Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Sampling Biases in MODIS and SeaWiFS Ocean Chlorophyll Data

Although modem ocean color sensors, such as MODIS and SeaWiFS are often considered global missions, in reality it takes many days, even months, to sample the ocean surface enough to provide complete global coverage. The irregular temporal sampling of ocean color sensors can produce biases in monthly and annual mean chlorophyll estimates. We quantified the biases due to sampling using data assimilation to create a "truth field", which we then sub-sampled using the observational patterns of MODIS and SeaWiFS. Monthly and annual mean chlorophyll estimates from these sub-sampled, incomplete daily fields were constructed and compared to monthly and annual means from the complete daily fields of the assimilation model, at a spatial resolution of 1.25deg longitude by 0.67deg latitude. The results showed that global annual mean biases were positive, reaching nearly 8% (MODIS) and >5% (SeaWiFS). For perspective the maximum interannual variability in the SeaWiFS chlorophyll record was about 3%. Annual mean sampling biases were low (<3%) in the midlatitudes (between -40deg and 40deg). Low interannual variability in the global annual mean sampling biases suggested that global scale trend analyses were valid. High latitude biases were much higher than the global annual means, up to 20% as a basin annual mean, and over 80% in some months. This was the result of the high solar zenith angle exclusion in the processing algorithms. Only data where the solar angle is <75deg are permitted, in contrast to the assimilation which samples regularly over the entire area and month. High solar zenith angles do not facilitate phytoplankton photosynthesis and consequently low chlorophyll concentrations occurring here are missed by the data sets. Ocean color sensors selectively sample in locations and times of favorable phytoplankton growth, producing overestimates of chlorophyll. The biases derived from lack of sampling in the high latitudes varied monthly, leading to artifacts in the apparent seasonal cycle from ocean color sensors. A false secondary peak in chlorophyll occurred in May-August, which resulted from lack of sampling in the Antarctic.

Gregg, Watson W.↗

An Evaluation of Remotely Sensed and In-Situ Data Sufficiency for SGMA-Scale Groundwater Studies in the Central Valley, California

California’s Central Valley aquifer is a critical freshwater resource for the state, providing drinking water to 6.5 million residents and irrigation water for more than half of the nation’s produce. Increasing demands have led to a steady decline of aquifer water levels, leading to irreversible compaction and land subsidence. The Sustainable Groundwater Management Act of California (SGMA), instituted in 2014, requires high-priority regions to establish sustainability plans by 2020-2022 that mitigate groundwater depletion and land subsidence. Many regions within the Central Valley lack groundwater monitoring wells or continuous well data, rendering in-situ monitoring challenging. When combined with other data, NASA’s Gravity Recovery and Climate Experiment (GRACE) and GRACE Follow On (GRACE-FO) missions provide valuable information about groundwater storage changes at a sub-basin scale. Interferometric Surface Aperture Radar (InSAR) measurements can map land subsidence, and Global Positioning System (GPS) can be used to estimate crustal uplift. Yet, all of these measurements have differences in resolution, coverage, discretization, and record length. Here we assess the various datasets that are potentially useful for Central Valley sub-basin groundwater monitoring and provide an analysis of gaps and other issues in regard to their suitability for SGMA-related analysis. Finally, we offer next steps and recommendations on data treatment and integration.

Kyra H Kim↗

The Wide-field VLBA Calibrator Survey: WFCS

This paper presents the results of the largest very long baseline interferometry (VLBI) absolute astrometry campaign to date of 13,645 radio source observations with the Very Long Baseline Array. Of these, 7220 have been detected, including 6755 target sources that have never been observed with VLBI before. This makes the present VLBI catalog the largest ever published. The positions of the target sources have been determined with the median uncertainty of 1.7 mas, and 15,542 images of 7171 sources have been generated. Unlike previous absolute radio astrometry campaigns, observations were made at 4.3 and 7.6 GHz simultaneously using a single wide-band receiver. Because of the fine spectral and time resolutions, the field of view was 4'–8'—much greater than the 10''–20'' in previous surveys. This made possible the use of input catalogs with low position accuracy and the detection of a compact component in extended sources. Unlike previous absolute astrometry campaigns, both steep- and flat-spectrum sources were observed. The observations were scheduled in the so-called filler mode to fill the gaps between other high-priority programs. This was achieved by the development of the totally automatic scheduling procedure.

Leonid Petrov↗

Gravity monitoring of CO{sub 2} movement during sequestration: Model studies

Sequestration/enhanced oil recovery (EOR) petroleum reservoirs have relatively thin injection intervals with multiple fluid components (oil, hydrocarbon gas, brine, and carbon dioxide, or CO{sub 2}), whereas brine formations usually have much thicker injection intervals and only two components (brine and CO{sub 2}). Coal formations undergoing methane extraction tend to be thin (3-10 m) but shallow compared to either EOR or brine formations. Injecting CO{sub 2} into an oil reservoir decreases the bulk density in the reservoir. The spatial pattern of the change in the vertical component of gravity (G{sub z}) is correlated directly with the net change in reservoir density. Furthermore, time-lapse changes in the borehole G{sub z} clearly identify the vertical section of the reservoir where fluid saturations are changing. The CO{sub 2}-brine front, on the order of 1 km within a 20-m-thick brine formation at 1900-m depth with 30% CO{sub 2} and 70% brine saturations, respectively, produced a -10-{mu} Gal surface gravity anomaly. Such an anomaly would be detectable in the field. The amount of CO{sub 2} in a coal-bed methane scenario did not produce a large enough surface gravity response; however, we would expect that for an industrial-size injection, the surface gravity response would be measurable. Gravity inversions in all three scenarios illustrate that the general position of density changes caused by CO{sub 2} can be recovered but not the absolute value of the change. Analysis of the spatial resolution and detectability limits shows that gravity measurements could, under certain circumstances, be used as a lower-cost alternative to seismic measurements.

01 COAL, LIGNITE, AND PEAT↗

SU-E-T-228: Liquid Ionisation Chamber Array and MicroDiamond Measurements with the CyberKnife System

Purpose: The aim of this study was to measure the dose profile and output factors with a CyberKnife accelerator using a TM60019 microDiamond detector and a 1000SRS liquid chamber array (both PTW Freiburg, Germany). Methods: An MP3 water phantom (PTW, Freiburg) was positioned along the robotic world coordinate system. The TM60019 detector was adjusted to the center of the according fields and the semiconductor axis was aligned with the beam direction. Profiles at 5cm water depth and SSD = 80 cm were measured along the robotic x axis and y axis for the cylindrical collimators of the CyberKnife (diameter 60, 50, 40, 30, 20, 15, 12.5, 10, 7.5 and 5mm). To determine the output factors the dose profile was measured at 0.1 mm steps around the field center to find the maximum dose value. The liquid chamber array (1000SRS) measurement was performed with the same setup, but with RW3 buildup. Results: The 1000SRS measurements closely conform with the TM60019 profile measurement in all profile regions and for all collimator sizes. The profile measurement is influenced by the almost equal spatial resolution of the TM60019 detector (radius of the sensitive area 1.1mm) and of the 1000SRS liquid chamber array (single chamber width 2.3mm). The measured dose profiles have not been corrected for this limited spatial resolution. Rather we purpose to consider that spatial dose averaging over 2 mm wide regions might be justified in view of patient positioning inaccuracies and of the spaces in tissue participating in the biological radiation responses. Conclusion: The 1000SRS data points conform with the TM60019 profile measurements at all profile regions showing the applicability of liquid ion chamber arrays with the CyberKnife system.

60 APPLIED LIFE SCIENCES↗

Electrical resistance tomography to monitor unsaturated moisture flow in cementitious materials

Traditionally the electrically-based assessment of the moisture flow in cement-based materials relies on two- or four-point measurements. In this paper, imaging of moisture distribution with electrical resistance tomography (ERT) is considered. Especially, the aim is to study whether ERT could give information on unsaturated moisture flows in cases where the flow is non-uniform. In the experiment, the specimens are monitored with ERT during the water ingress. The ERT reconstructions are compared with neutron radiographs, which provide high resolution information on the 2D distribution of the moisture. The results indicate that ERT is able to detect the moisture movement and to show approximately the shape and position of the water front even if the flow is nonuniform.

36 MATERIALS SCIENCE↗

Calibration of the NEXT-White detector using 83m Kr decays

We report the NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterraneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83m Kr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 +/- 0.010 (stat.) ± 0.324 (sys.)) % FWHM in the full chamber and (3.804 ± 0.013 (stat.) ± 0.112 (sys.)) % FWHM in a restricted fiducial volume. Laslty, using naive 1/$ \sqrt{E} $ scaling, these values translate into resolutions of (0.5916 ± 0.0014 (stat.) ± 0.0421 (sys.)) % FWHM and (0.4943 ± 0.0017 (stat.) +/- 0.0146 (sys.)) % FWHM at the Qᵦᵦ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

47 OTHER INSTRUMENTATION↗

H I SHELLS AND SUPERSHELLS IN THE I-GALFA H I 21 cm LINE SURVEY. I. FAST-EXPANDING H I SHELLS ASSOCIATED WITH SUPERNOVA REMNANTS

We search for fast-expanding H I shells associated with Galactic supernova remnants (SNRs) in the longitude range l ≈ 32° to 77° using 21 cm line data from the Inner-Galaxy Arecibo L-band Feed Array (I-GALFA) H I survey. Among the 39 known Galactic SNRs in this region, we find such H I shells in 4 SNRs: W44, G54.4-0.3, W51C, and CTB 80. All four were previously identified in low-resolution surveys, and three of those (excluding G54.4-0.3) were previously studied with the Arecibo telescope. A remarkable new result, however, is the detection of H I emission at both very high positive and negative velocities in W44 from the receding and approaching parts of the H I expanding shell, respectively. This is the first detection of both sides of an expanding shell associated with an SNR in H I 21 cm emission. The high-resolution I-GALFA survey data also reveal a prominent expanding H I shell with high circular symmetry associated with G54.4-0.3. We explore the physical characteristics of four SNRs and discuss what differentiates them from other SNRs in the survey area. We conclude that these four SNRs are likely the remnants of core-collapse supernovae interacting with a relatively dense (∼> 1 cm{sup –3}) ambient medium, and we discuss the visibility of SNRs in the H I 21 cm line.

79 ASTRONOMY AND ASTROPHYSICS↗

The Crystal Structure of Cobra Venom Factor, a Cofactor for C3- and C5-Convertase CVFBb

Cobra venom factor (CVF) is a functional analog of human complement component C3b, the active fragment of C3. Similar to C3b, in human and mammalian serum, CVF binds factor B, which is then cleaved by factor D, giving rise to the CVFBb complex that targets the same scissile bond in C3 as the authentic complement convertases C4bC2a and C3bBb. Unlike the latter, CVFBb is a stable complex and an efficient C5 convertase. We solved the crystal structure of CVF, isolated from Naja naja kouthia venom, at 2.6 {angstrom} resolution. The CVF crystal structure, an intermediate between C3b and C3c, lacks the TED domain and has the CUB domain in an identical position to that seen in C3b. The similarly positioned CUB and slightly displaced C345c domains of CVF could play a vital role in the formation of C3 convertases by providing important primary binding sites for factor B.

04 OIL SHALES AND TAR SANDS↗

High-Resolution ESM Projections for Energy Applications Over the CONUS

Assessing energy resources under future scenarios requires high-resolution meteorological information that is physically consistent and suitable for regional-scale analysis. While Earth system model (ESM) projections provide valuable large-scale information, their coarse resolution and systematic biases limit direct applicability for energy system modeling and planning. In this study, we develop a high-resolution dynamical downscaling framework based on the Weather Research and Forecasting (WRF) model to translate global-scale ESM data into energy-relevant regional projections over the contiguous United States (CONUS). The framework identifies an optimized WRF configuration through numerical experiments and evaluates raw and bias-corrected ESM initial and boundary conditions, with soil moisture (SM) and soil temperature (ST) bias correction implemented as an integral part of the bias-corrected ESM forcing to improve land-atmosphere coupling prior to WRF dynamical downscaling. Using an optimized WRF configuration at 4-km resolution, we show that raw ESM forcing introduces systematic dry and cold soil biases that propagate into pronounced warm biases in near-surface air temperature and positive biases in solar irradiance, particularly during summer. Applying bias-corrected atmospheric forcing together with bias-corrected SM and ST substantially reduces these downstream biases and improves the surface energy balance and near-surface atmospheric fields. These results demonstrate that bias-aware treatment of initial conditions is critical for producing high-resolution downscaled projections suitable for energy system modeling and planning applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of the ATF Damping Ring BPM Upgrade Project

A substantial upgrade of the beam position monitors (BPM) at the ATF (Accelerator Test Facility) damping ring is currently in progress. Implementing digital read-out signal processing techniques in line with an optimized, low-noise analog downconverter, a resolution well below 1 mum could be demonstrated at 20 (of 96) upgraded BPM stations. The narrowband, high resolution BPM mode permits investigation of all types of non-linearities, imperfections and other obstacles in the machine which may limit the very low target aimed vertical beam emittance of < 2 pm. The technical status of the project, first beam measurements and an outlook to it's finalization are presented.

43 PARTICLE ACCELERATORS↗

THE JETS OF TeV BLAZARS AT HIGHER RESOLUTION: 43 GHz AND POLARIMETRIC VLBA OBSERVATIONS FROM 2005 TO 2009

We present 23 new VLBA images of the six established TeV blazars Markarian 421, Markarian 501, H 1426+428, 1ES 1959+650, PKS 2155-304, and 1ES 2344+514, obtained from 2005 to 2009. Most images were obtained at 43 GHz (7 mm), and they reveal the parsec-scale structures of three of these sources (1ES 1959+650, PKS 2155-304, and 1ES 2344+514) at factors of 2-3 higher resolution than has previously been attained. These images reveal new morphological details, including a high degree of jet bending in the inner milliarcsecond in PKS 2155-304. This establishes strong apparent jet bending on VLBI scales as a common property of TeV blazars, implying viewing angles close to the line of sight. Most of the remaining images map the linear polarization structures at a lower frequency of 22 GHz (1 cm). We discuss the transverse structures of the jets as revealed by the high-frequency and polarimetric imaging. The transverse structures include significant limb brightening in Mrk 421, and 'spine-sheath' structures in the electric vector position angle and fractional polarization distributions in Mrk 421, Mrk 501, and 1ES 1959+650. We use new measured component positions to update measured apparent jet speeds, in many cases significantly reducing the statistical error over previously published results. With the increased resolution at 43 GHz, we detect new components within 0.1-0.2 mas of the core in most of these sources. No motion is apparent in these new components over the time span of our observations, and we place upper limits on the apparent speeds of the components near the core of <2c. From those limits, we conclude that {Gamma}{sub 2} < ({Gamma}{sub 1}){sup 1/2} at {approx}10{sup 5} Schwarzschild radii, where {Gamma}{sub 1} and {Gamma}{sub 2} are the bulk Lorentz factors in the TeV emitting and 43 GHz emitting regions, respectively, assuming that their velocity vectors are aligned.

79 ASTRONOMY AND ASTROPHYSICS↗

High resolution decoding of Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a photon counting detector which utilizes a photocathode for photon to electron conversion, a microchannel plate (MCP) for signal amplification and a proximity focused anode array for position sensitivity. The detector electronics decode the position of an event through coincidence discrimination. The decoding algorithm which associates a given event with the appropriate pixel is determined by the geometry of the array. A new algorithm incorporated into a CMOS Application Specific Integrated Circuit (ASIC) decoder which improves the pixel spatial resolution is described. The new algorithm does not degrade the detector throughput and does not require any modifications to the detector tube. The standard MAMA detector has a pixel size of 25 x 25 square microns, but with the new decoder circuit the pixel size is reduced to 12.5 x 12.5 square microns. We have built the first set of decode electronics utilizing the new ASIC chips and report here on the first imaging tests of this system.

Kasle, David B.↗

An x-ray setup to investigate the atomic order of confined liquids in slit geometry

A setup has been designed to investigate thin films of confined liquids with the use of X-ray scattering methods. The confinement is realized between the flat culets of a pair of diamonds by positioning and orienting the lower diamond with nanometer and micro radian accuracy. We routinely achieve gaps between 5 and 50 nm at culet diameters of 200 μm. With this setup and a micro focused X-ray beam we have investigated the in-plane and the out-off-plane atomic order of benzene with atomic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Small-angle neutron scattering reveals the assembly mode and oligomeric architecture of TET, a large, dodecameric aminopeptidase

The present work illustrates that small-angle neutron scattering, deuteration and contrast variation, combined with in vitro particle reconstruction, constitutes a very efficient approach to determine subunit architectures in large, symmetric protein complexes. In the case of the 468 kDa heterododecameric TET peptidase machine, it was demonstrated that the assembly of the 12 subunits is a highly controlled process and represents a way to optimize the catalytic efficiency of the enzyme. The specific self-association of proteins into oligomeric complexes is a common phenomenon in biological systems to optimize and regulate their function. However, de novo structure determination of these important complexes is often very challenging for atomic-resolution techniques. Furthermore, in the case of homo-oligomeric complexes, or complexes with very similar building blocks, the respective positions of subunits and their assembly pathways are difficult to determine using many structural biology techniques. Here, an elegant and powerful approach based on small-angle neutron scattering is applied, in combination with deuterium labelling and contrast variation, to elucidate the oligomeric organization of the quaternary structure and the assembly pathways of 468 kDa, hetero-oligomeric and symmetric Pyrococcus horikoshii TET2–TET3 aminopeptidase complexes. The results reveal that the topology of the PhTET2 and PhTET3 dimeric building blocks within the complexes is not casual but rather suggests that their quaternary arrangement optimizes the catalytic efficiency towards peptide substrates. This approach bears important potential for the determination of quaternary structures and assembly pathways of large oligomeric and symmetric complexes in biological systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural Basis for Imipenim Inhibition of Class C [beta]-Lactamases

To determine how imipenem inhibits the class C {beta}-lactamase AmpC, the X-ray crystal structure of the acyl-enzyme complex was determined to a resolution of 1.80 {angstrom}. In the complex, the lactam carbonyl oxygen of imipenem has flipped by approximately 180{sup o} compared to its expected position; the electrophilic acyl center is thus displaced from the point of hydrolytic attack. This conformation resembles that of imipenem bound to the class A enzyme TEM-1 but is different from that of moxalactam bound to AmpC.

36 MATERIALS SCIENCE↗