catalyst support durability is currently a technical barrier for commercialization of polymer electrolyte membrane (PEM) fuel cells, especially for transportation applications. Degradation and corrosion of the conventional carbon supports leads to losses in active catalyst surface area and, consequently, reduced performance. As a result, the goal of this work is to develop support materials that interact strongly with Pt, yet sustain bulk-like catalytic activities with very highly dispersed particles. Ceramic materials that are prepared using conventional solid-state methods have large grain sizes and low surface areas that can only be minimally ameliorated through grinding and ball milling. Other synthesis routes to produce ceramic materials must be investigated and utilized in order to obtain desired surface areas. In this work, several different synthesis methods are being utilized to prepare electronically conductive ceramic boride, nitride, and oxide materials with high surface areas and have the potential for use as PEMFC catalyst supports. Polymer-assisted deposition (PAD) and aerosol-through plasma (A-T-P) torch are among several methods used to obtain ceramic materials with surface areas that are equal to, or exceed Vulcan XC-72R supports. Cubic Mo-based ceramic phases have been prepared with average XRD-determined crystallite sizes as low as 1.6 nm (from full profile, XRD fitting) and a BET surface area exceeding 200 m 2 /g. Additionally, black, sub-stoichiometric TiO 2-x , have been prepared with an average crystallite size in the 4 nm range and surface areas exceeding 250 m 2 /gr. Pt disposition using an incipient wetness approach produced materials with activity for hydrogen redox reactions and ORR. Cyclic voltammetry data will be shown for a variety of potential Pt/ceramic catalysts. Initial experiments indicate enhanced Pt metal-support interactions as well. Plane wave periodic density functional calculations (VASP) are being used to predict the thermodynamic and activation barriers for fundamental electrode processes occurring at platinum surfaces supported on thin films of the ceramic support materials. The results of this work will be used in order to optimize support properties.

08 HYDROGEN↗

Mapping of Heterogeneous Catalyst Degradation in Polymer Electrolyte Fuel Cells

Pt catalysts in polymer electrolyte fuel cells degrade heterogeneously as the catalyst particles are exposed to local variations throughout the catalyst layer during operation. State-of-the-art analytical techniques for studying degradation of Pt catalysts do not possess fine spatial resolution to elucidate such non-uniform degradation behavior at a large electrode level. A new methodology is developed to spatially resolve and quantify the heterogeneous Pt catalyst degradation over a large area (several cm ) of aged MEAs based on synchrotron X-ray microdiffraction. PEFC single cells are aged using voltage cycling as an accelerated stress test and the degradation heterogeneity at a micrometer length scale is visualized by mapping Pt catalyst particle size after voltage cycling. It is demonstrated in detail that the Pt catalyst particle size growth is non-uniform and follows the flow field geometry. The Pt particle size growth is greater in the area under the flow field land, while it is minimal in the area under the flow field channel. Additional non-uniformity is observed with the Pt particle size increasing more rapidly at the air outlet area than the Pt particle size at the inlet area.

36 MATERIALS SCIENCE↗

X-ray Computed Tomography as a Metrology Technique for the Analysis of Additively Manufactured Material

X-ray computed tomography (X-ray CT) is an analytical technique used in materials science to non-destructively characterize features in a variety materials like polymer, metals, composites, and explosives. It also has the capability of imaging additively manufacture, machine and assembled parts. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of the material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations due to different stimuli and assess the accuracy of material production. This study focuses on parts manufactured via metal additive manufacturing (AM). Although AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties and performance. The analysis of 3D printed objects has an asset in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e., foams) due to stochastic structures. For this study, the print accuracy of four additively manufactured cylinders will be assessed via X-ray CTto approximate the surface roughness and visualize any major morphological changes to assess the dimensional accuracy of complex additively manufactured parts. It was concluded that using X-ray CT to measure surface roughness was affective because reasonable surface roughness values were measured. Additionally, itwas determined that small-scale features can be produced via additive manufacturing with strong dimensional accuracy so long as the features are highly complex with sharp grooves.

36 MATERIALS SCIENCE↗

Real-time crystallization in fluorinated parylene probed by conductivity spectra

Dielectric relaxation spectroscopy experiments were performed at high temperature on fluorinated parylene films during the occurrence of the isothermal crystalline phase transition. For this polymer, since the difference between the glass transition temperature (T{sub g}) and the phase transition temperature (T{sub c}) is very strong (T{sub c} ≥ 4T{sub g}), segmental and dipolar relaxation usually used to probe the crystallization are not shown in the experiment frequency window (10{sup −1} to 10{sup 6} Hz) during the crystallization. The charge diffusion becomes the only electrical marker that allows probing the phase transition. During the transition phase, a continuous decrease of about two orders of magnitude is observed in the conductivity values below an offset frequency (f{sub c}) with a tendency to stabilization after 600 min. Below the offset frequency, the decrease of the normalized conductivity to the initial value as function of time is frequency independent. The same behavior is also observed for the f{sub c} values that decrease from 160 Hz to about 20 Hz. Above the offset frequency, the electronic hopping mechanism is also affected by the phase transition and the power law exponent (n) of the AC conductivity shows a variation from 0.7 to 0.95 during the first 600 min that tend to stabilize thereafter. Accordingly, three parameters (n, f{sub c}, and AC conductivity values for frequencies below f{sub c}) extracted from the AC conductivity spectra in different frequency windows seem suitable to probe the crystalline phase transition.

36 MATERIALS SCIENCE↗