Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

The development of non destructive remote measurement method of concrete contamination

In the frame of the decommissioning of nuclear power plants or laboratories, the penetration depth of the contamination in concrete surfaces: walls, floor, is unknown. Its knowledge requires sample analysis, that is time consuming and expensive. The main goal of the work is to define and evaluate a non-destructive measurement technique for the evaluation of the contamination depth in concrete. Estimation of accuracy of measurements for different contamination levels, time of measurement, value of natural radionuclides (NRN) concentration in concrete and background radiation dose were carried out. The type of relevant detector depends of selected limiting sensitivity, the weight and sizes of the device. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MO-DE-207-04: Imaging educational program on solutions to common pediatric imaging challenges

This imaging educational program will focus on solutions to common pediatric imaging challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children’s hospitals. The educational program will begin with a detailed discussion of the optimal configuration of fluoroscopes for general pediatric procedures. Following this introduction will be a focused discussion on the utility of Dual Energy CT for imaging children. The third lecture will address the substantial challenge of obtaining consistent image post -processing in pediatric digital radiography. The fourth and final lecture will address best practices in pediatric MRI including a discussion of ancillary methods to reduce sedation and anesthesia rates. Learning Objectives: To learn techniques for optimizing radiation dose and image quality in pediatric fluoroscopy To become familiar with the unique challenges and applications of Dual Energy CT in pediatric imaging To learn solutions for consistent post-processing quality in pediatric digital radiography To understand the key components of an effective MRI safety and quality program for the pediatric practice.

60 APPLIED LIFE SCIENCES↗

Impact of Adding Concomitant Chemotherapy to Hyperfractionated Accelerated Radiotherapy for Advanced Head-and-Neck Squamous Cell Carcinoma

Purpose: To evaluate the feasibility and efficacy of a hyperfractionated accelerated radiotherapy (RT) schedule combined with concomitant chemotherapy (Cx) in patients with locally advanced head-and-neck squamous cell carcinoma. Methods and Materials: Between 2004 and 2007, a total of 90 patients with locoregionally advanced head-and-neck squamous cell carcinoma underwent irradiation according to a hybrid fractionation schedule consisting of 20 fractions of 2 Gy (once daily) followed by 20 fractions of 1.6 Gy (twice daily) to a total dose of 72 Gy. Concomitant Cx (cisplatinum 100 mg/m{sup 2}) was administered at the start of Weeks 1 and 4. Treatment outcome and toxicity were retrospectively compared with a previous patient group (n = 73) treated with the same schedule, but without concomitant Cx, between 2001 and 2004. Results: The locoregional control (LRC) rate was 70% after 2 years. Two-year overall and 2-year disease-free survival rates were 74% and 60%, respectively. In comparison with the RT-only group, an improvement of 15% in both LRC (p = 0.03) and overall survival (p = 0.09) was observed. All patients were treated to full radiation dose according to protocol, although the Cx schedule had to be adjusted in 12 patients. No acute Grade 4 or 5 toxicity was seen, but incidences of Grade 3 acute mucositis (74.5% vs. 50.7%; p = 0.002) and dysphagia (82.2% vs. 47.9%; p < 0.001) were significantly higher in the chemoradiotherapy group compared with patients treated with RT alone. Conclusion: With this chemoradiotherapy regimen, excellent LRC and survival rates were achieved, with acceptable acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How to Prepare a Patient for Transarterial Radioembolization? A Practical Guide

Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Radiation Therapy to the Primary Tumor With Concurrent Chemotherapy in Patients With Stage IV Non-Small Cell Lung Cancer: Results of a Multicenter Phase 2 Study From PPRA-RTOG, China

Purpose: The aim of this prospective multi-institutional phase 2 study was to investigate disease control, survival outcomes, and toxicity after thoracic three-dimensional radiation therapy (3D-RT) with concurrent chemotherapy for newly diagnosed stage IV non-small cell lung cancer (NSCLC). Methods and Materials: Eligible patients were 18 to 80 years of age, had a Karnofsky performance status (KPS) score ≥70%, and newly diagnosed stage IV NSCLC with limited metastatic disease (defined as involving ≤3 organs). Patients received platinum-doublet chemotherapy with concurrent irradiation to the primary tumor. Primary endpoints were overall survival (OS) and acute toxicity. Results: From May 2008 to May 2012, 198 eligible patients were enrolled from 7 cancer centers. Most patients died with distant metastasis; only 10% died with isolated primary recurrence. Median OS time was 13.0 months (95% confidence interval [CI]: 11.7-14.3); OS rates were 53.5% at 1 year, 15.8% at 2 years, and 9.2% at 3 years. Median progression-free survival (PFS) time was 9.0 months (95% CI: 7.7-10.3); corresponding PFS rates were 30.8%, 8.2%, and 6.1%. The 1-year, 2-year, and 3-year local (primary tumor) control rates were 78.8%, 57.7%, and 55.4%. Multivariate analysis showed that delivery of ≥63 Gy to the primary tumor (P=.014), having a primary tumor volume <134 cm{sup 3} (P=.008), and having a stable or higher KPS score after treatment (P=.01) were independent predictors of better OS. The most common severe (grades 3-4) acute toxicities were hematologic: leukopenia (37.9%), thrombocytopenia (10.1%), and anemia (6.9%). No patients experienced grade 4 or 5 radiation-related toxicity; 2.5% had acute grade 3 pneumonitis, and 6.6% had acute grade 3 radiation esophagitis. Conclusions: Thoracic 3D-RT to the primary tumor with concurrent chemotherapy led to satisfactory survival outcomes with acceptable toxicity. Radiation dose, primary tumor volume, and PFS after treatment all predicted survival in these patients with limited-metastasis NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation tolerance of ultra-thin Formvar films

Mechanical behavior of free-standing polymer films with submicron thicknesses exposed to a radiation environment is poorly understood. Here, we study 110-nm-thin free-standing polyvinyl formal (Formvar) films irradiated at room temperature with 1-5 keV electrons or 3 MeV alpha particles. We measure mechanical properties and the elemental composition by spherical indentation and high-energy ion scattering, respectively. Results show that, with increasing radiation dose, the effective failure strain and film thickness decrease monotonically, while the dose dependence of the Young's modulus is non-monotonic. The failure strain and modulus scale with the average energy deposited in the film, while the film thickness exhibits a more complex behavior.

36 MATERIALS SCIENCE↗

TU-H-BRA-08: The Design and Characteristics of a Novel Compact Linac-Based MRI Guided Radiation Therapy (MR-IGRT) System

Purpose: To describe the design and characteristics of a novel linac-based MRI guided radiation therapy system that addresses RF and magnetic field interference and that can be housed in conventional radiotherapy vaults. Methods: The MR-IGRT system will provide simultaneous MR imaging combined with both simple (3D) and complex (IMRT, SBRT, SRS) techniques. The system is a combination of a) double-donut split solenoidal superconducting 0.345T MRI; and b) a 90 cm isocenter ring-gantry mounted 6MV, flattening filter-free linac coupled with a stacked doubly-focused multileaf collimator with 4 mm resolution. A novel RF shielding and absorption technology was developed to isolate the beam generating RF emissions from the MR, while a novel magnetic shielding sleeve system was developed to place the magnetic field-sensitive components in low-magnetic field regions. The system design produces high spatial resolution radiation beams with state-of-the art radiation dose characteristics and simultaneous MR imaging. Results: Prototype testing with a spectrum analyzer has demonstrated complete elimination of linac RF inside the treatment room. The magnetic field inside of the magnetic shielding was well below the specification, allowing the linear accelerator to operate normally. A novel on-gantry shimming system maintained < 25 ppm magnetic field homogeneity over a 45 cm spherical field of view for all gantry angles. Conclusion: The system design demonstrates the feasibility coupling a state-of-the art linac system with a 0.345T MRI, enabling highly conformal radiation therapy with simultaneous MR image guidance. S. Mutic’s employer (Washington University) has grant with ViewRay; D. Low is former ViewRay scientific advisory board member (ended October 2015); T. Chmielewski, G. Fought, M. Hernandez, I. Kawrakow, A. Sharma, S. Shvartsman, J. Dempsey are employees of ViewRay with stock options (Dempsey has leadership role and Dempsey/Kawrakow have stock).

60 APPLIED LIFE SCIENCES↗

Early Assessment of Treatment Responses During Radiation Therapy for Lung Cancer Using Quantitative Analysis of Daily Computed Tomography

Purpose: To investigate early tumor and normal tissue responses during the course of radiation therapy (RT) for lung cancer using quantitative analysis of daily computed tomography (CT) scans. Methods and Materials: Daily diagnostic-quality CT scans acquired using CT-on-rails during CT-guided RT for 20 lung cancer patients were quantitatively analyzed. On each daily CT set, the contours of the gross tumor volume (GTV) and lungs were generated and the radiation dose delivered was reconstructed. The changes in CT image intensity (Hounsfield unit [HU]) features in the GTV and the multiple normal lung tissue shells around the GTV were extracted from the daily CT scans. The associations between the changes in the mean HUs, GTV, accumulated dose during RT delivery, and patient survival rate were analyzed. Results: During the RT course, radiation can induce substantial changes in the HU histogram features on the daily CT scans, with reductions in the GTV mean HUs (dH) observed in the range of 11 to 48 HU (median 30). The dH is statistically related to the accumulated GTV dose (R{sup 2} > 0.99) and correlates weakly with the change in GTV (R{sup 2} = 0.3481). Statistically significant increases in patient survival rates (P=.038) were observed for patients with a higher dH in the GTV. In the normal lung, the 4 regions proximal to the GTV showed statistically significant (P<.001) HU reductions from the first to last fraction. Conclusion: Quantitative analysis of the daily CT scans indicated that the mean HUs in lung tumor and surrounding normal tissue were reduced during RT delivery. This reduction was observed in the early phase of the treatment, is patient specific, and correlated with the delivered dose. A larger HU reduction in the GTV correlated significantly with greater patient survival. The changes in daily CT features, such as the mean HU, can be used for early assessment of the radiation response during RT delivery for lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Precision and accuracy of a commercially available CT optically stimulated luminescent dosimetry system for the measurement of CT dose index

Purpose: To determine the precision and accuracy of CTDI{sub 100} measurements made using commercially available optically stimulated luminescent (OSL) dosimeters (Landaur, Inc.) as beam width, tube potential, and attenuating material were varied. Methods: One hundred forty OSL dosimeters were individually exposed to a single axial CT scan, either in air, a 16-cm (head), or 32-cm (body) CTDI phantom at both center and peripheral positions. Scans were performed using nominal total beam widths of 3.6, 6, 19.2, and 28.8 mm at 120 kV and 28.8 mm at 80 kV. Five measurements were made for each of 28 parameter combinations. Measurements were made under the same conditions using a 100-mm long CTDI ion chamber. Exposed OSL dosimeters were returned to the manufacturer, who reported dose to air (in mGy) as a function of distance along the probe, integrated dose, and CTDI{sub 100}. Results: The mean precision averaged over 28 datasets containing five measurements each was 1.4%{+-} 0.6%, range = 0.6%-2.7% for OSL and 0.08%{+-} 0.06%, range = 0.02%-0.3% for ion chamber. The root mean square (RMS) percent differences between OSL and ion chamber CTDI{sub 100} values were 13.8%, 6.4%, and 8.7% for in-air, head, and body measurements, respectively, with an overall RMS percent difference of 10.1%. OSL underestimated CTDI{sub 100} relative to the ion chamber 21/28 times (75%). After manual correction of the 80 kV measurements, the RMS percent differences between OSL and ion chamber measurements were 9.9% and 10.0% for 80 and 120 kV, respectively. Conclusions: Measurements of CTDI{sub 100} with commercially available CT OSL dosimeters had a percent standard deviation of 1.4%. After energy-dependent correction factors were applied, the RMS percent difference in the measured CTDI{sub 100} values was about 10%, with a tendency of OSL to underestimate CTDI relative to the ion chamber. Unlike ion chamber methods, however, OSL dosimeters allow measurement of the radiation dose profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An imrt technique to increase therapeutic ratio of breast irradiation in patients with early-stage left breast cancer: limiting second malignancies

The clinical application of intensity modulated radiotherapy (IMRT) for adjuvant treatment of breast cancer has been the subject of increasing study in recent years. IMRT results in improved target coverage, reduced dose inhomogeneity within the breast, and reduced dose to the heart, lungs, and contralateral breast. However, this has been at the cost of larger volumes of low-dose radiation to these structures, thus increasing the theoretic risk for second malignancies. Our goal was to develop an IMRT beam arrangement that did not result in additional low-dose spill to organs at risk while maintaining equal or better target coverage. Five patients with early-stage left-sided breast cancer, who underwent breast conservation surgery and adjuvant radiation therapy, were chosen for this comparative study. The conventional radiation treatment (CRT) plan was comprised of standard wedged tangential fields. An IMRT plan consisting of 6 tangential beams (3 medial and 3 lateral) was generated by using the gantry, collimator, and table angles of the standard plan used for the CRT plan, and moving the table +10 deg. and -10 deg. on each side. The prescription dose for both CRT and IMRT plans was 45 Gy, 1.8 Gy/fraction, prescribed to the isocenter, which was placed near the center of the breast. IMRT plans provided significantly better coverage of the left breast than the CRT plans (p = 0.03). Although the dose heterogeneity was greater with the IMRT plans, the difference was not significant (p = 0.68). The mean volumes of the heart, lung, and right breast were lower in patients planned with IMRT at all dose levels from 5% to 100% dose (5% increments). This difference was significant for volumes receiving 2.25 Gy for the heart (p = 0.003), and volumes receiving 2.25, 4.5, 6.75, 33.75, 36, 38.25, and 42.75 Gy for the lung (p = 0.014, 0.04, 0.044, 0.05, 0.049, 0.045, and 0.05, respectively). Surprisingly, breast IMRT resulted in significantly lower right breast volumes irradiated at all dose levels compared to CRT. A 6-tangential-field IMRT technique achieved significantly better left breast coverage while maintaining lower doses to risk organs at all dose levels and therefore reduced the potential for induction of a second malignancy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Silver Clear Nylon Dressing is Effective in Preventing Radiation-Induced Dermatitis in Patients With Lower Gastrointestinal Cancer: Results From a Phase III Study

Purpose: For patients with anal canal and advanced rectal cancer, chemoradiation therapy is a curative modality or an important adjunct to surgery. Nearly all patients treated with chemoradiation experience some degree of radiation-induced dermatitis (RID). Prevention and effective treatment of RID, therefore, is of considerable clinical relevance. The present phase III randomized trial compared the efficacy of silver clear nylon dressing (SCND) with that of standard skin care for these patients. Methods and Materials: A total of 42 rectal or anal canal cancer patients were randomized to either a SCND or standard skin care group. SCND was applied from Day 1 of radiation therapy (RT) until 2 weeks after treatment completion. In the control arm, sulfadiazine cream was applied at the time of skin dermatitis. Printed digital photographs taken 2 weeks prior to, on the last day, and two weeks after the treatment completion were scored by 10 blinded readers, who used the common toxicity scoring system for skin dermatitis. Results: The radiation dose ranged from 50.4 to 59.4 Gy, and there were no differences between the 2 groups. On the last day of RT, when the most severe RID occurs, the mean dermatitis score was 2.53 (standard deviation [SD], 1.17) for the standard and 1.67 (SD, 1.2; P=.01) for the SCND arm. At 2 weeks after RT, the difference was 0.39 points in favor of SCND (P=.39). There was considerable intraclass correlation among the 10 observers. Conclusions: Silver clear nylon dressing is effective in reducing RID in patients with lower gastrointestinal cancer treated with combined chemotherapy and radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric advantages of intensity-modulated proton therapy for oropharyngeal cancer compared with intensity-modulated radiation: A case-matched control analysis

A potential advantage of intensity-modulated proton therapy (IMPT) over intensity-modulated (photon) radiation therapy (IMRT) in the treatment of oropharyngeal carcinoma (OPC) is lower radiation dose to several critical structures involved in the development of nausea and vomiting, mucositis, and dysphagia. The purpose of this study was to quantify doses to critical structures for patients with OPC treated with IMPT and compare those with doses on IMRT plans generated for the same patients and with a matched cohort of patients actually treated with IMRT. In this study, 25 patients newly diagnosed with OPC were treated with IMPT between 2011 and 2012. Comparison IMRT plans were generated for these patients and for additional IMRT-treated controls extracted from a database of patients with OPC treated between 2000 and 2009. Cases were matched based on the following criteria, in order: unilateral vs bilateral therapy, tonsil vs base of tongue primary, T-category, N-category, concurrent chemotherapy, induction chemotherapy, smoking status, sex, and age. Results showed that the mean doses to the anterior and posterior oral cavity, hard palate, larynx, mandible, and esophagus were significantly lower with IMPT than with IMRT comparison plans generated for the same cohort, as were doses to several central nervous system structures involved in the nausea and vomiting response. Similar differences were found when comparing dose to organs at risks (OARs) between the IMPT cohort and the case-matched IMRT cohort. In conclusion, these findings suggest that patients with OPC treated with IMPT may experience fewer and less severe side effects during therapy. This may be the result of decreased beam path toxicities with IMPT due to lower doses to several dysphagia, odynophagia, and nausea and vomiting–associated OARs. Further study is needed to evaluate differences in long-term disease control and chronic toxicity between patients with OPC treated with IMPT in comparison to those treated with IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-B-201-00: Motion Management in Current Stereotactic Body Radiation Therapy (SBRT) Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-01: Overcoming the Challenges of Motion Management in Current Lung SBRT Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-02: Motion Management for Proton Lung SBR

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

Adsorbent materials development and testing for the extraction of uranium from seawater

The extraction of uranium from seawater has been the focus of a research project for the U.S. Department of Energy to develop amidoxime functional group adsorbents using radiation-induced graphing on polymer-based fiber materials and subsequent chemical conversion of the radical sites to form the desired adsorbent material. Materials with promising uranium adsorption capacities were prepared through a series of parametric studies on radiation dose, time, temperature, graphing solutions, and properties of the base polymer materials. A laboratory screening protocol was developed to determine the uranium adsorption capacity to identify the most promising candidate materials for seawater testing. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of Dose on Risk of Acute Urinary Retention After Iodine-125 Prostate Brachytherapy

Purpose: To assess the influence of dose on the risk of acute urinary retention (AUR) after iodine-125 prostate brachytherapy. Methods and Materials: Between January 2005 and December 2008, 714 consecutive patients with localized prostate cancer were treated with iodine-125 prostate brachytherapy at our department. All patients completed four imaging studies: magnetic resonance imaging before and 4 weeks after treatment and intraoperative three-dimensional transrectal ultrasonography before and after implantation. The development of AUR was prospectively recorded. The evaluated treatment and dosimetric parameters included prostate volume, number of needles and seeds used, intra- and postoperative prostate edema, percentage of prostate volume receiving 100%, 150%, and 200% of the prescribed dose to the prostate, minimal dose received by 90% of the prostate volume, and percentage of the urethra receiving 100%, 150%, and 200% of the prescribed dose. Logistic regression analysis was used to examine which factors were associated with AUR. Results: Of the 714 patients, 57 (8.0%) developed AUR. On univariate analysis, the following treatment and dosimetric factors were significantly associated with AUR: International Prostate Symptom Score (odds ratio [OR], 2.07, per 10-point increase), preimplant prostate volume (OR, 1.06), postimplant prostate volume (OR, 1.04), number of needles used (OR, 1.09), and number of seeds used (OR, 1.03). On multivariate analysis, the only independent predictive factors for AUR were pretreatment prostate volume (OR, 1.05) and International Prostate Symptom Score (OR, 1.76, per 10-point increase). Patients with a pretreatment prostate volume >35 cm{sup 3} had a 10.4% risk of developing AUR compared with 5.4% for those with a prostate volume of {<=}35 cm{sup 3}. No association was found between any of the dosimetric parameters and the development of AUR. Conclusion: The radiation dose, within the range studied, did not influence the risk of AUR after iodine-125 prostate brachytherapy. Prostate volume and International Prostate Symptom Score were the most important predictors of AUR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling of Tumor Control Probability in Stereotactic Body Radiation Therapy for Adrenal Tumors

Stereotactic body radiation therapy (SBRT) in the management of adrenal metastases is emerging as a well-tolerated, effective method of treatment for patients with limited metastatic disease. SBRT planning and treatment utilization are widely variable, and publications report heterogeneous radiation dose fractionation schemes and treatment outcomes. The objective of this analysis was to review the current literature on SBRT for adrenal metastases and to develop treatment guidelines and a model for tumor control probability of SBRT for adrenal metastases based on these publications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗